Search PubMedSearch

Biomedical subjects

K Stoll

Publications and source records attributed to K Stoll.

7 recordsLinked to original sources

The use of plasma levels for FK 506 dosing in liver-grafted patients.

FK 506 plasma levels were analyzed in 89 liver-grafted patients under FK 506-based immunosuppression. Plasma levels were found to be influenced by the patients' liver function: compared to patients without major liver dysfunction, those with cholestasis had higher plasma levels and these plasma levels were able to differentiate between rejection and toxicity. In patients with stable liver function, no clear difference was observed with regard to the plasma levels detectable during toxicity or rejection. We conclude that plasma levels can be used to determine the FK 506 dose but only in patients with cholestasis (i.e., during the early post-transplant course, or in patients with cholestatic rejection). In patients with stable liver function, plasma levels are only of limited clinical relevance.

Cholestasis

Comparison of different assays for the quantitation of FK 506 levels in blood or plasma.

In a prospective study, we evaluated the analytical performance of different assays for the quantitation of FK 506 in blood and plasma. The new whole blood IMX assay was compared with four modifications (liquid/liquid or solid/liquid extraction of blood or plasma respectively) of the standard enzyme-linked immunosorbent assay (ELISA). Both assays utilize the same monoclonal antibody for detection of FK 506. Using isolated FK 506 metabolites generated in vitro, this antibody was shown to recognize not only the unmodified parent drug but also FK 506 metabolites. In stable liver-grafted patients, sensitivity of both modifications of the whole blood ELISA was adequate. In contrast, in some stable patients, plasma ELISA was not able to detect FK 506; this was observed mainly after liquid/liquid extraction of FK 506. Sensitivity of the IMX assay was also low; in six of 10 stable liver-grafted patients, IMX levels were below the limit of detection. In all assays, FK 506 levels were found to be elevated during episodes of liver dysfunction; a possible explanation for this effect would be that of accumulation of cross-reacting FK 506 metabolites. As FK 506 metabolites are known to be less immunosuppressive than the parent drug, liver function should always be taken into account if IMX or ELISA levels are used for drug monitoring.

Antibodies, Monoclonal

[Humiliation].

Explore the source record for details and available documents.

Nurse-Patient Relations