Search PubMed⌕ Search

Biomedical subjects

Kagan Kerman

Publications and source records attributed to Kagan Kerman.

At least 19 recordsLinked to original sources

Label-free protein biosensor based on aptamer-modified carbon nanotube field-effect transistors.

We have fabricated label-free protein biosensors based on aptamer-modified carbon nanotube field-effect transistors (CNT-FETs) for the detection of immunoglobulin E (IgE). After the covalent immobilization of 5'-amino-modified 45-mer aptamers on the CNT channels, the electrical properties of the CNT-FETs were monitored in real time. The introduction of target IgE at various concentrations caused a sharp decrease in the source-drain current, and a gradual saturation was observed at lower concentrations. The amount of the net source-drain current before and after IgE introduction on the aptamer-modified CNT-FETs increased as a function of IgE concentration. The detection limit for IgE was determined as 250 pM. We have also prepared CNT-FET biosensors using a monoclonal antibody against IgE (IgE-mAb). The electrical properties of the aptamer- and antibody-modified CNT-FETs were compared. The performance of aptamer-modified CNT-FETs provided better results than the ones obtained using IgE-mAb-modified CNT-FETs under similar conditions. Thus, we suggest that the aptamer-modified CNT-FETs are promising candidates for the development of label-free protein biosensors.

Aptamers, Nucleotide↗

Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes.

We have fabricated a label-free electrochemical immunosensor using microelectrode arrays modified with single-walled carbon nanotubes (SWNTs). Label-free detection of a cancer marker, total prostate-specific antigen (T-PSA), was carried out using differential pulse voltammetry (DPV). The current signals, derived from the oxidation of tyrosine (Tyr), and tryptophan (Trp) residues, increased with the interaction between T-PSA on T-PSA-mAb covalently immobilized on SWNTs. The selectivity of our biosensor was challenged using bovine serum albumin (BSA) as the target protein. The detection limit for T-PSA was determined as 0.25 ng/mL. Since the cut-off limit of T-PSA between prostate hyperplasia and cancer is 4 ng/mL, the performance of our label-free electrochemical immunosensor seems promising for further clinical applications.

Biosensing Techniques↗

Multiple label-free detection of antigen-antibody reaction using localized surface plasmon resonance-based core-shell structured nanoparticle layer nanochip.

In this research, a localized surface plasmon resonance (LSPR)-based bioanalysis method for developing multiarray optical nanochip suitable for screening bimolecular interactions is described. LSPR-based label-free monitoring enables to solve the problems of conventional methods that require large sample volumes and time-consuming labeling procedures. We developed a multiarray LSPR-based nanochip for the label-free detection of proteins. The multiarray format was constructed by a core-shell-structured nanoparticle layer, which provided 300 nanospots on the sensing surface. Antibodies were immobilized onto the nanospots using their interaction with Protein A. The concentrations of antigens were determined from the peak absorption intensity of the LSPR spectra. We demonstrated the capability of the array measurement using immunoglobulins (IgA, IgD, IgG, IgM), C-reactive protein, and fibrinogen. The detection limit of our label-free method was 100 pg/mL. Our nanochip is readily transferable to monitor the interactions of other biomolecules, such as whole cells or receptors, with a massively parallel detection capability in a highly miniaturized package. We anticipate that the direct label-free optical immunoassay of proteins reported here will revolutionize clinical diagnosis and accelerate the development of hand-held and user-friendly point-of-care devices.

Antigen-Antibody Reactions↗

Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications.

Polymerase chain reaction (PCR) is an essential part of research based on genomics or cell analysis. The development of a microfluidic device that would be suitable for high-temperature-based reactions therefore becomes an important contribution towards the integration of micro-total analysis systems (muTAS). However, problems associated with the generation of air bubbles in the microchannels before the introduction of the assay liquid, which we call the "initial start-up" in this study, made the flow irregular and unstable. In this report, we have tried to address these problems by adapting a novel liquid-flow method for high-temperature-based reactions. A PDMS-based microfluidic device was fabricated by soft-lithography techniques and placed on a cartridge heater. The generation of the air bubbles was prevented by introducing the fluorinated oil, an inert and highly viscous liquid, as the cap just before the introduction of the sample solutions into the microchannels. The technique was applied for continuous-flow PCR, which could perform PCR on-chip in a microfluidic system. For the evaluation of practical accuracy, plasmid DNA that serves as a reference molecule for the quantification of genetically modified (GM) maize was used as the template DNA for continuous-flow PCR. After PCR, the products were collected in a vial and analyzed by gel electrophoresis to confirm the accuracy of the results. Additionally, quantitative continuous-flow PCR was performed using TaqMan technology on our PCR device. A laser detection system was also used for the quantitative PCR method. We observed a linear relationship between the threshold cycle (Ct) and the initial DNA concentration. These results showed that it would be possible to quantify the initial copies of the template DNA on our microfluidic device. Accurate quantitative DNA analysis in microfluidic systems is required for the integration of PCR with muTAS, thus we anticipate that our device would have promising potential for applications in a wide range of research.

DNA↗

Label-free electrochemical immunoassay for the detection of human chorionic gonadotropin hormone.

Here we report on a new and rapid immunoassay for the label-free voltammetric detection of human chorionic gonadotropin hormone (hCG) in urine. Monitoring the changes in the current signals of antibodies (Abs) before and after the binding of the antigen (Ag) provides the basis for an immunoassay that is simple, rapid, and cost-effective. Since hCG is found at highly elevated levels in pregnant female urine with the range of 30,000-200,000 mIU/mL (approximately 30-200 nM) by 8-10 weeks into pregnancy, its label-free electrochemical detection was achieved by using our method. The coverage of the electrode surface with the Ab and the incubation time with the target Ag were optimized for the detection of hCG. The limit of detection of our method was calculated to be 15 pM (n = 3, approximately 15 mIU/mL) in synthetic hCG samples and 20 pM (n = 3, approximately 20 mIU/mL) in human urine. The electrochemical results for the detection of hCG in the urine samples were in agreement with the results obtained using a reference system, enzyme-linked immunosorbent assay. Further research about the intrinsic electroactivity of Abs and their target molecules would surely provide new and sensitive screening assays, as well as extensive data regarding their interaction mechanisms.

Antibodies, Monoclonal↗

A novel enhancement assay for immunochromatographic test strips using gold nanoparticles.

The immunochromatographic assay is a well-known and convenient diagnostic system. In this report, the development of a novel enhancement assay for the test strips is described. Additionally, this highly sensitive immunochromatographic assay was applied to detect human chorionic gonadotropin hormone (HCG) as the model case. The primary antibody-conjugated gold nanoparticles were used as the enhancer of the standard method. The primary antibodies were immobilized within a defined detection zone (test line) on the diagnostic nitrocellulose membrane. The secondary antibodies were conjugated with colloidal gold nanoparticles. In combination with an effective sample pretreatment, the gold-conjugated antibodies and the primary antibodies formed a sandwich complex with the target protein. Within the test line, the sandwich complex was immobilized, and furthermore, concentrated by the enhancer resulting in a localized surface plasmon resonance (LSPR) phenomenon and a distinct red color on the test line. The intensity of color of the red test line (signal intensity), which correlated directly with the concentration of the target protein in the standard or spiked samples, was assessed visually and by computer image analysis using a three-determination analysis. Under optimum conditions, the limit of detection (LOD) for HCG assay was 1 pg/mL. When using human serum, 10 pg/mL of HCG could be detected. We have also spiked total prostate-specific antigen (TPSA) in female serum. The LOD for TPSA was determined as 0.2 ng/mL. With this method, the quantitative determination of the target protein could be completed in less than 15 min. Our novel immunochromatographic strips using the enhancing method based on LSPR of gold nanoparticles are useful as a rapid and simple screening method for the detection of important analytes for medical applications, environmental monitoring, food control, and biosecurity.

Chorionic Gonadotropin↗

Electrochemical genosensor based on peptide nucleic acid-mediated PCR and asymmetric PCR techniques: Electrostatic interactions with a metal cation.

The unique structure of peptide nucleic acids (PNAs), linking the N-(2-aminoethyl)glycine units that create a neutral backbone, and prevent it from acting as a primer for DNA polymerase, has been utilized in an electrochemical biosensor scheme for simple and sensitive detection of hybridization. When the PNA is targeted against a single-nucleotide polymorphism (SNP) or wild-type site on the gene, PNA-mediated polymerase chain reaction (PCR) clamping method effectively blocks the formation of a PCR product. In our report, PNA probe for PCR clamping was targeted against the wild-type site of alcohol dehydrogenase. The electrostatic interactions between the negatively charged DNA and neutral PNA molecules with redox-active metal cation cobalt(III)hexamine ([Co(NH3)6]3+) were monitored using differential pulse voltammetry. The electrostatic binding of [Co(NH3)6]3+ to DNA provided the basis for the discrimination against PNA/PNA, PNA/DNA, and DNA/DNA hybrid molecules. We have optimized the experimental conditions, such as probe concentration, [Co(NH3)6]3+ concentration, accumulation time for [Co(NH3)6]3+, and target concentration. A new pretreatment method has also been employed to allow fast and simple detection of hybridization reaction between the PCR amplicon and the probe on glassy carbon electrode (GCE) surface. This method was based on the application of a high-temperature treatment (95 degrees C, 5 min), followed by a 1-min incubation in the presence of DNA primers. The excess concentration of DNA primers prevented the rehybridization of the denatured strands, while enabling the target gene sequence to bind with the immobilized probe. Additionally, asymmetric PCR was employed to detect the presence of genetically modified organism in standard Roundup Ready soybean samples. The amplicons of asymmetric PCR, which were predominantly single-stranded DNA as a result of unequal primer concentration, hybridized with the DNA probe on the sensor surface efficiently. The attachment of long single-strands on GCE surface caused the accumulation of [Co(NH3)6]3+ and a high current response. Here, we report a versatile method that would allow for simple and rapid analysis of nucleic acids in combination with PNA-mediated PCR and asymmetric PCR techniques by using an electrochemical genosensor.

Base Sequence↗

Resin-based micropipette tip for immunochromatographic assays in urine samples.

A novel bioanalysis system based on immunochromatography was developed in connection with a nitrocellulose resin modified micropipette tip, such as ZipTip. The sandwich-type immunoassay was applied to our bioanalysis system. The simple handling of the micropipette enabled us to increase the sample volume and detect low concentrations of target antigens in urine samples. In addition, the washing procedure could also be performed easily to reduce the background signal levels. For analytical evaluations, the color intensity was captured by a flatbed scanner, and processed by a software. We have achieved the detection of human chorionic gonadotropin (hCG) and prostate-specific antigen (PSA). The detection limit of hCG was 0.5 ng/ml (0.05 ng/tip), which is comparable to that of other conventional immunochromatographic systems. Moreover, the detection of PSA was greatly improved over the existing systems with the application of different sample volumes, such as 1 ng/ml (0.2 ng/tip) in a 200 microl sample volume, and 1 ng/ml (0.3 ng/tip) in 300 microl sample volume. Our bioanalysis system is a promising candidate for application to point-of-care tests with its simple handling and high sensitivity.

Antibodies, Monoclonal↗

Estimation of maturity of compost from food wastes and agro-residues by multiple regression analysis.

The composting process of food wastes and tree cuttings was examined on four composting types composed from two kinds of systems and added mixture of microorganisms. The time courses of 32 parameters in each composting type were observed. The efficient composting system was found to be the static aerated reactor system in comparison with the turning pile one. Using the multiple regression analysis of all the data (159 samples) obtained from this study, some parameters were selected to predict the germination index (GI) value, which was adopted as a marker of compost maturity. For example, using the regression model generated from pH, NH(4)(+) concentration, acid phosphatase activity, and esterase activity of water extracts of the compost, GI value was expressed by the multi-linear regression equation (p<0.0001). High correlations between the measured GI value and the predicted one were made in each type of compost. As a result of these observations, the compost maturity might be predicted by only sensing of the water extract at the composting site without any requirements for a large-size equipment and skill, and this prediction system could contribute to the production of a stable compost in wide-spread use for the recycling market.

Acid Phosphatase↗

Label-free detection of peptide nucleic acid-DNA hybridization using localized surface plasmon resonance based optical biosensor.

The development of label-free optical biosensors for DNA and other biomolecules has the potential to impact life sciences as well as screening in medical and environmental applications. In this report, we developed a localized surface plasmon resonance (LSPR) based label-free optical biosensor based on a gold-capped nanoparticle layer substrate immobilized with peptide nucleic acids (PNAs). PNA probe was designed to recognize the target DNA related to tumor necrosis factor. The nanoparticle layer was formed on a gold-deposited glass substrate by the surface modified silica nanoparticles using silane-coupling reagent. The optical properties of gold-capped nanoparticle layer substrate were characterized through monitoring the changes in the absorbance strength, as the thickness of the biomolecular layer increased with hybridization. The detection of PNA-DNA hybridization with target oligonucleotides and PCR-amplified real samples were performed with a limit of detection value of 0.677 pM target DNA. Selective discrimination against a single-base mismatch was also achieved. Our LSPR-based biosensor with the gold-capped nanoparticle layer substrate is applicable to the design of biosensors for monitoring of the interaction of other biomolecules, such as proteins, whole cells, or receptors with a massively parallel detection capability in a highly miniaturized package.

Biosensing Techniques↗

A rapid label-free electrochemical detection and kinetic study of Alzheimer's amyloid beta aggregation.

We present the first electrochemical detection, characterization, and kinetic study of the aggregation of Alzheimer's disease (AD) amyloid beta peptides (Abeta-40, Abeta-42) using three different voltammetric techniques at a glassy carbon electrode (GCE). This method is based on detecting changes in the oxidation signal of tyrosine (Tyr) residue. As the peptides aggregate, there are structure conformational changes, which affect the degree of exposure of Tyr to the molecular surface of the peptides. The results show significant differences in the aggregation process between the two peptides, and these correlate highly with established techniques. The method is rapid and label-free, and the principle can be universally applied to other protein aggregation studies related to diseases, such as Huntington's, Parkinson's, and Creutzfeldt Jacob (CJD). This method could also be explored in screening for the effectiveness of AD therapies.

Alzheimer Disease↗

Escherichia coli single-strand binding protein-DNA interactions on carbon nanotube-modified electrodes from a label-free electrochemical hybridization sensor.

An electrochemical hybridization biosensor based on the intrinsic oxidation signals of nucleic acids and proteins has been designed, that makes use of the unique binding event between Escherichia coli single-strand binding protein (SSB) and single-stranded DNA (ssDNA). The voltammetric signal from guanine oxidation significantly decreased upon binding of SSB to single-stranded oligonucleotides (probe), anchored on a single-walled carbon nanotube (SWCNT) -modified screen-printed carbon electrode (SPE). Simultaneously, oxidation of the tyrosine (Tyr) and tryptophan (Trp) residues of the SSB protein increased upon binding of the SSB protein to ssDNA and ss-oligonucleotides. After the hybridization, SSB did not bind to the double helix form, and the guanine signal could be observed along with the disappearance of the oxidation signal of the protein. The amplification of intrinsic guanine and protein oxidation signals by SWCNT, and a washing step with sodium dodecylsulfate, enabled the specific detection of a point mutation. Monitoring the changes in the guanine and protein signals upon hybridization greatly simplified the detection procedure. The detection limit of 0.15 microg/ml target DNA can be applied to genetic assays. To the best of our knowledge, this is the first work that utilizes the monitoring of SSB-DNA interactions on a solid transducer for the electrochemical detection of DNA hybridization by using intrinsic oxidation signals.

Base Sequence↗

Microchamber array based DNA quantification and specific sequence detection from a single copy via PCR in nanoliter volumes.

A novel method for DNA quantification and specific sequence detection in a highly integrated silicon microchamber array is described. Polymerase chain reaction (PCR) mixture of only 40 nL volume could be introduced precisely into each chamber of the mineral oil layer coated microarray by using a nanoliter dispensing system. The elimination of carry-over and cross-contamination between microchambers, and multiple DNA amplification and detection by TaqMan chemistry were demonstrated, for the first time, by using our system. Five different gene targets, related to Escherichia coli were amplified and detected simultaneously on the same chip by using DNA from three different serotypes as the templates. The conventional method of DNA quantification, which depends on the real-time monitoring of variations in fluorescence intensity, was not applied to our system, instead a simple method was established. Counting the number of the microchambers with a high fluorescence signal as a consequence of TaqMan PCR provided the precise quantification of trace amounts of DNA. The initial DNA concentration for Rhesus D (RhD) gene in each microchamber was ranged from 0.4 to 12 copies, and quantification was achieved by observing the changes in the released fluorescence signals of the microchambers on the chip. DNA target could be detected as small as 0.4 copies. The amplified DNA was detected with a CCD camera built-in to a fluorescence microscope, and also evaluated by a DNA microarray scanner with associated software. This simple method of counting the high fluorescence signal released in microchambers as a consequence of TaqMan PCR was further integrated with a portable miniaturized thermal cycler unit. Such a small device is surely a strong candidate for low-cost DNA amplification, and detected as little as 0.4 copies of target DNA.

Biosensing Techniques↗

Allele-specific genotyping by using guanine and gold electrochemical oxidation signals.

Electrochemical DNA biosensors have become strong candidates for DNA based analysis. Allele-specific genotyping is also one of the important research areas, where electrochemical approaches provide promising advances. Recently reported two methods based on electrochemical guanine and colloidal gold (Au) nanoparticle oxidation signals are reviewed and compared with the existing genotyping methods in this report.

Alleles↗

On-chip nanoliter-volume multiplex TaqMan polymerase chain reaction from a single copy based on counting fluorescence released microchambers.

A novel method for multiplex TaqMan PCR in nanoliter volumes on a highly integrated silicon microchamber array is described. Three different gene targets, related to beta-actin, sex-determining region Y (SRY), and Rhesus D (RhD) were amplified and detected simultaneously on the same chip by using three different types of human genomic DNA as the templates. The lack of cross-contamination and carryover was shown using alternate dispensing of mineral oil-coated microchambers containing template and those without template. To confirm the specificity of our system to beta-actin, SRY, and RhD genes, we employed the larger volume PCR samples to a commercial real-time PCR system, SmartCycler. The samples were cycled with the same sustaining temperatures as with the microchamber array. Instead of the conventional method of DNA quantification, counting the number of the fluorescence released microchambers in consequence to TaqMan PCR was employed to our chip. This simple method of observing the end point signal had provided a dynamic quantitative range. Stochastic amplification of 0.4 copies/reaction chamber was achieved. The microfabricated PCR chip demonstrated a rapid and highly sensitive response for simultaneous multiple-target detection, which is a promising step toward the development of a fully integrated device for the "lab-on-a-chip" DNA analysis.

Actins↗

Electrochemical coding of single-nucleotide polymorphisms by monobase-modified gold nanoparticles.

Rapidly increasing information about the human genome requires a fast and simple method for the detection of single-nucleotide polymorphisms (SNPs). To date, the conventional SNP detection technologies have been unable to identify all possible SNPs and needed further development in cost, speed, and sensitivity. Here we describe a novel method to discriminate and code all possible combinations. SNPs were coded by monitoring the changes in the electrochemical signal of the monobase-modified colloidal gold (Au) nanoparticles. First, a chitosan layer was formed on the alkanethiol self-assembled monolayer-modified Au nanoparticle. The monobases were then attached onto the chitosan-coated Au nanoparticles through their 5' phosphate group via the formation of a phosphoramidate bond with the free amino groups of chitosan. The size of the surface-modified Au nanoparticle was found to be 8.46 +/- 1.53 nm by using atomic force microscopy. If there is a SNP in DNA and the mismatched bases are complementary to the monobase, Au nanoparticles accumulate on the electrode surface in the presence of DNA polymerase I (Klenow fragment), thus resulting in a significant change in the Au oxide wave. In this report, monobase-modified Au nanoparticles show not only the presence of a SNP, but also identify which bases are involved within the pair. Especially, the identification of a transversion SNP, which contains a couple of the same pyrimidine or purine bases, is greatly simplified. A model study was performed by using a synthetic 21-base DNA probe related to tumor necrosis factor (TNF-alpha) along with its all possible mutant combinations. This versatile nanoparticle-based electrochemical protocol is a promising candidate for coding all mutational changes.

Base Sequence↗

Electrochemical genosensor based on colloidal gold nanoparticles for the detection of Factor V Leiden mutation using disposable pencil graphite electrodes.

Electrochemical genosensors for the detection of the Factor V Leiden mutation from polymerase chain reaction (PCR) amplicons using the oxidation signal of colloidal gold (Au) is described. A pencil graphite electrode (PGE) modified with target DNA, when hybridized with complementary probes conjugated to Au nanoparticles, responded with the appearance of a Au oxide wave at approximately +1.20 V. Specific probes were immobilized onto the Au nanoparticles in two different modes: (a) Inosine-substituted probes were covalently attached from their amino groups at the 5' end using N-(3-dimethylamino)propyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysulfosuccinimide (NHS) as a coupling agent onto a carboxylate-terminated l-cysteine self-assembled monolayer (SAM) preformed on the Au nanoparticles, and (b) probes with a hexanethiol group at their 5' phosphate end formed a SAM on Au nanoparticles. The genosensor relies on the hybridization of the probes with their complementary targets, which are covalently immobilized at the PGE surface. Au-tagged 23-mer capture probes were challenged with the synthetic 23-mer target, 131-base single-stranded DNA or denatured 256-base polymerase chain reaction (PCR) amplicon. The appearance of the Au oxidation signal shortened the assay time and simplified the detection of the Factor V Leiden mutation from PCR amplified real samples. The discrimination between the homozygous and heterozygous mutations was also established by comparing the peak currents of the Au signals. Numerous factors affecting the hybridization and nonspecific binding events were optimized. The detection limit for the PCR amplicons was found to be as low as 0.78 fmol; thus, it is suitable for point-of-care applications.

DNA↗

Detection of achondroplasia G380R mutation from PCR amplicons by using inosine modified carbon electrodes based on electrochemical DNA chip technology.

The detection of Achondroplasia G380R mutation from real samples was performed by monitoring the oxidation signal of guanine. Inosine-substituted 12-mer capture probes related to the homozygous or heterozygous alleles of Achondroplasia G380R mutation were adsorbed onto carbon paste electrode (CPE) surface. No guanine signal was obtained from the capture probes, since the inosine bases were electroinactive. Then, these probes were hybridized with the denatured PCR samples on the CPE surface. The hybridization between the probe and target sequences was determined by using the oxidation signal of guanine in connection with differential pulse voltammetry (DPV). The oxidation signal of guanine was observed as a result of the specific hybridization between the probe and PCR sample. The changes in the peak height of the guanine signal provided the information whether the PCR sample contained heterozygous allele or homozygous allele. Numerous factors affecting the hybridization and nonspecific binding events were optimized to detect down to 41.24 fmol/ml target DNA. The electrochemical detection of Achondroplasia G380R mutation from PCR samples greatly shortened and simplified the diagnosis for the homozygous mutant type, which is lethal for the newborn.

Achondroplasia↗