Search PubMed⌕ Search

Biomedical subjects

K Tiesenhausen

Publications and source records attributed to K Tiesenhausen.

28 records · Page 2Linked to original sources

[Primary bacterial infection of an artery].

INTRODUCTION: Primary bacterial infection of an artery is difficult to diagnose, especially at the beginning of the illness. Most of the patients come for emergency treatment in the phase of rupture. METHODS: The course of illness in four patients serves as background for discussion of the problems of diagnosis and therapy. RESULTS: Bacterial infection of arteries shows a high rate of complications and, for the aorta, high mortality. CONCLUSION: If fever of uncertain origin is combined with pain of the stomach or of the back, or with a painful reddish swelling on a limb, this rare disease should be considered in the differential diagnosis.

Aged↗

[Posttraumatic aneurysm of the brachiocephalic trunk: a rare injury].

We report on a posttraumatic aneurysm of the brachiocephalic trunk, something which is rather rare. The injury was caused by blunt chest trauma following a car accident. Computed tomography could not find the brachiocephalic lesion. In patients with fractures of the upper ribs after blunt chest trauma, angiography should be done to exclude severe injuries of the aorta and brachiocephalic vessels.

Adult↗

Aortoduodenal fistula: a late complication of intraluminal exclusion of an infrarenal aortic aneurysm.

During recent years, considerable clinical experience has been gained with endoluminal stent-graft procedures. Several studies have shown promising results up to a period of 4.5 years. However, long-term follow-up studies are still limited. Late endoleaks caused by stent-graft migration, disconnection of single components in modular stent-grafts, and limb thrombosis have been observed as long-term complications. We report a case in which a migrated and kinked bifurcated stent-graft caused an aortoduodenal fistula 20 months after stent-graft insertion. To our knowledge, such a complication has not been reported before.

Aorta, Abdominal↗

Aplasia of the vena cava inferior as a cause for recurring thrombosis of the lower extremities and pelvic veins.

Congenital anomalies of the caval vein are often associated with other abnormalities such as heart defects, situs inversus or a polysplenia-asplenia-syndrome. An isolated, congenital malformation like aplasia of the inferior vena cava is a rare finding. A review of the embryology and abnormalities, diagnostics, clinical signs and treatment is given together with the histories of two patients having thrombosis of the lower extremities and pelvic veins, caused by aplasia of the inferior vena cava. After thrombotic complications caused by vena cava aplasia there is high risk of recurrence. Those patients should be anticoagulated for lifetime.

Adult↗

[Endoluminal therapy of infrarenal aortic aneurysms with the Talent system--initial experiences with a new endoprosthesis].

PURPOSE: To report the early clinical experience with the Talent stent-graft system in the treatment of infrarenal aortic aneurysms. MATERIALS AND METHODS: The study group comprised 15 males aged from 51-79 years. A bifurcated Talent stent-graft was implanted in 9 patients with type B or C aneurysms, a tube graft in 6 patients with a type A aneurysm. The stent-grafts were introduced via a surgical femoral cut-down, for a bifurcated graft a bilateral surgical access was needed. All procedures were performed as teamwork by radiologists and vascular surgeons under general anaesthesia in the angiography suite. RESULTS: Primary and secondary technical successes were 80 and 86%, respectively. Technical failures were due to access site problems (n = 1; elective open repair), malpositioning of the prosthesis (n = 1; immediate conversion to open surgery), and primary distal leakage (n = 1; elective occlusion by means of distal stent-graft extension). One patient died 15 days after an uneventful stent-graft insertion (30-day mortality 6%). No complications were observed during a mean follow-up period of 7.8 months. The aneurysmal diameter decreased in 6 patients and remained unchanged in the others. CONCLUSIONS: The Talent system revealed satisfactory early results which are comparable to competitive stent-graft systems. An advantage of this stent-graft device is the availability in a wide range of dimensions. A major disadvantage is the large introducer system (french size 22-27).

Aged↗

Treatment of acute aortic type B dissection with stent-grafts.

PURPOSE: To evaluate the feasibility of endoluminal stent-grafts in the treatment of acute type B aortic dissections. METHODS: In five patients with acute aortic type B dissections, sealing of the primary intimal tear with an endoluminal stent-graft was attempted. Indication for treatment was aneurysm formation in two patients and persistent pain in three patients. One of the latter also had an unstable dissection flap compromising the ostium of the superior mesenteric artery. The distance from the intimal tear to the left subclavian artery was <0.5 cm in four patients, who had typical type B dissections. In one patient with an atypical dissection the distance from the primary tear to the left subclavian artery was 4 cm. This patient had no re-entry tear. Talent tube grafts (World Medical Manufacturing Cooperation, Sunrise, FL, USA) were used in all patients. RESULTS: Stent-graft insertion with sealing of the primary tear was successful in all patients. The proximal covered portion of the stent-graft was placed across the left subclavian artery in four patients (1x transposition of the left subclavian artery). Left arm perfusion was preserved via a subclavian steal phenomenon in the patients in whom the stent-graft covered the orifice of the left subclavian artery. The only procedural complication we observed was an asymptomatic segmental renal infarction in one patient. In the thoracic aorta thrombosis of the false aortic lumen occurred in all patients. In one patient the false lumen of the abdominal aorta thrombosed after 4 weeks; in the other three patients the status of the abdominal aorta remained unchanged compared with the situation prior to stent-graft insertion. As a late complication formation of a secondary aneurysm of the thoracic aorta was observed at the distal end of the stent-graft 3 months after the primary intervention. This aneurysm was treated by coaxial insertion of an additional stent-graft without complications. CONCLUSION: Endoluminal treatment of acute type B aortic dissections seems to be an attractive alternative treatment to surgical repair. Thrombosis of the false lumen of the thoracic aorta can be induced if the primary tear is sealed with a stent-graft. This could protect the dissected thoracic aorta from delayed rupture.

Acute Disease↗

Endovascular treatment of proximal anastomotic aneurysms after aortic prosthetic reconstruction.

PURPOSE: To describe the efficacy and value of endovascular stent-grafts for the treatment of aortic anastomotic pseudoaneurysms. METHODS: Three patients with proximal aortic anastomotic pseudoaneurysms 8--15 years after prosthetic reconstruction were treated by transfemoral stent-graft implantation. In two patients the pseudoaneurysms were excluded by Talent prostheses [tube graft (n = 1), bifurcated graft (n = 1)]. In one patient an uniiliac Zenith stent-graft was implanted and an extra-anatomic crossover bypass for revascularization of the contralateral lower extremity was performed. RESULTS: All procedures were successful with primary exclusion of the pseudoaneurysms. During the follow-up (mean 16 months) one endoleak occurred due to migration of the tube stent-graft. The endoleak was sealed successfully by implanting an additional bifurcated stent-graft. CONCLUSION: Stent-graft exclusion of aortic pseudoaneurysms offers a minimally invasive and safe alternative to open surgical reconstruction.

Aged↗

[Arterial complications caused by using an axillary crutch].

BACKGROUND: Of all upper extremity emboli, up to twenty percent arise from an arterial, not a cardiac source. METHOD: We report about a patient with recurrent embolism, caused by an axillary crutch-induced aneurysm of the axillary artery. RESULT: After revascularisation by embolectomy and axillo-brachial vein graft bypass, the patient was free of symptoms. CONCLUSION: Angiography and duplex scanning were necessary for the correct diagnosis.

Aged↗

Helical CT angiography of stent-grafts in abdominal aortic aneurysms: morphologic changes and complications.

Transfemoral placement of an endovascular stent-graft is increasingly be-ing used as an alternative to surgical repair in the treatment of abdominal aortic aneurysm, especially in high-risk patients. However, complications frequently occur after stent-graft placement. Helical computed tomographic (CT) angiography is a fast, minimally invasive procedure that is quickly becoming the imaging modality of choice for assessment of these complications. Thirty-nine patients who were treated for abdominal aortic aneurysm with stent-graft placement underwent helical CT angiography at routinely scheduled follow-up intervals or whenever complications were suspected. The resulting images were evaluated for the presence, extent, and origin of endovascular leaks. In addition, the position, shape, and patency of the stent-grafts were assessed. Findings included both graft-related (n = 4) and non-graft-related (n = 3) leaks, thrombosis of a graft limb (n = 3), distal migration of the stent-graft (n = 5), angulation of bifurcated stent-grafts distal to the main graft (n = 6), shrinkage of the abdominal aortic aneurysm (n = 7), enlargement of the aneurysm with secondary graft-related leaks (n = 2), and an aortoduodenal fistula (n = 1). Helical CT angiography can depict complications that develop after treatment of abdominal aortic aneurysms with endovascular stent-grafts. Long-term follow-up is required to determine the full spectrum and frequency of complications that may develop after initially successful repair.

Aged↗

Results and complications in endovascular treatment of abdominal aortic aneurysms--a single center experience.

Between September 1996 and February 2000 five female and 62 male patients with an abdominal aortic aneurysm, requiring therapy, underwent endoluminal treatment. Their age ranged from 51 to 81 years (mean 72 years). Preoperative evaluation was done with spiral computed tomography (CT) and angiography. All procedures were performed under general anesthesia in a radiologically adapted operating room. Postoperative complications occurred in 28.4%. The total conversion rate was 13.4%, the 30-day lethality rate was 1.4%. During the mean follow-up of 15.1 months 19 secondary interventions were necessary in 13 patients. The results presented in this study do not justify the wide use of this method and indicate a stricter form of patient selection.

Aged↗