Fatigue behavior of calcium phosphate coatings with different stability under dry and wet conditions.

To obtain stable plasma sprayed calcium phosphate coatings, coatings with a high crystallinity and low solubility were developed. However, stability of ceramic coatings is also influenced by their fatigue resistance. Recently, fatigue failure was proposed to explain coating detachment from implants under loaded conditions. Therefore, plasma-sprayed calcium phosphate coatings with different crystallinity were investigated in vitro for fatigue failure. An amorphous and a crystalline hydroxylapatite coating (AHA and CHA) and a highly crystalline fluorapatite coating (FA) were subjected to cyclic load tests, both in dry conditions and in simulated body fluid (SBF). The results in SBF revealed that the crystalline CHA and FA coating detached completely at the highest stressed middle section of the bar. The FA coating delaminated earlier than the CHA coating. The amorphous AHA coating showed only partial coating loss at the completion of the test. Tests in dry conditions did not reveal any change in the coatings tested. These results suggest a relation between crystallinity of apatite coatings and their failure due to fatigue: high crystallinity coatings demonstrate earlier and more complete fatigue failure than the amorphous apatite coatings. It can be concluded that coating stability is not determined solely by static dissolution, but by fatigue failure as well.

Biocompatible Materials↗

Incorporation of bovine serum albumin in calcium phosphate coating on titanium.

Calcium phosphate (Ca-P) and bovine serum albumin (BSA) were coprecipitated as a coating on commercially pure titanium (cpTi) with a high protein loading (15 wt %) by employing a recently developed wet-chemistry technique. It was observed that the incorporation of BSA significantly modified the morphology, composition, and crystallinity of the Ca-P coating. The Ca-P coating without BSA is a mixture of hydroxyapatite (HA) and octacalcium phosphate (OCP) with sharp-edged thin OCP crystal plates on the top layer, whereas only an HA phase was detected in the Ca-P/BSA coating. The crystal plates in the latter had a more rounded appearance. The Ca-P/BSA coatings were immersed respectively in neutral (pH 7.4) and acidic (starting pH 4.0) phosphate-buffered saline (PBS) at 37 degrees C over a 14-day period. No protein release was detected in the neutral PBS during the immersion; however, a continuous release of BSA was measured in the acidic PBS, subsequently leading to the formation of a very dense and well-adherent composite coating of BSA and Ca-P on cpTi. The present study provides the possibility to achieve a long-term effective release of biologically active proteins from a Ca-P-coated metallic implant.

Calcium Phosphates↗

A preliminary study on osteoinduction of two kinds of calcium phosphate ceramics.

With respect to the effect of material factors on calcium phosphate biomaterial-induced osteogenesis, the osteoinductive property of two kinds of porous hydroxyapatite ceramics, which were made by different producers, was investigated in dorsal muscles of dogs. One hydroxyapatite ceramic (S-HA), macroporous implants with rough pore walls containing abundant micropores, was made by Sichuan Union University (Chengdu, China); the other hydroxyapatite ceramic (J-HA), porous implants with smooth macropore walls composed of regularly aligned crystal grains, was provided by Mitsubishi Ceramic Int. (Japan). Different tissue response was detected histologically and microradiographically after the ceramic samples had been implanted in dorsal muscles of dogs for 3 and 6 months. Bone formation was found in S-HA at 3 months, which increased at 6 months. In contrast, no bone formation was detected in J-HA at both 3 and 6 months. These results indicate that with the special architecture, calcium phosphate ceramic can induce bone formation in soft tissue. As both materials were very similar in their chemical and crystallographic structures, but varied in their microstructures, the latter seem to be an important factor affecting the osteoinductive capacity of calcium phosphate ceramics. These data suggest that, by controlling the preparation of calcium phosphate ceramic, bone substitutes with intrinsic osteoinductive property can be developed from calcium phosphates.

Animals↗

Biomimetic calcium phosphate coatings on Ti6AI4V: a crystal growth study of octacalcium phosphate and inhibition by Mg2+ and HCO3-.

The biomimetic approach for coating metal implants allows the deposition of new calcium phosphate (Ca-P) phases. Films elaborated at physiological conditions might have structures closer to bone mineral than hydroxylapatite (HA) plasma-sprayed coatings. In this study, different Ca-P coatings have been deposited through a two-step procedure. After cleaning and etching, Ti6Al4V plates were pretreated by soaking in a simulated body fluid (SBF), i.e., a solution containing inorganic components in concentration more or less similar to body fluids: a thin amorphous carbonated Ca-P layer precipitated on the metal substrate. Second, by soaking these thinly coated metal substrates in another SBF, with different concentrations, the thin amorphous carbonated Ca-P layer led to the fast precipitation of a second and thick Ca-P layer. Different SBF solutions were used in order to investigate the influence of magnesium and carbonate ions. From SBF containing only Ca2+ and HPO4(2-) ions, an octacalcium phosphate layer grew epitaxially on the substrate. When Mg2+ was added into this SBF, the coating was composed of Ca-deficient apatite crystals, while the addition of HCO3- in SBF led to the formation of a B-carbonated apatite layer. Magnesium and carbonate acted as inhibitors of crystal growth. The three phases obtained by our biomimetic process are closer to bone mineral structure than plasma-sprayed HA. Therefore, the obtained results may be particularly relevant for the development of biomimetic Ca-P coatings with optimal bioactivity.

Alloys↗

Tissue response to nano-hydroxyapatite/collagen composite implants in marrow cavity.

The tissue response to a nano-hydroxyapatite/collagen composite implanted in a marrow cavity was investigated by histology and scanning electron microscopy. A Knoop microhardness test was performed to compare the mechanical behavior of the composite and bone. The ultrastructural features of the composite, especially the carbonate-substituted hydroxyapatite with low crystallinity and nanometer size, made it a bone-resembling material. It was bioactive, as well as biodegradable. At the interface of the implant and marrow tissue, solution-mediated dissolution and giant cell mediated resorption led to the degradation of the composite. Interfacial bone formation by osteoblasts was also evident. The process of implant degradation and bone substitution was reminiscent of bone remodeling. The composite can be incorporated into bone metabolism instead of being a permanent implant. For lack of the hierarchical organization similar to that of bone, the composite exhibited an isotropic mechanical behavior. However, the resistance of the composite to localized pressure could reach the lower limit of that of the femur compacta.

Animals↗

Collagen/apatite coating on 3-dimensional carbon/carbon composite.

A three-dimensional carbon/carbon composite (3D C/C) was studied as potential bone-repairing material; its major mechanical properties were found to be closer to those of human bone than other common bone-repairing materials available. In vitro calcification tests revealed that as-received 3D C/C is almost bioinert in simulated body fluid (SBF) over an immersion period of 4 weeks. To improve the bioactivity of 3D C/C, surface modification was accomplished through two practical routes: (1) grafting with polyethylene glycol (PEG) and (2) phosphorylation and precalcification. After grafting with alpha, omega di(aminopropyl) polyethylene glycol 800 (NH2-PEG-NH2), a continuous layer of calcium phosphate was formed on the surface of 3D C/C in SBF after 4 weeks. Phosphorylated 3D C/C samples have the ability to induce apatite precipitation after precalcification in a saturated Ca(OH)2 solution for 1 week. To speed up the coating process, a calcification solution with collagen was developed in which a collagen/apatite coating layer can be formed on 3D C/C in 9 h in ambient conditions.

Apatites↗

Healing of large (2 mm) gaps around calcium phosphate-coated bone implants: a study in goats with a follow-up of 6 months.

Plasma-sprayed hydroxylapatite (HA) coatings are known for their ability to demonstrate osseointegration with bone. Recently it was found that the amount of bone apposition was strongly reduced 6 weeks after implantation in a goat model if gaps of two millimeters between bone and apatite coating existed. Stability of the apatite coatings examined did not influence the gap-healing ability. This study investigated whether a longer follow-up period of 24 weeks would be sufficient for the restoration of bone apposition on apatite coatings in an identical surgical model with 2 mm gaps, and whether bone apposition on the apatite coatings is influenced by the coating stability. Three coatings were investigated: 25-30% crystalline HA (aHA), 60-63% crystalline HA (cHA), and 85-90% crystalline fluorapatite (FA). Uncoated Ti-6A1-4V implants were used as controls. Implants were inserted in the femoral condyles of both femora of eight goats. Each goat received four implants. Histology revealed that bone formation on each of the apatite coatings remained low and did not increase with an extended follow-up period of 24 weeks. The coatings showed significantly (P < 0.01) more bone contact than the uncoated control implants. The three different coatings did not show significant differences in bone apposition. The aHA coating in most cases had disappeared completely after 24 weeks. Despite the disappearance of the aHA coating, bone contact was seen on the substrate surface without fibrous tissue interposition. The cHA coating showed minor signs of degradation while the FA coatings showed no visible degradation. It is concluded that non-press-fit implantation of apatite-coated implants leads to more bone apposition as compared to uncoated Ti-6A1-4V implants. However, it is suggested by these results that the upper limit of gaps around apatite implants is 2 millimeters in a non-weight-bearing model in goats. Bone apposition will not increase by extending the follow-up period more than six weeks, nor will it be altering the stability of the apatite coatings used.

Animals↗

In vivo dissolution behavior of various RF magnetron sputtered Ca-P coatings.

Radiofrequency magnetron sputter deposition was used to deposit Ca-P sputter coatings on titanium discs, and these coatings were implanted subcutaneously into the backs of rabbits. Half of the as-sputtered coatings were subjected to additional heat treatment for 2 h at 500 degrees C. X-ray diffraction (XRD) demonstrated that annealing at 500 degrees C changed the amorphous sputtered coating into an amorphous-crystalline apatite structure. Scanning electron microscopic (SEM) examination of the sputtered coatings showed excellent coverage of the substrate surface. Annealing of the 4-microm-thick coatings resulted in the appearance of small cracks. SEM demonstrated that until 4 weeks of implantation, all heat-treated coatings were present and all amorphous coatings were completely or mostly dissolved. Fourier transform infrared spectroscopy showed the formation of carbonate apatite (CO3-AP) on these specimens. Furthermore, XRD analysis showed that these CO3-AP precipitated coatings disappeared after 8 weeks of implantation. On the other hand, SEM inspection of these specimens revealed that the 4-microm heat-treated coating was still partially maintained and that small Ca-P crystals were present on the titanium substrate. On the basis of these results, we conclude that apparently 0.1 microm heat-treated Ca-P sputter coating is of sufficient thicknesses to stimulate carbonate apatite deposition under in vivo conditions.

Animals↗

Preparation of calcium phosphate coatings on titanium implant materials by simple chemistry.

A two-step chemical treatment has been developed in our group to prepare commercially pure titanium (cpTi) surfaces that will allow calcium phosphate (Ca-P) precipitation during immersion in a supersaturated calcification solution (SCS) with ion concentrations of [Ca2+] = 3.10 mM and [HPO4(2-)] = 1.86 mM. It was observed that a precalcification (Pre-Ca) procedure prior to immersion could significantly accelerate the Ca-P deposition process. In this work, the bioactivity of chemically treated cpTi and Ti6Al4V was further verified by applying commercially available Hanks' balanced salt solution (HBSS), an SCS with very low ion concentrations of [Ca2+] = 1.26 mM and [HPO4(2-)] = 0.779 mM, as the immersion solution. It was found that a uniform and very dense apatite coating magnesium impurities was formed if the Pre-Ca procedure was performed before immersion, as compared with the loose Ca-P layer obtained from the abovementioned high concentration of SCS. The formation of a microporous titanium dioxide thin surface layer on cpTi or Ti6Al4V by the two-step chemical treatment could be the main reason for the induction of apatite nucleation and growth from HBSS. Variations of pH values, Ca and P concentrations, and immersion time in HBSS were investigated to reveal the detailed process of Ca-P deposition. The described treatments provide a simple chemical method to prepare Ca-P coatings on both cpTi and Ti6Al4V.

Alloys↗

Tensile tests of interface between bone and plasma-sprayed HA coating-titanium implant.

Tensile strength testing of the interface between bone and a plasma-sprayed hydroxyapatite (HA) coating-Ti-6Al-4V (implant I) and an HA coating-Ti (implant II) was performed. The bone-implant interface and tensile failure mode were evaluated by light microscopy (LM), SEM-energy dispersive X-ray analysis, and backscattered electron imaging. The crystallinity of the HA coating of implant I and implant II was 62 and 40%, respectively. Eleven semidisk implants of each type were inserted in the left tibia of 22 rabbits in each period. After 2, 4, 8, and 16 weeks, the tensile strength of the bone-implant I was 0.86, 1.32, 1.10, and 0.92 MPa, respectively; the value of the bone-implant II was 0.66, 0.92, 0.84, and 1.12 MPa, respectively. No significant difference was found in tensile strength between implant I and implant II, and between the data of different periods. LM and SEM revealed that the two types of coatings behave the same in bone. Failure after the tensile test mainly occurred at the bony tissue at 2 and 4 weeks, inside the HA coating layer at 8 weeks, and at the HA coating-metal substrate interface at 16 weeks. Degradation and delamination of the HA coating continued with time, resulting in the interfacial tensile strength not increasing with time. Thus, we concluded that differences between the two implants, mainly the difference in crystallinity of the HA coating (62 vs. 40%), have no significant influence on bone bonding ability, bone bonding strength, tensile failure mode, and degradation of the coating.

Animals↗

Subperiosteal implantation of various RF magnetron sputtered Ca-P coatings in goats.

The aim of this study was to obtain more information about the initial biological events around RF magnetron sputtered calcium phosphate (Ca-P) coatings. Therefore, uncoated and coated disks were inserted subperiosteal into the tibia of a goat. The coatings were deposited on commercially pure titanium. The thickness of the coating was 0.1 or 2.0 microm. All the as-sputtered coatings were subjected to an additional heat treatment for 2 h at 500 degrees C. After 1 and 3 weeks of implantation the experimental disks were retrieved and prepared for histological and physicochemical analysis. The histological results demonstrated that the periosteum covered the specimens after both implantation periods. In between the periosteum and implant an acellular layer and a collagen matrix was observed. Energy dispersive spectrometry revealed that the acellular layer consisted of C, Ca, and P ions for the 0.1 microm thick Ca-P coatings. The 2 microm thick Ca-P coatings also showed the presence of sulfate ions in this layer. Only organic material was found on the titanium disks. Further, SEM showed that even after 3-week implantation, a substantial thickness of both coatings was still maintained. Thin film X-ray diffraction demonstrated that after both implantation periods, the CaP-0.1 coating was still present. FTIR of the retrieved specimens demonstrated on the coated disks the formation of additional carbonate apatite (CO3-AP) associated with an organic phase (NH2 groups). On basis of these findings we conclude that our experimental approach is very suitable for the investigation of the healing process around Ca-P coatings. Further, we again demonstrated that the initial interfacial response to Ca-P materials differs from titanium.

Animals↗

Surface modification of nano-apatite by grafting organic polymer.

Since surface properties of hydroxyapatite (HA) play an important role in its performance, surface modification of HA has gained much attention from researchers. Silane coupling agents have been the focus of the research. In this study, an effective surface modification method was developed using hexamethylene diisocyanate as a coupling agent. Polyethylene glycol (Mw = 1500) was successfully coupled to the surface of nano-size apatite particles (nano-apatite). Various methods were used to characterize the surface-modified nano-apatite. Infra-red spectra confirmed the existence of a layer of polymer with both urethane and ether linkage on the surface of nano-apatite. The amount of grafted polymer as determined by total organic carbon analysis (TOC) and thermal gravimetric analysis (TGA) was about 20% in weight. Solid 1H MAS NMR spectra indicated that the amount of hydroxyl groups of nano-apatite was decreased by 7.7% after surface grafting reaction. It is concluded that the surface hydroxyl groups of nano-apatite have the reactivity towards isocyanate groups.

Carbon↗

Wegener's granulomatosis: disease course, assessment of activity and extent and treatment.

Wegener's granulomatosis (WG) belongs to the group of necrotizing primary systemic vasculitides of unknown etiology, that are associated with anti-neutrophil cytoplasmic antibodies. The pathological hallmark of WG is the coexistence of vasculitis and granuloma. Due to more sensitive diagnostic instruments, especially ANCA testing, the incidence of diagnosis of WG has risen in the past ten years. Although the precise pathophysiology is not understood yet, there is ample evidence that ANCA, which can lead to cytotoxic reactions in the vascular texture, play a major role, possibly promoted by a dysbalance in the anti-idiotypic network. The clinical disease course is typically two-phasic, beginning with a granulomatous inflammation of the upper respiratory tract, that usually is followed by a generalized vasculitic phase, that can range from mild organ dysfuntion to life threatening multi-organ failure. Consequently, diagnostic procedures, patients' assessment and therapeutic regimens need to be individualized, adapted to stage and activity of the disease as well as standardized.

Granulomatosis with Polyangiitis↗

Calcium phosphate coatings for medical implants.

In surgical disciplines where bone has to be repaired, augmented or improved, bone substitutes are essential. Although bone banks, such as Eurotransplant, are founded to supply such substitutes, natural bone is not always adequate. For example, frequently these so-called bone grafts resorb after implantation (1). Further, they cannot be used for joint and tooth replacement, and recently worries have been raised about the transfer of infectious diseases. Therefore, interest has dramatically increased in the use of synthetic materials for replacement of lost or damaged bone tissue. The generic name of these tissue alternatives is biomaterials. A special class of these biomaterials is composed of metallic devices with coatings to improve bone bonding. These specialized coatings used to improve the metallic implant are the topic of this paper.

Adhesiveness↗

Induction of remission in Wegener's granulomatosis with low dose methotrexate.

OBJECTIVE: To study the efficacy of methotrexate (MTX) plus low dose corticosteroids for induction of remission in generalized Wegener's granulomatosis (WG) and to possibly identify predictive factors for the outcome under this therapy. METHODS: We conducted a prospective, open label study, including 17 patients with not immediately life threatening, generalized WG. Treatment consisted of intravenous MTX 0.3 mg/kg once weekly plus daily oral low dose prednisone for initial diagnosis of WG in 11 and for a generalized relapse of WG in 6 patients. Interdisciplinary, standardized assessments of disease activity and extent were done 3-monthly. RESULTS: Within a median treatment period of 24.5 months remission could be achieved in 10/17 patients (59%), their median corticosteroid dose during that time was 1.75 mg/day. Seven patients with a median concomitant prednisone dose of 7.5 mg/day did not respond, among them 4 patients who were treated for a relapse of WG. Signs of de novo glomerulonephritis occurred in 5 of the 7 nonresponders. Significant side effects, including opportunistic infections, did not occur. CONCLUSION: Weekly low dose MTX in combination with low dose corticosteroids leads to an acceptable remission rate of almost 60% without significant side effects. Patients treated for a relapse of WG and patients with a need for a higher concomitant prednisone dose seem to be at risk for nonresponse, with a high likelihood of developing de novo glomerulonephritis.

Anti-Inflammatory Agents↗

Comparison of eight commercial kits for quantitation of antineutrophil cytoplasmic antibodies (ANCA).

Antineutrophil cytoplasmic antibodies (ANCA) are used as diagnostic markers for systemic vasculitis. However, the specificity and sensitivity of ANCA detection differs from centre to centre due in large part to variations in methodology. We compared 8 commercial ELISA kits and an in-house method (HM) for their specificity and sensitivity in detecting ANCA against proteinase 3 (PR3-ANCA, 7 kits) and meyloperoxidse (MPO-ANCA, 8 kits). Sera from 5 patients with systemic lupus erythematosus (SLE), 28 with Wegener's granulomatosis (WG), 22 with microscopic polyangiitis (MPA), 5 with idiopathic rapidly progressive glomerulonephritis (RPGN), and 5 healthy controls were examined by both the indirect immunofluorescence technique (IFT) and the ELISA kits. Sera from healthy controls and patients with SLE or cANCA-negative WG were shown to be PR3-ANCA negative by all 7 PR3-ANCA kits. In 25 cANCA-positive sera from WG patients, PR3-ANCA positivity ranged from 44% to 84%. An absolute concordance among the 7 kits was noted in 56% of the cANCA-positive samples. The PR3-ANCA levels in 5 of the 7 kits correlated with the cANCA titers in IFT. Sera from the healthy controls and 4 out of the 5 SLE and pANCA-negative patients were found to be MPO-ANCA negative in all 8 MPO-ANCA kits. In 20 pANCA-positive sera, MPO-ANCA positivity ranged from 25% to 75%. Thirty-five percent of MPO-ANCA-positive sera were confirmed by capture ELISA, immunoblot and inhibition assay. The concordance rate was only 30% among pANCA-positive sera in the 8 MPO-ANCA kits. No significant correlation was observed between pANCA titers and MPO-ANCA levels. The HM showed that 65% of cANCA-positive sera were PR3-ANCA positive, and 45% of pANCA-positive sera were MPO-ANCA positive. Our results indicate that the sensitivities and specificities for ANCA detection differ significantly among the commercial kits tested and underline the necessity of establishing uniform international standards for ANCA ELISA procedures in order to permit more reliable interpretation and comparison of data.

Antibodies, Antineutrophil Cytoplasmic↗

Renal graft rejection or urinary tract infection? The value of myeloperoxidase, C-reactive protein, and alpha2-macroglobulin in the urine.

Previous investigations have shown that the determination of two acute-phase proteins in the urine, C-reactive protein (CRPu) and alpha2-macroglobulin (alpha2-MGu), allows a noninvasive diagnosis of acute renal graft dysfunction. A reliable differentiation between rejection and urinary tract infection can be made only when considering the C-reactive protein in serum and urine at the same time (CRPs:CRPu ratio). Therefore, a diagnostic procedure independent of parameters other than urinary proteins is needed. As granulocytes play only a minor role in graft rejection but are a common feature in urinary tract infection, we determined a marker of granulocytes (myeloperoxidase) in urine (MPOu). Eighty-nine renal transplant recipients were included in the study. In normal courses, CRPu, alpha2-MGu, and MPOu were within the normal range. In 15 cases of acute interstitial rejection, an increased excretion of CRPu and alpha2-MGu could be confirmed, but MPOu could not be detected. On the occasion of acute vascular rejection (n=6), with the exception of one case, MPOu could not be observed. The pattern of the three urinary proteins differed in urinary tract infections (n=40): MPOu could be detected in all cases, CRPu in 50% of cases, and alpha2-MGu in 73% of cases. In patients with cytomegalovirus infection (n=7), no MPOu, CRPu, or alpha2-MGu was found. In conclusion, the simultaneous measurement of the three proteins allows a complete, noninvasive, differential diagnostic procedure of renal graft dysfunction.

Biomarkers↗

Healing of gaps around calcium phosphate-coated implants in trabecular bone of the goat.

Hydroxylapatite coatings are under clinical investigation in orthopaedics and dentistry. Bone formation on apatite coatings in the presence of gaps is important for clinical applications. The importance of the stability of the coating is not known at present. By varying the plasma-spray parameters, and by the addition of fluoride, the crystallinity and stability of calcium phosphates can be changed. It is suggested that bone formation is enhanced by dissolution of the apatite coating. We studied apatite coatings of varying stability with regard to their gap-healing characteristics, and we examined what the maximum gap would be that can be bridged if a coating is applied. Ti-6A1-4V implants coated with 62% crystalline hydroxylapatite, 30% crystalline hydroxylapatite or fluorapatite, or noncoated Ti-6A1-4V were implanted in 16 goats. The implants were surrounded by gaps of 1 or 2 mm, and the follow-up period was 6 weeks. Histological examination and histometry revealed that gaps of 1 mm can be bridged by bone if an apatite coating is applied. However, only a minimal amount of bone contact was seen on the apatite coatings with 2 mm gaps. Uncoated implants demonstrated no bone contact at all. Among the three different coatings there were no differences in gap healing. It can be concluded that in the goat, gaps of 2 or more mm between coated implants and host bone tissue inhibit bone deposition on the coating (p < 0.05), but the stability of the coating does not influence gap-healing characteristics.

Alloys↗