8 recordsLinked to original sources

Formulation of four Katsevich algorithms in native geometry.

We derive formulations of the four exact helical Katsevich algorithms in the native cylindrical detector geometry, which allow efficient implementation in modern computed tomography scanners with wide cone beam aperture. Also, we discuss some aspects of numerical implementation.

Algorithms↗

Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction.

Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the nature of the data (e.g., cone-angle), or the reconstruction algorithm itself. An algorithm which provides the best temporal resolution for each slice, for example, often provides suboptimal image quality for the entire volume since the cardiac temporal resolution (TRc) changes from slice to slice. Such variations in TRc can generate strong banding artifacts in multiplanar reconstruction images or three-dimensional images. Discontinuous heart walls and coronary arteries may compromise the accuracy of the diagnosis. A beta-blocker is often used to reduce and stabilize patients' heart rate but cannot eliminate the variation. In order to obtain robust and optimal image quality, a software solution that increases the temporal resolution and decreases the effect of heart rate is highly desirable. This paper proposes an ECG-correlated direct cone-beam reconstruction algorithm (TCOT-EGR) with cardiac banding artifact correction (CBC) and disconnected projections redundancy compensation technique (DIRECT). First the theory and analytical model of the cardiac temporal resolution is outlined. Next, the performance of the proposed algorithms is evaluated by using computer simulations as well as patient data. It will be shown that the proposed algorithms enhance the robustness of the image quality against inconsistencies by guaranteeing smooth transition of heart cycles used in reconstruction.

Algorithms↗

Helical cone beam CT with an asymmetrical detector.

If a multislice or other area detector is shifted to one side to cover a larger field of view, then the data are truncated on one side. We propose a method to restore the missing data in helical cone-beam acquisitions that uses measured data on the longer side of the asymmetric detector array. The method is based on the idea of complementary rays, which is well known in fan beam geometry; in this paper we extend this concept to the cone-beam case. Different cases of complementary data coverage and dependence on the helical pitch are considered. The proposed method is used in our prototype 16-row CT scanner with an asymmetric detector and a 700 mm field of view. For evaluation we used scanned body phantom data and computer-simulated data. To simulate asymmetric truncation, the full, symmetric datasets were truncated by dropping either 22.5% or 45% from one side of the detector. Reconstructed images from the prototype scanner with the asymmetrical detector show excellent image quality in the extended field of view. The proposed method allows flexible helical pitch selection and can be used with overscan, short-scan, and super-short-scan reconstructions.

Algorithms↗

A new weighting scheme for cone-beam helical CT to reduce the image noise.

Reducing the patient dose while keeping the image noise at the same level is desired for x-ray CT examinations. In order to achieve the goal, we propose a new weighting scheme taking the validity of the data and redundant data samples into account. The method is evaluated with a new generalized version of the Feldkamp helical reconstruction algorithm. It allows us to enlarge the projection angular range used in reconstruction, and thus, to reduce the image noise by increasing the detector utilization rate to 100% without sacrificing the image quality or z-resolution. This concept can be adapted to other exact or approximate algorithms as far as they use redundant data samples.

Algorithms↗

The cause of the artifact in 4-slice helical computed tomography.

The causes of the image artifacts in a 4-slice helical computed tomography have been discussed as follows: (1) changeover in pairs of data used in z interpolation, (2) sampling interval in z, and (3) the cone angle. This study analyzes the first two causes of the artifact and describes how the current algorithm [K. Taguchi and H. Aradate, Radiology 205P, 390 (1997); 205P, 618 (1997); Med. Phys. 25, 550-561 (1998); H. Hu, ibid. 26, 5-18 (1999); S. Schaller et al., IEEE Trans. Med. Imaging 19, 822-834 (2000); K. Taguchi, Ph.D. thesis, University of Tsukuba, 2002] solves the problem. An interpolated sinogram for a slice at the edge of a ball phantom shows discontinuity caused by the changeover. If we extend the streak artifact in the reconstructed image, it crosses the focus orbit at the corresponding projection angle. Applying z filtering can reduce such causes by its feathering effect and mixing data obtained by different cone angles; the best results are provided when z filtering is applied to densely sampled helical data.

Algorithms↗

Temporal resolution and the evaluation of candidate algorithms for four-dimensional CT.

The four-dimensional computed tomography ("4D-CT") with area detector has been developed for dynamic volumetric imaging with large longitudinal coverage. In this paper one of the key technologies for 4D-CT development is discussed: Image reconstruction algorithm with high temporal resolution. All of the cone-beam algorithms investigated previously assume that the object is stationary. In this paper a new class of cone-beam problem is addressed: a dynamic volumetric (4-D) imaging. A continuously rotating circular (stationary couch) scanning is employed, and then, a generalized version of the well-known Feldkamp algorithm with the following three steps is performed: (1) applying a weighting function (along the time axis) to projection data, (2) filtering the weighted data along the detector row direction, (3) cone-beam backprojecting of the filtered data along the corresponding x-ray path. The weighting function controls the time center, the temporal resolution, and the image quality. Four weighting functions developed for fan-beam reconstruction were applied to the first step: (a) a constant weight fixed at 0.5 (FS-FDK), (b) feathering both edges of the (time) window (OS-FDK), (c) Parker's weight for a half-scan (HF-FDK), and (d) an extended Parker's weight, which allows us to use a larger range of projection data up to one rotation (NHS-FDK). We evaluated them in terms of temporal resolution, image noise, and image quality. Also, the cause of the artifact has been investigated. The temporal resolution of NHF-FDK equals that of HS-FDK, which is half of the one rotation period. For the moving object, NHS-FDK offers the best image quality. The images with FS-FDK are degraded by streak artifacts; HS-FDK provides poor image quality with good temporal resolution; and images by OS-FDK are blurred due to insufficient temporal resolution. The cause of the artifact was found as an inconsistency of projection data due to object motion (in FS-FDK) and lost 3-D-Radon data caused by applying Parker's weight (in HS-FDK). A hand toy was employed for the preliminary evaluation of dynamic volumetric imaging with the real 256-slice scanner. In an overall evaluation, NHS-FDK provides the stable and the sufficient image quality both with moving and stationary objects.

Artifacts↗

Feldkamp-based cone-beam reconstruction for gantry-tilted helical multislice CT.

Depending on the clinical application, it is frequently necessary to tilt the gantry of an x-ray CT system with respect to the patient and couch. For single-slice fan-beam systems, tilting the gantry introduces no errors or artifacts. Most current systems, however, are helical multislice systems with up to 16 slices. The multislice helical reconstruction algorithms used to create CT images must be modified to account for tilting of the gantry. If they are not, the quality of reconstructed images will be poor with the presence of significant artifacts, such as smearing and double-imaging of anatomical structures. Current CT systems employ three primary types of reconstruction algorithms: helical fan-beam approximation, advanced single-slice rebinning, and Feldkamp-based algorithms. This paper presents a generalized helical cone-beam Feldkamp-based algorithm that is valid for both tilted and nontilted orientations of the gantry. Unlike some of the other algorithms, generalization of the Feldkamp algorithm to include gantry tilt is simple and straightforward with no significant increase in computational complexity. The effect of gantry tilt for helical Feldkamp reconstruction is to introduce a lateral shift in the isocenter of the reconstructed slice of interest, which is a function of the tilt, couch speed, and view angle. The lateral shift is easily calculated and incorporated into the helical Feldkamp backprojection algorithm. A tilt-generalized helical Feldkamp algorithm has been developed and incorporated into Aquilion 16-slice CT (Toshiba, Japan) scanners. This paper describes modifications necessary for the tilt generalization and its verification.

Algorithms↗