Search PubMed⌕ Search

Biomedical subjects

K W Preidler

Publications and source records attributed to K W Preidler.

44 records · Page 3Linked to original sources

Imaging of osteoarthritis.

Osteoarthritis represents the most common joint disorder affecting humans. This article describes the cause of this disease, the radiographic-pathologic correlation, and particularly the radiographic appearance of osteoarthritis in the hip and the knee.

Arthrography↗

Cerebral schistosomiasis: MR and CT appearance.

After returning from Africa, a 54-year-old man began to have episodes of headache and nausea, then a cerebral convulsion. Clinical and laboratory findings and response to chemotherapy indicated the diagnosis of cerebral schistosomiasis. Three lesions were seen on CT and MR studies: two appeared to be subacute intracerebral hematomas, one in the right parietal lobe and one in the frontal lobe; the third lesion, in the cortex of the left occipital lobe, appeared to be a cyst. These lesions could represent small granulomatous tissue reactions with secondary hemorrhages.

Brain Diseases↗

Technical note: comparison of colour Doppler energy sonography with conventional colour Doppler sonography in detection of flow signal in peripheral renal transplant vessels.

The technical advantage of colour Doppler energy sonography (CDE) results in a higher sensitivity for blood flow detection than in conventional colour Doppler sonography (CDI). We compared the efficiency of CDE versus CDI in the detection of blood flow signals in asymptomatic patients after renal transplantation. 10 asymptomatic voluntary patients after renal transplantation were evaluated with CDI and subsequently with CDE by two examiners. Filter, scale and gate setting were kept constant, the Doppler gain was increased individually in every patient until background noise just did not derange the image. The assessment of blood flow signal was done using a self defined score system. CDI showed Doppler signal in the interlobar vessels in all 10 patients and blood flow signal in arcuate arteries and adjacent portions of interlobular vessels in nine of 10 patients. We were not able to detect blood flow related signal in the more peripheral medullary and cortical vessels. CDE obtained blood flow signal in interlobar and interlobular vessels in all patients. In addition, Doppler signal was observed in all patients in small medullary and cortical vessels. CDE increases detection of blood flow related signal in peripherally located small medullary and cortical vessels. There was no improvement in the evaluation of blood flow in interlobar vessels but marked improvement in blood flow detection in small peripherally located vessels. CDE cannot completely replace CDI in the sonographic evaluation of vascular complications in renal transplants, but should be used as an additional measure to rule out pathology in small peripheral renal vessels.

Adult↗

[Non-granulomatous prostatitis: MRI image with endorectal surface coil ("Endo-MRI")].

Inflammatory conditions of the prostate are often difficult to distinguish from early stages of prostate cancer with imaging techniques. The use of an endorectal surface coil in MRI of the prostate gland has been reported to provide superior resolution and better imaging of details than MRI with a body coil in the diagnosis of early prostate cancer. We report a 34-year-old patient with nonspecific non-granulomatous prostatitis in whom T2-weighted endorectal surface coil magnetic resonance imaging (ESCMRI) showed a region of markedly decreased signal intensity in the periphery of the gland. The low signal intensity of the lesion, its sharp demarcation from the normal part of the peripheral zone of the prostate and the marked bulge of the surface contour without capsular breach of the organ were interpreted as evidence of a bioptically proven benign inflammatory condition.

Adult↗

[Fluoroscopically guided percutaneous fine-needle biopsy of the lung using the ROTEX needle: results in 890 patients with focal lung lesions].

Fluoroscopically guided transthoracic fine needle biopsies were performed in 890 patients (380 female, 582 male, mean age: 56 years). In 795 patients (89.4%) the first biopsy was successful. The success rate of biopsy correlated closely with the size of the lesion and increased with larger size. Sensitivity in the diagnosis of malignant lesions was 94.6%, specificity 99.5%. Due to cytological, histological, and clinical confirmation of benign lung lesions in 300 patients (33.7% of all patients), the number of unnecessary diagnostic thoracotomies for benign disease could be reduced significantly. In 9 of 113 cases (8%) histological reclassification of the cytologic results was necessary. Reclassification was not necessary in the differentiation between benign and malignant lesions and between small cell and non-small cell carcinomas. The overall complication rate was 24.7% (220 patients). Only 36 patients (4% of all patients) required chest-tube insertion. There were no fatal complications. Percutaneous fluoroscopically guided transthoracic fine needle biopsy of the lung, performed with the Rotex needle, is a time-effective, safe, and efficient method for diagnosing focal pulmonary lesions.

Adenocarcinoma↗