Search PubMed⌕ Search

Biomedical subjects

K Ugurbil

Publications and source records attributed to K Ugurbil.

At least 19 recordsLinked to original sources

Neural correlates of encoding and expression in implicit sequence learning.

In the domain of motor learning it has been difficult to separate the neural substrate of encoding from that of change in performance. Consequently, it has not been clear whether motor effector areas participate in learning or merely modulate changes in performance. Here, using a variant of the serial reaction time task that dissociated these two factors, we report that encoding during procedural motor learning does engage cortical motor areas and can be characterized by distinct early and late encoding phases. The highest correlation between activation and subsequent changes in motor performance was seen in the motor cortex during early encoding, and in the basal ganglia during the late encoding phase. Our results show that rapid encoding during procedural motor learning involves several distinct processes, and is represented primarily within motor system structures.

Adult↗

Efficient high-frequency body coil for high-field MRI.

The use of body coils is favored for homogeneous excitation, and such coils are often paired with surface coils or arrays for sensitive reception in many MRI applications. While the body coil's physical size and resultant electrical length make this circuit difficult to design for any field strength, recent efforts to build efficient body coils for applications at 3T and above have been especially challenging. To meet this challenge, we developed an efficient new transverse electromagnetic (TEM) body coil and demonstrated its use in human studies at field strengths up to 4 T. Head, body, and breast images were acquired within peak power constraints of <8 kW. Bench studies indicate that these body coils are feasible to 8 T. RF shimming was used to remove a high-field-related cardiac imaging artifact in these preliminary studies. P41RR13230

Equipment Design↗

Detunable transverse electromagnetic (TEM) volume coil for high-field NMR.

Most high-field MRI systems do not have the actively detuned body coils that are integral to clinical systems operating at 1.5T and lower field strengths. Therefore, many clinical applications requiring homogeneous volume excitation in combination with local surface coil reception are not easily implemented at high fields. To solve this problem for neuroimaging applications, actively detunable transverse electromagnetic (TEM) head coils were developed to be used with receive-only surface coils for signal-to-noise ratio (SNR) gains and improved spatial coverage from homogeneously excited regions. These SNR and field of view (FOV) gains were achieved by application of a detunable TEM volume coil to human brain imaging at 4T.

Brain↗

Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz.

Calculations and experiments were used to examine the B(1) field behavior and signal intensity distribution in a 16-cm diameter spherical phantom excited by a 10-cm diameter surface coil at 300 MHz. In this simple system at this high frequency very complex RF field behavior exists, resulting in different excitation and reception distributions. Included in this work is a straightforward demonstration that coil receptivity is proportional to the magnitude of the circularly polarized component of the B(1) field that rotates in the direction opposite to that of nuclear precession. It is clearly apparent that even in very simple systems in head-sized samples at this frequency it is important to consider the separate excitation and reception distributions in order to understand the signal intensity distribution.

Head↗

Functional imaging of brain activity in conscious monkeys responding to sexually arousing cues.

Olfactory cues can elicit intense emotional responses. This study used fMRI in male common marmoset monkeys to identify brain areas associated with sexual arousal in response to odors of ovulating female monkeys. Under light anesthesia, monkeys were secured in a specially designed restrainer and positioned in a 9.4 T magnetic resonance spectrometer. When fully conscious, they were presented with the scents of both ovariectomized and ovulating monkeys. The sexually arousing odors of the ovulating monkeys enhanced signal intensity in the preoptic area and anterior hypothalamus compared to the odors of ovariectomized monkeys. These data corroborate previous findings in monkeys based on invasive electrical lesion and stimulation techniques and demonstrate the feasibility of using non-invasive functional imaging on fully conscious common marmosets to study cue-elicited emotional responses.

Animals↗

Study of tricarboxylic acid cycle flux changes in human visual cortex during hemifield visual stimulation using (1)H-[(13)C] MRS and fMRI.

The relationships between brain activity and accompanying hemodynamic and metabolic alterations, particularly between the cerebral metabolic rate of oxygen utilization (CMR(O2)) and cerebral blood flow (CBF), are not thoroughly established. CMR(O2) is closely coupled to the rate of tricarboxylic acid (TCA) cycle flux. In this study, the changes in glutamate labeling during (13)C labeled glucose administration were determined in the human brain as an index of alterations in neuronal TCA cycle turnover during increased neuronal activity. Two-volume (1)H-[(13)C] MR spectroscopy (MRS) of the visual cortex was combined with functional MRI (fMRI) at 4 Tesla. Hemifield visual stimulation was employed to obtain data simultaneously from activated and control regions located symmetrically in the two hemispheres of the brain. The results showed that the fractional change in the turnover rate of C4 carbon of glutamate was less than that of CBF during visual stimulation. The fractional changes in CMR(O2) (Delta CMR(O2)) induced by activation must be equal to or less than the fractional change in glutamate labeling kinetics. Therefore, the results impose an upper limit of approximately 30% for Delta CMR(O2) and demonstrate: 1) that fractional CBF increases exceed Delta CMR(O2) during elevated activity in the visual cortex, and 2) that such an unequal change would explain the observed positive blood oxygenation level dependent (BOLD) effect in fMRI. Magn Reson Med 45:349-355, 2001.

Blood Glucose↗

17O relaxation time and NMR sensitivity of cerebral water and their field dependence.

17O spin relaxation times and sensitivity of detection were measured for natural abundance H(2)(17)O in the rat brain at 4.7 and 9.4 Tesla. The relaxation times were found to be magnetic field independent (T(2) = 3.03 +/- 0.08 ms, T(*)(2) = 1.79 +/- 0.04 ms, and T(1) = 4.47 +/- 0.14 ms at 4.7T (N = 5); T(2) = 3.03 +/- 0.09 ms, T(*)(2) = 1.80 +/- 0.06 ms, and T(1) = 4.84 +/- 0.18 ms at 9.4T (N = 5)), consistent with the concept that the dominant relaxation mechanism is the quadrupolar interaction for this nucleus. The (17)O NMR sensitivity was more than fourfold higher at 9.4T than at 4.7T, for both the rat brain and a sodium chloride solution. With this sensitivity gain, it was possible to obtain localized (17)O spectra with an excellent signal-to-noise ratio (SNR) within 15 s of data acquisition despite the relatively low gyromagnetic ratio of this nucleus. Such a 15-s 2D (17)O-MRS imaging data set obtained for natural abundance H(2)(17)O in the rat brain yielded an SNR greater than 40:1 for a approximately 16 microl voxel. This approach was employed to measure cerebral blood flow using a bolus injection of H(2)(17)O via one internal carotid artery. These results demonstrate the ability of (17)O-MRS imaging to reliably map the H(2)(17)O dynamics in the brain tissue, and its potential for determining tissue blood flow and oxygen consumption rate changes in vivo. Magn Reson Med 45:543-549, 2001.

Animals↗

Imaging brain function in humans at 7 Tesla.

This article describes experimental studies performed to demonstrate the feasibility of BOLD fMRI using echo-planar imaging (EPI) at 7 T and to characterize the BOLD response in humans at this ultrahigh magnetic field. Visual stimulation studies were performed in normal subjects using high-resolution multishot EPI sequences. Changes in R(*)(2) arising from visual stimulation were experimentally determined using fMRI measurements obtained at multiple echo times. The results obtained at 7 T were compared to those at 4 T. Experimental data indicate that fMRI can be reliably performed at 7 T and that at this field strength both the sensitivity and spatial specificity of the BOLD response are increased. This study suggests that ultrahigh field MR systems are advantageous for functional mapping in humans. Magn Reson Med 45:588-594, 2001.

Brain↗

7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Signal-to-noise ratio (SNR), RF field (B(1)), and RF power requirement for human head imaging were examined at 7T and 4T magnetic field strengths. The variation in B(1) magnitude was nearly twofold higher at 7T than at 4T ( approximately 42% compared to approximately 23%). The power required for a 90 degrees pulse in the center of the head at 7T was approximately twice that at 4T. The SNR averaged over the brain was at least 1.6 times higher at 7T compared to 4T. These experimental results were consistent with calculations performed using a human head model and Maxwell's equations. Magn Reson Med 46:24-30, 2001.

Brain↗

Microstrip RF surface coil design for extremely high-field MRI and spectroscopy.

A new type of high-frequency RF surface coil was developed for in vivo proton or other nuclei NMR applications at 7T. This is a purely distributed-element and transmission line design. The coil consists of a thin strip conductor (copper or silver) and a ground plane separated by a low-loss dielectric material with a thickness (H). Due to its specific semi-open transmission line structure, substantial electromagnetic energy is stored in the dielectric material between the thin conductor and the ground plane, which results in a reduced radiation loss and a reduced perturbation of sample loading to the RF coil compared to conventional surface coils. The coil is characterized by a high Q factor, no RF shielding, small physical coil size, lower cost, and easy fabrication. A brief theoretical description of the microstrip RF coil is given that can be used to guide the coil designs. A set of gradient-recalled echo images were acquired by using the single- and two-turn microstrip RF surface coils from both phantom and human brain at 7T, which show good penetration and sensitivity. The two-turn coil design significantly improves the B1 symmetry as predicted by the microstrip theory. The optimum H for microstrip surface coils is approximately 7 mm. This coil geometry yields a B1 penetration similar to that of conventional surface coils. SNR comparison was made between the microstrip coil and conventional surface coils with and without RF shielding. The results reveal that the novel surface coil design based on the microstrip concept makes very high-field MRI/MRS more convenient and efficient in research and future clinics.

Artifacts↗

In vivo 1H NMR spectroscopy of the human brain at 7 T.

In vivo 1H NMR spectra from the human brain were measured at 7 T. Ultrashort echo-time STEAM was used to minimize J-modulation and signal attenuation caused by the shorter T2 of metabolites. Precise adjustment of higher-order shims, which was achieved with FASTMAP, was crucial to benefit from this high magnetic field. Sensitivity improvements were evident from single-shot spectra and from the direct detection of glucose at 5.23 ppm in 8-ml volumes. The linewidth of the creatine methyl resonance was at best 9 Hz. In spite of the increased linewidth of singlet resonances at 7 T, the ability to resolve overlapping multiplets of J-coupled spin systems, such as glutamine and glutamate, was substantially increased. Characteristic spectral patterns of metabolites, e.g., myo-inositol and taurine, were discernible in the in vivo spectra, which facilitated an unambiguous signal assignment.

Adult↗

The effect of stimulus-response compatibility on cortical motor activation.

Stimulus-response compatibility (SRC) is a general term describing the relationship between a triggering stimulus and its associated motor response. The relationship between stimulus and response can be manipulated at the level of the set of stimulus and response characteristics (set-level) or at the level of the mapping between the individual elements of the stimulus and response sets (element-level). We used functional magnetic resonance imaging (fMRI) to investigate the effects of SRC on functional activation in cortical motor areas. Using behavioral tasks to separately evaluate set- and element-level compatibility, and their interaction, we measured the volume of functional activation in 11 cortical motor areas, in the anterior frontal cortex, and in the superior temporal lobe. Element-level compatibility effects were associated with significant activation in the pre-supplementary motor area (preSMA), the dorsal (PMd) and ventral (PMv) premotor areas, and the parietal areas (inferior, superior, intraparietal sulcus, precuneus). The activation was lateralized to the right hemisphere for most of the areas. Set-level compatibility effects resulted in significant activation in the inferior frontal gyri, anterior cingulate and cingulate motor areas, the PMd, PMv, preSMA, the parietal areas (inferior, superior, intraparietal sulcus, precuneus), and in the superior temporal lobe. Activation in the majority of these areas was lateralized to the left hemisphere. Finally, there was an interaction between set and element-level compatibility in the middle and superior frontal gyri, in an area co-extensive with the dorsolateral prefrontal cortex, suggesting that this area provided the neural substrate for common processing stages, such as working memory and attention, which are engaged when both levels of SRC are manipulated at once.

Adult↗

A mathematical model of compartmentalized neurotransmitter metabolism in the human brain.

After administration of enriched [1-13C]glucose, the rate of 13C label incorporation into glutamate C4, C3, and C2, glutamine C4, C3, and C2, and aspartate C2 and C3 was simultaneously measured in six normal subjects by 13C NMR at 4 Tesla in 45-ml volumes encompassing the visual cortex. The resulting eight time courses were simultaneously fitted to a mathematical model. The rate of (neuronal) tricarboxylic acid cycle flux (V(PDH)), 0.57 +/- 0.06 micromol. g(-1). min(-1), was comparable to the exchange rate between (mitochondrial) 2-oxoglutarate and (cytosolic) glutamate (Vx), 0.57 +/- 0.19 micromol. g(-1). min(-1)), which may reflect to a large extent malate-aspartate shuttle activity. At rest, oxidative glucose consumption [CMR(Glc(ox))] was 0.41 +/- 0.03 miccromol. g(-1). min(-1), and (glial) pyruvate carboxylation (VPC) was 0.09 +/- 0.02 micromol. g(-1). min(-1). The flux through glutamine synthetase (Vsyn) was 0.26 +/- 0.06 micromol. g(-1). min(-1). A fraction of Vsyn was attributed to be from (neuronal) glutamate, and the corresponding rate of apparent glutamatergic neurotransmission (VNT) was 0.17 +/- 0.05 micromol. g(-1). min(-1). The ratio [VNT/CMR(Glcox)] was 0.41 +/- 0.14 and thus clearly different from a 1:1 stoichiometry, consistent with a significant fraction (approximately 90%) of ATP generated in astrocytes being oxidative. The study underlines the importance of assumptions made in modeling 13C labeling data in brain.

Algorithms↗

Myocardial oxygenation and high-energy phosphate levels during graded coronary hypoperfusion.

This study was performed to determine the myocyte PO(2) required to sustain normal high-energy phosphate (HEP) levels in the in vivo heart. In 10 normal dogs, myocyte PO(2) values were calculated from the myocardial deoxymyoglobin resonance (Mb-delta) intensity determined with (1)H-NMR spectroscopy during sequential flow reductions produced by a hydraulic occluder that decreased coronary perfusion pressure to approximately 60, 50, and 40 mmHg and, finally, during total occlusion. Myocardial blood flow was measured with microspheres, and HEP levels were determined with (31)P magnetic resonance spectroscopy. During control conditions, Mb-delta was undetectable. Myocardial blood flow was 1.11 +/- 0.06 ml. min(-1). g(-1) during basal conditions and decreased with sequential graded occlusions to 0.78 +/- 0.05, 0.58 +/- 0.03, and 0.38 +/- 0.04 ml. min(-1). g(-1), respectively; blood flow during total occlusion was 0.07 +/- 0.02 ml. min(-1). g(-1). Reductions of blood flow caused progressive increases of Mb-delta, which were associated with decreases of phosphocreatine (PCr), ATP, and the PCr-to-ATP ratio, as well as progressive increases of the P(i)-to-PCr ratio. There was a strong linear correlation between normalized blood flow and Mb-delta (R(2) = 0.89, P < 0.01). Reductions of HEP and PO(2) were also highly correlated (although nonlinearly); with the assumption that myoglobin was 90% saturated with O(2) during basal conditions and 5% saturated during total coronary occlusion, the intracellular PO(2) values for 20% reductions of PCr and ATP were approximately 4. 4 and approximately 0.9 mmHg, respectively. The data indicate that O(2) availability plays an increasing role in regulation of oxidative phosphorylation when mean intracellular PO(2) values fall below 5 mmHg in the in vivo heart.

Adenosine Diphosphate↗

Noninvasive measurements of transmural myocardial metabolites using 3-D (31)P NMR spectroscopy.

A completely noninvasive three-dimensional (3-D) static magnetic field magnitude spatially localized (31)P spectroscopy technique has been developed and applied to study the in vivo canine myocardium at 9.4 T. The technique incorporates both Fourier series windows and selective Fourier transform methods utilizing all three orthogonal gradients for 3-D phase encoding. The number of data acquisitions for each phase-encoding step was weighted according to the Fourier coefficients to define cylindrical voxels. Spatially localized (31)P spectra can be generated for voxels of desired location within the field of view as a postprocessing step. The quality of localization was first demonstrated by using a three-compartment phantom. The technique was then applied to in vivo canine models and yielded (31)P cardiac spectra with an excellent signal-to-noise ratio. The in vivo validation experiments, using an implanted 2-phosphoenolpyruvate-containing marker, demonstrated that the technique is capable of measuring at least two transmural layers of left ventricular myocardium representing the subepicardium and subendocardium.

Adenosine Triphosphate↗

Effects of augmented delivery of pyruvate on myocardial high-energy phosphate metabolism at high workstate.

This study was performed to determine whether the fall in myocardial high-energy phosphates (HEP) that occurs during high workstates can be ascribed to either inadequate glycolytic pyruvate generation and conversion to acyl-CoA or limitation of long-chain fatty acid transport into the mitochondria. This was tested by using infusions of either pyruvate or butyrate in anesthetized dogs. Pyruvate was used because it bypasses the glycolytic sequence of reactions, activates pyruvate dehydrogenase, and increases mitochondrial NADH concentration ([NADH(m)]) in isolated myocardium, whereas butyrate enters the mitochondria without need for transport by the rate-limiting, palmitoyl-carnitine transporter. Increasing blood pyruvate from 0.16 +/- 0.016 mM to >3 mM did not alter baseline HEP levels determined with (31)P nuclear magnetic resonance, but caused an increase in the rate-pressure product and a modest increase in myocardial oxygen consumption (MVO(2)). Infusion of dobutamine + dopamine (each 20 microg x kg(-1) x min(-1) iv) increased MVO(2) and caused decreases of myocardial phosphocreatine (PCr)/ATP. Pyruvate partially reversed the decrease of HEP levels produced by catecholamine stimulation, whereas butyrate had no effect. Neither pyruvate nor butyrate caused an increase of MVO(2) during catecholamine infusion. Deoxymyoglobin was not detected by (1)H magnetic resonance spectroscopyy in any group. The data demonstrate that carbon substrate availability to the mitochondria is not the only cause of the reduction of PCr/ATP that occurs at high workstates. Supplemental pyruvate (but not butyrate) attenuated the reduction of PCr/ATP during the high workstates; this may have resulted from direct effects on intermediary metabolism or from other effects such as the free radical scavenging activity of pyruvate.

Adenosine Triphosphate↗

An approach to probe some neural systems interaction by functional MRI at neural time scale down to milliseconds.

In this paper, we demonstrate an approach by which some evoked neuronal events can be probed by functional MRI (fMRI) signal with temporal resolution at the time scale of tens of milliseconds. The approach is based on the close relationship between neuronal electrical events and fMRI signal that is experimentally demonstrated in concurrent fMRI and electroencephalographic (EEG) studies conducted in a rat model with forepaw electrical stimulation. We observed a refractory period of neuronal origin in a two-stimuli paradigm: the first stimulation pulse suppressed the evoked activity in both EEG and fMRI signal responding to the subsequent stimulus for a period of several hundred milliseconds. When there was an apparent site-site interaction detected in the evoked EEG signal induced by two stimuli that were primarily targeted to activate two different sites in the brain, fMRI also displayed signal amplitude modulation because of the interactive event. With visual stimulation using two short pulses in the human brain, a similar refractory phenomenon was observed in activated fMRI signals in the primary visual cortex. In addition, for interstimulus intervals shorter than the known latency time of the evoked potential induced by the first stimulus ( approximately 100 ms) in the primary visual cortex of the human brain, the suppression was not present. Thus, by controlling the temporal relation of input tasks, it is possible to study temporal evolution of certain neural events at the time scale of their evoked electrical activity by noninvasive fMRI methodology.

Animals↗

Functional suppression of long-term sustained response in the human hippocampal formation due to memory distraction.

Functional magnetic resonance imaging is used to investigate physiological dynamics in the human hippocampal formation due to memory distraction. A finger-movement task executed following a verbal memory task resulted in decreased verbal memory scores and shortening of active response in the hippocampal formation and the cerebellar dentate nucleus. Verbal rehearsal was excluded as an explanation because this sustained activation was approximately three-fold longer than the duration of the post-task activation observed in classical language processing regions such as Wernicke's and Broca's areas. These interference phenomena provide a physiological basis of memory distraction in the hippocampal formation.

Adult↗