Search PubMed⌕ Search

Biomedical subjects

Katsumi Uchiyama

Publications and source records attributed to Katsumi Uchiyama.

17 recordsLinked to original sources

Development of a surface-reaction system in a nanoliter droplet made by an ink-jet microchip.

A surface-reaction system in a nanoliter water pool using an ink-jet microchip was developed. The reaction system in the nanodroplets formed on a poly(dimethylsiloxane) (PDMS) coated glass slide increased the diffusion-controlled reaction without using a nano-pump, specialized connector or highly sensitive detector. When nanoliter droplets were placed on the PDMS surface with a distance of 100 microm between them by the ink-jet microchip, the repeatabilities of the fluorescence intensity were 2.9% RSD (n = 7). The used ink-jet microchip had 4 different injection ports, and the distance between the ports was 0.995 mm. It was necessary to correct the distance in order to mix or dilute samples in a small droplet. The correction was successfully performed by moving the X-Y stage using inhouse-made software. A linear relationship was obtained between the Resorufin concentrations and the fluorescence intensity. We applied this system to an enzyme-linked immunosorbent assay (ELISA) for immunoglobulin A (IgA), and observed a difference in the fluorescence intensity derived from the amount of IgA (blank, 6.25 ng/mL, 12.5 ng/mL). These results show the usefulness of the open-type micro-analytical systems proposed by us.

Journal Article↗

Fabrication of an integrated PDMS microchip incorporating an LED-induced fluorescence device.

A microfluidic device with an integrated fluorescence detection system has been developed in order to miniaturize the entire analytical system. A blue or green light-emitting diode (LED) and an optical fiber were mounted in a polydimethylsiloxane-based microchip. The performance of this device was evaluated by microchip electrophoresis. When a green LED was used as the light source, the calibration curve of Sulforhodamine-101 was linear over the range 1-100 microM. The detection limit was found to be 600 nM (240 amol) for a S/N ratio of 3. When using a blue LED, the calibration curve of Fluorescein was linear over the range 0.2-100 microM. The detection limit was estimated to be 120 nM (50 amol) (S/N=3). The detection sensitivity per unit power was comparable to that of LIF. The RSD values for the migration time, peak height and peak area were 0.74, 7.18 and 9.45%, respectively. The integrated microfluidic device was successfully used to determine amino acid derivatives.

Amino Acids↗

An integrated microfluidic device in polyester for electrophoretic analysis of amino acids.

A precolumn reaction chamber was integrated into a polyester microfluidic device with a miniaturized detection system. The reaction chamber was designed to be a zigzag channel, 70 microm in width, 8 mm in length, followed by a wider straight channel, 150 microm in width, 2 mm in length. The detection system is composed of an embedded light-emitting diode (LED), an integrated optical fiber, and a photomultiplier tube (PMT). A success in amino acid analysis using the integrated microchemical analysis device proved that the precolumn reaction chamber was compatible with the integrated detection system. Three kinds of amino acids, arginine, glycine, and phenylalanine, mixed and reacted with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) in the precolumn reaction chamber to produce fluorescent products, were separated by micellar eletrokinetic chromatography (MEKC) and detected by LED-excited fluorescence. The detection limits for arginine, glycine, and phenylalanine were 1, 1, and 0.5 mM, respectively, which can be improved by further optimizations of the reaction system and detection system.

4-Chloro-7-nitrobenzofurazan↗

A polymeric master replication technology for mass fabrication of poly(dimethylsiloxane) microfluidic devices.

A protocol of producing multiple polymeric masters from an original glass master mold has been developed, which enables the production of multiple poly(dimethylsiloxane) (PDMS)-based microfluidic devices in a low-cost and efficient manner. Standard wet-etching techniques were used to fabricate an original glass master with negative features, from which more than 50 polymethylmethacrylate (PMMA) positive replica masters were rapidly created using the thermal printing technique. The time to replicate each PMMA master was as short as 20 min. The PMMA replica masters have excellent structural features and could be used to cast PDMS devices for many times. An integration geometry designed for laser-induced fluorescence (LIF) detection, which contains normal deep microfluidic channels and a much deeper optical fiber channel, was successfully transferred into PDMS devices. The positive relief on seven PMMA replica masters is replicated with regard to the negative original glass master, with a depth average variation of 0.89% for 26-microm deep microfluidic channels and 1.16% for the 90 mum deep fiber channel. The imprinted positive relief in PMMA from master-to-master is reproducible with relative standard deviations (RSDs) of 1.06% for the maximum width and 0.46% for depth in terms of the separation channel. The PDMS devices fabricated from the PMMA replica masters were characterized and applied to the separation of a fluorescein isothiocyanate (FITC)-labeled epinephrine sample.

Dimethylpolysiloxanes↗

Spatial resolution improvement of scanning microscopy based on thermal lens spectroscopy with a total-internal-reflection arrangement.

In scanning microscopy by total internal reflection with thermal lens spectroscopy, its spatial resolution depends on the distance between the sample and a converging lens, which corresponds to the objective lens in an ordinary optical microscope. It was found that the resolution was best when the signal induced by the thermal lens effect was maximum. The distance was precisely adjusted by monitoring the signal intensity, and the resolution became twice better than that previously reported. Using a shorter focal-length lens, a resolution of 1.9 microm was attained.

Journal Article↗

Chiral separation of NBD-amino acids by ligand-exchange micro-channel electrophoresis.

The chiral separation of amino acid derivatives by ligand-exchange electrophoresis in a microchannel chip was performed for the first time. A Cu(II) complex with L-prolinamide was used as a chiral selector. The migration behaviors of eleven NBD-DL-amino acids were investigated by ligand-exchange capillary electrophoresis (LE-CE). The enantiomer of five NBD-amino acids (Ser, Thr, Val, Phe and His) could be separated by LE-CE using a 20 mM ammonium acetate buffer (pH 9.0) containing 10 mM copper acetate, 20 mM L-prolinamide and 1 mM SDS. NBD-His was eluted in the order D-form and L-form, while the elution order of another enantiomers was L-form and D-form. Under this condition, the enantioseparation of these five NBD-amino acids by ligand-exchange microchip electrophoresis (LE-ME) was investigated using a glass microchip. The enantioseparation of NBD-Ser, -Thr and -His could be successfully accomplished by LE-ME. LE-ME was superior to LE-CE in terms of the short migration time and a good enantiomeric separation.

4-Chloro-7-nitrobenzofurazan↗

Detection method for microchip separations.

The features of analytical systems utilizing microfluidic devices, especially detection methods, are described. Electrochemical detection (EC), laser-induced fluorescence (LIF), mass spectrometry (MS), and chemical luminescence (CL) methods are covered. EC enables detection without labeling and has been used in recent years because of its low cost and sensitivity. LIF is the most generally used detection method in microchip separations. Use of LED as an excitation source for fluorescence measurement was also developed for the purpose of miniaturization of the entire system, including detection and separation. Although MS enables highly sensitive analysis, the interface between MS and micro channels is still under examination. This review with fifty-two references introduces interesting detection methods for microchip separations. Related separation methods using microfluidic devices are also discussed.

Journal Article↗

Development of a hyperpolarized 129Xe system on 3T for the rat lungs.

MRI (magnetic resonance imaging) with 129Xe has gained much attention as a diagnostic methodology because of its affinity for lipids and possible polarization. The quantitative estimation of net detectability and stability of hyperpolarized 129Xe in the dissolved phase in vivo is valuable to the development of clinical applications. The goal of this study was to develop a stable hyperpolarized 129Xe experimental 3T system to statistically analyze the dissolved-phase 129Xe signal in the rat lungs. The polarization of 129Xe with buffer gases at the optical pumping cell was measured under adiabatic fast passage against the temperature of an oven and laser absorption at the cell. The gases were insufflated into the lungs of Sprague-Dawley rats (n = 15, 400-550 g) through an endotracheal tube under spontaneous respiration. Frequency-selective spectroscopy was performed for the gas phase and dissolved phase. We analyzed the 129Xe signal in the dissolved phase to measure the chemical shift, T2*, delay and its ratio in a rat lungs on 3T. The polarizer was able to produce polarized gas (1.1+/-0.47%, 120 cm3) hundreds of times with the laser absorption ratio (25%) kept constant at the cell. The optimal buffer gas ratio of 25-50% rendered the maximum signal in the dissolved phase. Two dominant peaks of 211.8+/-0.9 and 201.1+/-0.6 ppm were observed with a delay of 0.4+/-0.9 and 0.9+/-1.0 s from the gas phase spectra. The ratios of their average signal to that of the gas phase were 5.6+/-5.2% and 4.4+/-4.7%, respectively. The T2* of the air space in the lungs was 2.5+/-0.5 ms, which was 3.8 times shorter than that in a syringe. We developed a hyperpolarized 129Xe experimental system using a 3T MRI scanner that yields sufficient volume and polarization and quantitatively analyzed the dissolved-phase 129Xe signal in the rat lungs.

Administration, Inhalation↗

A compactly integrated laser-induced fluorescence detector for microchip electrophoresis.

A simple and easy-to-use integrated laser-induced fluorescence detector for microchip electrophoresis was constructed and evaluated. The fluid channels and optical fiber channels in the glass microchip were fabricated using standard photolithographic techniques and wet chemical etching. A 473 nm diode-pumped laser was used as the excitation source, and the collimation and collection optics and mirrors were discarded by using a multimode optical fiber to couple the excitation light straight into the microchannel and placing the microchip directly on the top of the photomultiplier tube. A combination of filter systems was incorporated into a poly(dimethylsiloxane) layer, which was reversibly sealed to the bottom of the microchip to eliminate the scattering excitation light reaching to the photomultiplier tube. Fluorescein/calcein samples were taken as model analytes to evaluate the performance with respect to design factors. The detection limits were 0.05 microM for fluorescein and 0.18 microM for calcein, respectively. The suitability of this simple detector for fluorescence detection was demonstrated by baseline separation of fluorescein isothiocyanate (FITC)-labeled arginine, phenylalanine, and glycine and FITC within 30 s at separation length of 3.8 cm and electrical field strength of 600 V/cm.

Amino Acids↗

Development of a scanning microscopy by total internal reflection coupled with thermal lens spectroscopy.

Non-destructive measurement of a small region on a solid/liquid interface is of great importance in physical chemistry and biochemistry, especially in the research of thin films and cell membranes. Optical methods for surface analysis with high lateral resolution are suitable methods for monitoring them. We now report a new scanning optical microscopic method to which total internal reflection coupled with a thermal lens technique was introduced. Its lateral resolution was estimated both experimentally and theoretically. To experimentally estimate the resolution, the grid patterns of thin photoresist films with well-defined lateral structures were measured. The experimental resolution was about 45 microm, which was almost same as the diameter of the excitation beam at a glass/sample interface. From this result, it was verified that this new scanning microscopy ideally worked.

Journal Article↗

Comparison of enantioseparations using Cu(II) complexes with L-amino acid amides as chiral selectors or chiral stationary phases by capillary electrophoresis, capillary electrochromatography and micro liquid chromatography.

In this paper we report that Cu(II) complexes with L-amino acid amides were used as chiral selectors for enantioseparation by capillary electrophoresis, capillary electrochromatography (CEC) and micro liquid chromatography using chemically modified monolithic columns. The enantioselectivity, enantiomer migration order, and the performance have been compared when different chiral selectors were used in these modes. L-Enantiomers showed longer retention times than D-forms in both CEC and LC modes. However, it has interestingly been observed that the migration order of Dns-DL-Ser showed an exception in CEC using L-prolinamide-modified column that Dns-L-Ser was eluted as the first peak. On the basis of proposed structures of complexes in the chiral recognition, differences in migration orders and recognition mechanism were discussed.

Amides↗

Cyclodextrin-modified monolithic columns for resolving dansyl amino acid enantiomers and positional isomers by capillary electrochromatography.

We describe beta- and gamma-cyclodextrins (beta- and gamma-CD)-modified monolithic columns prepared by sol-gel process and chemical modifications. The monolithic silica column was fabricated inside a fused-silica capillary with 100 microm inner diameter by sol-gel process. The monolithic silica matrix was chemically modified chiral selectors of beta- or gamma-CDs with a spacer of 3-glycidoxypropyltrimethoxysilane by on-column reactions. Gamma-CD-modified monolithic column has successfully been applied for the separation of dansyl amino acid enantiomers. Beta-CD-modified monolithic column has been used for the separation of the positional isomers of o-, m-, and p-cresols and the enantioseparation of racemates of benzoin and several dansyl amino acids by capillary electrochromatography, respectively. For the separation of neutral positional isomers, a positive electric field was applied. However, for the separation of negatively charged analytes, a negative electric field was applied at the inlet of column. The separation efficiency of 5.0 x 10(4) theoretical plates/m for dansyl-L-threonine was obtained at electric field strength of -300 V/cm in the mobile phase of 50 mM 2-(N-morpholino)ethanesulfonic acid (MES)-Tris/methanol (70/30) buffer at pH 7.0. L-enantiomers were eluted as the first peak. Scanning electron micrograph showed that monolithic columns have the morphology of continuous skeleton and large through-pores.

Amino Acids↗

Monitoring nano-flow rate of water by atomic emission detection using helium radio-frequency plasma.

Recently, high-performance nano-scale flow pumping systems have been developed for micro and miniaturized analysis systems. A novel device capable of measuring and monitoring nanoliter scale flow rates has been required for the further development of the pumping system. In this study, an atomic emission detector using helium radio-frequency plasma (RFP-AED) was used for the measurement of the nanoliter scale flow rate of water by quantitatively detecting the emission from hydrogen in the water molecules. Monitoring nano-flow rates of water in the range up to 1.0 microl min(-1), and the change in the flow rate by the indication of the ratio of the emissions of H (656.3 nm) and He (667.8 nm) were successful. At present, the lowest flow rate that could be determined reproducibly was 4 nl min(-1) calculated as five times the standard deviation of the background noise. Additionally, similar evaluations for the deviation of each flow rate by using the RFP-AED and a flow-injection system were produced.

Journal Article↗

Evaluation of lateral resolution of scanning surface microscopy by total internal reflection with thermal lens effect.

We have developed a novel method for in situ and non-destructive surface analyses, or a total internal reflection with thermal lens spectroscopy (TIR-TLS), which has sufficient sensitivity to monitor phenomena in thin films, such as lipid bilayers. In this study, we applied TIR-TLS to microscopy for surface analyses, and we experimentally obtained its lateral resolution using the edge of a chromium film made by a photolithography technique. The obtained resolution was 20 microm, which was 60% of the diameter of an excitation beam at the interface. The estimated resolution with a simple model agreed with the experimental one, and from this model, TIR-TLS microscopy has the same resolution as that of ordinary optical microscopy. The microscopy by TIR-TLS was applied to a sample whose contrast was too weak to be visually seen, and an image of the sample was obtained without any loss of resolution.

Journal Article↗

Chemically modified chiral monolithic silica column prepared by a sol-gel process for enantiomeric separation by micro high-performance liquid chromatography.

In this work a new type of chiral monolith silica column was developed for the chiral separation by micro high-performance liquid chromatography (micro-HPLC). The chiral monolith column with a continuous skeleton and a large through-pore structure was prepared inside a capillary of 100 microm I.D. by a sol-gel process, and chemically modified with chiral selectors, such as L-phenylalaninamide, L-alaninamide and L-prolinamide, on the surface of the monolithic silica column. Based on the principle of ligand exchange, these chiral monolithic columns were successfully used for the separation of dansyl amino acid enantiomers, as well as hydroxy acid enantiomers by micro-HPLC. The chromatographic conditions, the enantioselectivity and the performance of columns are discussed.

Buffers↗

Comparison of three different anionic surfactants for the separation of hydrophobic compounds by nonaqueous capillary electrophoresis.

The effect of the three different surfactants, sodium dodecyl sulfate (SDS), diethylhexyl sodium sulfosuccinate (AOT), and taurodexycholic acid sodium salt (STDC) on the nonaqueous capillary electrophoretic separations of hydrophobic compounds were compared with formamide containing 20 mM K2HPO4 as electrolyte solvent. Separations of all selected uncharged hydrophobic compounds, e.g., p-arylacetophones were shown to be strongly dependent on the kind of surfactant. The electrolyte containing 180 mM SDS provided the best result for the selected samples.

Acetophenones↗

Photo-response assisted enantiomer separations on an azobenzene-modified gamma-cyclodextrin stationary phase in micro-HPLC.

The photo-responses of the retention and enantioseparation of several optical isomers were evaluated using an azobenzene-modified gamma-cyclodextrin stationary phase (Az gamma-CDSP) in micro-HPLC. UV light irradiation induced a decrease in the retention and the chiral selectivity for N-(3,5-dinitrobenzoyl)-1-phenylethylamine (DNBPEA) and N-(3,5-dinitrobenzoyl)-1-(1-naphtylethyl)amine (DNBNEA), while an increase was induced for dansylphenylalanine (DnsPhe) using a mixture of methanol and aqueous phosphate buffer as the mobile phase. No changes in the retention and the enantiomer separation of benzoin were observed with UV light irradiation. The retention behaviors were recovered by visible-light irradiation. It was speculated that the main factor of the change in the retention behavior was a change in the pi-pi interaction due to the azobenzene moiety of the stationary phase with photo-irradiation. Comparing the retention behavior before and after UV light irradiation, a suitable condition for obtaining a better resolution and enantiomer separation would be chosen using Az gamma-CDSP.

Azo Compounds↗