Effect of film graininess and geometric unsharpness on image quality in fine-detail skeletal radiography.

Three direct x-ray films and three geometric conditions were used to study the effect of noise and sharpness on high resolution radiography of the hand. The Wiener spectrum of film graininess and the MTF of geometric unsharpness were measured. Radiographs of a wire mesh and a hand phantom, together with the Wiener spectra and MTFs, led to the following conclusions regarding fine-detail skeletal radiography, as currently employed: 1) bone structure detectable in vivo does not show minute structural detail; 2) the technique is primarily noise-limited; 3) the use of better geometry or finer grain film for improving resolution or noise is of limited practical value, whereas the use of poorer geometry or more noisy film results in appreciable degradation of skeletal images; and 4) the present standard technique for in vivo radiography of the hand, therefore, may be very nearly optimal for clinical applications.

Bone and Bones↗

The effect of geometric and recording system unsharpness in mammography.

Modulation transfer functions (MTFs) and test object radiographs were used to study the effect of geometric and recording system unsharpness in mammography with the CGR Senographe x-ray unit. Results show that geometric unsharpness can be a significant factor in the detection of microcalcifications within the breast, depending on the size and shape of the focal spot, the focal spot-to-recording system distance, and the object-to-recording system distance (o.r.d.). A new recording system for mammography, the DuPont Lo-dose system, requires approximately 1/15th the exposure of a direct x-ray film, such as Kodak RP/M, to provide mammograms with comparable photographic density. With the Lo-dose system, geometric unsharpness can be reduced by use of a specially designed long cone with an increased focal spot-to-recording system distance. This cannot be accomplished with direct x-ray films because the x-ray unit is operating at near-maximum output conditions even when short cones are used. Although direct x-ray films have a higher resolution than the Lo-dose system, at certain o.r.d.s total resolution is found to be affected more significantly by geometric unsharpness than by the Lo-dose recording system. In several cases, clinical results show improved detection of microcalcifications at larger o.r.d.s by the Lo-dose system with a long one, combined with a reduction by a factor of 15 in patient exposure.

Breast Neoplasms↗

New device for accurate measurement of the x-ray intensity distribution of x-ray tube focal spots.

A new device has been developed with which the focal spot distribution can be measured accurately. The alignment and localization of the focal spot relative to the device are accomplished by adjustment of three micrometer screws in three orthogonal directions and by comparison of red reference light spots with green fluorescent pinhole images at five locations. The standard deviations for evaluating the reproducibility of the adjustments in the horizontal and vertical directions were 0.2 and 0.5 mm, respectively. Measurements were made of the pinhole images as well as of the line-spread functions (LSFs) and modulation transfer functions (MTFs) for an x-ray tube with focal spots of 1-mm and 50-mum nominal size. The standard deviations for the LSF and MTF of the 1-mm focal spot were 0.017 and 0.010, respectively.

Radiographic Image Enhancement↗

X-ray images of small blood vessels in angiography: question of isoplanatism.

The basic theory of x-ray image formation of blood vessels, which is related to isoplanatism, is discussed. The x-ray intensity distributions of the blood vessel images are derived first for the actual case, which gives "correct" x-ray images obtained by the ray-tracing method. Secondly, as an approximation of the actual case, the image distributions are derived by the convolution method, which corresponds to an isoplanatic case. It is concluded that, under practical conditions, x-ray images of blood vessels are given approximately by a convolution integral of the object distribution, that is, the input x-ray pattern of the vessel exposed with a parallel x-ray beam, with the line spread function of geometric unsharpness. Therefore, this theory provides support for the experimental procedure commonly used in obtaining blood vessel images, and for the validity of applying in angiography the concept of the line spread function and the modulation transfer function of geometric unsharpness.

Angiography↗

Validity of computer simulation of blood vessel imaging in angiography.

The computer-simulation technique for imaging of vessels in angiography is being recognized as a useful tool for the study of the effect of physical parameters on the vessel image. We have examined the validity of this technique by comparing the computed image distribution directly with experimental results. The imput x-ray pattern of a blood vessel phantom, the LSF of the focal spot, and the LSF of a screen-film system were measured. From the data obtained, the final image distributions of the phantom were computed and compared with the experimentally determined distributions. A high-precision device for the alignment and positioning of the vessel phantom was employed in the experiments. Results indicate that computer simulation can correctly predict the image distribution of the blood vessel phantom.

Angiography↗

Comparison of convolution and ray-tracing methods for computing small blood vessel images in angiography.

Two methods for computing x-ray images of small blood vessels in angiography are presently available, namely, convolution and ray tracing. The convolution method, which is simpler and more powerful than the ray-tracing method, is based on the assumption that blood vessel imaging is isoplantic, whereas ray tracing is considered to provide correct images. In this study, the approximation error (difference between two images, normalized by the maximum value) due to nonisoplanatic imaging was determined by computation of blood vessel images according to both methods. The approximation error for geometric conditions normally encountered in angiography was less than 0.01. It is concluded that an approximation error of this magnitude is negligible and that the convolution method can be applied instead of the ray-tracing method for the computation of images of small blood vessels.

Angiography↗