Search PubMed⌕ Search

Biomedical subjects

K Sunagawa

Publications and source records attributed to K Sunagawa.

At least 145 records · Page 8Linked to original sources

Effects of arterial input impedance on mean ventricular pressure-flow relation.

The mean left ventricular pressure-flow relationship (Pv-Fv), determined under a constant preload and variable peripheral resistance, has been proposed as a quantitative representation of ventricular pump function (9). We determined the Pv-Fv relation in seven isolated cross-perfused canine hearts by varying resistance of a simulated arterial load in five steps from 6.0 to 0.375 mmHg X s X ml-1 while keeping end-diastolic volume, inotropic state, compliance, and characteristic impedance at various constant values. All of the 27 Pv-Fv relations thus determined were moderately nonlinear. Varying end-diastolic volume at three levels shifted the relation curve in an approximately parallel fashion (P less than 0.0001). At three levels of inotropic state (mean LVP of isovolumic contractions 34.3 +/- 8.2, 48.0 +/- 6.3, and 59.2 +/- 9.6 mmHg), the Pv-Fv relation shifted with predominantly a slope change (P less than 0.0001). Changing compliance at three levels (0.2, 0.4, and 0.8 ml/mmHg) caused a statistically significant but quantitatively small crossover of the Pv-Fv curves (P less than 0.0001). Changing characteristic impedance to 0.1, 0.2, and 0.4 mmHg X s X ml-1 caused a highly significant (P less than 0.0001) divergence of Pv-Fv relation over the high Fv range. We conclude that this sensitivity of the Pv-Fv relation to characteristic impedance limits its use as a contractility index.

Animals↗

The use of left ventricular end-ejection pressure and peak pressure in the estimation of the end-systolic pressure-volume relationship.

The end-systolic pressure-volume relationship (ESPVR) as derived from left ventricular pressure-volume loops has gained increasing acceptance as an index of ventricular contractile function. In animal experiments the ESPVR has been defined as a line connecting the upper left corners of several differently loaded pressure-volume (P-V) loops with a slope parameter Ees and a volume axis intercept parameter Vo. In the clinical setting, several variants of the ESPVR have been determined with use of peak left ventricular pressure, end-ejection pressure, and end-ejection volume. The maximum P-V ratio has also frequently been measured. We attempted to determine which of these alternatives resulted in good approximations of the reference ESPVR in eight isolated canine ventricles that ejected into a simulated arterial impedance system with resistance, compliance, and characteristic impedance. We determined various versions of the ESPVR from the same set of beats quickly obtained with little change in inotropic background. To vary ventricular pressure wave forms, each of the arterial impedance parameters was independently controlled at 50%, 100%, and 200% of normal. Against each of the nine combinations of the impedance parameters four P-V loops were obtained under four preloads and from each of the sets of four P-V loops, the reference ESPVR, linear regression of the peak pressure on end-ejection volume (ESPVRPP-EEV), and linear regression of end-ejection pressure on end-ejection volume (ESPVREEPV) were determined. In addition, the maximum P-V ratio (MPVR) was calculated for each P-V loop.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Quantitative comparison of the force-interval relationships of the canine right and left ventricles.

We quantitatively compared the extrasystolic and postextrasystolic responses of the right ventricle and left ventricle of the same heart, which have vastly different geometries, architectures, and muscle masses. We studied nine isolated, supported canine hearts whose right and left ventricles were made to contract isovolumically with balloons placed in both chambers. The ventricles were paced with the following pattern: 20 regularly timed priming stimulations, followed by a test stimulation at a variable test pulse interval, and, finally, by a second test stimulation which was always delivered 1200 msec after the first test pulse. In each heart, approximately 15 different test pulse intervals between 300 and 1200 msec were investigated. Both the maximum developed pressure and maximum rate of pressure development, expressed as a percentage of their steady state values during the priming period were used to quantify the extra- and postextrasystolic responses. For each extrasystolic and postextrasystolic test beat, the normalized response of the right ventricle was plotted vs. that of the left ventricle. The regression line and correlation coefficient between the two were determined. The average result from nine hearts gave a slope of 0.96 +/- 0.05, an intercept of 4.52 +/- 4.05% and a correlation coefficient of 0.995 +/- 0.004. This analysis indicated that, despite the differences in right and left ventricular geometry, architecture, and mass, their force-interval behaviors were nearly identical.

Animals↗

Effect of arterial impedance changes on the end-systolic pressure-volume relation.

To study the end-systolic pressure-volume relationship of left ventricle ejection against physiological afterload, we imposed seven simulated arterial impedances on excised canine left ventricles connected to a newly developed servo-pump system. We set each of the impedance parameters (resistance, capacitance, and characteristic impedance) to 50, 100, and 200% of normal value (resistance: 3 mm Hg sec/ml; capacitance: 0.4 ml/mm Hg; characteristic impedance: 0.2 mm Hg sec/ml), while leaving the other parameters normal. Under a given impedance, the end-systolic pressure-volume relationship was determined by preloading the ventricle at four different end-diastolic volumes. There was no significant change in the slope of the end-systolic pressure-volume relationship with changes in any of the afterloading impedance parameters. However, the volume intercept of the end-systolic pressure-volume relationship decreased significantly with resistance from 5.5 +/- 1.0 (SE) ml at resistance equal to 1.5 mm Hg sec/ml to 0.6 +/- 1.8 ml at resistance equal to 6 mm Hg sec/ml (P less than 0.01). The volume axis intercept also decreased with characteristic impedance, from 5.9 +/- 2.0 ml at a characteristic impedance of 0.1 mm Hg sec/ml to 5.4 +/- 2.1 ml at a characteristic impedance of 0.4 mm Hg sec/ml, (P less than 0.05). We conclude that the slope of the end-systolic pressure-volume relationship is insensitive to a wide range of changes in afterload impedance, but its volume intercept is dependent on resistance and characteristic impedance.

Animals↗

Factors affecting the end-systolic pressure-volume relationship.

The end-systolic pressure-volume relationship (ESPVR) defines the systolic limits of cardiac performance. Using an isolated cross-circulated canine heart preparation, we examined the influence of afterload impedance changes, changes in coronary artery pressure (CAP), and regional ischemia on the ESPVR. We found that afterload impedance did not change the slope of the ESPVR but that increases in resistance and characteristic impedance did shift the relation slightly to the left. There was no change in the ESPVR with changes in CAP above a certain critical value. A decrease in CAP below this value caused a progressive decline in the slope of the ESPVR. With regional ischemia the ESPVR became nonlinear, and there was a near parallel downward shift of the ESPVR in the high-volume range. This shift was directly proportional to the extent of ischemic area. We conclude that an adequate measurement of the ESPVR demands at least three pressure-volume points to check for linearity and characterization of both the slope and volume intercept.

Animals↗

Evaluation of pulse contour methods in calculating stroke volume from pulmonary artery pressure curve (comparison with aortic pressure curve).

The reliability of five equations in assessing stroke volume from pulmonary artery pressure curves were critically evaluated in six dogs and in six patients. To alter stroke volume, isoproterenol, dobutamine, propranolol, lactate Ringer solution and artificial pacing were employed in the animal study and diltiazem (a calcium blocker) in the human study. A good correlation was found between the calculated and measured stroke volume (r = 0.80-0.86 in the animal study and r = 0.94-0.96 in the human study). The assessment of stroke volume from the pulmonary arterial pressure curves using equations was as good as that from the aortic pressure curves calculated simultaneously. These results suggest that the five equations may be clinically applicable for assessing stroke volume in critically ill patients. The employment of pulmonary arterial pressure curves in assessing stroke volume may be more useful clinically since its recording can be carried out more safely than recordings of aortic pressure curves.

Animals↗

Left ventricular interaction with arterial load studied in isolated canine ventricle.

We developed a framework of analysis to predict the stroke volume (SV) resulting from the complex mechanical interaction between the ventricle and its arterial system. In this analysis, we characterized both the left ventricle and the arterial system by their end systolic pressure (Ps)-SV relationships and predicted SV from the intersection of the two relationship lines. The final output of the analysis was a formula that gives the SV for a given preload as a function of the ventricular properties (Ees, V0, and ejection time) and the arterial impedance properties (modeled in terms of a 3-element Windkessel). To test the validity of this framework for analyzing the ventriculoarterial interaction, we first determined the ventricular properties under a specific set of control arterial impedance conditions. With the ventricular properties thus obtained, we used the analytical formula to predict SVs under various combinations of noncontrol arterial impedance conditions and four preloads. The predicted SVs were compared with those measured while actually imposing the identical set of arterial impedance conditions and preload in eight isolated canine ventricles. The predicted SV was highly correlated (P less than 0.0001) with the measured one in all ventricles. The average correlation coefficient was 0.985 +/- 0.004 (SE), the slope 1.00 +/- 0.04, and the gamma-axis intercept 1.0 +/- 0.2 ml, indicating the accuracy of the prediction. We conclude that the representations of ventricle and arterial system by their Ps-SV relationships are useful in understanding how these two systems determine SV when they are coupled and interact.

Animals↗

Effect of regional ischemia on the left ventricular end-systolic pressure-volume relationship of isolated canine hearts.

We studied the effects of regional ischemia on the left ventricular isovolumic end-systolic pressure-volume relationship (ESPVR) in six excised, blood-perfused canine ventricles. We created different extents of regional ischemia by ligating various branches of the coronary arteries while keeping the coronary arterial pressure constant (80 mm Hg). The extent of regional ischemia (Rm) relative to the total mass of the left ventricular myocardium was determined by regional myocardial blood flow measured by the radioactive microsphere technique. With regional ischemia, the ESPVR shifted rightward without significant change in slope in the physiologic end-systolic pressure range. In the subphysiological end-systolic pressure range, however, its slope became lower than control. In order to quantify the degree of the rightward shift, we measured the extrapolated volume axis intercept (Vo) by fitting a straight line to the ESPVR in the physiological range under control and ischemic conditions. The shift in Vo (delta Vo) associated with ischemia was linearly correlated with Rm (delta Vo = 50.7Rm-0.6, n = 28, r = 0.944, P less than 0.001). We conclude that the major effect of acute regional ischemia on the ESPVR in the physiological pressure range is a parallel rightward shift. This forms a striking contrast to the effect of global ischemia (under which only the slope is affected without a substantial change in Vo).

Animals↗

[Experimental and clinical studies of an ampicillin suppository (KS-R1) in pediatrics].

Blood levels of ampicillin (ABPC) were measured in 10 childish patients with heart disease after the rectal administration of KS-R1 at doses of 125 mg and 250 mg. Average blood levels of ABPC at 15, 30 minutes, 1, 2 hours and 4 hours after the administration of KS-R1 were 6.8, 6.9, 3.1, 1.1 mcg/ml and 0.1 mcg/ml with half-life of 0.64 hours in patients of age from 1 year to 4 years 7 months old (dose level 8.9 approximately 13.9 mg/kg, average 10.5 mg/kg), and 5.2, 6.1, 3.4, 1.0 mcg/ml and 0.1 mcg/ml with half-life of 0.65 hours in patients of age from 7 years 10 months to 10 years 7 months old (dose level 8.3 approximately 13.9 mg/kg, average 9.8 mg/kg), respectively. Clinical effective rate (excellent and good) was 87% in 55 childish patients with infections. Bacteriologically, 13 strains (74%) out of 18 strains which were isolated from the patients were eradicated. No severe side effects were observed. Diarrhea was observed in 3 cases.

Age Factors↗

Microprocessor control of a ventricular volume servo-pump.

Measurement of the instantaneous pressure-volume relationship of the left ventricle is fundamental to the study of ventricular mechanics. In order to effectively investigate this relationship, it is necessary to vary and control the time course of ventricular volume change in a variety of prescribed manners. In the past, we used an analog circuit to generate command signals for a servo-pump system which controlled ventricular volume. The use of analog control limited the variety of volume waveforms which could be generated. To overcome this limitation, we developed a new system in which the servo-pump is controlled by an inexpensive microprocessor based computer, capable of generating an unlimited repertoire of volume waveforms. The computer system also made possible the use of adaptive control to increase the system fidelity. Finally, such a system provides for ease of adjustment to new hardware, should future research require it.

Animals↗

Impedance loading servo pump system for excised canine ventricle.

To investigate ventricular-arterial system interaction, we have developed a hybrid-computer-controlled impedance loading servo pump system that enables us to impose a simulated arterial hydraulic impedance on an excised canine ventricle. An analog computer programmed to simulate a three-element Windkessel model of the arterial system computes instantaneous aortic flow from the instantaneous ventricular pressure. The time integral of this flow is used to command a volume servo pump system that controls the instantaneous ventricular volume. All parameter values in the loading system are controlled by a digital computer. The actual impedance spectrum generated by the system was reasonably close to that expected from the arterial model. The unique features of this system are the following. 1) The instantaneous volume of the ventricle, which is crucial information, can be measured. 2) If needed, the arterial impedance model can easily be reprogrammed to generate more complex impedance spectra. 3) The vascular parameters can be made nonlinear or time varying through the digital computer control.

Animals↗

Effects of coronary arterial pressure on left ventricular end-systolic pressure-volume relation of isolated canine heart.

In the excised canine left ventricle, the end-systolic pressure-volume relationship (ESPVR) has been shown to be approximately linear over the working range of loading conditions when coronary arterial pressure (CAP) is maintained constant, independent of loading conditions. To investigate the ESPVR under the more intact physiological condition in which the CAP varies with loading on the left ventricle, we studied the effect of changes in CAP on the ESPVR in 10 excised cross-circulated canine ventricles which were contracting isovolumically. The ESPVR, determined from isovolumic contractions at four different volumes, was reasonably independent of CAP as long as CAP remained above a critical pressure (67.0 +/- 22.1 mm Hg). Below this pressure, the slope of ESPVR decreased although the volume axis intercept (V0) remained unaltered. These findings indicate that under physiological conditions, where there is a close coupling of CAP to systolic left ventricular pressure, the ESPVR should become nonlinear in the low preload or afterload regions. When CAP was varied with the left ventricular pressure in five ventricles, the ESPVR indeed became nonlinear in the low-load region. We conclude that the ESPVR in intact conditions is reasonably linear in the physiological load range, but it can be nonlinear in the low-load range.

Animals↗

[The experimental and clinical studies on cefsulodin in the pediatric field].

A new cephalosporin cefsulodin (CFS) was studied basically and clinically and the following results were obtained. 1. The serum levels of 25 mg/kg of CFS administered intravenously were 39.5 mcg/ml after 30 minutes, 22.6 mcg/ml after 1 hour, 11.6 mcg/ml after 2 hours, 6.0 mcg/ml after 4 hours and 2.1 mcg/ml after 6 hours. The half life from serum was 84 minutes. 2. Clinical response on 4 cases of Pseudomonas aeruginosa infections were all good. 3. The slight elevations of GOT, GPT were observed by the drug administrations in 1 case. From the above results, CFS was effective drug to P. aeruginosa infections by intravenous administration of 25 mg/kg of CFS.

Age Factors↗

Left atrial ball thrombus diagnosed by two-dimensional echocardiography.

The diagnosis of the ball thrombus in the left atrium has been very difficult by conventional clinical techniques. In the present case, two-dimensional echocardiography successfully demonstrated a spherical tumor moving in unpredictable directions in the left atrium. M-mode echocardiography did not clearly identify the tumor because of the limited visual width and spatial orientation of the technique; however, simultaneous recordings of the M-mode echocardiogram with phonocardiogram, carotid pulse wave, and electrocardiogram provided some diagnostic clues to the occlusive left atrial tumor. In the absence mitral valve occlusion by the tumor, a logarithmic correlation between the ejection time and the preceding R-R interval, and a negative lines correlation between Q to the first sound interval and the preceding R-R interval were found. In the beat following the appearance of the tumor in the mitral orifice, the sudden shortening of the ejection time and the prolongation of Q to the first sound interval were noted. Both of these findings are indirect evidence of decreased left ventricular filling associated with an elevated left atrial pressure resulting from the sudden mitral orifice obstruction by the tumor. Detailed analysis of the data obtained by the conventional noninvasive techniques could provide critical clues for the diagnosis of the occlusive left atrial tumor.

Blood Coagulation↗

[Experience with cefuroxime in pediatric field (author's transl)].

Having resistance to beta-lactamase-producing strains and showing resistance to not only cephalosporin resistant strains of E. coli and Klebsiella but also to Citrobacter, Proteus and Enterobacter, Cefuroxime (CXM) was used in pediatric field for both fundamental and clinical studies. CXM was found to be a useful antibiotic in views of high clinical efficacy rate obtained and no side effect noted. As for the dose, the single dose of 25 mg/kg achieved sufficient blood levels. Also in view of good clinical effect, the dose of 25 mg/kg three or four times daily seems appropriate for treatment of children.

Bacterial Infections↗