Search PubMed⌕ Search

Biomedical subjects

Kai Uwe Juergens

Publications and source records attributed to Kai Uwe Juergens.

14 recordsLinked to original sources

Unexpected finding of elevated glucose uptake in fibrous dysplasia mimicking malignancy: contradicting metabolism and morphology in combined PET/CT.

Fibrous dysplasia is a common benign disorder of bone in which fibro-osseous tissue replaces bone spongiosa. Lesions have a typical appearance on computed tomography (CT) images and regularly show a markedly increased uptake in bone scintigraphy using (99m)Tc-labelled methylene diphosphonate ((99m)Tc-MDP) as radiotracer. The glucose avidity of these lesions depicted by positron emission tomography (PET) using the radiolabelled glucose derivative (18)F-fluoro-2-deoxy-glucose (FDG) is less well known since FDG-PET does not have a role in the assessment of this disease. However, single cases have been reported in which fibrous dysplasia was present in patients undergoing FDG-PET scanning for oncological reasons, and no significant FDG uptake was observed for lesions identified as fibrous dysplasia. We report on a 24-year-old man with known fibrous dysplasia who underwent combined FDG-PET/CT scanning because of suspected recurrence of testicular cancer. In contrast to prior reports, a markedly elevated uptake of FDG was seen in numerous locations that were identified as fibrous dysplasia by CT. Based on this result, we conclude that fibrous dysplasia may mimick malignancy in FDG-PET and that coregistered CT may help to resolve these equivocal findings.

Adult↗

Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging.

This study compares quantitative and qualitative information on global and regional left ventricular (LV) function obtained with multidetector-row computed tomography (MDCT) with that obtained with magnetic resonance imaging (MRI) in patients with a high prevalence of LV wall motion abnormalities. Thirty patients (19 male, 63.7+/-15.1 years) with myocardial infarction (n=12), coronary artery disease (n=9), arrhythmogenic right ventricular cardiomyopathy (n=6), and dilation cardiomyopathy (n=3) were included. Segmental LV wall motion (LV-WM) was assessed using a 4-point scale. Wall thickness measurements were calculated in diastolic and systolic short axis images. Two hundred and fifty-two out of 266 (94.7%) normal and 189 out of 214 (88.3%) segments with decreased wall motion were correctly identified by MDCT, yielding a sensitivity of 88% and specificity of 95% for identification of wall motion abnormalities. LV-WM scores were identical in 86.7% of 480 segments (kappa=0.809). MDCT had a tendency to underestimate the degree of wall motion impairment. Interobserver agreement was lower in MDCT (66.5%) than in MRI (89.1%; p<0.01). Normokinetic segments are reliably identified with MDCT. Sensitivity for detection and accurate classification of LV wall motion abnormalities need to be improved. Better temporal resolution of the CT system seems to be the most important factor for enhancing MDCT performance.

Adrenergic beta-Antagonists↗

Idiopathic left ventricular aneurysm and sudden cardiac death in young adults.

AIMS: We report three young patients presenting with life-threatening ventricular tachycardia (VT) or ventricular fibrillation (VF) and/or survived sudden cardiac arrest, who were admitted to our institution for further diagnostic evaluation. METHODS AND RESULTS: In all patients, idiopathic left ventricular (LV) aneurysms were identified after a detailed non-invasive and invasive evaluation. Sustained VT/VF was inducible during programmed ventricular stimulation in two of the three patients. Left ventricular aneurysms were depicted and characterized by various imaging modalities (echocardiography, magnetic resonance imaging, LV angiography). To elucidate the pathogenesis further, both myocardial viability and regional sympathetic innervation were assessed by radionuclide imaging techniques. Defects of innervation and metabolism were documented in the area of the aneurysm but distal to the aneurysm there were no signs of downstream denervation. CONCLUSION: Life-threatening arrhythmias may be the first manifestation of an idiopathic LV aneurysm, which can be reliably diagnosed with modern imaging techniques. Radionuclide imaging may yield additional information as to the involvement of the autonomic nervous system potentially associated with arrhythmogenesis. Management strategies in patients with an idiopathic LV aneurysm range from antiarrhythmic drug treatment, implantation of an automatic cardioverter-defibrillator to surgical aneurysmectomy.

Adult↗

Whole-body PET/CT with 11C-meta-hydroxyephedrine in tumors of the sympathetic nervous system: feasibility study and comparison with 123I-MIBG SPECT/CT.

UNLABELLED: The 11C-labeled tracer meta-hydroxyephedrine (11C-HED) is a noradrenaline analog that was developed to visualize the sympathetic nervous system with PET. Initial clinical studies show a rapid uptake of 11C-HED in localized tumors of this system. Whole-body imaging with 11C-HED PET is now possible as PET/CT scanners allow a rather short examination time. The aim of this study was to evaluate the feasibility of whole-body 11C-HED PET/CT for examination of tumors of the sympathetic nervous system and to directly compare the results with 123I-labeled meta-iodobenzylguanidine (123I-MIBG) scintigraphy, including SPECT/CT. METHODS: In 19 consecutive patients, 9 mo to 68 y old (median, 32 y), 24 whole-body 11C-HED PET/CT (low-dose CT) examinations were performed. Scans were compared with attenuation-corrected 123I-MIBG SPECT/CT scans (24-h scan, low-dose CT). The intensity of tracer accumulation above background was visually analyzed in both scans, PET and SPECT, using a 4-value scale. In 11C-HED PET, mean and maximum standardized uptake values were determined for all lesions. RESULTS: In 14 patients with 19 pairs of examinations, the following tumors were confirmed histologically: 6 neuroblastomas, 5 pheochromocytomas, 1 ganglioneuroblastoma, and 2 paragangliomas. In 5 patients, each having 1 pair of examinations, clinical follow-up and/or histologic examination did not reveal any tumor deriving from the sympathetic nervous system. 11C-HED PET/CT detected 80 of 81 totally depicted tumor lesions (sensitivity, 0.99; soft tissue, 61; bone, 19). 123I-MIBG SPECT/CT detected 75 of 81 lesions (sensitivity, 0.93; soft tissue, 56; bone, 19). With both methods, there were no false-positive lesions. The tumor-to-background contrast of 11C-HED uptake was higher in comparison with 123I-MIBG uptake in 26 lesions (0.32; soft tissue, 18; bone, 8), equal in 39 lesions (0.48; soft tissue, 30; bone, 9), and lower than 123I-MIBG uptake in 16 lesions (0.20; soft tissue, 14; bone, 2). CONCLUSION: Whole-body imaging using 11C-HED PET/CT is feasible in the clinical setting of patients with tumors of the sympathetic nervous system. 11C-HED PET/CT detected more tumor lesions than 123I-MIBG SPECT/CT. However, tumor-to-background contrast of 11C-HED in lesions can be higher, equal, or lower compared with 123I-MIBG.

3-Iodobenzylguanidine↗

Left ventricular function studied with MDCT.

Accurate determination of left ventricular (LV) myocardial function is fundamental for clinical diagnosis, risk stratification, and estimation of prognosis in patients with ischemic and nonischemic cardiomyopathy. Primarily, multi-detector-row spiral CT (MDCT) of the heart aimed at detecting coronary artery obstruction and cardiac morphology. Multiple studies have demonstrated that retrospectively, ECG-gated MDCT determination of LV volumes and consequently global LV function parameters is feasible in good agreement with established imaging modalities such as cineventriculography, echocardiography, and cine magnetic resonance imaging (CMR). Post-processing tools allow fast and semi-automatic determination of LV function parameters from MDCT data in analogy to known CMR evaluation approaches. Although MDCT is not considered to be first-line modality for LV function assessment, this technique provides accessory dynamic information in patients undergoing MDCT coronary angiography, contributing to combined assessment of cardiac morphology and function without need of additional radiation exposure. MDCT regional LV wall motion analysis at rest is feasible, but further improvement in temporal resolution seems mandatory to match results obtained from competing modalities. This paper will discuss the diagnostic potential of MDCT for assessment of LV function with regards to accuracy and clinical applications, as well as limitations, particularly in comparison with CMR as modality of reference.

Cardiac Volume↗

Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192+/-24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139+/-12, 113+/-13 and 96+/-11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9+/-11.8 ml to 8.1+/-13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function.

Adult↗

Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.

Aged↗

Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging.

RATIONALE AND OBJECTIVES: Electrocardiogram-gated 3D volume data from multidetector computed tomography coronary angiography (MDCT-CA) enable image reconstruction in any phase of the cardiac cycle. The objective was to determine left ventricular (LV) function parameters by MDCT in comparison to cine magnetic resonance imaging (MRI). METHOD: Thirty patients with known or suspected coronary artery disease (CAD) underwent MDCT-CA. From multiplanar reformations in short axis orientation end-diastolic and end-systolic LV volumes (LVEDV, LVESV) were determined to calculate LV stroke volume and ejection fraction (LVSV, LVEF) and compared with MRI measurements. RESULTS: LVEDV (147 +/- 27 mL) and LVESV (65 +/- 22 mL) determined by MDCT correlated well to the respective MRI measurements (LVEDV 133 +/- 27 mL, r = 0.80, P < 0.001; LVESV 48 +/- 19 mL, r = 0.89, P < 0.001). LVSV (MDCT 82 +/- 15 mL; MRI 85 +/- 17 mL; r = 0.77, P < 0.001) and LVEF (MDCT 56 +/- 9%; MRI 65 +/- 8%; r = 0.85, P < 0.001) showed a good correlation as well. LVEF was significantly underestimated by MDCT (-8.5 +/- 4.7%, P < 0.001). CONCLUSIONS: Initial experience in patients evaluated for CAD shows that spiral MDCT studies may provide LV functional data in good correlation to Cine MRI.

Adult↗

Perivascular inflammatory reaction to a Hemobahn stent-graft: diagnosis with 3D MR angiography.

PURPOSE: To present a rare perivascular inflammatory reaction to a commercially produced polytetrafluoroethylene-covered stent and demonstrate the utility of 3-dimensional (3D) magnetic resonance angiography (MRA) in the diagnosis of this phenomenon. CASE REPORT: Three weeks after percutaneous deployment of a Hemobahn stent-graft to treat a high-grade stenosis and aneurysm of the proximal left superficial femoral artery (SFA), a 70-year-old diabetic man developed fever, pain, and local swelling of the left thigh. Venous thrombosis was excluded by ultrasound imaging; a normal flow profile was seen in the left common and superficial femoral arteries. Blood analysis found elevated inflammatory markers. MRA revealed extensive soft-tissue edema and perivascular contrast enhancement around the left SFA, but the stent-graft was patent. The clinical symptoms resolved within 7 days after initiation of anti-inflammatory therapy. Follow-up MRA scans demonstrated significantly reduced inflammatory reaction over the next few months. CONCLUSIONS: Symptomatic perivascular inflammatory soft-tissue response to a stent-graft can be diagnosed with MR imaging studies.

Aged↗

Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease.

OBJECTIVE: Retrospectively ECG-gated three-dimensional volume data from multidetector CT (MDCT) coronary angiography enable image reconstruction of the cardiac cycle in the diastolic and systolic phases. The objective of our study was to investigate the feasibility of determining left ventricular function from MDCT coronary angiography data sets in 22 patients with coronary artery disease and to study the correlation of MDCT results with those of functional data from biplane cineventriculography. CONCLUSION: Multiplanar reformations from three-dimensional MDCT data allowed good delineation of endocardial and epicardial left ventricular contours. In patients evaluated for coronary artery disease, MDCT coronary angiography with retrospective ECG gating provides functional data in an acceptable correlation (r = 0.8; p < 0.05) to biplane cineventriculography.

Adult↗

Coronary artery aneurysm and type-A aortic dissection demonstrated by retrospectively ECG-gated multislice spiral CT.

The case of a 40-year-old male patient with a coronary aneurysm of the proximal left descending artery (LAD) combined with circumferential type-A dissection of the ascending aorta is reported. Computed tomography angiography of the coronary arteries was performed using multislice spiral computed tomography (MSCT) with retrospective ECG gating. Anatomical relations of the LAD aneurysm as well as the origin of the left coronary artery from the false lumen of the dissection were well depicted for planning of the surgical intervention using this new noninvasive imaging modality.

Adult↗

Cine and tagged magnetic resonance imaging in short-term stunned versus necrotic myocardium.

We investigated the potential of Cine and 2D Tagged Cardiac Magnetic Resonance (CMR) Imaging to distinguish stunned from necrotic left ventricular (LV) myocardium in the early postischemic phase in an open-chest animal model (N = 12). Reversible and permanent occlusion of the LAD coronary artery resulted in global LV dysfunction in both groups without significant differences. LAD perfused segments revealed significant higher values for end systolic wall thickening (ESWT) and percentual systolic wall thickening in animals with stunned myocardium. Analysis of strain parameters showed significant regional differences (maximal principal strain lambda1, deviation angle beta) between postischemic and remote myocardium within both groups, however results were not significantly different comparing animals with stunned myocardium to animals with myocardial necrosis. In conclusion, at rest neither global LV functional nor regional strain parameters derived from Cine and 2D Tagged CMR Imaging can distinguish animals with short-term stunned myocardium from respective animals with necrotic myocardium. Diagnostic value of ESWT is limited due to the spatial resolution of the gradient-echo sequence used.

Animals↗