Acoustic response of compliable microvessels containing ultrasound contrast agents.

The existing models of the dynamics of ultrasound contrast agents (UCAs) have largely been focused on an UCA surrounded by an infinite liquid. Preliminary investigations of a microbubble's oscillation in a rigid tube have been performed using linear perturbation, under the assumption that the tube diameter is significantly larger than the UCA diameter. In the potential application of drug and gene delivery, it may be desirable to fragment the agent shell within small blood vessels and in some cases to rupture the vessel wall, releasing drugs and genes at the site. The effect of a compliant small blood vessel on the UCA's oscillation and the microvessel's acoustic response are unknown. The aim of this work is to propose a lumped-parameter model to study the interaction of a microbubble oscillation and compliable microvessels. Numerical results demonstrate that in the presence of UCAs, the transmural pressure through the blood vessel substantially increases and thus the vascular permeability is predicted to be enhanced. For a microbubble within an 8 to 40 microm vessel with a peak negative pressure of 0.1 MPa and a centre frequency of 1 MHz, small changes in the microbubble oscillation frequency and maximum diameter are observed. When the ultrasound pressure increases, strong nonlinear oscillation occurs, with an increased circumferential stress on the vessel. For a compliable vessel with a diameter equal to or greater than 8 microm, 0.2 MPa PNP at 1 MHz is predicted to be sufficient for microbubble fragmentation regardless of the vessel diameter; however, for a rigid vessel 0.5 MPa PNP at 1 MHz may not be sufficient to fragment the bubbles. For a centre frequency of 1 MHz, a peak negative pressure of 0.5 MPa is predicted to be sufficient to exceed the stress threshold for vascular rupture in a small (diameter less than 15 microm) compliant vessel. As the vessel or surrounding tissue becomes more rigid, the UCA oscillation and vessel dilation decrease; however the circumferential stress is predicted to increase. Decreasing the vessel size or the centre frequency increases the circumferential stress. For the two frequencies considered in this work, the circumferential stress does not scale as the inverse of the square root of the acoustic frequency va as in the mechanical index, but rather has a stronger frequency dependence, 1/va.

Acoustics↗

Lateral phase separation in lipid-coated microbubbles.

In the design of lipid-coated microbubble ultrasound contrast agents for molecular imaging and targeted drug delivery, the surface distribution of the shell species is important because it dictates such properties as ligand location, brush coverage, and amount of drug loading. We used a combination of spectroscopy and microscopy techniques to test the prevailing notion that the main phosphatidyl choline (PC) and lipopolymer species are completely miscible within the monolayer shell. NMR spectroscopy showed that the shell composition is roughly equivalent to the bulk lipid ratio. FTIR spectroscopy showed a sharp melting peak corresponding to the main phase-transition temperature of the main PC species, with no observed pretransitions while scanning from room temperature, indicating a single PC-rich ordered phase. Electron and fluorescence microscopy showed a heterogeneous microstructure with dark (ordered) domains and bright (disordered) regions. Domain formation was thermotropic and reversible. Fluorescent labeling of the lipopolymer following shell formation showed that it partitions preferentially into the disordered interdomain regions. The ordered domains, therefore, are composed primarily of PC, and the disordered interdomain regions are enriched in lipopolymer. Phase heterogeneity was observed at all lipopolymer concentrations (0.5 to 20 mol %), and the degree of phase separation increased with lipopolymer content. The composition and temperature dependence of the microstructure indicates that phase separation is driven thermodynamically rather than being a kinetically trapped relic of the shell-formation process. The overall high variation in microstructure, including the existence of anomalous three-phase coexistence, highlights the nonequilibrium (history-dependent) nature of the monolayer shell.

Coated Materials, Biocompatible↗

Ultrasound assessment of angiogenesis in a matrigel model in rats.

Matrigel, a basement membrane extract, has been extensively used in in vivo angiogenesis. Contrast ultrasound imaging (CUI) of implanted Matrigel plugs with (+bFGF) and without basic fibroblast growth factor (-bFGF) was performed 7 and 14 d after implantation, followed by histologic analysis. Statistically significant differences between +bFGF and -bFGF plugs were apparent at d 7 in both plug size and contrast enhancement (both p < 0.05). Histopathology revealed differences in microvessel density (MVD) between +bFGF and -bFGF at d 7 and d 14. A significant correlation between MVD and both power Doppler contrast-enhanced area (r = 0.65, p < 0.05) and fraction of plug enhanced (r = 0.59, p < 0.05) was present. CUI of Matrigel plugs was shown to be a robust method for distinguishing between two different angiogenic states. Ultrasound measurements of blood flow in the plugs correlated with MVD, a histologic technique used to quantify tumor angiogenesis.

Animals↗

Therapeutic effects of paclitaxel-containing ultrasound contrast agents.

Drug delivery vehicles that combine ultrasonic and molecular targeting are shown to locally concentrate a drug in a region-of-interest. The drug delivery vehicles, referred to as acoustically active lipospheres (AALs), are microbubbles surrounded by a shell of oil and lipid. In a region limited to the focal area of ultrasound application, circulating AALs are deflected by radiation force to a vessel wall and can subsequently be fragmented. Ligands targeting the alphavbeta3 integrin are conjugated to the AAL shell and increase in vitro binding by 26.5-fold over nontargeted agents. Toxicity assays demonstrate that paclitaxel-containing AALs exert a greater antiproliferative effect after insonation than free paclitaxel at an equivalent concentration. Lastly, ultrasound and molecular targeting are combined to deliver a model drug to the endothelium and interstitium of chorioallantoic membrane vasculature in vivo.

Animals↗

Observation of contrast agent response to chirp insonation with a simultaneous optical-acoustical system.

Rayleigh-Plesset analysis, ultra-high speed photography, and single bubble acoustical recordings previously were applied independently to characterize the radial oscillation and resulting echoes from a microbubble in response to an ultrasonic pulse. In addition, high-speed photography has shown that microbubbles are destroyed over a single pulse or pulse train by diffusion and fragmentation. In order to develop a single model to characterize microbubble echoes based on oscillatory and destructive characteristics, an optical-acoustical system was developed to simultaneously record the optical image and backscattered echo from each microbubble. Combined observation provides the opportunity to compare predictions for oscillation and echoes with experimental results and identify discrepancies due to diffusion or fragmentation. Optimization of agents and insonating pulse parameters may be facilitated with this system. The mean correlation of the predicted and experimental radius-time curves and echoes exceeds 0.7 for the parameters studied here. An important application of this new system is to record and analyze microbubble response to a long pulse in which diffusion is shown to occur over the pulse duration. The microbubble response to an increasing or decreasing chirp is evaluated using this new tool. For chirp insonation beginning with the lower center frequency, low-frequency modulation of the oscillation envelope was obvious. However, low-frequency modulation was not observed in the radial oscillation produced by decreasing chirp insonation. Comparison of the echoes from similar sized microbubbles following increasing and decreasing chirp insonation demonstrated that the echoes were not time-reversed replicas. Using a transmission pressure of 620 kPa, the -6 dB echo length was 0.9 and 1.1 micros for increasing and decreasing chirp insonation, respectively (P = 0.02). The mean power in the low-frequency portion of the echoes was 8 (mV)2 and 13 (mV)2 for increasing and decreasing chirp insonation, respectively (P = 0.01).

Acoustics↗

Acoustic response from adherent targeted contrast agents.

In ultrasonic molecular imaging, encapsulated micron-sized gas bubbles are tethered to a blood vessel wall by targeting ligands. A challenging problem is to detect the echoes from adherent microbubbles and distinguish them from echoes from nonadherent agents and tissue. Echoes from adherent contrast agents are observed to include a high amplitude at the fundamental frequency, and significantly different spectral shape compared with free agents (p <0.0003). Mechanisms for the observed acoustical difference and potential techniques to utilize these differences for molecular imaging are proposed.

Acoustics↗

Ultrasound radiation force modulates ligand availability on targeted contrast agents.

Radiation force produced by low-amplitude ultrasound at clinically relevant frequencies remotely translates freely flowing microbubble ultrasound contrast agents over distances up to centimeters from the luminal space to the vessel wall in order to enhance ligand-receptor contact in targeting applications. The question arises as to how the microbubble shell might be designed at the molecular level to fully take advantage of such physical forces in targeted adhesion for molecular imaging and controlled therapeutic release. Herein, we report on a novel surface architecture in which the tethered ligand is buried in a polymeric overbrush. Our results, with biotin-avidin as the model ligand-receptor pair, show that the overbrush conceals the ligand, thereby reducing immune cell binding and increasing circulation persistence. Targeted adhesion is achieved through application of ultrasound radiation force to instantly reveal the ligand within a well-defined focal zone and simultaneously bind the ligand and receptor. Our data illustrate how the adhesive properties of the contrast agent surface can be reversibly changed, from stealth to sticky, through the physical effects of ultrasound. This technique can be combined with any ligand-receptor pair to optimize targeted adhesion for ultrasonic molecular imaging.

Animals↗

Application of ultrasound to selectively localize nanodroplets for targeted imaging and therapy.

Lipid-coated perfluorocarbon nanodroplets are submicrometer-diameter liquid-filled droplets with proposed applications in molecularly targeted therapeutics and ultrasound (US) imaging. Ultrasonic molecular imaging is unique in that the optimal application of these agents depends not only on the surface chemistry, but also on the applied US field, which can increase receptor-ligand binding and membrane fusion. Theory and experiments are combined to demonstrate the displacement of perfluorocarbon nanoparticles in the direction of US propagation, where a traveling US wave with a peak pressure on the order of megapascals and frequency in the megahertz range produces a particle translational velocity that is proportional to acoustic intensity and increases with increasing center frequency. Within a vessel with a diameter on the order of hundreds of micrometers or larger, particle velocity on the order of hundreds of micrometers per second is produced and the dominant mechanism for droplet displacement is shown to be bulk fluid streaming. A model for radiation force displacement of particles is developed and demonstrates that effective particle displacement should be feasible in the microvasculature. In a flowing system, acoustic manipulation of targeted droplets increases droplet retention. Additionally, we demonstrate the feasibility of US-enhanced particle internalization and therapeutic delivery.

Blood Vessels↗

Ultrasound radiation force enables targeted deposition of model drug carriers loaded on microbubbles.

A novel drug delivery vehicle that specifically targets using ultrasound radiation force (USRF) and biotin-avidin interactions is presented. Model vehicles consist of avidinated fluorescent nanobeads bound directly to the biotinylated lipid shells of preformed microbubbles. USRF was used to deflect the vehicle from the center of flow to a tube surface in order to facilitate receptor-ligand mediated adhesion. At wall shear stress levels commensurate with venous and arterial flow, USRF was used to direct the vehicles to a biotinylated tube surface. Subsequent high-pressure pulses fragmented the carrier, and molecular interactions induced deposition of the nanobeads on the wall. Targeting of nanobeads to the tube was molecularly specific and dependent on, in order of importance, vehicle concentration, wall shear stress, nanobead size, and insonation time. The observation that portions of the microbubble lipid monolayer shell remain attached to adherent nanobeads is important for future consideration of drug transport mechanisms. This versatile method of delivery is shown to enable targeted deposition of nanoparticles in shear flow and could be modified to carry therapeutic agents for controlled release in targeted delivery applications.

Avidin↗

Asymmetric oscillation of adherent targeted ultrasound contrast agents.

With a lipid shell containing biotin, micron-sized bubbles bound to avidin on a porous and flexible cellulose boundary were insonified by ultrasound. The oscillation of these targeted microbubbles was observed by high-speed photography and compared to the oscillation of free-floating microbubbles. Adherent microbubbles were observed to oscillate asymmetrically in the plane normal to the boundary, and nearly symmetrically in the plane parallel to the boundary, with a significantly smaller maximum expansion in each dimension for bound than free bubbles. With sufficient transmitted pressure, a jet was produced traveling toward the boundary.

Journal Article↗

The effect of size on the acoustic response of polymer-shelled contrast agents.

In this technical note, we study three polymer-shelled microbubble contrast agents manufactured by POINT Biomedical Corporation that have identical shell composition and mean volumetric diameters of 0.74 microm, 0.91 microm and 1.33 microm. We investigate the effect of agent size on the amplitude, frequency and probability of acoustic echoes received in response to five-cycle, 2.25-MHz pulses of varying pressure. We find that the amplitude and frequency response from the three agents is not significantly different. However, significant differences among the agents do exist in the probability of response to acoustic interrogation: at a pressure of 1.06 MPa, an echo from the 1.33 microm agent is 5 times as likely as an echo from the 0.91 microm agent and 18 times as likely as an echo from the 0.74 microm agent. We hypothesize that there exists an effective pressure-dependent threshold diameter above which single polymer-shelled agents respond to acoustic interrogation.

Contrast Media↗

Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow.

OBJECTIVE: We evaluated implanted rat mammary adenocarcinoma tumors during a 5-week period using ultrasound, computed tomography (CT), and histology. MATERIALS AND METHODS: Contrast-enhanced ultrasound with a destruction-replenishment imaging scheme was used to derive estimates of blood volume and flow. These ultrasound-derived measures of microvascular physiology were compared with contrast-enhanced CT-derived measures of perfusion and vascular volume made by the Mullani-Gould formula and Patlak analysis, respectively. RESULTS: The tumor cross-sectional area and necrotic core cross-sectional area determined by the 3 methods were correlated (r>0.8, P<0.001, n=15). The spatial integral of perfusion estimated by CT correlated with the spatial integral of flow from ultrasound (P<0.05). The contrast-enhanced tumor area calculated from the ultrasound analysis was highly correlated with the contrast-enhanced area estimated by CT images (r=0.89, P<0.001, n=15). However, the fraction of the tumor area enhanced by the CT contrast agent was significantly larger than either the fraction enhanced by ultrasound contrast agent or than the viable area as estimated from histology slides. CONCLUSION: Destruction-replenishment ultrasound provides valuable information about the spatial distribution of blood flow and vascular volume in tumors and ultrasound analysis compares favorably with a validated contrast-enhanced CT method.

Adenocarcinoma↗

A new imaging strategy using wideband transient response of ultrasound contrast agents.

High-resolution clinical systems operating near 15 MHz are becoming more available; however, they lack sensitive harmonic imaging modes for ultrasound contrast agent (UCA) detection, primarily due to limited bandwidth. When an UCA is driven to nonlinear oscillation, a very wideband acoustic transient response is produced that extends beyond 15 MHz. We propose a novel strategy using two separate transducers at widely separated frequencies and arranged confocally to simultaneously excite and receive acoustic transients from UCAs. Experiments were performed to demonstrate that this new mode shows similar resolution, higher echo amplitudes, and greatly reduced attenuation compared to transmission at a higher frequency, and superior resolution compared to transmission and reception at a lower frequency. The proposed method is shown to resolve two 200 microm tubes with centers separated by 400 microm. Strong acoustic transients were detected for rarefaction-first 1-cycle pulses with peak-negative pressures above 300 kPa. The results of this work may lead to uses in flow and/or targeted imaging in applications requiring very high sensitivity to contrast agents.

Algorithms↗

High-frequency dynamics of ultrasound contrast agents.

Ultrasound contrast agents enhance echoes from the microvasculature and enable the visualization of flow in smaller vessels. Here, we optically and acoustically investigate microbubble oscillation and echoes following insonation with a 10 MHz center frequency pulse. A high-speed camera system with a temporal resolution of 10 ns, which provides two-dimensional (2-D) frame images and streak images, is used in optical experiments. Two confocally aligned transducers, transmitting at 10 MHz and receiving at 5 MHz, are used in acoustical experiments in order to detect subharmonic components. Results of a numerical evaluation of the modified Rayleigh-Plesset equation are used to predict the dynamics of a microbubble and are compared to results of in vitro experiments. From the optical observations of a single microbubble, nonlinear oscillation, destruction, and radiation force are observed. The maximum bubble expansion, resulting from insonation with a 20-cycle, 10-MHz linear chirp with a peak negative pressure of 3.5 MPa, has been evaluated. For an initial diameter ranging from 1.5 to 5 microm, a maximum diameter less than 8 microm is produced during insonation. Optical and acoustical experiments provide insight into the mechanisms of destruction, including fragmentation and active diffusion. High-frequency pulse transmission may provide the opportunity to detect contrast echoes resulting from a single pulse, may be robust in the presence of tissue motion, and may provide the opportunity to incorporate high-frequency ultrasound into destruction-replenishment techniques.

Contrast Media↗

Influence of lipid shell physicochemical properties on ultrasound-induced microbubble destruction.

We present the first study of the effects of monolayer shell physicochemical properties on the destruction of lipid-coated microbubbles during insonification with single, one-cycle pulses at 2.25 MHz and low-duty cycles. Shell cohesiveness was changed by varying phospholipid and emulsifier composition, and shell microstructure was controlled by postproduction processing. Individual microbubbles with initial resting diameters between 1 and 10 microm were isolated and recorded during pulsing with bright-field and fluorescence video microscopy. Microbubble destruction occurred through two modes: acoustic dissolution at 400 and 600 kPa and fragmentation at 800 kPa peak negative pressure. Lipid composition significantly impacted the acoustic dissolution rate, fragmentation propensity, and mechanism of excess lipid shedding. Less cohesive shells resulted in micron-scale or smaller particles of excess lipid material that shed either spontaneously or on the next pulse. Conversely, more cohesive shells resulted in the buildup of shell-associated lipid strands and globular aggregates of several microns in size; the latter showed a significant increase in total shell surface area and lability. Lipid-coated microbubbles were observed to reach a stable size over many pulses at intermediate acoustic pressures. Observations of shell microstructure between pulses allowed interpretation of the state of the shell during oscillation. We briefly discuss the implications of these results for therapeutic and diagnostic applications involving lipid-coated microbubbles as ultrasound contrast agents and drug/gene delivery vehicles.

Coated Materials, Biocompatible↗

Quantitative evaluation of perfusion and permeability of peripheral tumors using contrast-enhanced computed tomography.

RATIONALE AND OBJECTIVES: Our purpose was to validate contrast-enhanced computed tomography (CECT)-derived quantitative measures of perfusion and permeability against gold standard techniques of fluorescent microspheres and Evan's Blue dye, respectively. MATERIALS AND METHODS: Normal and tumor-bearing (R3230AC) Fischer 344 rats were used. CECT perfusion measurements of normal and tumor tissue were compared with quantitative fluorescent microsphere perfusion measures. CECT permeability measurements from tumors were compared with semiquantitative Evan's Blue Dye permeability estimates. CT images were obtained precontrast and an imaging plane was selected. Serial, stationary images were obtained every 2 seconds for 2 minutes after intravenous bolus of iodinated contrast. Permeability and perfusion were measured by applying Patlak analysis to time-density data from normal tissue or tumor and femoral artery. RESULTS: There was good correlation between fluorescent microsphere and CECT measurements of perfusion (r2 = 0.681, P << 0.001) and between Evan's Blue Dye and CECT measurements of permeability (r2 = 0.873, P = 0.0007). CONCLUSIONS: CECT provides useful, quantifiable measures of perfusion and permeability in peripheral tumors.

Animals↗

High-resolution functional vascular assessment with ultrasound.

In order to improve the resolution of contrast-assisted imaging systems, we have created a high-frequency destruction/contrast replenishment imaging system with a spatial resolution of 160 microm x 160 microm. The system utilizes a 1-MHz cylindrically focused transducer for destruction and a 25-MHz spherically focused transducer for pulse/echo imaging. Speckle tracking and a clutter filter are applied across frames to remove the challenging physiologic motion artifacts that are obtained when imaging with a mechanically scanned transducer. Using a new estimation technique, flow constants proportional to absolute flow rate were estimated from B-mode time-intensity curves (TICs). The in vitro results indicate a correlation between the actual flow velocity and the estimated rate constant. In vivo images are presented showing blood perfusion in the ciliary processes and iris of the rabbit eye. The regions of interest (ROIs) from the ciliary processes yielded slower perfusion compared with the iris, as expected from vascular casts of the microcirculation in this region. Potential applications of this system include high-resolution perfusion assessment in small animals.

Algorithms↗

A method for radiation-force localized drug delivery using gas-filled lipospheres.

We have developed a method using ultrasound and acoustically active lipospheres (AALs) that might be used to deliver bioactive substances to the vascular endothelium. The AALs consist of a small gas bubble surrounded by a thick oil shell and enclosed by an outermost lipid layer. The AALs are similar to ultrasound contrast agents: they can be nondestructively deflected using ultrasound radiation force, and fragmented with high-intensity ultrasound pulses. The lipid-oil complex might be used to carry bioactive substances at high concentrations. An optimized sequence of ultrasound pulses can deflect the AALs toward a vessel wall then disrupt them, painting their contents across the vascular endothelium. This paper presents results from a series of in vitro and ex vivo experiments demonstrating localization of a fluorescent model drug. In experiments using a human melanoma cell (A2085) monolayer, a specific radiation force-fragmentation ultrasound pulse sequence increased cell fluorescence more than 10-fold over no ultrasound or fragmentation pulses alone, and by 50% over radiation force pulses alone. We observe that dye transfer is limited to cells that are in the region of ultrasonic focus, indicating that the application of radiation force pulses to bring the delivery vehicle into proximity with the cell is required for successful adhesion of the vehicle fragments to the cell membrane. We also demonstrate dye transfer from flowing AALs, both in a mimetic vessel and in excised rat cecum. We believe that this method could be successfully used for drug delivery in vivo.

Animals↗