Search PubMed⌕ Search

Biomedical subjects

K Tamasaku

Publications and source records attributed to K Tamasaku.

15 recordsLinked to original sources

Evidence for suppressed screening on the surface of high temperature La(2-x)SrxCuO4 and Nd2(2-x)CexCuO4 superconductors.

Hard x-ray photoemission spectroscopy (PES) of Cu core electronic states, with a probing depth of approximately 60 A, is used to show that the Zhang-Rice singlet feature is present in La2CuO4 but is absent in Nd2CuO4. Hole and electron doping in La(2-x)SrxCuO4 (LSCO) and Nd(2-x)CexCuO4 (NCCO) result in new well-screened features which are missing in soft x-ray PES. Impurity Anderson model calculations establish screening from doped states as its origin, which is strongly suppressed within 15 A of the surface. Complemented with x-ray absorption spectroscopy, the small chemical-potential shift in core levels (approximately 0.2 eV) are shown to be consistent with modifications of valence and conduction band states spanning the band gap (approximately 1 eV) upon hole and electron doping in LSCO and NCCO.

Journal Article↗

Nature of the well screened state in hard X-ray Mn 2p core-level photoemission measurements of La1-xSrxMnO3 films.

Using hard x-ray (HX; hnu=5.95 keV) synchrotron photoemission spectroscopy (PES), we study the intrinsic electronic structure of La(1-x)Sr(x)MnO(3) (LSMO) thin films. Comparison of Mn 2p core-levels with soft x-ray (SX; hnu approximately 1000 eV) PES shows a clear additional well-screened feature only in HX PES. Takeoff-angle dependent data indicate its bulk (> or =20 A) character. The doping and temperature dependence track the ferromagnetism and metallicity of the LSMO series. Cluster model calculations including charge transfer from doping-induced states show good agreement, confirming this picture of bulk properties reflected in Mn 2p core-levels using HX PES.

Journal Article↗

Deterministic retrieval of surface waviness by means of topography with coherent X-rays.

A surface profile retrieval technique from multiple X-ray total reflection images taken at various distances with full coherent illumination is demonstrated. An experiment was performed using the 1 km-long BL29XU beamline at the SPring-8 facility, Japan. Obtained results are compared with results from the optical metrology technique (Fizeau's interferometer). Good agreement between X-ray and optical methods proves the validity of the current approach. Meanwhile, the sensitivity of the X-ray technique is several times higher than that of the standard one. This technique is well suited to the needs of characterizing grazing optics for new-generation X-ray sources.

Journal Article↗

Measurement of x-ray pulse widths by intensity interferometry.

The pulse width of hard undulator radiation (32 ps width, energy 14 keV) was determined by intensity interferometry. The method, in combination with various x-ray monochromators, enables measurements to be taken over a wide range of time frames, from ns to fs. The applicable target includes measurements of ultrafast x-ray pulse widths from fourth generation synchrotron light sources.

Calibration↗

X-ray interferometry with multicrystal components using intensity correlation.

A theoretical relation between intensity correlation and interference was experimentally verified for the case of a large-separation skew-symmetric bicrystal interferometer. The intensity correlation was enhanced in the angular range where the interference fringes were clearly observed. An application investigating the interference condition of the interferometer is presented using the intensity-correlation technique.

Journal Article↗

Position of exit X-rays from rotated-inclined double-crystal monochromators.

The rotated-inclined double-crystal monochromator (RIDCM) has been adopted to reduce the heat load from third-generation undulator radiation. The position of the exit X-rays from RIDCM has been calculated as a function of X-ray energy on the basis of diffraction theory including refraction effects. The results show that the positions of the exit X-rays vary over a wide range due to asymmetric reflection. Methods of fixing the exit position in RIDCM are also discussed.

Journal Article↗

SPring-8 beamline control system.

The SPring-8 beamline control system is now taking part in the control of the insertion device (ID), front end, beam transportation channel and all interlock systems of the beamline: it will supply a highly standardized environment of apparatus control for collaborative researchers. In particular, ID operation is very important in a third-generation synchrotron light source facility. It is also very important to consider the security system because the ID is part of the storage ring and is therefore governed by the synchrotron ring control system. The progress of computer networking systems and the technology of security control require the development of a highly flexible control system. An interlock system that is independent of the control system has increased the reliability. For the beamline control system the so-called standard model concept has been adopted. VME-bus (VME) is used as the front-end control system and a UNIX workstation as the operator console. CPU boards of the VME-bus are RISC processor-based board computers operated by a LynxOS-based HP-RT real-time operating system. The workstation and the VME are linked to each other by a network, and form the distributed system. The HP 9000/700 series with HP-UX and the HP 9000/743rt series with HP-RT are used. All the controllable apparatus may be operated from any workstation.

Journal Article↗