Search PubMed⌕ Search

Biomedical subjects

Karen W Phinney

Publications and source records attributed to Karen W Phinney.

13 recordsLinked to original sources

Determination of ephedrine alkaloid stereoisomers in dietary supplements by capillary electrophoresis.

Three complementary capillary electrophoresis (CE) methods were developed for the separation and quantification of ephedrine and pseudoephedrine stereoisomers. Either single or dual cyclodextrin-based chiral selector systems provided enantioselective separation of the compounds of interest. The three methods were applied to the analysis of a suite of five standard reference materials (SRMs) containing ephedra. Use of a high-sensitivity UV detection cell enhanced quantification of the analytes of interest over the wide range of concentrations encountered in the SRMs. Results for (-)-ephedrine ranged from 0.31 to 76.43 mg/g, and for (+)-pseudoephedrine ranged from 0.049 to 9.23 mg/g in the materials studied. Results from the three methods agreed well with each other and with the results from other methods of analysis. The addition of known amounts of specific enantiomers was used to confirm the enantiomeric identity of the analytes. The results obtained by the three CE methods were utilized for value assignment of the ephedrine alkaloid content of these five SRMs.

Alkaloids↗

Determination of ephedrine alkaloids in dietary supplement standard reference materials.

A suite of five ephedra-containing dietary supplement Standard Reference Materials (SRMs) has been issued by the National Institute of Standards and Technology (NIST) with certified values for ephedrine alkaloids, synephrine, caffeine, and selected toxic trace elements. The materials represent a variety of natural, extracted, and processed sample matrixes that provide different analytical challenges. The constituents have been determined by multiple independent methods with measurements performed by NIST and by three collaborating laboratories. The methods utilized different sample extraction and cleanup steps in addition to different instrumental analytical techniques and approaches to quantification. In addition, food-matrix proximates were determined by National Food Processor Association laboratories for one of the ephedra-containing SRMs. The SRMs are primarily intended for method validation and for use as control materials to support the analysis of dietary supplements and related botanical materials.

Alkaloids↗

Reversed-phase liquid chromatography and argentation chromatography of the minor capsaicinoids.

An investigation of the liquid chromatography of the minor capsaicinoids in a commercial capsaicinoid mixture is reported. Twelve stationary phases including C8, C18, C30, phenyl, and cation-exchange chemistries were examined in combination with isocratic aqueous methanol and aqueous acetonitrile mobile phases. A phenyl stationary phase and aqueous acetonitrile mobile phase baseline-resolved 7 of 11 capsaicinoids, and selected ion chromatograms (LC-ESI-MS) demonstrated this was the most effective reversed-phase separation. Argentation chromatography with an alkyl or phenyl column and aqueous silver nitrate-methanol mobile phase revealed the presence of the 6-ene-8-methyl and 6-ene-9-methyl homocapsaicin isomers and the absence of 7-ene-9-methyl homocapsaicin. A mixed phenyl-cation-exchange stationary phase (charged with silver ion) enabled unique and useful separations of the capsaicinoids.

Capsaicin↗

Quantitative determination of capsaicinoids by liquid chromatography-electrospray mass spectrometry.

Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography-ESI-mass spectrometry (LC-ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20-6 ng injected), quantitation (excellent linearity; < 2% relative standard deviation), and recovery (99-103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.

Capsaicin↗

Enantioselective separations by packed column subcritical and supercritical fluid chromatography.

Enantioselective separations have been one of the most successful applications of supercritical fluid chromatography (SFC). Although analytical scale separations have dominated the literature, the use of SFC for preparative chiral separations is growing. Both analytical and preparative scale SFC separations seek to take advantage of the high efficiency, high throughput, and rapid method development associated with the technique. This review will cover recent developments in the application of SFC to enantioseparations.

Chromatography, Liquid↗

Dynamically coated capillaries for enantioselective separations by capillary electrophoresis.

The level of variability in migration times and peak areas often encountered in capillary electrophoresis (CE) has restricted its use for routine analysis. Cationic analytes also tend to interact with the capillary wall, resulting in skewed peak shapes and reduced efficiency. We investigated a dynamic coating procedure that involves a two-step process to modify the capillary and that results in a higher but stable electro-osmotic flow (EOF) at low pH. We compared enantioselective separations of several basic compounds on unmodified and dynamically coated capillaries. A derivatized cyclodextrin was used as the chiral additive. When the dynamic coating was used, peak symmetry improved, and migration times were significantly shorter. The dynamic coating procedure also resulted in improved migration time and peak area precision.

Journal Article↗

Simultaneous concentration and separation of enantiomers with chiral temperature gradient focusing.

A new technique is demonstrated for the simultaneous concentration and high-resolution separation of chiral compounds. With temperature gradient focusing, a combination of a temperature gradient, an applied electric field, and a buffer with a temperature-dependent ionic strength is used to cause analytes to move to equilibrium, zero-velocity points along a microchannel or capillary. Different analytes are thus separated spatially and concentrated in a manner that resembles isoelectric focusing but that is applicable to a greater variety of analytes including small chiral drug molecules. Chiral separations are accomplished by the addition of a chiral selector, which causes the different enantiomers of an analyte to focus at different positions along a microchannel or capillary. This new technique is demonstrated to provide high performance in a number of areas desirable for chiral separations including rapid separation optimization and method development, facile reversal of peak order (desirable for analysis of trace enantiomeric impurities), and high resolving power (comparable to capillary electrophoresis) in combination with greater than 1000-fold concentration enhancement enabling improved detection limits. In addition, chiral temperature gradient focusing allows for real-time monitoring of the interaction of chiral analyte molecules with chiral selectors that could potentially be applied to the study of other molecular interactions. Finally, unlike CE, which requires long channels or capillaries for high-resolution separations, separations of equivalent resolution can be performed with TGF in very short microchannels (mm); thus, TGF is inherently much more suited to miniaturization and integration into lab-on-a-chip-devices.

Buffers↗

Liquid chromatographic method for the determination of enantiomeric composition of amphetamine and methamphetamine in hair samples.

Interest in hair analysis as an alternative or complementary approach to urinalysis for drug abuse detection has grown in recent years. Hair analysis can be particularly advantageous for drugs such as amphetamine and methamphetamine that are rapidly excreted. Confirmation of abuse of these stimulants is complicated by the fact that some forms are found in legitimate medications. Examination of the enantiomeric composition of amphetamine and methamphetamine in hair samples can provide valuable assistance in interpreting drug testing results. In this work, we developed a liquid chromatographic method for the separation of amphetamine and methamphetamine enantiomers isolated from human hair samples. The drug enantiomers were separated on a chiral stationary phase after derivatization with an achiral fluorescent agent. The methodology was evaluated with a Standard Reference Material that contained several drugs of abuse including amphetamine and methamphetamine.

Amphetamine↗

Additive concentration effects on enantioselective separations in supercritical fluid chromatography.

Polar additive concentration effects in supercritical fluid chromatography were studied on chiral stationary phases having either a macrocyclic glycopeptide or a derivatized polysaccharide as the chiral selector. Two basic additives, isopropylamine and triethylamine, were incorporated into the methanol modifier at various concentrations and the effects on retention, selectivity, and resolution were monitored. Many of the analytes failed to elute from the macrocyclic glycopeptide stationary phase in the absence of an additive and the most noticeable effect of increasing additive concentration was a significant decrease in retention. On the derivatized polysaccharide stationary phase the additives had little effect on retention, but they did foster significant improvements in peak shape and resolution.

Journal Article↗

Enantioselective separations in capillary electrophoresis with dextran sulfate as the chiral selector.

Dextran sulfate, a polyanionic polysaccharide, was evaluated as a chiral additive in capillary electrophoresis. Structurally related compounds having a variety of functional groups were utilized to probe the selectivity of the chiral selector. The effects of pH, chiral selector concentration, and chiral selector composition on resolution were also studied. At low pH, the reversed polarity mode was employed to achieve separation of the probe compounds. The electrophoretic results provided insight into the chiral recognition of dextran sulfate in capillary electrophoresis. Several factors, including hydrophobic, steric, and electrostatic interactions, appeared to play a role in the observed enantioseparations.

Dextran Sulfate↗

Chiral recognition of functionalized cyclodextrins in capillary electrophoresis.

The chiral recognition of hydroxypropylated, dimethylated, and sulfated cyclodextrins was evaluated by utilizing them as chiral additives in capillary electrophoresis. Although each selector yielded enantiomeric separations of most of the target analytes, differences were observed in the electrophoretic results for the different derivatized cyclodextrins and for additives having varying degrees of substitution. The results for the sulfated cyclodextrins also highlighted the importance of knowing the degree of substitution as well as the location of the substituents when comparing chiral selectors.

Chromatography, Micellar Electrokinetic Capillary↗

Chiral separations.

Explore the source record for details and available documents.

Chromatography, Liquid↗

Preparation and characterization of a suite of ephedra-containing standard reference materials.

The National Institute of Standards and Technology, the U.S. Food and Drug Administration, Center for Drug Evaluation and Research and Center for Food Safety and Applied Nutrition, and the National Institutes of Health, Office of Dietary Supplements, are collaborating to produce a series of Standard Reference Materials (SRMs) for dietary supplements. A suite of ephedra materials is the first in the series, and this paper describes the acquisition, preparation, and value assignment of these materials: SRMs 3240 Ephedra sinica Stapf Aerial Parts, 3241 E. sinica Stapf Native Extract, 3242 E. sinica Stapf Commercial Extract, 3243 Ephedra-Containing Solid Oral Dosage Form, and 3244 Ephedra-Containing Protein Powder. Values are assigned for ephedrine alkaloids and toxic elements in all 5 materials. Values are assigned for other analytes (e.g., caffeine, nutrient elements, proximates, etc.) in some of the materials, as appropriate. Materials in this suite of SRMs are intended for use as primary control materials when values are assigned to in-house (secondary) control materials and for validation of analytical methods for the measurement of alkaloids, toxic elements, and, in the case of SRM 3244, nutrients in similar materials.

Alkaloids↗