Search PubMed⌕ Search

Biomedical subjects

K Torizuka

Publications and source records attributed to K Torizuka.

At least 343 records · Page 19Linked to original sources

Analysis of 99mTc-pyridoxylidene-glutamate complex formation and its preparation with tin-adsorbed-resin: Sn-Resin kit method.

99mTc-Pyridoxylidene-glutamate (Tc-PG) was introduced in 1975 by Baker et al. as a cholescintigraphic agent. Nevertheless its routine use has been limited due to the autoclaving process involved. To shorten the labeling procedure, an analysis of Tc-PG complex formation using the stannous chloride method was carried out. Sn-Resin (stannous ion adsorbed onto cation exchange resin) was used for labeling a stable Tc-PG with high efficiency. A preautoclaved complex of pyridoxal and glutamate was required but the labeling procedure took only 10-15 min after the elution of 99m-TcO4- from the generator. Formation of a complex other than a 99mTc-complex of the Schiff -base ligand pyridoxylidene-glutamate is discussed. The new formulation of a Tc-PG kit (Sn-Resin) simplified the labeling method and reproducible data to that already reported by Baker was obtained in chromatographic studies. Its suitability in hospital departments has already been shown in clinical studies.

Bile↗

Technetium coordination state as a factor of stability in 99mTc-complexes used in hepatobiliary system: comparative studies on 99mTc-complexes of pyridoxal with glutamate (Tc-PG) and isoleucine (Tc-PI).

Studies on 99mTc-Penicillamine (Tc-Pen) have given us some insight into the significance of the technetium coordination state in hepatobiliary clearance behavior. A 99mTc-complex of pyridoxal and glutamate (Tc-PG) prepared by Baker et al. (1975) using an autoclaving process or by a Sn-Resin kit method (Horiuchi 1981) was compared with a 99mTc-complex of pyridoxal and isoleucine (Tc-PI) prepared by the method of Kato and Hazue (1978) through an intermediate compound of stannous ion, at room temperature. Tc-PG and TcPI complexes analyzed by thin layer chromatography, sephadex column chromatography (G-15), octanol extraction, and ligand exchange reaction showed different chemical properties. Their biological evaluation also demonstrated great differences in biodistribution in mice, metabolic studies, protein binding, and rat bile excretion. Tc-PG was estimated as an hepatobiliary agent with strong metal-ligand binding, inert to ligand exchange reaction with Pen at physiological pH; the likely occurrence of technetium in a mononuclear or dinuclear state providing the great stability observed in its biological and in vivo behavior was compared with the relatively weaker binding observed in Tc-PI, a highly lipophilic complex of high liver partition but of low stability, denoting its different chemical characteristics. The technetium coordination state in radiopharmaceuticals is responsible for the integrity of the molecule while in the blood pool and its relevance in impaired liver uptake is discussed.

Animals↗

Clinical evaluation of serum ferritin to iron ratio in malignant diseases.

Serum ferritin levels were measured in 72 normal subjects and in 214 cases with various diseases by an immunoradiometric assay. In normal subjects, the serum ferritin levels were 27-230 mg/ml. Elevated serum ferritins were observed in most cases with iron excess and acute hepatitis. Markedly elevated levels were found in the majority of cases with acute leukemia, malignant lymphoma, hepatoma, and pancreatic cancer. High ferritin levels were also found in other malignant diseases. However, the range overlapped broadly with that of nonmalignant diseases. The serum ferritin correlated significantly with serum iron in normals and in those with iron deficiency anemia. In most nonmalignant cases, the serum ferritin and iron levels distributed on a regression line obtained from levels in normals and those with iron deficiency anemia. However, 92% of the malignant cases showed a serum ferritin to iron ratio higher than that of normal subjects. The estimation of the serum ferritin to iron ratio is a useful means for screening patients or in the differential diagnosis of a suspected malignant lesion.

Adult↗

Adenylate cyclase activation and competitive binding with renal tissue using synthetic eel calcitonin analog and its fragments.

The structure-function relationship of calcitonin (CT) was investigated using a synthetic eel CT (E-CT) analog and its fragments. Adenylate cyclase activation and competitive binding to rat renal receptors were used as parameters of function. [Asu1,7]E-CT analog, synthesized by replacing the S-S bond of Cys1-Cys7 in the natural hormone with ethylene linkage of 1-amino suberic acid (Asu), and E-CT fragment 11-32 had about 1/5th and 1/50th the potencies of synthetic E-CT, respectively, in both adenylate cyclase activation and competitive inhibition of 125I-labeled [Asu1,7]iodo-E-CT binding on rat renal plasma membranes. The minimal chain length required to activate adenylate cyclase in rat renal plasma membranes was between 12-18 amino acids, and the minimal chain length required to affect the CT receptor binding was between 6-12 amino acids, near the C-terminus. Fragments, including the C-terminus, show a disproportionate and potent inhibition of the binding compared with the potency required for adenylate cyclase activation. Thus, the amino acid sequence near the C-terminus probably plays an important role in the binding of CT to the receptor. (Endocrinology 108: 698, 1981.)

Adenylyl Cyclases↗

Characterization of triton-solubilized TSH receptors from human thyroid plasma membranes.

The TSH receptor from human thyroid plasma membranes has been solubilized in 10 mM Tris/HCl, 50 mM NaCl, pH 7.4 containing 0.5% triton X-100. Binding of [125I]TSH to the soluble receptor showed rapid and reversible kinetics and reached a maximum within 30 min at 37 degrees C, by 1 h at 25 degrees C and by 24 h 4 degrees C. Optimal pH was 7.4. The soluble receptor retained specificity with cross-reactivity only to crude hCG (0.03%). Scatchard plots were curvilinear indicating the presence of at least two binding sites. The high affinity site showed an affinity content of 1.1 X 10(9) M-1 with binding capacity of 1.3 X 10(-10) M/mg protein. TSH-binding inhibitor immunoglobulins from patients with Graves' disease inhibited [125I]TSH binding to the soluble receptor in a dose-dependent manner. NaCl inhibited the TSh binding and this was ascribed to the decrease in the receptor capacity. Trypsin, neuraminidase and phospholipase C treatment of the solubilized receptor had no effect on TSH binding. The apparent molecular weight of the receptor, determined by gel filtration of Sepharose 6B, was approximately 300 000.

Cell Membrane↗

Determination of the pleural edge by gamma-ray transmission computed tomography.

A technique is described for transaxial imaging of the thorax during pulmonary perfusion study. The contours of the air-containing lungs were obtained by gamma-ray transmission data from a Tc-99m plane flood source. These images were overlaid on the emission tomogram of the pulmonary blood flow obtained with Tc-99m MAA. It permits reliable detection of peripheral perfusion defects. Use of the results from these measurements can be applied to evaluate marginal hypoperfusions of the lungs.

Adult↗

Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography.

Single-photon emission computed tomography (SPECT) for thallium-201 myocardial imaging with a rotating gamma camera was evaluated in comparison with planar imaging and seven-pinhole tomography (7P). Cardiac phantom studies indicated that defects 2 cm in diameter can be visualized by both tomographic methods, but the 7P method showed propagation of the image into nearby planes, with lower image contrast. In a clinical study of 47 patients with myocardial infarction, both sensitivity and specificity for the SPECT system were high (96 and 89%, respectively); the 7P system, on the other hand, showed good sensitivity (93%) but poor specificity (68%), while planar imaging performed conversely (75 against 89%). The overall accuracy was not significantly improved in the 7P method (planar: 81%, 7P: 83%, and SPECT: 94%). Our study indicates that SPECT, which can reconstruct reliable tomographic sections in either the transaxial, frontal, or sagittal planes, will result in a remarkable improvement in the clinical evaluation of ischemic heart disease.

Adolescent↗