Search PubMed⌕ Search

Biomedical subjects

Karin E Markides

Publications and source records attributed to Karin E Markides.

At least 19 recordsLinked to original sources

On-line biological sample cleanup for electrospray mass spectrometry using sol-gel columns.

Using a slight overpressure, a urine sample is loaded onto a monolithic photopolymerized sol-gel column that has been derivatized with hydrophobic carbon chains and then the complex urine matrix is washed with aqueous solution. A buffer containing organic solvent is used to elute the adsorbed peptides by an applied voltage and the sample is then introduced into a mass spectrometer by sheath flow electrospray. The importance of desalting this type of sample is demonstrated by an experiment that shows that the signal intensity of a test solution with neurotensin, sprayed directly into the mass spectrometer, decreased from 4.5x10(4) cps to no detectible signal when just 10% urine is added to the sample solution. We suggest that this procedure may find general application for desalting biological samples prior to mass spectrometric analysis.

Chromatography, Liquid↗

A simplified multidimensional approach for analysis of complex biological samples: on-line LC-CE-MS.

Information on protein expression, disease biomarkers or surrogate markers and genetic disorders can nowadays be achieved from analysis of complex biological samples by liquid separation coupled to mass spectrometric (MS) detection. This paper describes fast multidimensional separation by on-line liquid chromatography (LC) and capillary electrophoresis (CE), followed by electrospray ionization (ESI) Fourier transform ion cyclotron resonance (FTICR) MS detection. This detector provides ultrahigh resolution of the detected ions, mass accuracy at the ppm-level and high sensitivity. Most of the challenge of this system lies in the development of a new interface for the on-line coupling of LC to CE. The interface developed in poly(dimethylsiloxane) provides a RSD for injection repeatability of <3.5% and surface control for unspecific binding by deactivation with a cationic polymer, PolyE-323. We have evaluated the interface, as well as the overall system, with respect to robustness and deconvolution ability. Sequence coverage for bovine serum albumin (BSA) of 93% showed a high recovery of sample in the different transfer steps through the system. The detection limit for identification is 277 ng mL(-1) (or 280 nM) on average for peptides. In the future, we expect LC-CE-MS to be a novel strategy for elucidating the chemistry of biological matrices.

Animals↗

Noncovalent interaction between amyloid-beta-peptide (1-40) and oleuropein studied by electrospray ionization mass spectrometry.

Beta amyloid peptide (Abeta) is the major proteinaceous component of senile plaques formed in Alzheimer's disease (AD) brain. The aggregation of Abeta is associated with neurodegeneration, loss of cognitive ability, and premature death. It has been suggested that oxidative stress and generation of free radical species have implications in the fibrillation of Abeta and its subsequent neurotoxicity. For this reason, it is proposed that antioxidants may offer a protective or therapeutic alternative against amyloidosis. This study is the first report of the formation of the noncovalent complex between Abeta or its oxidized form and the natural derived antioxidant oleuropein (OE) by electrospray ionization mass spectrometry (ESI MS). ESI MS allowed the real time monitoring of the complex formation between Abeta, OE, and variants thereof. Several experimental conditions, such as elevated orifice potential, low pH values, presence of organic modifier, and ligand concentration were examined, to assess the specificity and the stability of the formed noncovalent complexes.

Amyloid beta-Peptides↗

Screening of microdialysates taken before and after induced liver damage; on-line solid phase extraction-electrospray ionization-mass spectrometry.

A novel method is described to follow known and unknown compounds in biological processes using microdialysis sampling and mass spectrometric detection. By implementation of internal standard, desalting/enrichment for the sample work-up, and multivariate data analysis, this methodology is a basis for future applications in early diagnosis of diseases and organ damage, as a complement to the routinely used clinical methods for biological samples. The present study includes screening without specific target analytes, of samples collected by microdialysis from liver of anaesthetized rats before and after local damage to this organ. Sample series were classified by principal component analysis, and the stimulation was identified in the chemical patterns produced by the presented analytical tool.

Animals↗

Relating chromatographic retention and electrophoretic mobility to the ion distribution within electrosprayed droplets.

Ions that are observed in a mass spectrum obtained with electrospray mass spectrometry can be assumed to originate preferentially from ions that have a high distribution to the surface of the charged droplets. In this study, a relation between chromatographic retention and electrophoretic mobility to the ion distribution (derived from measured signal intensities in mass spectra and electrospray current) within electrosprayed droplets for a series of tetraalkylammonium ions, ranging from tetramethyl to tetrapentyl, is presented. Chromatographic retention in a reversed-phase system was taken as a measure of the analyte's surface activity, which was found to have a large influence on the ion distribution within electrosprayed droplets. In addition, different transport mechanisms such as electrophoretic migration and diffusion can influence the surface partitioning coefficient. The viscosity of the solvent system is affected by the methanol content and will influence both diffusion and ion mobility. However, as diffusion and ion mobility are proportional to each other, we have, in this study, chosen to focus on the ion mobility parameter. It was found that the influence of ion mobility relative to surface activity on the droplet surface partitioning of analyte ions decreases with increasing methanol content. This effect is most probably coupled to the decrease in droplet size caused by the decreased surface tension at increasing methanol content. The same observation was made upon increasing the ionic strength of the solvent system, which is also known to give rise to a decreased initial droplet size. The observed effect of ionic strength on the droplet surface partitioning of analyte ions could also be explained by the fact that at higher ionic strength, a larger number of ions are initially closer to the droplet surface and, thus, the contribution of ionic transport from the bulk liquid to the liquid/air surface interface (jet and droplet surface), attributable to migration or diffusion will decrease.

Chromatography, Liquid↗

Poly(dimethylsiloxane)-based microchip for two-dimensional solid-phase extraction-capillary electrophoresis with an integrated electrospray emitter tip.

A microchip in poly(dimethylsiloxane) (PDMS) for in-line solid-phase extraction-capillary electrophoresis-electrospray ionization-time-of-flight mass spectrometry (SPE-CE-ESI-TOF-MS) has been developed and evaluated. The chip was fabricated in a novel one-step procedure where mixed PDMS was cast over steel wires in a mold. The removed wires defined 50-microm cylindrical channels. Fused-silica capillaries were inserted into the structure in a tight fit connection. The inner walls of the inserted fused-silica capillaries and the PDMS microchip channels were modified with a positively charged polymer, PolyE-323. The chip was fabricated in a two-level cross design. The channel at the lower level was packed with 5-microm hyper-cross-linked polystyrene beads acting as a SPE medium used for desalting. The upper level channel acted as a CE channel and ended in an integrated emitter tip coated with conducting graphite powder to facilitate the electrical contact for sheathless ESI. An overpressure continuously provided fresh CE electrolyte independently of the flows in the different levels. Further studies were carried out in order to investigate the electrophoretic and flow rate properties of the chip. Finally, six-peptide mixtures, in different concentrations, dissolved in physiological salt solution was injected, desalted, separated, and sprayed into the mass spectrometer for analysis with a limit of detection in femtomole levels.

Amino Acid Sequence↗

Total lipid extraction of homogenized and intact lean fish muscles using pressurized fluid extraction and batch extraction techniques.

The reliability and efficiency of pressurized fluid extraction (PFE) technique for the extraction of total lipid content from cod and the effect of sample treatment on the extraction efficiency have been evaluated. The results were compared with two liquid-liquid extraction methods, traditional and modified methods according to Jensen. Optimum conditions were found to be with 2-propanol/n-hexane (65:35, v/v) as a first and n-hexane/diethyl ether (90:10, v/v) as a second solvent, 115 degrees C, and 10 min of static time. PFE extracts were cleaned up using the same procedure as in the methods according to Jensen. When total lipid yields obtained from homogenized cod muscle using PFE were compared yields obtained with original and modified Jensen methods, PFE gave significantly higher yields, approximately 10% higher (t test, P < 0.05). Infrared and NMR spectroscopy suggested that the additional material that inflates the gravimetric results is rather homogeneous and is primarily consists of phospholipid with headgroups of inositidic and/or glycosidic nature. The comparative study demonstrated that PFE is an alternative suitable technique to extract total lipid content from homogenized cod (lean fish) and herring (fat fish) muscle showing a precision comparable to that obtained with the traditional and modified Jensen methods. Despite the necessary cleanup step, PFE showed important advantages in the solvent consumption was cut by approximately 50% and automated extraction was possible.

2-Propanol↗

Polyamine deactivation of integrated poly(dimethylsiloxane) structures investigated by radionuclide imaging and capillary electrophoresis experiments.

The poly(dimethylsiloxane) (PDMS) material provides a number of advantageous features, such as flexibility, elasticity, and transparency, making it useful in integrated analytical systems. Hard fused-silica capillary structures and soft PDMS channels can easily be combined by a tight fit, which offers many alternatives for structure combinations. PDMS and fused silica are in different ways prone to adsorption of low levels of organic compounds. The need for modification of the inner wall surface of PDMS channels may often be necessary, and in this paper, we describe an easy and effective method using the amine-containing polymer PolyE-323 to deactivate both fused-silica and PDMS surfaces. The adsorption of selected peptides to untreated surfaces was compared to PolyE-323-modified surfaces, using both radionuclide imaging and capillary electrophoresis experiments. The polyamine modification displayed a substantially reduced adsorption of three hydrophobic test peptides compared to the native PDMS surface. Filling and storage of aqueous solution were also possible in PolyE-323-modified PDMS channels. In addition, hybrid microstructures of fused silica and PDMS could simultaneously be deactivated in one simple coating procedure.

Adsorption↗

Capillary electrophoresis coupled to mass spectrometry from a polymer modified poly(dimethylsiloxane) microchip with an integrated graphite electrospray tip.

Hybrid capillary-poly(dimethysiloxane)(PDMS) microchips with integrated electrospray ionization (ESI) tips were directly fabricated by casting PDMS in a mould. The shapes of the emitter tips were drilled into the mould, which produced highly reproducible three-dimensional tips. Due to the fabrication method of the microfluidic devices, no sealing was necessary and it was possible to produce a perfect channel modified by PolyE-323, an aliphatic polyamine coating agent. A variety of different coating procedures were also evaluated for the outside of the emitter tip. Dusting graphite on a thin unpolymerised PDMS layer followed by polymerisation was proven to be the most suitable procedure. The emitter tips showed excellent electrochemical properties and durabilities. The coating of the emitter was eventually passivated, but not lost, and could be regenerated by electrochemical means. The excellent electrochemical stability was further confirmed in long term electrospray experiments, in which the emitter sprayed continuously for more than 180 h. The PolyE-323 was found suitable for systems that integrate rigid fused silica and soft PDMS technology, since it simply could be applied successfully to both materials. The spray stability was confirmed from the recording of a total ion chromatogram in which the electrospray current exhibited a relative standard deviation of 3.9% for a 30 min run. CE-ESI-MS separations of peptides were carried out within 2 min using the hybrid PDMS chip resulting in similar efficiencies as for fused silica capillaries of the same length and thus with no measurable band broadening effects, originating from the PDMS emitter.

Electrophoresis, Capillary↗

Study of the non-covalent interaction between amyloid-beta-peptide and melatonin using electrospray ionization mass spectrometry.

Oxidative stress and unregulated immune response are believed to play a key role in the processes inherent to Alzheimer's disease (AD). The fact that free radicals can result in neurodegeneration suggests that actions against reactive oxygen species may be beneficial in treating and preventing AD. In the light of the suggested link between oxidative stress and AD, it is proposed that antioxidants and, even more, endogenous antioxidants may offer a therapeutic regime for protection against the risk of this disease. For this reason, the formation of non-covalent complexes between amyloid-beta-peptide (A beta) or its oxidized forms and melatonin was studied by quadrupole and Fourier transform ion cyclotron resonance electrospray ionization mass spectrometry. The stability of the non-covalent complex was examined under several experimental conditions, such as orifice voltage, pH, presence of organic modifier, concentration and time. Two different digestion protocols combined with mass spectrometric analysis of the resulting peptide fragments were employed in order to locate the binding site of melatonin in A beta.

Amino Acid Sequence↗

Multi-parameter investigation of tandem mass spectrometry in a linear ion trap using response surface modelling.

The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment.

Journal Article↗

Radionuclide imaging of miniaturized chemical analysis systems.

We propose radionuclide imaging as a valuable tool for the study of molecular interactions in miniaturized systems for chemical analysis. Sensitive and quantitative imaging can be performed with compounds labeled with short-lived positron-emitting radionuclides, such as (11)C and (68)Ga, within selected parts of the system. Radionuclide imaging is not restricted to transparent materials since the relatively energetic positrons can penetrate high optical density materials. Experimentally, a radiotracer is introduced into the object of study, which is subsequently placed on a phosphor storage plate. After exposure, the plate is scanned with a laser and a digital, quantitative image can be reconstituted. To demonstrate the concept, three types of microstructures suited for integration in chemical analysis systems were imaged with (11)C- and (68)Ga-labeled tracers. The influence of factors such as geometry of the object and type of radionuclide on resolution and sensitivity was investigated. The resolution ranged from 0.9 to 2.7 mm (fwhm). Measuring low amounts of radioactivity in the three structures, 2-20 Bq could be detected, which corresponded to 2.3-500 amol or 2.4-110 pM tracer. The imaging approach was applied to study analyte concentration and sample dilution effects on the performance of a capillary extraction column integrated in an automated LC-ESI-MS system. The utility of the technique was further illustrated by imaging of microchannels in a zeonor plastic compact disk and in a poly(dimethylsiloxane) material for the study of nonspecific peptide adsorption.

Carbon Isotopes↗

Fingerprinting metal-containing biomolecules after reductive displacement of iron by gallium and subsequent column-switched LC-ICPMS analysis applied on siderophores.

Column-switching liquid chromatography followed by low-resolution ICPMS was evaluated as a tool for speciation analysis of metal-containing biomolecules. The strategy was applied on siderophores, strong iron chelators of low molecular weight (M(w) < 1500). Prior to the LC-ICPMS analysis, reductive displacement of iron by gallium was performed using ascorbate as the reducing agent to increase the sensitivity. Different experimental conditions during the exchange reaction were tested using ferrichrysin and ferrichrome for evaluation. A reaction time of 30 min and a pH of 3.9 gave an exchange yield of 27 and 83% for ferrichrysin and ferrichrome, respectively. A gradient elution profile was also developed to separate gallium-chelated siderophores on a PGC column. Detection limits for standard solutions of ferrichrysin and ferrichrome in the low-nanomolar range were obtained by monitoring the gallium-69 isotope. The combined use of LC-ICPMS and LC-ESI-MS/MS was also evaluated as a tool to identify unknown metal complexes, here siderophores, in field soil solution samples.

Ascorbic Acid↗

Quaternary ammonium substituted agarose as surface coating for capillary electrophoresis.

A novel positively charged polymer of quaternary ammonium substituted agarose (Q-agarose) has been synthesized and explored for use as a coating in capillary electrophoresis. The fast and simple coating procedure is based on a multi-site electrostatic interaction between the polycationic agarose polymer and the negatively charged fused-silica surface. By simply flushing fused-silica capillaries with hot polymer solution a positively charged, hydrophilic deactivation layer is achieved. The polymer surface provides an intermediate electroosmotic flow of reversed direction, over a range of pH 2-11, compared to unmodified fused-silica. The coating procedure was highly reproducible with an RSD of 4%, evaluated as the electroosmotic flow mobility for 30 capillaries prepared at 10 different occasions. The application of Q-agarose coated capillaries in separation science was investigated using a set of basic drugs and model proteins and peptides. Due to the intermediate electroosmotic flow generated, the resolution of basic drugs could be increased, compared to using bare fused-silica capillaries. Moreover, the coating enabled separation of proteins and peptides with efficiencies up to 300.000 plates m(-1).

Electrophoresis, Agar Gel↗

Analysis of catecholamines and related substances using porous graphitic carbon as separation media in liquid chromatography-tandem mass spectrometry.

Capillary porous graphitic carbon (PGC) columns have been utilized for separation of several catecholamines and related compounds (i.e. L-tyrosine, L-DOPA, 3-O-methyl-DOPA, dopamine, 3,4-dihydroxy-phenyl-acetic acid (DOPAC), homovanillic acid, noradrenaline, vanillomandelic acid and adrenaline) on-line with electrospray ionization tandem mass spectrometry (ESI-MS/MS). The use of a mobile phase without ion-pairing agents and with high content of organic modifier facilitated the coupling to the selective and sensitive mass spectrometric detection. Minimum detectable sample concentration (MDC sample) for noradrenaline, dopamine and L-tyrosine in a standard solution was estimated to 3, 10 and 30 nM, respectively (3 S/N corresponds to MDQ for L-tyrosine of approximately 8 x 10(-14)mol). The developed strategy was applied for analysis of brain tissue, i.e. a substantia nigra (ns) sample.

3,4-Dihydroxyphenylacetic Acid↗

A new multi-residue method for analysis of pesticide residues in fruit and vegetables using liquid chromatography with tandem mass spectrometric detection.

A new multi-residue method for determination of pesticide residues in a wide variety of fruit and vegetables, using the National Food Administration (NFA) ethyl acetate extraction and determination by means of LC-MS/MS, is presented. The method includes pesticides normally detected by LC-UV or LC-fluorescence such as benzimidazoles, carbamates, N-methylcarbamates and organophosphorus compounds with an oxidisable sulphide group as well. After extraction with ethyl acetate, the extract is concentrated and an aliquot of the extract is evaporated to dryness and redissolved in methanol before injection on LC-MS/MS. The method has been validated for 57 different pesticides and metabolites. Representative species from different commodity groups were chosen as matrices in order to study the influence from different matrices on recoveries. The fortification levels studied were 0.01-0.5 mg kg(-1). Matrix effects were tested for all matrices by means of standard addition to blank extracts. The matrix effect, expressed as signal in solvent compared to signal in matrix, was in general found to be small. The obtained recoveries are, with a few exceptions, in the range 70-100%. The proposed method is quick and straightforward and no additional clean-up steps are needed. The method can be used for the analysis of all 57 pesticides in one single determination step at 0.01 mg kg(-1).

Chromatography, Liquid↗

Monomer surface modifications for rapid peptide analysis by capillary electrophoresis and capillary electrochromatography coupled to electrospray ionization-mass spectrometry.

In this study, positively charged alkylaminosilyl monomers were used to modify the inner surface of fused silica capillaries, which subsequently were employed in capillary electrophoresis (CE) and capillary electrochromatography (CEC). The obtained surfaces yield a reversed electroosmotic flow (EOF) and have varying carbon chain lengths, that interact with the analytes and give chromatographic retention. The coating procedure is very simple and fast. The performance of the modified capillaries was evaluated regarding pH influence on EOF and chromatographic interactions. The experiments were conducted with UV and mass spectrometry (MS) and applied to the separation of various neuropeptides. The derivatized surfaces showed a linear (R(2) approximately 0.99) pH dependence with isoelectric points (pI) at 8.6-8.8. Rapid separations of peptide standards and a protein digest with efficiencies as high as 5 x 10(5) plates/m were performed.

Chromatography↗

A polyamine coating for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry of proteins and peptides.

A procedure for enhanced capillary electrophoresis-electrospray ionization-mass spectrometry (CE-ESI-MS) of proteins is presented. The use of a newly presented capillary coating, PolyE-323, provided fast separations of typically a few minutes with high efficiency, good deactivation, and no bleeding into the mass spectrometer. Capillaries coated with PolyE-323 showed high stability over a range of pH 2-10, and tolerance towards methanol and acetonitrile, two modifiers commonly used in CE-ESI-MS. Due to the speed and simplicity of the coating procedure, the polymeric surface could, if necessary, easily be regenerated. This capability is especially valuable when working with samples of complex matrix, where a capillary surface cleaning step might be desired in order to eliminate possible memory effects. The potential of PolyE-323-coated capillaries in bioanalysis using CE-ESI-MS was demonstrated by analyzing peptides and proteins up to 66 kDa using time of flight (TOF)-MS. Due to the stable, anodal electroosmotic flow generated by the coating, the use of a sheathless ESI interface was enabled, demonstrated in peptide analysis with attomole sensitivity. The fast on-line CE-ESI-TOF system using PolyE-323-coated capillaries provided efficient separation and detection of a large number of peaks in a short time, exemplified by the analysis of a tryptic digest of bovine serum albumin (BSA). The capability of the developed capillary surface coating was demonstrated by the separation of human plasma and cerebrospinal fluid (CSF).

Acetonitriles↗