Search PubMed⌕ Search

Biomedical subjects

Kaile Li

Publications and source records attributed to Kaile Li.

4 recordsLinked to original sources

A constrained tracking algorithm to optimize plug patterns in multiple isocenter gamma knife radiosurgery planning.

We developed a source blocking optimization algorithm for Gamma Knife radiosurgery, which is based on tracking individual source contributions to arbitrarily shaped target and critical structure volumes. A scalar objective function and a direct search algorithm were used to produce near real-time calculation results. The algorithm allows the user to set and vary the total number of plugs for each shot to limit the total beam-on time. We implemented and tested the algorithm for several multiple-isocenter Gamma Knife cases. It was found that the use of limited number of plugs significantly lowered the integral dose to the critical structures such as an optical chiasm in pituitary adenoma cases. The main effect of the source blocking is the faster dose falloff in the junction area between the target and the critical structure. In summary, we demonstrated a useful source-plugging algorithm for improving complex multi-isocenter Gamma Knife treatment planning cases.

Algorithms↗

Selective source blocking for Gamma Knife radiosurgery of trigeminal neuralgia based on analytical dose modelling.

We have developed an automatic critical region shielding (ACRS) algorithm for Gamma Knife radiosurgery of trigeminal neuralgia. The algorithm selectively blocks 201 Gamma Knife sources to minimize the dose to the brainstem while irradiating the root entry area of the trigeminal nerve with 70-90 Gy. An independent dose model was developed to implement the algorithm. The accuracy of the dose model was tested and validated via comparison with the Leksell GammaPlan (LGP) calculations. Agreements of 3% or 3 mm in isodose distributions were found for both single-shot and multiple-shot treatment plans. After the optimized blocking patterns are obtained via the independent dose model, they are imported into the LGP for final dose calculations and treatment planning analyses. We found that the use of a moderate number of source plugs (30-50 plugs) significantly lowered (approximately 40%) the dose to the brainstem for trigeminal neuralgia treatments. Considering the small effort involved in using these plugs, we recommend source blocking for all trigeminal neuralgia treatments with Gamma Knife radiosurgery.

Algorithms↗

Improving a scissor-action couch for conformal arc radiotherapy and radiosurgery.

We have developed a method to improve the setup accuracy of a Varian Clinac 6/100 couch for delivering conformal arc therapy using a tertiary micro multileaf collimator (MLC) system. Several immobilization devices have been developed to improve the mechanical stability and isocenter alignment of the couch: turn-knob harnesses, double-track alignment plates, and a drop-in rod that attaches the couch to the concrete floor. These add-on components minimize the intercomponent motion of the couch's scissor elevator, which allows consistent treatment setup. The accuracy of our isocenter couch alignment is an improvement over the above devices, within 1 mm of their accuracy. The couch has been used with over 15 patients and with over 50 modulated conformal arc treatment deliveries at our institution.

Artifacts↗

Simultaneous minimizing monitor units and number of segments without leaf end abutment for segmental intensity modulated radiation therapy delivery.

Leaf end abutment is seldom studied when delivering segmental intensity modulated radiation therapy (IMRT) fields. We developed an efficient leaf sequencing method to eliminate leaf end abutment for segmental IMRT delivery. Our method uses simple matrix and sorting operations to obtain a solution that simultaneously minimizes total monitor units and number of segments without leaf end abutment between segments. We implemented and demonstrated our method for multiple clinical cases. We compared the results of our method with the results from exhaustive search method. We found that our solution without leaf end abutment produced equivalent results to the unconstrained solutions in terms of minimum total monitor units and minimum number of leaf segments. We conclude that the leaf end abutment fields can be avoided without affecting the efficiency of segmental IMRT delivery. The major strength of our method is its simplicity and high computing speed. This potentially provides a useful means for generating segmental IMRT fields that require high spatial resolution or complex intensity distributions.

Algorithms↗