Search PubMed⌕ Search

Biomedical subjects

Karin Markides

Publications and source records attributed to Karin Markides.

6 recordsLinked to original sources

A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening.

Miniaturized biochemical devices in glass, silicon and polymer materials are starting to find their way from the academic laboratories to real-life applications. However, most attention has been given to miniaturize the downstream functions of various microfluidic systems, leaving the sample introduction and preparation steps to more conventional, bulkier solutions. For point-of-care diagnostics in particular, it becomes crucial to be able to handle complex human samples in a miniaturized format.In this work, we report on a microsystem for on-chip sample preparation that is able to remove blood cells from whole blood. The hybrid system consists of a commercially available membrane filter incorporated into a poly(dimethylsiloxane) (PDMS) casted device. Membrane materials were evaluated on the bases of low nonspecific adsorption of free and protein-bound testosterone as analyte substance. The hybrid system including a hydrophilic polypropylene filter successfully removed blood cells from diluted human whole blood. Surface oxidation was sufficient to make the plasma filtrate flow through the membrane filter and the channel system by capillary force alone and thus no external pumping source was needed.

Biocompatible Materials↗

Imaging of peptide adsorption to microfluidic channels in a plastic compact disc using a positron emitting radionuclide.

A method for studying peptide-surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amounts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isoelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide 68Ga. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide-surface interactions in a wide variety of miniaturised structures and devices.

Adsorption↗

Sediment depth attenuation of biogenic phosphorus compounds measured by 31P NMR.

Being a major cause of eutrophication and subsequent loss of water quality, the turnover of phosphorus (P) in lake sediments is in need of deeper understanding. A major part of the flux of P to eutrophic lake sediments is organically bound or of biogenic origin. This P is incorporated in a poorly described mixture of autochthonous and allochthonous sediment and forms the primary storage of P available for recycling to the water column, thus regulating lake trophic status. To identify and quantify biogenic sediment P and assess its lability, we analyzed sediment cores from Lake Erken, Sweden, using traditional P fractionation, and in parallel, NaOH extracts were analyzed using 31P NMR. The surface sediments contain orthophosphates (ortho-P) and pyrophosphates (pyro-P), as well as phosphate mono- and diesters. The first group of compounds to disappear with increased sediment depth is pyrophosphate, followed by a steady decline of the different ester compounds. Estimated half-life times of these compound groups are about 10 yr for pyrophosphate and 2 decades for mono- and diesters. Probably, these compounds will be mineralized to ortho-P and is thus potentially available for recycling to the water column, supporting further growth of phytoplankton. In conclusion, 31P NMR is a useful tool to asses the bioavailability of certain P compound groups, and the combination with traditional fractionation techniques makes quantification possible.

Environmental Monitoring↗

A feasibility study of solid supported enhanced microdialysis.

For the first time, a solid supported enhanced microdialysis methodology for analysis of neuropeptides is described. The microdialysis samples were, in this study, subsequently collected in fractions, dissolved from the solid particles, dried, and resolved in a formic acid buffer in order to make them suitable for capillary liquid chromatography-mass spectrometry. Different microdialysis flow profiles were evaluated where air-gapped continuous flow was considered most suitable for the solid supported microdialysis mode. Six endogenous neuropeptides were initially used to investigate the feasibility of this enhanced microdialysis methodology. The improved relative recovery obtained from the solid supported enhanced microdialysis was varying from no effect to 10 times higher as compared to ordinary microdialysis. The most efficient enrichment was obtained for luteinizing hormone releasing hormone, which was the largest but also the most hydrophilic of the peptides. In contrast, no significant difference in recovery was observed for Leu-enkephalin being the smallest and the most hydrophobic peptide tested. These results indicate an increased flux and selective uptake of hydrophilic peptides across the membrane and enrichment on the particles in solid supported microdialysis.

Chromatography, High Pressure Liquid↗

Sheathless electrospray from polymer microchips.

In this study, sheathless electrospray from polymer microchips with conducting layer on the emitter tip is described for the first time. The electrospray emitter tips were fabricated directly from the end of the microchips that were made of polycarbonate or poly(methyl methacrylate) with injection molding. A variety of tip shapes and conducting coatings were evaluated using an electrospray time-of-flight mass spectrometer run in the sheathless mode. Stable electrospray was obtained both from hand-polished and machine-milled three-dimensional tips coated with either polymer-embedded gold particles or graphite particles as the conducting layer. Sputtered gold, on the other hand, suffered from poor stability mainly due to bad adhesion to the polymer tip. The durability of the different coatings was confirmed with electrochemical experiments under simulated electrospray conditions. The relative standard deviations of the response received from the ion current of the MS analysis were in the range of 3.5-12%. The detection limit for a standard mixture containing five neuropeptides was lower than 0.5 fmol. The low detection limit makes the emitter tips highly attractive for the analysis of low-abundance biological species.

Electrochemistry↗

Hadamard transform time-of-flight mass spectrometry: a high-speed detector for capillary-format separations.

This work demonstrates that with an intrinsic duty cycle of 50% and spectral storage speeds up to 277 spectra s(-1) Hadamard transform time-of-flight mass spectrometry (HT-TOFMS) is a promising detector for any capillary-format separation that can be coupled to MS by electrospray ionization. Complete resolution of the components of a nine-peptide standard was achieved by coupling pressurized-capillary electrophoresis (pCE) to HT-TOFMS. The addition of pressure to the separation capillary decreased analysis times and stabilized the electrospray ionization source. Pulsed-pressurized injection of reserpine was used to experimentally simulate narrower peaks than those obtained in the pCE. HT-TOFMS was able to sample peaks having widths in the millisecond range.

Electrophoresis, Capillary↗