Search PubMed⌕ Search

Biomedical subjects

Karl B Kern

Publications and source records attributed to Karl B Kern.

At least 19 recordsLinked to original sources

Single rescuer cardiopulmonary resuscitation: can anyone perform to the guidelines 2000 recommendations?

BACKGROUND: The Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care recommend that for adult cardiac arrest the single rescuer performs "two quick breaths followed by 15 chest compressions." This cycle is continued until additional help arrives. Previous studies have shown that lay persons and medical students take 16 +/- 1 and 14 +/- 1 s, respectively, to perform these "two quick breaths." The purpose of this study was to determine the time required for trained professional paramedic firefighters to deliver these two breaths and the effects that any increase in the time it takes to perform rescue breathing would have on the number of chest compressions delivered during single rescuer BLS CPR. We hypothesized that trained professional rescuers would also take substantially longer then the Guidelines recommendation for delivering the two rescue breaths before every 15 compressions during simulated single rescuer BLS CPR. METHODS: Twenty-four paramedic firefighters currently certified to perform BLS CPR were evaluated for their ability to deliver the two recommended breaths within 4 s according to the AHA 2000 CPR Guidelines. Alternatively, a simplified technique of continuous chest compression BLS CPR (CCC) was also taught and compared with standard BLS CPR (STD). Without revealing the purpose of the study the paramedics were asked to perform single rescuer BLS CPR on a recording Resusci Anne while being videotaped. RESULTS: The mean length of time needed to provide the "two quick breaths" during STD-CPR was 10 +/- 1 s. The mean number of chest compressions/min delivered with AHA BLS CPR was only 44 +/- 2. Continuous chest compression CPR resulted in 88 +/- 5 compressions delivered per minute (STD versus CCC; p < 0.0001). CONCLUSIONS: Trained professional emergency rescue workers perform rescue breathing somewhat faster than lay rescuers or medical students, but still require two and one half times longer than recommended. The time required to perform these breaths significantly decreases the number of chest compressions delivered per minute. This may affect outcome as experimental studies have shown that more than 80 compressions delivered per minute are necessary for survival from prolonged cardiac arrest.

Allied Health Personnel↗

Ventricular fibrillation waveform characteristics are different in ischemic heart failure compared with structurally normal hearts.

BACKGROUND: For prolonged VF, perfusion of the myocardium by pre-shock chest compressions can improve myocardial readiness for successful defibrillation. Characteristics of the VF waveform correlate with the duration of VF when there is no structural heart disease. A "smart" automated external defibrillator (AED) could therefore analyze the VF waveform, determine if VF has been prolonged, and then direct rescuers to either deliver a shock first or chest compressions first. We hypothesized that ischemic heart failure might alter the waveform content of ventricular fibrillation compared with normal hearts, complicating the determination of VF duration. METHODS: Myocardial infarction was induced by ligating the proximal left coronary artery. Six weeks later, VF was then induced in 10 rats with myocardial infarction and heart failure (MI-CHF) and 9 control rats. Waveforms were analyzed for total signal amplitude, median frequency, dominant frequency and bandwidth (the frequency interval containing 50% of the total amplitude about the median frequency). RESULTS: All of these VF waveform characteristics were altered substantially in MI-CHF rats compared to normal controls. In particular, MI-CHF rats had decreased signal amplitude early in VF (p=0.02), a broader bandwidth (p=0.001) and different frequency characteristics over time (p<0.001). CONCLUSIONS: VF waveforms vary over time in a typical manner among rats with and without ischemic heart failure. However, the time-course and waveform characteristics of ventricular fibrillation are altered in rats with myocardial infarctions and ischemic heart failure compared to normal controls. These findings have important implications regarding the use of waveform analyses to determine the duration of VF.

Animals↗

ST-segment elevation myocardial infarction: recommendations on triage of patients to heart attack centers: is it time for a national policy for the treatment of ST-segment elevation myocardial infarction?

Despite substantial progress in the diagnosis and treatment of acute ST-segment elevation myocardial infarction (STEMI), implementation of this knowledge into routine clinical practice has been variable. It has become increasing clear that primary percutaneous coronary intervention (PCI) is the preferred method of reperfusion if it can be performed in a timely manner. Recent European data suggest that transfer for direct PCI may also be preferable to fibrinolytic therapy. We believe it is time to establish a national policy for treatment of patients with STEMI to develop a coordinated system of care similar to that of the level 1 trauma system.

Electrocardiography↗

Cardiocerebral resuscitation for cardiac arrest.

Survival rates from out-of-hospital cardiac arrest continue to be low despite periodic updates in the Guidelines for Emergency Medical Services and periodic improvements such as the addition of automatic external defibrillators (AEDs). The low incidence of bystander cardiopulmonary resuscitation (CPR), substantial time without chest compressions throughout the resuscitation effort, and a lack of response to initial defibrillation after prolonged ventricular fibrillation contribute to these unacceptably poor results. Resuscitation guidelines are only revised every 5 to 7 years and can be difficult to change because of the lack of randomized controlled trials in humans. Such trials are rare because of a number of logistical difficulties, including the problem of obtaining informed consent. An alternative approach to advancing resuscitation science is for evidence-based demonstration projects in areas that have adequate records, so that one may determine whether the new approach improves survival. This is reasonable because the current guidelines make provisions for deviations under certain local circumstances or as directed by the emergency medical services medical director. A wealth of experimental evidence indicates that interruption of chest compressions for any reason in patients with cardiac arrest is deleterious. Accordingly, a new approach to out-of-hospital cardiac arrest called cardiocerebral resuscitation (CCR) was developed that places more emphasis on chest compressions for witnessed cardiac arrest in adults and de-emphasizes ventilation. There is also emphasis on chest compressions before defibrillation in circulatory phase of cardiac arrest. CCR was initiated in Tucson, Arizona, in November 2003, and in two rural Wisconsin counties in early 2004.

Cardiopulmonary Resuscitation↗

Rescuer fatigue: standard versus continuous chest-compression cardiopulmonary resuscitation.

OBJECTIVES: Continuous chest-compression cardiopulmonary resuscitation (CCC-CPR) has been advocated as an alternative to standard CPR (STD-CPR). Studies have shown that CCC-CPR delivers substantially more chest compressions per minute and is easier to remember and perform than STD-CPR. One concern regarding CCC-CPR is that the rescuer may fatigue and be unable to maintain adequate compression rate or depth throughout an average emergency medical services response time. The specific aim of this study was to compare the effects of fatigue on the performance of CCC-CPR and STD-CPR on a manikin model. METHODS: This was a prospective, randomized crossover study involving 53 medical students performing CCC-CPR and STD-CPR on a manikin model. Students were randomized to their initial CPR group and then performed the other type of CPR after a period of at least two days. Students were evaluated on their performance of 9 minutes of CPR for each method. The primary endpoint was the number of adequate chest compressions (at least 38 mm of compression depth) delivered per minute during each of the 9 minutes. The secondary endpoints were total compressions, compression rate, and the number of breaks taken for rest. The students' performance was evaluated on the basis of Skillreporter Resusci Anne (Laerdal, Wappingers Falls, NY) recordings. Primary and secondary endpoints were analyzed by using the generalized linear mixed model for counting data. RESULTS: In the first 2 minutes, participants delivered significantly more adequate compressions per minute with CCC-CPR than STD-CPR, (47 vs. 32, p = 0.004 in the 1st minute and 39 vs. 29, p = 0.04 in the 2nd minute). For minutes 3 through 9, the differences in number of adequate compressions between groups were not significant. Evaluating the 9 minutes of CPR as a whole, there were significantly more adequate compressions in CCC-CPR vs. STD-CPR (p = 0.0003). Although the number of adequate compressions per minute declined over time in both groups, the rate of decline was significantly greater in CCC-CPR compared with STD-CPR (p = 0.0003). The mean number of total compressions delivered in the first minute was significantly greater with CCC-CPR than STD-CPR (105 per minute vs. 58 per minute, p < 0.001) and did not change over 9 minutes in either group. There were no differences in compression rates or number of breaks between groups. CONCLUSIONS: CCC-CPR resulted in more adequate compressions per minute than STD-CPR for the first 2 minutes of CPR. However, the difference diminished after 3 minutes, presumably as a result of greater rescuer fatigue with CCC-CPR. Overall, CCC-CPR resulted in more total compressions per minute than STD-CPR during the entire 9 minutes of resuscitation.

Adult↗

Interruptions of chest compressions during emergency medical systems resuscitation.

BACKGROUND: Survival after nontraumatic out-of-hospital (OOH) cardiac arrest in Tucson, Arizona, has been flat at 6% (121/2177) for the decade 1992 to 2001. We hypothesized that interruptions of chest compressions occur commonly and for substantial periods during treatment of OOH cardiac arrest and could be contributing to the lack of improvement in resuscitation outcome. METHODS AND RESULTS: Sixty-one adult OOH cardiac arrest patients treated by automated external defibrillator (AED)-equipped Tucson Fire Department first responders from November 2001 through November 2002 were retrospectively reviewed. Reviews were performed according to the code arrest record and verified with the AED printout. Validation of the methodology for determining the performance of chest compressions was done post hoc. The median time from "9-1-1" call receipt to arrival at the patient's side was 6 minutes, 27 seconds (interquartile range [IQR, 25% to 75%], 5 minutes, 24 seconds, to 7 minutes, 34 seconds). An additional 54 seconds (IQR, 38 to 74 seconds) was noted between arrival and the first defibrillation attempt. Initial defibrillation shocks never restored a perfusing rhythm (0/21). Chest compressions were performed only 43% of the time during the resuscitation effort. Although attempting to follow the 2000 guidelines for cardiopulmonary resuscitation, chest compressions were delayed or interrupted repeatedly throughout the resuscitation effort. Survival to hospital discharge was 7%, not different from that of our historical control (4/61 versus 121/2177; P=0.74). CONCLUSIONS: Frequent interruption of chest compressions results in no circulatory support during more than half of resuscitation efforts. Such interruptions could be a major contributing factor to the continued poor outcome seen with OOH cardiac arrest.

Adult↗

Better outcome after pediatric defibrillation dosage than adult dosage in a swine model of pediatric ventricular fibrillation.

OBJECTIVES: This study was designed to compare outcome after adult defibrillation dosing versus pediatric dosing in a piglet model of prolonged prehospital ventricular fibrillation (VF). BACKGROUND: Weight-based 2 to 4 J/kg monophasic defibrillation dosing is recommended for children in VF, but impractical for automated external defibrillator (AED) use. Present AEDs can only provide adult shock doses or newly developed attenuated adult doses intended for children. A single escalating energy sequence (50/75/86 J) of attenuated adult-dose biphasic shocks (pediatric dosing) is at least as effective as escalating monophasic weight-based dosing for prolonged VF in piglets, but this approach has not been compared to standard adult biphasic dosing. METHODS: Following 7 min of untreated VF, piglets weighing 13 to 26 kg (19 +/- 1 kg) received either biphasic 50/75/86 J (pediatric dose) or biphasic 200/300/360 J (adult dose) therapies during simulated prehospital life support. RESULTS: Return of spontaneous circulation was attained in 15 of 16 pediatric-dose piglets and 14 of 16 adult-dose piglets. Four hours postresuscitation, pediatric dosing resulted in fewer elevations of cardiac troponin T (0 of 12 piglets vs. 6 of 11 piglets, p = 0.005) and less depression of left ventricular ejection fraction (p < 0.05). Most importantly, more piglets survived to 24 h with good neurologic scores after pediatric shocks than adult shocks (13 of 16 piglets vs. 4 of 16 piglets, p = 0.004). CONCLUSIONS: In this model, pediatric shocks resulted in superior outcome compared with adult shocks. These data suggest that adult defibrillation dosing may be harmful to pediatric patients with VF and support the use of attenuating electrodes with adult biphasic AEDs to defibrillate children.

Age Factors↗

Magnetic resonance imaging during untreated ventricular fibrillation reveals prompt right ventricular overdistention without left ventricular volume loss.

BACKGROUND: Most out-of-hospital ventricular fibrillation (VF) is prolonged (>5 minutes), and defibrillation from prolonged VF typically results in asystole or pulseless electrical activity. Recent visual epicardial observations in an open-chest, open-pericardium model of swine VF indicate that blood flows from the high-pressure arterial system to the lower-pressure venous system during untreated VF, thereby overdistending the right ventricle and apparently decreasing left ventricular size. Therefore, inadequate left ventricular stroke volume after defibrillation from prolonged VF has been postulated as a major contributor to the development of pulseless rhythms. METHODS AND RESULTS: Ventricular dimensions were determined by MRI for 30 minutes of untreated VF in a closed-chest, closed-pericardium model in 6 swine. Within 1 minute of untreated VF, mean right ventricular volume increased by 29% but did not increase thereafter. During the first 5 minutes of untreated VF, mean left ventricular volume increased by 34%. Between 20 and 30 minutes of VF, stone heart occurred as manifested by dramatic thickening of the myocardium and concomitant substantial decreases in left ventricular volume. CONCLUSIONS: In this closed-chest swine model of VF, substantial right ventricular volume changes occurred early and did not result in smaller left ventricular volumes. The changes in ventricular volumes before the late development of stone heart do not explain why defibrillation from brief duration VF (<5 minutes) typically results in a pulsatile rhythm with return of spontaneous circulation, whereas defibrillation from prolonged VF (5 to 15 minutes) does not.

Animals↗

Effects of intravenous arginine vasopressin on epicardial coronary artery cross sectional area in a swine resuscitation model.

Although arginine vasopressin (AVP) has been shown to be a promising drug during cardiopulmonary resuscitation (CPR), concern has been raised about the potential for AVP-mediated vasoconstriction of the coronary arteries. In a prospective, randomized laboratory investigation employing an established porcine model, the effects of AVP on haemodynamic variables, left anterior descending (LAD) coronary artery cross sectional area employing intravascular ultrasound (IVUS), and return of spontaneous circulation were studied. During sinus rhythm, the LAD coronary artery cross sectional area was measured by IVUS at baseline, and 90 s and 5 min after AVP (0.4 U/kg IV). Following a 60 min recovery, ventricular fibrillation was induced. At 4 min, chest compressions were initiated; AVP (0.4 U/kg IV) was injected at 5.5 min, and defibrillation performed at 8 min. LAD coronary artery cross sectional area was measured by IVUS at the pre-arrest baseline, 90 s after drug injection during CPR, and 5 min after return of spontaneous circulation. Compared with baseline, the mid-LAD coronary artery cross sectional area increased significantly (P<.05) 90 s and 5 min after AVP administration (9.2+/-.5mm2 versus 10.7+/-.6mm2 versus 11.7+/-.6mm2, respectively) during normal sinus rhythm. Similarly during ventricular fibrillation and CPR plus AVP, the mid-LAD coronary artery cross sectional area increased at 90 s after AVP compared with baseline (9.5+/-.6mm2 versus 11.0+/-.7mm2; P<.05). Moreover, the cross sectional area increased further 5 min after return of spontaneous circulation (9.5+/-.6mm2 versus 14.0+/-.8mm2, P<.05). In conclusion, in this experimental model with normal coronary arteries, AVP resulted in significantly increased LAD coronary artery cross sectional area during normal sinus rhythm, during ventricular fibrillation with CPR, and after return of spontaneous circulation.

Anatomy, Cross-Sectional↗

Post-shock chest compression delays with automated external defibrillator use.

PRIMARY OBJECTIVE: In a swine model of out-of-hospital ventricular fibrillation (VF) cardiac arrest, we established that automated external defibrillator (AED) defibrillation could worsen outcome from prolonged VF compared with manual defibrillation. Worse outcomes were due to substantial interruptions and delays in chest compressions for AED rhythm analyses and shock advice. In particular, the mean interval from first AED shock to first post-shock compressions was 46+/-6s. We hypothesized that the delay from shock to provision of chest compressions is similar in the out-of-hospital setting. MATERIALS AND METHODS: We conducted a retrospective observational review of AED-treated adult VF cardiac arrest victims over a 26-month period to determine the interval from the first AED defibrillation attempt to the initial provision of post-shock chest compressions for out-of-hospital VF cardiac arrests. A two-tiered, single emergency medical service (EMS) system with AED-equipped first responders serves our area of 400 km2 with a population of 487,000 people. The defibrillators record a detailed sequence of events during the resuscitation effort that includes the electrocardiogram with real clock times and a recording of surrounding audible actions. RESULTS: A median of 38 s (IQR 15, 61 s) elapsed between the first shock and the initiation of chest compressions. Approximately half of the delay was due to mechanical/electronic factors and the remainder due to human factors. Of 64 adults in VF, 45 (70%) died before hospital admission, 19 (30%) survived to admission and 10 (16%) survived to hospital discharge. CONCLUSION: Substantial delays in the provision of post-shock chest compressions are typical in this EMS system with AED-equipped first responders.

Adult↗

An alternative approach to advancing resuscitation science.

Stagnant survival rates in out-of-hospital cardiac arrest remain a great impetus for advancing resuscitation science. International resuscitation guidelines, with all their advantages for standardizing resuscitation therapeutic protocols, can be difficult to change. A formalized evidence-based process has been adopted by the International Liason Committee on Resuscitation (ILCOR) in formulating such guidelines. Currently, randomized clinical trials are considered optimal evidence, and very few major changes in the Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care are made without such. An alternative approach is to allow externally controlled clinical trials more weight in Guideline formulation and resuscitation protocol adoption. In Tucson, Arizona (USA), the Fire Department cardiac arrest database has revealed a number of resuscitation issues. These include a poor bystander CPR rate, a lack of response to initial defibrillation after prolonged ventricular fibrillation, and substantial time without chest compressions during the resuscitation effort. A local change in our previous resuscitation protocols had been instituted based upon this historical database information.

Cardiopulmonary Resuscitation↗

Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms.

OBJECTIVES: The goal of this study was to determine the magnitude and mechanisms of hemodynamic improvement of an automated, load-distributing band device (AutoPulse, Revivant Corp., Sunnyvale, California) compared with conventional cardiopulmonary resuscitation (C-CPR). BACKGROUND: Improved blood flow during cardiopulmonary resuscitation (CPR) enhances survival from cardiac arrest. METHODS: AutoPulse CPR (A-CPR) and C-CPR were performed on 30 pigs (16 +/- 4 kg) 1 min after induction of ventricular fibrillation. Aortic and right atrial pressures were measured with micromanometers. Regional flows were measured with microspheres; A-CPR and C-CPR were performed with 20% anterior-posterior chest compression, with (n = 10) and without (n = 10) epinephrine. A pressure transducer was advanced down the airways during chest compressions (n = 10), and magnetic resonance imaging (MRI) was performed. RESULTS: AutoPulse CPR improved coronary perfusion pressure (CPP) (aortic - right atrial pressure) without epinephrine (A-CPR 21 +/- 8 mm Hg vs. C-CPR 14 +/- 6 mm Hg, mean +/- SD, p < 0.0001) and with epinephrine (A-CPR 45 +/- 11 mm Hg vs. C-CPR 17 +/- 6 mm Hg, p < 0.0001). AutoPulse CPR improved myocardial flow without epinephrine and cerebral and myocardial flow with epinephrine (p < 0.05). AutoPulse CPR also produced greater myocardial flow at every CPP (p < 0.01). With A-CPR, high airway pressure was noted distal to the carina, which corresponded to an area of airway collapse on MRI, and which was not present with C-CPR. CONCLUSIONS: AutoPulse CPR improved hemodynamics over C-CPR in this pig model. AutoPulse CPR with epinephrine can produce pre-arrest levels of myocardial and cerebral flow. The improved hemodynamics with A-CPR appear to be mediated through airway collapse, which likely impedes airflow and helps maintain higher levels of intrathoracic pressure.

Animals↗

Trials of teaching methods in basic life support (4): comparison of simulated CPR performance at unannounced home testing after conventional or staged training.

This study compares the retention of basic life support (BLS) skills after 6 and 12 months by lay persons trained either in a conventional manner, or using a staged approach. Three classes, each of 2h, were offered to volunteers over a period of 4 months. For the conventional group, the second and third classes consisted of review of skills. Those in the staged group were first taught chest compression alone; chest compression with ventilation in a ratio of 50:5 was introduced at the second class; full standard CPR was taught at the third class. A total of 495 volunteers entered the study, 262 being randomly allocated to conventional training, and 233 to staged training. More of those who received staged training attended a second (78 volunteers) and third class (41 volunteers), compared with those who received conventional training (36 and 17, respectively). The objective of this study, however, was to compare the strategies of the different training methods. A total of 291 volunteers (167 conventional and 124 staged training) were available for unannounced home testing of full conventional CPR 6 months after initial training, and 260 volunteers (135 conventional and 125 staged training) were tested at 12 months. At 6 months, those taught by the staged method were significantly better at time to first compression (P < 0.0001), compression rate (P = 0.024), and hand position (P = 0.0001). At 12 months, those taught by the staged method were significantly better at shouting for help (P = 0.005), time to first compression (P < 0.0001), and compression depth (P = 0.003). Those taught conventionally were significantly better at checking for a carotid pulse at both 6 and 12 months (P < 0.0001). These results suggest that training lay persons in basic life support skills using a staged approach leads to overall better skill retention at 6 and 12 months, and has other advantages including a greater willingness to re-attend follow-up classes.

Adult↗

Attenuated adult biphasic shocks compared with weight-based monophasic shocks in a swine model of prolonged pediatric ventricular fibrillation.

AIM: To compare the safety and efficacy of attenuated adult biphasic shocks with standard monophasic weight-based shocks in a piglet model of prolonged prehospital ventricular fibrillation (VF). BACKGROUND: If attenuated adult shocks are safe and effective for prehospital pediatric VF, automated external defibrillators (AEDs) can be easily adapted for pediatric use. METHODS: After 7 min of untreated VF, piglets were randomized to treatment with attenuated adult biphasic shocks or weight-based monophasic shocks. The attenuated adult biphasic group received 200/300/360 J shocks, attenuated by specialized pediatric electrodes to 51/78/81 J and the monophasic weight-based control group received 2/4/4 J/kg shocks. Forty-eight female piglets were studied, 16 in each of three weight categories: 4 kg (neonatal), 14 kg (younger child) and 24 kg (older child). The primary outcome measures of efficacy and safety were 24h survival with good neurological outcome and post-resuscitation left ventricular ejection fraction (LVEF), respectively. RESULTS: For the 24 kg piglets, attenuated adult biphasic shocks resulted in superior 24 h survival with good neurological outcome (6/8 versus 0/8, P < 0.001) and greater LVEF 4 h post-resuscitation (34 +/- 4% versus 18 +/- 5%, P < 0.05). For the 14 and 4 kg piglets, 24 h survival with good neurological outcome occurred in 7/8 versus 5/8 and 7/8 versus 3/8, respectively, and LVEF 4 h post-resuscitation was 30 +/- 3% versus 36 +/- 6% and 30 +/- 3% versus 22 +/- 4%, respectively. CONCLUSIONS: The escalating attenuated adult biphasic dosage strategy was at least as safe and effective as the standard weight-based monophasic dose over a wide range of weights in this piglet model of prehospital VF. This work supports the concept of using an attenuated adult biphasic dosage in children.

Animals↗

Optimal dosing of dobutamine for treating post-resuscitation left ventricular dysfunction.

OBJECTIVES: This study was designed to determine the optimal dose of dobutamine in the treatment of post-resuscitation left ventricular dysfunction. BACKGROUND: Global left ventricular dysfunction following successful resuscitation from prolonged, ventricular fibrillation cardiac arrest, negatively impacts long-term survival. Dobutamine can overcome this global myocardial stunning. Previous data indicate a dose of 10 mcg/kgmin improves systolic and diastolic function, but markedly increases the heart rate. METHODS: Twenty swine (24 +/- 0.4 kg) were randomized to one of four doses (0, 2, 5, and 7.5 mcg/kgmin) of dobutamine for the treatment of post-resuscitation myocardial dysfunction following 12.5 min of untreated ventricular fibrillation cardiac arrest. Cardiac function was measured at pre-arrest baseline and serially for 6 h post-resuscitation. Left ventricular function was evaluated by contrast ventriculograms, left ventricular pressures, +dP/dt, Tau, -dP/dt, and cardiac output. Myocardial oxygen consumption and myocardial blood flow were measured to assess the functional significance of any dobutamine-mediated heart rate responses. RESULTS: Left ventricular dysfunction was evident at 25 min and peaked 4 h post-resuscitation. Significant (P < 0.05) improvements in ventricular systolic (EF, CO) and diastolic (LVEDP, Tau) function were evident within minutes of dobutamine initiation and persisted at 6h for the 5 and 7.5 mcg/kgmin groups. Tachycardia manifested with all dobutamine doses, but only affected myocardial oxygen consumption significantly (P < 0.05) at the highest dose (7.5 mcg/kgmin). CONCLUSIONS: Dobutamine at 5 mcg/kgmin appears optimal for restoring systolic and diastolic function post-resuscitation without adversely affecting myocardial oxygen consumption.

Analysis of Variance↗

Preliminary in-hospital experience with a fully automatic external cardioverter-defibrillator.

BACKGROUND: Ventricular fibrillation (VF) and ventricular tachycardia (VT) are frequently present as initial rhythms during in-hospital cardiac arrest. Although ample evidence exists to support the need for rapid defibrillation, the response to in-hospital cardiac arrest remains without major advances in recent years. The delay between the arrhythmic event and intervention is still a challenge for clinical practice. OBJECTIVE: To analyze the performance and safety of in-hospital use of a programmable, fully automatic external cardioverter-defibrillator (AECD). METHODS: We conducted a prospective study at the Emergency Department of a university hospital. A total of 55 patients considered to be at risk of sustained VT/VF were included. Patients underwent monitoring of their cardiac rhythm by the AECD. Upon detection of a ventricular tachyarrhythmia, the AECD was programmed to automatically deliver shock therapy. RESULTS: We recorded 19 episodes of VT/VF in 3 patients. The median time between the beginning of the arrhythmia and the first defibrillation was 33.4 s (21-65 s). One episode of spontaneous reversion of VT was documented 20 s after its origin and shock therapy was aborted. The defibrillation success was 94.4% (17/18) for the first shock and 100% (1/1) for the second shock. No case of inappropriate shock discharge was registered during the study period. CONCLUSION: The AECD has the feasibility to combine long-term monitoring with automatic defibrillation safely and effectively. It presents the possibility of providing rapid identification of, and response to, in-hospital ventricular tachyarrhythmias.

Defibrillators↗

Uninterrupted chest compression CPR is easier to perform and remember than standard CPR.

INTRODUCTION: It has long been observed that CPR skills rapidly decline regardless of the modality used for teaching or criteria used for testing. Uninterrupted chest compression CPR (UCC-CPR) is a proposed alternative to standard single rescuer CPR (STD-CPR) for laypersons in witnessed unexpected cardiac arrest in adults. It delivers substantially more compressions per minute and may be easier to remember and perform than standard CPR. METHODS: In this prospective study, 28 medical students were taught STD-CPR and UCC-CPR and then were tested on each method at baseline (0), 6, and 18 months after training. The students' performance for at least 90 s of CPR was evaluated based on video and Laerdal Skillreporter Resusci Anne recordings. RESULTS: The mean number of correct chest compressions delivered per minute trended down over time in STD-CPR (23 +/- 3, 19 +/- 4 , and 15 +/- 3; P = 0.09) but stayed the same in UCC-CPR (43 +/- 9, 38 +/- 7, and 37 +/- 7 = 0.91) at 0, 6, and 18 months, respectively. The mean percentage of chest compressions delivered correctly fell over time in STD-CPR (54 +/- 6%, 35 +/- 6%, and 32 +/- 6%; P = 0.02) but stayed the same in UCC-CPR (34 +/- 5%, 41 +/- 7%, and 38 +/- 8%) at 0, 6, and 18 months, respectively. The number of chest compressions delivered per minute was higher in UCC-CPR at 0, 6, and 18 months (113 versus 44, P < 0.0001; 94 versus 47, P < 0.0001; and 92 versus 44, P < 0.001). The greater number of chest compressions was due to a mean ventilaroty pause of 13-14 s during STD-CPR at all three time points. CONCLUSIONS: Chest compression performance during STD-CPR declined in repeated testing over 18 months whereas there was minimal decline in chest compressions performance on repeated testing of UCC-CPR. In addition, substantially more chest compressions were delivered during UCC-CPR compared to STD-CPR at all time points primarily because of long pauses accompanying rescue breathing.

Adult↗