Search PubMedSearch

Biomedical subjects

K Stangl

Publications and source records attributed to K Stangl.

At least 19 recordsLinked to original sources

Fibrinogen breakdown, long-lasting systemic fibrinolysis, and procoagulant activation during alteplase double-bolus regimen in acute myocardial infarction.

Recent clinical studies comparing accelerated versus bolus administration of alteplase tissue plasminogen activator (t-PA) suggest similar thrombolytic efficacy, but reveal higher bleeding complications among older patients during the double-bolus regimen. The objective of the present study was to characterize the hemostatic profile of t-PA administered as double-bolus doses of 50 mg, at intervals of 30 minutes. Among 50 patients with acute myocardial infarction treated by double-bolus t-PA thrombolysis, coagulation and fibrinolysis parameters, as well as t-PA levels, were monitored. Monitored t-PA levels peaked at 5 and 35 minutes and were detectable within the therapeutic range even after 90 minutes. Marked systemic fibrinolytic activation was indicated by 75% depletion of both plasminogen and fibrinogen, as well as by 19-fold and 300-fold increases of fibrin degradation and fibrinogen degradation products. Plasminogen-activator inhibitor activity was completely suppressed. Pronounced procoagulant activation was reflected by a 3.4-fold increase of both factor XIIa and prothrombin fragment 1+2, and by a threefold increase of thrombin-antithrombin complex. Independent of t-PA weight dosage, fibrinolytic activation was more pronounced among older patients (> or = 63 years). We conclude that t-PA after bolus administration has a long half-life. Double-bolus regimen leads to a long-lasting systemic fibrinolytic state, which is even more remarkable among older patients--a fact that may explain the higher bleeding complications reported for this age group.

Aged

Coronary constriction and consequent cardiodepression in pulmonary embolism are mediated by pulmonary big endothelin and enhanced in early endothelial dysfunction.

OBJECTIVES: Myocardial ischemia plays a central role in the development of right ventricular failure after acute pulmonary embolism. This study investigates whether pulmonary mediators act specifically on coronary tone and cardiac contractile function in acute pulmonary microembolization and whether such effects are altered in the case of early systemic atherosclerosis. We employ a novel model of serial perfusion in which an isolated rabbit heart is perfused with the effluent of the same animal's isolated lung. DESIGN: Controlled experiment using isolated organs. SETTING: Experimental laboratory. SUBJECTS: Male New Zealand White rabbits (controls). Age-matched, male Watanabe rabbits (hypercholesterolemic, development of accelerated atherosclerosis). INTERVENTIONS: Seven isolated control and seven isolated Watanabe hearts were perfused with the saline effluent of the same animal's isolated lung. After the assessment of the baseline data, the lungs were gradually embolized with glass beads measuring 100 microm in diameter to induce an increase in mean pulmonary arterial pressure from 6 to 8 mm Hg, at baseline, up to 25 mm Hg. MEASUREMENTS AND MAIN RESULTS: Pulmonary embolization to 25 mm Hg evoked a coronary constriction, measured as coronary flow decrease to 89 +/- 7% of the baseline value in controls. In the Watanabe group, coronary constriction was significantly enhanced, compared with controls, with coronary flow decreasing to 76 +/- 6% of the baseline value. In both groups, coronary constriction was followed by a deterioration in cardiac contractile performance. This cardiodepression was significantly deeper in Watanabe hearts with respect to both maximum ventricular pressures and maximum rates of pressure development and decline. Coronary constriction and cardiodepression were prevented by coronary infusion of the nonselective endothelin antagonist PD-145065, the endothelinA antagonists A-127722 and BQ-123, and the endothelin-converting enzyme inhibitor phosphoramidon. Concentration of big endothelin in pulmonary effluent increased from 5.6 +/- 0.3 pmol/L in controls and 5.6 +/- 0.2 pmol/L in the Watanabe group, at baseline, to 8.8 +/- 0.4 pmol/L in controls and 8.9 +/- 0.4 pmol/L in the Watanabe group, at 25 mm Hg pulmonary arterial pressure. Endothelin was not detectable at any time during the experiment in pulmonary effluent. The coronary gradient, calculated as a difference in concentration between coronary and pulmonary effluent, was negative for big endothelin and positive for endothelin in both groups. CONCLUSIONS: We have demonstrated that an increase in pulmonary release of big endothelin occurs during lung embolism, which, in turn, results in coronary constriction and consequent cardiodepression. This action of big endothelin is based on its local coronary conversion into endothelin. In addition, coronary endothelial dysfunction, attributed to early systemic atherosclerosis, was shown to represent a specific risk factor in these events.

6-Ketoprostaglandin F1 alpha

Electrogram signals recorded from acute and chronic pacemaker implantation sites in pacemaker patients.

Electrogram signals recorded from typical pacemaker implantation sites may be useful for a variety of pacemaker system functions including pacemaker follow-up, atrial and ventricular sensing (event detection), and triggered electrogram storage. We quantified the electrical characteristics of pacemaker pocket electrograms using a subcutaneous electrode array (SEA) in a population of 48 patients undergoing initial or replacement pacemaker implantation. SEA recorded intrinsic R wave amplitudes measured peak to peak averaged 118 microV and 65 microV for the two recorded SEA electrograms and were significantly different (P < 0.001); paced R wave amplitudes averaged 180 microV and 110 microV. P wave amplitudes averaged 39 microV and 26 microV. No statistically significant difference in amplitudes were observed between acute versus chronic pacemaker pocket or indication for pacing (AV block, sick sinus syndrome). Signal to noise ratios, using R wave amplitude as signal, were lower in the SEA electrogram on average (11 dB) compared to the intracardiac electrogram (27 dB), but sufficient for diagnostic assessment. R wave/P wave ratios for SEA signals were lower than surface and intracardiac values 3.1 and 2.7 compared to a range of 6.2-9.8, indicating a relative enhancement of P waves to R waves in SEA signals. In summary, SEA electrograms are of sufficient amplitude and signal quality (signal to noise ratio) to hold promise for future implantable device features such as electrogram telemetry, enhanced sensing, and diagnostic data storage.

Adult

Pulmonary big endothelin affects coronary tone and leads to enhanced, ET(A)-mediated coronary constriction in early endothelial dysfunction.

BACKGROUND: Lung tissue produces a variety of mediators; however, little is known regarding how these mediators affect coronary regulation and myocardial contractility. In a novel rabbit lung-heart model, we investigated the possible influence exerted by pulmonary mediators on coronary tone both under normal conditions and in early endothelial dysfunction. METHODS AND RESULTS: In our model, the effluent from the isolated lung is used to serially perfuse the coronary vessels of the isolated heart of the same animal. Compared with the hearts of control rabbits, isolated hearts of Watanabe rabbits revealed pharmacological evidence of endothelial dysfunction and a significant steeper decrease of coronary flow during serial perfusion of the coronary vessels with lung effluent (75+/-6% versus 89+/-3%). This decline in coronary flow was prevented by the nonselective endothelin (ET) antagonist PD-145065, the ET(A) antagonists BQ-123 and A-127722, and the endothelin-converting enzyme inhibitor phosphoramidon. The concentration of big ET in lung effluent ranged from 5.5 to 5.8 pmol/L in both control and Watanabe groups, with levels in corresponding coronary effluent falling to 0.9 to 1.1 pmol/L in controls and to 1.0 to 1.2 pmol/L in the Watanabe group. In either group, ET was not detected in lung effluent, but it rose significantly in coronary effluent during serial perfusion. CONCLUSIONS: Pulmonary big ET, locally converted into ET during coronary passage, causes an ET(A)-mediated elevation in coronary tone under basal conditions as well as an enhanced coronary constriction when early endothelial dysfunction is present.

Acetylcholine

[Therapy of cardiogenic shock].

Cardiogenic shock is a syndrome of different etiologies resulting in the inability of the heart to provide adequate O2 delivery to peripheral organs and tissues with or without signs of severe pulmonary congestion or pulmonary edema. Clarification of the underlying etiologies is essential for prognosis and therapy. Depending on the various etiologies, the therapeutic procedure may be totally different. Furthermore, it is decisive to differentiate between an acute shock (e.g., acute myocardial infarction) and the development of a cardiogenic shock state on the basis of preexisting chronic congestive heart failure (e.g., congestive cardiomyopathy). Whenever possible the underlying disease should be treated causally (e.g., PTCA or thrombolytic therapy in AM, lysis in acute pulmonary embolism) in addition to symptomatic pharmacologic treatment with vasodilators and/or inodilators. In myogenic cardiogenic shock, the treatment with inotropic drugs (with and without vasodilatory potency) and, if necessary, in combination with additional vasodilators may be life-saving. At present, there is no alternative to catecholamines in the acute state with apparent hemodynamic instability. Catecholamines still represent the initial first line treatment. A Swan-Ganz catheter is mandatory in such situations. In view of the rapid beta 1-receptor down-regulation induced by endogenous catecholamines, long-term administration of exogenous catecholamines (adrenalin, dopamine, dobutamine), seems essentially problematic, since these compounds intensify and accelerate this process.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary

Sex hormone concentrations in men with angiographically assessed coronary artery disease--relationship to obesity and body fat distribution.

The relationship between circulating sex hormone levels and the occurrence of coronary artery disease (CAD) was studied in a group of 274 men undergoing coronary angiography. Hormone levels in men with CAD (n = 200) were compared to those in men found to be free of coronary lesions (n = 74). No significant differences were found for serum concentrations of estradiol, total testosterone, sex-hormone-binding globulin, free androgen index, dehydroepiandrosterone sulfate, or cortisol between the two groups. Serum androgens were negatively correlated to age in both groups, whereas estradiol was weakly associated with total cholesterol in the group of men without CAD. No consistent associations were detected between sex hormone levels and the degree of obesity or the distribution of body fat, the latter being assessed by the ratio of waist-to-hip circumferences. The results of this study do not support a significant role of sex steroid hormones in coronary artery disease in men.

Adult

Acute effects of beta-adrenergic stimulation with dobutamine on the plasma levels of atrial natriuretic peptide and cyclic guanosine monophosphate in patients with chronic heart failure.

In eight patients (63 +/- 7.9 years) with angiographically documented dilated cardiomyopathy, we studied the acute effects of a beta-adrenergic stimulation with dobutamine on the plasma levels of atrial natriuretic peptide (ANP) and cyclic guanosine monophosphate (cGMP). For this purpose, a four-point dose-response curve was prepared for dobutamine starting with an initial dose of 2.5 micrograms kg-1 min-1, which was increased by 2.5 micrograms kg-1 min-1 at a time up to altogether 10 micrograms kg-1 min-1. Each stage lasted 15 min. ANP and cGMP were determined from the mixed venous blood before the start (t0), at 5 micrograms kg-1 min-1 after 30 min (t1), at 10 micrograms kg-1 min-1 after 60 min (t2) and after subsidence of the drug effect after 90 min (t3). ANP dropped from 380 +/- 151 pg ml-1 (normal range up to 55 pg ml-1) by 38% to 235 +/- 90 pg ml-1 after 30 min and by another 17% to 171 +/- 45 pg ml-1 after 60 min. After the effect of dobutamine had subsided, an increase by 41% to 325 +/- 139 was reached. There was a parallel drop of the mean cGMP level from 5.4 +/- 1.4 pmol.ml-1 by 28% to 3.89 +/- 1.4 pmol.ml-1 (30 min) and by another 14% to 3.2 +/- 0.7 pmol.ml-1 (60 min). After 90 min it was 18% below the initial value, being 4.4 +/- 1.3 pmol.ml-1.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

[Anti-bradycardia pacemaker therapy: rational choice of system in relation to hemodynamic and prognostic aspects].

UNLABELLED: Currently, the most important indications for pacemaker treatment include high-grade AV-block, the sinus node syndrome, atrial fibrillation with slow ventricular rate as well as the hypersensitive carotid sinus. In the Federal Republic of Germany, 88.5% of the units employed were fixed-rate ventricular single-chamber systems (VVI), in less than 10% dual-chamber systems (DDD) and in 2.4% fixed-rate atrial single-chamber systems (AAI) as well as rate-adaptive systems (VVIR, AAIR). In 1986, a total of 32,000 pacemakers were implanted in the Federal Republic and about 105,000 in the USA. State-of-the-art: Miniaturization of single-chamber systems to less than 20 grams and dual-chamber systems to less than 30 grams has been associated with markedly improved lead technology which has lowered energy requirements. The development of atrial-independent, variable rate systems has enabled rate adaptation in patients who are not candidates for DDD-stimulation or in whom the atrial rate is inadequate. With Holter functions various physiological parameters can be continuously monitored and their response as well as biorhythmicity are analyzed. INDICATIONS: The following guidelines are those of the working group "Cardiac Pacing" of the German Society for Heart and Circulatory Research for the choice of pacemaker systems which are considered to provide the best respective physiologic form of stimulation with the goal of rendering optimal hemodynamics. For characterization of the pacemaker modes, the five-letter NASPE/BPEG code is used. The possibility for single modes, AV-synchrony and rate adaptation as central factors for physiologic stimulation forms is shown in Table 2. Those systems are designated as "physiologic" which reestablish AV-synchrony, that is, pacing modes in which the atria are incorporated With the VAT-, VDD- and DDD-modes there is an additional atrial-triggered rate modulation. In AAI- order DDD/I-modes rate adaptation is independent of the atria (AAIR, DDD/IR) via physiologic parameters while rate-adaptive VVI stimulation does not enable AV-synchrony. Atrioventricular conduction disturbances: Pacemaker treatment is carried out for prevention of Adams-Stokes symptoms and for improvement of the hemodynamic situation. Prognostic implications of pacemaker treatment: With pacemaker treatment the one-year mortality of patients with Adams-Stokes symptoms and/or complete AV-block can be lowered to 5 to 19% from 50 to 70%.(ABSTRACT TRUNCATED AT 400 WORDS)

Bradycardia

Body fat distribution in men with angiographically confirmed coronary artery disease.

Body fat distribution and its relationship to coronary artery disease and established cardiovascular risk factors have been studied in a cohort of 286 men aged between 30 and 74 years undergoing coronary angiography. 207 (72.4%) patients showed stenosis (greater than 30%) or occlusion of one or more coronary arteries. whereas the remaining 79 (27.6%) men were free of coronary lesions and served as a control group. 112 men with angiographically defined coronary artery disease had an additional history of myocardial infarction. Body fat distribution was assessed by determining the waist-to-hip circumference ratio. A stepwise logistic regression analysis revealed that in addition to LDL-cholesterol (P = 0.0001) and age (P = 0.0005) an abdominal type of body fat distribution (P = 0.0129) is also a significant risk indicator for the occurrence of coronary artery disease (CAD) independent of body weight and other factors such as total cholesterol, HDL-cholesterol, triglycerides, insulin, systolic and diastolic blood pressure. The results of this study suggest that an abdominal type of fat distribution is associated with an increased risk of coronary artery disease.

Adipose Tissue

Differences between atrial single chamber pacing (AAI) and ventricular single chamber pacing (VVI) with respect to prognosis and antiarrhythmic effect in patients with sick sinus syndrome.

Several studies suggest different effects of atrial (AAI) and ventricular single chamber pacing (VVI) for sick sinus syndrome with respect to the suppression of atrial tachycardias and to the prognosis. With this aspect in mind, we studied 222 patients with sick sinus syndrome, 110 of whom had been supplied with AAI systems, and 112 with VVI systems, in the period from January 1978 to December 1986. The mean observation period was 53 +/- 28 months. The cumulative 5-year survival rate was not significantly different in the two groups. After subgroups with comparable underlying diseases had been differentiated, patients with coronary heart disease showed a significantly higher survival rate (P less than 0.05) under AAI pacing, and the same was shown for patients with no underlying heart disease (P less than 0.02). The incidence of chronic atrial fibrillation was 6% in the AAI group and 19% in the VVI group. Patients with preexisting atrial tachyarrhythmias showed the lowest incidence of chronic atrial fibrillation under AAI pacing. Under VVI pacing this incidence was a function of the basic rate of the pacemaker systems. In conclusion, the pacing mode seems to have a prognostic importance in spite of all methodological difficulties. A suppressive effect of AAI pacing on atrial dysrhythmias can also be assumed.

Aged

[Acute reduction of increased atrial natriuretic peptide level and cyclic guanosine monophosphate in patients with chronic heart failure caused by beta-adrenergic stimulation with dopexamine hydrochloride. Correlation with hemodynamic parameters].

In eight patients (63 +/- 8 years) with dilated cardiomyopathy, the acute effects of positive inotropic stimulation with dopexamine hydrochloride, a beta-2-agonistic and DA1-dopaminergic catecholamine, on the plasma levels of ANP and cGMP were tested. A four-point dose-response curve was prepared for dopexamine from 1 microgram/kg/min to 4 micrograms/kg/min. Each infusion stage lasted 15 min; ANP and cGMP were taken from the mixed venous blood. Hemodynamic parameters were determined by a Swan-Ganz catheter; cardiac output was determined by thermodilution. ANP dropped by 40% from 348 +/- 124 pg/ml to 208 +/- 70 pg/ml (p less than or equal to 0.01), while cGMP dropped by 25% from 4.8 +/- 1.6 pmol to 3.6 +/- 1.3 pmol/ml at the time of maximum hemodynamic effect after 1 h. Linear regression analyses revealed a significant relationship (p less than or equal to 0.01) between ANP as the independent variable and cGMP as the dependent variable. The hemodynamic determinants of the ANP concentration proved to be--independently of each other--the pulmonary capillary wedge pressure (p less than or equal to 0.01) and the mean right atrial pressure (p less than or equal to 0.01). The results show that chronically elevated ANP and cGMP levels can be strikingly reduced within a short time, whereby ANP and cGMP show similar kinetics. The results suggest a use of ANP and cGMP as humoral parameters in the therapy control of chronic heart failure.

Adrenergic beta-Agonists

[30 years cardiac pacemaker therapy: a status evaluation].

Antibradycardiac pacemaker therapy has become established as one of the most effective forms of cardiological therapy for the indications AV-block, sick sinus syndrome, bradyarrhythmia, and hypersensitive carotid sinus. About 220,000 systems are implanted per year worldwide, about 32,000 in West Germany. Of the pacing modes, the fixed-rate ventricular single chamber systems (VVI) dominate with a share of almost 90%. Prognostic importance: For AV-block, the improvement of the prognosis by pacemaker therapy is unquestionable, since it increases the cumulative survival rates to 81% and 95% after 1 year and 50% to 65% after 5 years. For sick sinus syndrome, VVI-pacing proves to be a symptomatic measure, no prognostic importance can be proven. It is not conclusively clarified at present whether physiological pacing modes (AAI, DDD) have any such importance. Pacemaker therapy also has no prognostic importance for bradyarrhythmia. Hemodynamic importance: Numerous hemodynamic studies show that fixed-rate VVI-pacing fails to produce a long-term hemodynamic improvement for either an AV-block or a sick sinus syndrome. In sick sinus syndrome hemodynamic improvement can only be achieved by physiological pacing modes (AAI, DVI, DDD), whereby the increase in cardiac output is between 11% to 30%. For AV-block a long-term hemodynamic improvement can only be obtained by atrial triggered pacing modes (VAT, VDD, DDD); this is higher than the values of fixed-rate VVI-pacing by 7-25% at rest, or 10-40% under exercise. Similar results with improvements of the exercise hemodynamics between 22% and 66% are reported for rate-modulated single-chamber pacing (VVIR) for AV-block. Future trends: In the fourth decade of pacemaker therapy, developments point toward the "smart pacemaker", toward rate-modulated systems with combinations of parameters, toward rate-modulated dual-chamber systems and universal antibradycardiac and antitachycardiac systems.

Bradycardia

Physical movement sensitive pacing: comparison of two "activity"-triggered pacing systems.

The Activitrax (A) and the Sensolog (S) pulse generator units were compared during bench tests and in patients both under ergometric conditions and during daily activities to determine the susceptibility of both systems to external noise. During the bench tests both pacemakers were mounted on a swingboard and subjected to controlled vibrational force. The patients were divided into two groups of 10 patients each, one group with A and the other with S units; the discriminating power of workload changes was examined under treadmill exercise. In six patients of each group the rate behavior of S and A during daily activities was recorded by Holter monitoring. During bench tests, S and A displayed a frequency-selective mode of operation between 2-70 Hz with the greatest sensitivity between 10-50 Hz. In patients, S showed a significantly higher discriminating power to changes in workload during treadmill exercise. According to y = 0.27x + 85.8 (r = 0.92) the relationship between the power and the pacing rate of S was linear, whereas with y = 0.04x + 89.8 (r = 0.2) the pacing rate of A was almost independent of the given power. The susceptibility to external noise occurring while riding in an auto, streetcar or train with rate increases between 7 ppm and 12 ppm did not significantly differ in both systems. Lying prone on the pacemakers produced brief (less than 1 min) rate increases of 38 ppm (S) and 18 ppm (A), respectively.

Cardiac Pacing, Artificial

Binding sites for atrial natriuretic peptide on platelets in patients with congestive cardiomyopathy.

The aim of the present investigation was to evaluate a possible down-regulation of atrial natriuretic peptide (ANP) binding sites on platelets in patients with chronically elevated ANP plasma levels. The assay procedure was proved to be able to measure the total number of binding sites even in the presence of high ANP plasma levels. We studied 15 adult patients with congestive cardiomyopathy in comparison to 18 healthy volunteers. In the patients the median ANP plasma level (median = 375, range: 155-900 pg ml-1) was about six-fold higher than in the healthy volunteers (median: 55.5, range: 20-90 pg ml-1). The median cyclic guanosine monophosphate (cGMP) plasma level (median: 6.2, range: 2.5-21.4 pmol ml-1) was about three-fold higher than in the healthy volunteers (median: 1.8 range: 1-2.8 pmol ml-1). Despite these markedly elevated ANP and cGMP plasma levels we did not find significantly less receptors per platelet in the patients (median: 19, range: 7.2-60.2) than in the healthy volunteers (median: 24.5, range: 14.8-41.1). Furthermore, there was no difference in the dissociation constants between the patients (median: 10.5, range: 7.9-27.4 pmol l-1) and the control subjects (median: 8.9, range: 5.4-17 pmol l-1).

Aged

Influence of AV synchrony on the plasma levels of atrial natriuretic peptide (ANP) in patients with total AV block.

ANP was determined in 13 patients with DDD pacemakers due to total AV block, at rest and during bicycle ergometry under both pacing modes, DDD and VVI (7O/min). Under DDD pacing, the mean ANP level (normal range 5-95 pg/mL) at rest was 36 +/- 18 pg/mL (mean +/- SD) and increased significantly by the factor of 3.5 to 1 27 pg/mL during exercise (p less than 0.01). By just changing the pacing mode to VVI, the ANP levels rose to 73 +/- 28 pg/mL (p less than O.0 1) at rest (= 203% of DDD resting level) and to 216 +/- 184 pg/mL (= 170% of DDD peak level) during exercise P less than 0.01). These results show that under AV synchronous pacing, the ANP levels we generally lower. A possible explanation for this increased release of ANP during asynchronous VVI pacing is the acute increase of the atrial wall tension which occurs when the atria contacts during the systole against closed AV valves.

Aged

A new multisensor pacing system using stroke volume, respiratory rate, mixed venous oxygen saturation, and temperature, right atrial pressure, right ventricular pressure, and dP/dt.

A new multisensor pacing device using respiratory rate (RR), stroke volume (SV), oxygen saturation (SO2), temperature (T), right atrial pressure (RAP), right ventricular pressure (RVP) and right ventricular dP/dt, has been developed. It consists of a 7F multisensor catheter and an external pacing unit. It allows simultaneous recording of the input signals and the corresponding data can be compared among the different parameters under identical conditions. Furthermore, several parameters can be combined in such a way as to form a new combination better suitable for rate responsive pacing. The response of each parameter to exercise was studied in 12 healthy volunteers (mean age: 28 years). Exercise testing was carried out using a bicycle ergometer, with workloads up to 200 W. The dynamic characteristics, response and sensitivity to changes of workloads of each parameter were analyzed and compared to one another. SO2 proved to be a quick responding parameter (less than 10 sec) with higher sensitivity in the low exercise range (less than 75 W), T, on the other hand, responded slowly (greater than 30 sec) to exercise changes and had the highest sensitivity in the exercise range beyond 75 W. RR displayed a slow response (greater than 30 sec) and an adequate sensitivity was only found in the upper exercise range (greater than 100 W). SV reacted rapidly to workload changes (less than 10 sec) but showed poor sensitivity at all exercise levels. RAP, RVP and dP/dt displayed quick responses and constantly good sensitivity throughout the workload range. Furthermore, respiratory rate was easily derived from the RAP curve. Special algorithms were developed for each parameter so that pacing rate would reproduce sinus rate behavior. We found that SO2 and all pressure parameter imitated sinus rate response quite well. When using parameter combinations, SO2 and T proved to be superior. Five patients (mean age 68 years) with third degree AV-block were stimulated temporarily using this system. Compared to fixed rate stimulation (VVI 70), exercise performance improved, using SO2 as the input parameter for rate response, by 25% to 50%.

Adult