Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia.

AIMS/HYPOTHESIS: Glucose sensors often measure s.c. interstitial fluid (ISF) glucose rather than blood or plasma glucose. Putative differences between plasma and ISF glucose include a protracted delay during the recovery from hypoglycaemia and an increased gradient during hyperinsulinaemia. These have often been investigated using sensor systems that have delays due to signal smoothing, or require long equilibration times. The aim of the present study was to define these relationships during hypoglycaemia in a well-equilibrated system with no smoothing. METHODS: Hypoglycaemia was induced by i.v. insulin infusion (360 pmol.m(-2).min(-1)) in ten non-diabetic subjects. Glucose was sequentially clamped at approximately 5, 4.2 and 3.1 mmol/l and allowed to return to normoglycaemia. Subjects wore two s.c. glucose sensors (Medtronic MiniMed, Northridge, CA, USA) that had been inserted for more than 12 h. A two-compartment model was used to quantify the delay and gradient. RESULTS: The delay during the fall in plasma glucose was not different from the delay during recovery (8.3+/-0.67 vs 6.3+/-1.1 min; p=0.27) and no differences were observed in the ratio of sensor current to plasma glucose at basal insulin (2.7+/-0.25 nA.mmol(-1).l) compared with any of the hyperinsulinaemic clamp phases (2.8+/-0.18, 2.7+/-0.021, 2.9+/-0.21; p=NS). The ratio was significantly elevated following recovery to normoglycaemia (3.1+/-0.2 nA.mmol(-1).l; p<0.001). CONCLUSIONS/INTERPRETATION: The elevated ratio suggests that the plasma to ISF glucose gradient was decreased following hypoglycaemia, possibly due to increased skin blood flow. Recovery from hypoglycaemia is not accompanied by a protracted delay and insulin does not increase the plasma to s.c. ISF glucose gradient.

Adult↗

Modeling insulin action for development of a closed-loop artificial pancreas.

Three models of glucose homeostasis are compared in terms of their steady-state dose-response characteristics, how they characterize glucose distribution kinetics, and how they characterize the dynamics of insulin action. The three models [minimal model, AIDA (Automated Insulin Dosage Advisor), and a model by Sorensen] are used to discuss a wider variety of questions related to metabolic modeling. Simulations are performed comparing each model's response to an intravenous glucose tolerance test, with and without incremental insulin responses, to existing data in individuals with type 1 diabetes mellitus. Predicted changes in blood glucose following a subcutaneous bolus of insulin or an incremental increase in basal insulin delivery are simulated. From these results, the models are evaluated as potential candidates for simulating changes in treatment and developing a closed-loop insulin delivery algorithm. While no consensus model is proposed, relevant issues needing to be addressed are highlighted.

Algorithms↗

Closed-loop insulin delivery-the path to physiological glucose control.

The development of an artificial pancreas for the treatment of insulin-dependent diabetes is a highly desired endeavor for patients, physicians, scientists, and engineers. Historical algorithms and recent progress in research and technology are reviewed in the present article, together with aspects of beta-cell physiology that lead to normal glucose tolerance. Algorithms are evaluated for their ability to deliver insulin as to recreate, as closely as possible, glucose and insulin profiles observed in healthy individuals. Emphasis is placed upon how the algorithms compare to the beta-cell's secretory response, specifically first-phase and second-phase insulin secretion. Experimental closed-loop data employing intravenous and subcutaneous glucose sensors and implanted and external insulin pumps (Medtronic MiniMed, Northridge CA) are presented.

Algorithms↗

Can interstitial glucose assessment replace blood glucose measurements?

Current treatment regiments for individuals depending on exogenous insulin are based on measurements of blood glucose obtained through painful finger sticks. The shift to minimal or noninvasive continuous glucose monitoring primarily involves a shift from blood glucose measurements to devices measuring subcutaneous interstitial fluid (ISF) glucose. As the development of these devices progresses, details of the dynamic relationship between blood glucose and interstitial glucose dynamics need to be firmly established. This is a challenging task insofar as direct measures of ISF glucose are not readily available. The current article investigated the dynamic relationship between plasma and ISF glucose using a model-based approach. A two-compartment model system previously validated on data obtained with the MiniMed Continuous Glucose Monitoring System (CGMS) is reviewed and predictions from the original two-compartment model were confirmed using new data analysis of glucose dynamics in plasma and hindlimb lymph (lymph is derived from ISF) in the anesthetized dog. From these data sets, the time delay between plasma and ISF glucose in dogs was established (5-12 minutes) and a simulation study was performed to estimate the errors introduced if ISF is taken as a surrogate for blood. From the simulation study, the error component resulting from the differences in plasma and ISF glucose was estimated to be < 6% during normal day-to-day use in an individual with diabetes (error component calculated as the standard deviation of the ISF/plasma glucose differences under conditions where the maximal time delay was used). This difference is most likely within the variance between arterial and venous blood glucose. We conclude that the differences between plasma and ISF glucose will not be a significant obstacle in advancing the use of ISF as an alternative to blood glucose measurements.

Biosensing Techniques↗

Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring.

The present study investigated the relationship between blood and subcutaneous interstitial fluid (ISF) glucose by employing an amperometric glucose sensor specifically developed for 3-day continuous glucose monitoring. The apparent sensor sensitivity and ISF glucose equilibration delay were estimated on separate days during hyperglycemic clamps in four dogs in which insulin was either suppressed with somatostatin, allowed to change, or increased with an exogenous infusion. A 2-h sensor "settling-in" period was allowed before the clamps. During insulin deficiency, the sensor sensitivity and ISF glucose delay were 0.23 +/- 0.03 nA per mg/dl and 4.4 +/- 0. 8 min. Sensitivity was not affected by increases in endogenous (0.30 +/- 0.04 vs. 0.28 +/- 0.04 nA per mg/dl) or exogenous insulin (0.18 +/- 0.01 vs. 0.16 +/- 0.01 nA per mg/dl) nor was the delay (3.3 +/- 1.2 vs. 5.7 +/- 1.1 and 9.2 +/- 2.6 vs. 12.3 +/- 1.7 min; P > 0.05 for all). Sensor glucose accurately predicted plasma glucose without correcting for delays <10 min (r > 0.9 for all), whereas for longer delays a digital corrective filter was used (r = 0.91 with filter). We conclude that the relationship between blood and ISF glucose is not affected by insulin and that delays in ISF glucose equilibration can be corrected with digital filters.

Animals↗

Role of portal insulin delivery in the disappearance of intravenous glucose and assessment of insulin sensitivity.

The contribution of portal insulin delivery to the disappearance of glucose administered intravenously was assessed in the present study. Paired insulin-modified intravenous glucose tolerance tests (IVGTTs) were performed in dogs in which insulin was administered into the portal vein or into a peripheral vein. Peripheral insulin levels were matched in the paired IVGTTs by adjusting the portal insulin dose in proportion to first-pass hepatic insulin extraction. Two sets of IVGTTs were performed. In the first set, hepatic insulin extraction was assumed to be 50% (insulin doses of 0.03 U/kg portal and 0.015 U/kg peripheral; n = 6); in the second set, the assumed extraction rate was reduced to 33% (0.0225 U/kg portal and 0.015 U/kg peripheral; n = 8). In the second set of experiments, a control "zero" dose (no insulin injection) was also performed. For these latter three IVGTTs, the exogenous glucose bolus was labeled with 3-[3H]glucose (25 microCi) to separately assess insulin's effects on the rate of glucose disappearance (Rd) and endogenous glucose production (EGP). For the paired IVGTT based on 33% extraction, the area under the insulin curves after the portal insulin injection was within 2% of that observed with peripheral insulin injection (1,820 +/- 711 vs. 1,791 +/- 661 microU/ml min; P = 0.79). For these conditions, neither the glucose profiles nor the minimal model estimate of insulin sensitivity (S(I)) was significantly influenced by the higher portal insulin delivery (S(I): 3.69 +/- 0.56 vs. 3.35 +/- 0.60 10(-4) min(-1) per microU/ml; portal vs. peripheral; P > 0.05). Analysis of the 3-[3H]glucose tracer dynamics failed to reveal any differences in the portal versus peripheral insulin effect on glucose disappearance or production. We conclude that portal insulin delivery per se does not significantly affect insulin's ability to normalize plasma glucose during acute glucose challenges.

Animals↗

Indirect effect of insulin to suppress endogenous glucose production is dominant, even with hyperglucagonemia.

Suppression of endogenous glucose production (EGP) is one of insulin's primary metabolic effects and failure of this action is a major contributor to fasting hyperglycemia of type 2 diabetes mellitus. Classically, insulin was thought to suppress the liver directly, via hyperinsulinemia in the portal vein. Recently, however, we and others have demonstrated that at least part, and possibly most of insulin's action to suppress EGP is normally mediated via an extrahepatic (i.e., indirect) mechanism. We have suggested that this mechanism involves insulin suppression of adipocyte lipolysis, leading to lowered FFA and reduced EGP ("Single Gateway Hypothesis"). Previous studies of the indirect insulin effect from this laboratory were done under conditions of lowered portal glucagon. Because of the possibility that the direct (i.e., portal) effect of insulin may have been underestimated with hypoglucagonemia, these studies examined the relative importance of portal insulin, versus peripheral insulin (administered at one-half the dose to equalize peripheral insulin levels) at four rates of portal glucagon infusion: 0, 0.65 (under-), 1.5 (basal-), and 3.0 ng/kg per min (over-replacement). Portal versus peripheral insulin suppressed steady-state EGP to the same extent (52%), confirming that the primary effect of insulin to suppress EGP is via the peripheral mechanism. This conclusion was maintained regardless of portal glucagonemia, although there was some evidence for an increase in the direct insulin effect at hyperglucagonemia. The indirect effect of insulin is the primary mechanism of steady-state EGP suppression under normal conditions. The direct effect increases with hyperglucagonemia; however, the indirect effect remains predominant even under those conditions.

Animals↗

Causal linkage between insulin suppression of lipolysis and suppression of liver glucose output in dogs.

Suppression of hepatic glucose output (HGO) has been shown to be primarily mediated by peripheral rather than portal insulin concentrations; however, the mechanism by which peripheral insulin suppresses HGO has not yet been determined. Previous findings by our group indicated a strong correlation between free fatty acids (FFA) and HGO, suggesting that insulin suppression of HGO is mediated via suppression of lipolysis. To directly test the hypothesis that insulin suppression of HGO is causally linked to the suppression of adipose tissue lipolysis, we performed euglycemic-hyperinsulinemic glucose clamps in conscious dogs (n = 8) in which FFA were either allowed to fall or were prevented from falling with Liposyn plus heparin infusion (LI; 0.5 ml/min 20% Liposyn plus 25 U/min heparin with a 250 U prime). Endogenous insulin and glucagon were suppressed with somatostatin (1 microgram/min/kg), and insulin was infused at a rate of either 0.125 or 0.5 mU/min/kg. Two additional experiments were performed at the 0.5 mU/min/kg insulin dose: a double Liposyn infusion (2 x LI; 1.0 ml/min 20% Liposyn, heparin as above), and a glycerol infusion (19 mg/min). With the 0.125 mU/min/kg insulin infusion, FFA fell 40% and HGO fell 33%; preventing the fall in FFA with LI entirely prevented this decline in HGO. With 0.5 mU/min/kg insulin infusion, FFA levels fell 64% while HGO declined 62%. Preventing the fall in FFA at this higher insulin dose largely prevented the fall in HGO; however, steady state HGO still declined by 18%. Doubling the LI infusion did not further affect HGO, suggesting that the effect of FFA on HGO is saturable. Elevating plasma glycerol levels did not alter insulin's ability to suppress HGO. These data directly support the concept that insulin suppression of HGO is not direct, but rather is mediated via insulin suppression of adipose tissue lipolysis. Thus, resistance to insulin control of hepatic glucose production in obesity and/or non-insulin-dependent diabetes mellitus may reflect resistance of the adipocyte to insulin suppression of lipolysis.

Animals↗

Transendothelial insulin transport is not saturable in vivo. No evidence for a receptor-mediated process.

In vitro, insulin transport across endothelial cells has been reported to be saturable, suggesting that the transport process is receptor mediated. In the present study, the transport of insulin across capillary endothelial cells was investigated in vivo. Euglycemic glucose clamps were performed in anesthetized dogs (n = 16) in which insulin was infused to achieve concentrations in the physiological range (1.0 mU/kg per min + 5 mU/kg priming bolus; n = 8) or pharmacologic range (18 mU/kg per min + 325 mU/kg priming bolus; n = 8). Insulin concentrations were measured in plasma and hindlimb lymph derived from interstitial fluid (ISF) surrounding muscle. Basal plasma insulin concentrations were twice the basal ISF insulin concentrations and were not different between the physiologic and pharmacologic infusion groups (plasma/ISF ratio 2.05 +/- 0.22 vs 2.05 +/- 0.23; p = 0.0003). The plasma/ISF gradient was, however, significantly reduced at steady-state pharmacologic insulin concentrations (1.37 +/- 0.25 vs 1.98 +/- 0.21; P = 0.0003). The reduced gradient is opposite to that expected if transendothelial insulin transport were saturable. Insulin transport into muscle ISF tended to increase with pharmacologic compared with physiologic changes in insulin concentration (41% increase; 1.37 +/- 0.18 10(-2) to 1.93 +/- 0.24 10(-2) min-1; P = 0.088), while at the same time insulin clearance out of the muscle ISF compartment was unaltered (2.53 +/- 0.26 10(-2) vs 2.34 +/- 0.28 10(-2) min-1; P = 0.62). Thus, the reduced plasma/ISF gradient at pharmacologic insulin was due to enhanced transendothelial insulin transport rather than changes in ISF insulin clearance. We conclude that insulin transport is not saturable in vivo and thus not receptor mediated. The increase in transport efficiency with saturating insulin is likely due to an increase in diffusionary capacity resulting from capillary dilation or recruitment.

Animals↗

Extracellular glucose distribution is not altered by insulin: analysis of plasma and interstitial L-glucose kinetics.

We examined the effects of insulin on leg blood flow, whole body extracellular glucose distribution, and glucose diffusion into the interstitial fluid (ISF) surrounding skeletal muscle cells in anesthetized dogs. Extracellular glucose distribution and glucose diffusion into the muscle ISF were assessed by studying the kinetics of L-[1-14C]glucose in plasma and hindlimb lymph. Femoral artery blood flow was not increased with insulin (7.9 +/- 0.7 vs. 7.1 +/- 1.4 ml.min-1.kg-1; P = 0.54). Plasma and lymph dynamics of L-glucose after intravenous administration were superimposable between saline and insulin infusion experiments, indicating that insulin did not affect L-glucose disappearance from plasma or appearance in muscle ISF. Plasma L-glucose kinetics were best described by a four-compartment model, and one of the remote pools (intermediate) predicted the lymph L-glucose dynamics well. Estimation of maximum glucose diffusion capacity indicated that this pool, rather than the slowest pool, represents insulin-sensitive tissues. In conclusion, our data indicate that insulin does not increase transcapillary glucose diffusion to insulin-sensitive cells. In addition, hindlimb lymph represents primarily skeletal muscle ISF, which is represented by an intermediate, rather than the slowest, remote pool from whole body compartmental analysis.

3-O-Methylglucose↗

Increased urea synthesis in insulin-dependent diabetic dogs maintained normoglycemic: effect of portal insulin administration and food protein content.

In IDDM, the gluconeogenic turnover of amino acids is increased even if glycemia is well controlled and may be restored to normal by means of prehepatic insulin substitution. Therefore, the present study was designed 1) to investigate the influence of route of insulin administration (portal versus peripheral) on the urea production rate, which is considered to measure amino acid catabolism, and 2) to elucidate the impact of different food-protein intake. Paired studies were conducted in chronic insulin-dependent diabetic dogs maintained normoglycemic. Diabetic animals and nondiabetic controls were fed either a high-protein diet (46% of energy intake provided by proteins; study 1) or a low-protein carbohydrate-supplemented diet (20% of energy intake provided by protein; study 2) for 2 days, and flux rates of glucose and urea were measured using isotope dilution techniques. In both studies, the diabetic animals were maintained normoglycemic by glucose-controlled insulin infusion delivered either systemically or portally. In study 1 versus study 2, the animals showed lower alpha-amino nitrogen levels and concentrations of gluconeogenic amino acids, predominantly alanine. There were no significant differences in plasma glucose and glucose turnover between the experimental groups on either systemic or portal insulin infusion versus controls; however, peripheral insulin levels were higher for diabetic animals maintained with systemic versus portal insulin delivery (P < 0.05). No significant differences in glucagon, lactate, pyruvate, nonesterified fatty acids, or beta-hydroxybutyrate were observed. Urea production was significantly higher in study 1 compared with study 2: 7.48 +/- 0.83 vs. 5.97 +/- 0.59 micromol / kg / min (normal dogs); 12.97 +/- 1.86 vs. 5.54 +/- 0.60 micromol / kg / min (diabetic dogs on portal insulin); 16.11 +/- 2.59 vs. 6.82 +/- 0.70 micromol / kg / min (diabetic dogs on systemic insulin infusion); P < 0.05 for all. The diabetic dogs maintained normoglycemic with systemic insulin infusions had significantly higher rates of urea synthesis than those with portal insulin infusion (P < 0.05). It is concluded that in IDDM, even if normoglycemia is managed, there is significantly increased amino acid catabolism with posthepatic systemic insulin treatment. This increased catabolic rate is more pronounced during high-protein nourishment.

Animals↗

Toward an integrated phenotype in pre-NIDDM.

The search for the genetic basis of NIDDM has magnified the need for an efficient representation of the pre-NIDDM phenotype. The overall goal is to relate specific mutations on the genome to specific changes in physiologic function which lead to NIDDM. Unfortunately, there is still not a clear understanding of the molecular cause of NIDDM in most individuals. Therefore, one must take an alternative approach: to express in quantitative terms the various tissue processes which determine the ability to regulate the blood glucose in fasting and after carbohydrate administration. A minimal list of such processes includes the provision of glucose by the liver, insulin sensitivity, insulin secretion, and glucose effectiveness. The latter function is the ability of glucose per se to enhance glucose disappearance from blood, independent of a dynamic insulin response. Approaches to measuring the list of functions which determine the glucose tolerance are reviewed: they include the minimal model method, which quantitates insulin sensitivity (Sl) and glucose effectiveness (SG), and a combined model approach, which measures insulin secretion. These methods are being developed for large populations. Such a development is important for elucidating the causes of reduced glucose tolerance in populations, and examining the relation between such causes and outcomes including diabetes and cardiovascular disease. Of particular importance for diabetes development is the characteristic hyperbolic relationship between insulin secretion and insulin action. This relationship, the "hyperbolic law of glucose tolerance' indicates that insulin secretion can only be assessed in terms of the ambient degree of insulin sensitivity. By applying this principle, it is clear that latent pancreatic islet-cell dysfunction has been underestimated, and may be significant even in subjects with impaired glucose tolerance. Finally, new explorations of insulin control of liver glucose output indicate that this process may be under the control of free fatty acids. The latter realization indicates that the insulin effect on lipolysis is what is critical for determination of glucose output in the fasting state, and that insulin resistance at the level of the adipocyte may determine the extent of fasting hyperglycaemia, and may be an important factor in the overall phenotype in prediabetic and NIDDM individuals.

Animals↗

Free fatty acid as a link in the regulation of hepatic glucose output by peripheral insulin.

Overproduction of glucose by the liver in the face of insulin resistance is a primary cause of hyperglycemia in non-insulin-dependent diabetes mellitus (NIDDM). However, mechanisms involved in control of hepatic glucose output (HGO) remain less than clear, even in normal individuals. Recent results have supported an indirect extrahepatic effect of insulin as the primary locus of insulin action to restrain HGO. One suggested extrahepatic site is the pancreatic alpha-cell. To examine whether insulin's extrahepatic site is independent of the alpha-cells, HGO suppression was examined independent of changes in glucagon secretion or insulin antagonism of glucagon action. Euglycemic glucose clamps (n = 40) with somatostatin infusion were performed in conscious dogs (n = 5). Paired experiments were conducted in which insulin was infused either portally (1.2, 3.0, 6.0 pmol.min-1.kg-1) or peripherally at half the portal infusion rate (0.6, 1.5, 3.0 pmol.min-1.kg-1). Additional zero and saturating portal-dose experiments (100 pmol.min-1.kg-1) were also performed. For the paired experiments, portal insulin infusion resulted in portal insulin concentrations approximately two to three times higher than in the corresponding peripheral insulin infusion experiments, while at the same time peripheral insulin concentrations were approximately matched. Equal peripheral insulin concentration resulted in equivalent HGO suppression irrespective of the portal concentrations. Thus, insulin affects a signal at a peripheral site, other than alpha-cell, that in turn suppresses hepatic glucose production. To investigate the nature of this signal, we measured alanine, lactate, and free fatty acids (FFAs).(ABSTRACT TRUNCATED AT 250 WORDS)

Alanine↗

Clinical usefulness of the glucose concentration in the subcutaneous tissue--properties and pitfalls of electrochemical biosensors.

Biosensors are miniaturized analytical tools which comprise a biological detection element providing specificity to the analyte, and a physical transducer which guarantees an output signal, e.g. an electric current the size of which is proportional to the concentration of the analyte. They provide the unique possibility of continuous in vivo monitoring. Glucosensors were in fact the first biosensors under study. Among them, the most advanced devices are measuring amperometrically the hydrogen peroxide generated in a stoichiometric relation to the prevailing glucose concentration during glucose oxidase-mediated glucose oxidation. They proved useful in commercially available glucose analyzers and in experimental subcutaneous monitoring. Here it is shown (a) that under steady state conditions the s.c. glucose concentration is nearly identical to that in blood, (b) that s.c. inserted glucose electrodes do mirror the intracorporal glucose concentration both under hypo-, normo-, and hyperglycaemic conditions with a clinically relevant accuracy, (c) that even stable feedback control of intracorporal glucose concentration is possible employing s.c. glucosensor signal as an input to automated insulin pump controller, and (d) that stable function of s.c. sensor is usually accomplished over intervals up to one day but in some cases applications over up to ten days could be realized. The underlying problem consists in an insufficient functional biostability which is a function of biocompatibility and size of the sensor, of its sterility, and of the permanent skin penetration. The latter is still required to get the device in place, to keep it in function, and to make use of the data under any condition.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?

Amperometric glucose oxidase/hydrogen peroxide sensors were inserted subcutaneously into the neck of normal and diabetic dogs (n = 10), to elucidate the conditions for stable long-term functioning. Their output current was observed in parallel with measurements of plasma glucose concentrations and their function was checked by means of induced alterations in glycaemia. After between 14 and 96 h the experiments were terminated due to losses in the apparent sensitivity of implanted sensors and/or increasing oscillations following stable measurements. This was accompanied by an inflammatory reaction which was analysed on the basis of the clinical picture and histology. In most cases there was a bacterial ingrowth from the normal skin flora of dogs. The inflammatory exsudate contained only 23 +/- 17% of the simultaneous steady state plasma glucose concentration, which was significantly different from the glucose level in the fluid obtained from non-irritate subcutaneous tissue (95 +/- 12%, separate set of experiments). The in vitro calibration of sensors exhibited essentially comparable sensitivities before and after the in vivo application. No differences in reported findings related to the biomaterials used (polyurethane versus cellulose acetate), the presence of diabetes, the history of individual electrodes and the effective duration of a given experiment were discernible. We conclude that the functional bioinstability of subcutaneous glucose sensors is largely due to the inflammatory tissue reaction which alters the effective glucose concentration within the measuring compartment of the electrodes; these drawbacks may be overcome by further miniaturization including implantable telemetric devices allowing the closure of the skin.

Animals↗

Artificial connection between glucose sensing and insulin delivery: implications of peritoneal administration.

The replacement of insulinogenic function in insulin-dependent diabetes has to restore the feedback between intracorporal glucose and insulin. This has been accomplished by the following approaches: (a) the so-called open-loop insulin treatment by means of injections or pumps, employing laboratory or other extracorporal analytical devices and closing the feedback at large intervals only; (b) transplantation of insulin producing tissue and the bioartificial pancreas, employing the natural beta-cell both for glucose sensing and insulin delivery; (c) implanted artificial drug delivery systems providing chemical feedback between intracorporal glucose and insulin release from a nonrefillable reservoir of limited capacity; (d) the intracorporal or paracorporal artificial beta-cell comprising a glucose sensor (electrochemical or other type) that permanently delivers the signal to the computer-controlled insulin pump. This artificial device works on the basis of an algorithm of glucose-dependent insulin provision, compensating for the lack of other regulators, for the site of insulin administration, which is usually posthepatic, and for the kinetic properties of sensing system, e.g., a subcutaneous inserted amperometric electrode. Present experimental studies show that the pharmacodynamics of peritoneally applied insulin may be implemented into a mathematical model of the overall glucose-insulin system. They include absorption nearly as fast as after intravenous application, predominant portal inflow and approximately 30% hepatic removal. Feedback-controlled peritoneal insulin administration by means of an artificial beta-cell working on peripheral-venous blood glucose monitoring results in normal glycemic profiles under basal conditions and during oral glucose loads, if the pharmacodynamic properties of the peritoneal route are implemented into the insulin dosage algorithm.

Algorithms↗

Implantable glucose sensors: comparison between in vitro and in vivo kinetics.

This study was aimed at validating the in vitro estimated response characteristics of implanted glucose oxidase/H2O2 electrodes with respect to their in vivo function. Monoexponential non-linear regression analysis of sensor current vs. time curves in response to square alterations in glucose concentration gave response times T95 of between 1 and 5 min. Non-primed glucose infusions were applied to dogs with these electrodes implanted subcutaneously. The simultaneously monitored in vivo data were subjected to non-linear regression analysis. The time constants T of increases or decreases after starting or ending the glucose load were (mean +/- SEM) 53 +/- 10 and 26 +/- 4 min (significant difference, p less than 0.05) in sensor current, 28 +/- 8 and 15 +/- 2 min (NS) in whole blood, and 26 +/- 5 and 18 +/- 2 min (NS) in plasma. The in vivo kinetic patterns of sensors were not related to their in vitro response times. Non-linear regression analysis of in vitro responses of glucose sensors under clearly defined conditions is recommended as a basis for further studies. The physiological delay in the subcutaneous glucose system needs more attention in this field of research.

Animals↗