Search PubMed⌕ Search

Biomedical subjects

K Ravi

Publications and source records attributed to K Ravi.

61 records · Page 4Linked to original sources

Effect of epicondylectomy in early ulnar neuritis treated with steroids.

Sixty-two ulnar nerves belonging to 44 patients with early neuritis were studied to assess the benefits offered by medial epicondylectomy and external decompression in addition to steroid therapy. The patients were randomly allocated to the surgical or the medical group. In those cases where there was bilateral involvement, surgery was carried out only on one side. All cases were assessed prior to treatment, and at predetermined intervals following treatment. This study presents the results after a 12-month follow-up. There was statistically significant improvement in both groups following treatment as assessed by improvement in motor and sensory functions and in the reduction of pain and tenderness. The study, however, failed to demonstrate any added benefit with surgical intervention as compared to steroid therapy alone in the treatment of early ulnar neuritis.

Acetaminophen↗

Characterization of dolichol and dolichyl phosphate phosphatase from soya beans (Glycine max).

A series of polyprenols, ranging in length from 15 to 22 isoprene units, has been isolated from soya beans (Glycine max) and purified by high-pressure liquid chromatography. N.m.r., i.r. and mass spectra of the compounds indicated that they are alpha-saturated polyprenols of the dolichol type. The amount present in dry seeds was about 9 mg/100 g, whereas dolichyl phosphate (Dol-P) was present only in trace amounts. Dol-P phosphatase activity was detected in the microsomal fraction of 5-day-old germinating soya-bean cotyledons. The Dol-P phosphatase activity was linear with respect to time and protein concentration and exhibited a broad pH optimum (pH 7-9). Triton X-100 was necessary for significant enzyme activity. Enzyme activity was slightly enhanced by EDTA, whereas dithiothreitol was without effect. An apparent Km of 5 microM was determined for Dol-P. Bivalent metal ions were not required for enzyme activity. A number of phosphorylated compounds tested as enzyme substrates (including a number of nucleoside phosphates, glucose 6-phosphate, sodium beta-glycerophosphate and Na4P2O7) did not compete with [1-3H]Dol-P as substrate. A number of phospholipids were also tested for their ability to act as Dol-P phosphatase substrates. At 1 mM concentration, phosphatidylcholine, phosphatidylethanolamine, phosphatidic acid and lysophosphatidic acid each inhibited enzymic activity. However, at 0.1 mM concentration, phosphatidylcholine and phosphatidylethanolamine were slightly stimulatory, whereas phosphatidic acid and lysophosphatidic acid were still inhibitory. Phosphatidic acid showed competitive inhibition.

Chromatography, High Pressure Liquid↗

Effect of carbon dioxide on the activity of slowly and rapidly adapting pulmonary stretch receptors in cats.

Single fiber activity from slowly and rapidly adapting pulmonary stretch receptors (PSR) was recorded from the left cervical vagus of anesthetized, open-chested and artificially ventilated cats. Reducing the end-tidal CO2 to low values did not affect the frequency of occurrence of higher threshold (HT) PSR. Occlusion of the left pulmonary artery (LPA) had no significant effect on the resting discharge of both HT and low threshold (LT) PSR. Cyclic ventilation with 8% CO2 in O2 reduced the activity of LT and HT receptors by similar amounts, irrespective of their anatomical location. After LPA occlusion, CO2 ventilation reduced markedly the activity of both type of PSR but to the greatest extent that of the HT receptors, the majority of which were located in the intrapulmonary airways. The CO2 depressant effect may not be due solely to changes in H+ concentration at the receptor level, since acetazolamide did not totally abolish the effect even though it significantly reduced it. Sustained inflation with 8% CO2 in O2 significantly reduced the activity of HT receptors in both the dynamic and static phases of inflation, but had no effect on the activity of LT receptors. Direct localization showed that the receptors which were more accessible to CO2 (all HT and one LT) were located in the lung parenchyma. In the case of rapidly adapting receptors, sustained inflations with CO2 gave inconsistent results. The results show clearly that, as in other mammalian species, the PSR activity in cats is also reduced by hypercapnia. The present study stresses the importance of localizing the PSR and making the observations separately on the two types of PSR, for there may be qualitative and quantitative differences.

Acetazolamide↗

Treatment planning dosimetric parameters for a (90)Y coil source used in intravascular brachytherapy.

BACKGROUND: (90)Y coil sources have been used in animal and clinical trials for treatment of restenosis in intravascular brachytherapy (IVBT). This study aims to determine the American Association of Physicists in Medicine (AAPM) Task Group-60 (TG-60) dosimetric quantities in regions surrounding the balloon wall for use in treatment planning computer systems. METHODS: The Monte Carlo method was used to determine the dose distribution, using MCNP4B2 code. The coil source was modeled by a hollow cylinder of 2.9 cm length centered in a balloon (2.5 mm diameter) filled with carbon dioxide (CO(2)) at 5 atm. Scoring voxels consisted of contiguous annular disk shells with 0.1 mm spacing in the radial direction and 0.2 mm spacing in the longitudinal direction. The scoring region ranges from the center of the source to 1.0 cm in the longitudinal direction, and from 0.13 to 1 cm in the radial direction. In the plane containing the source axis, the Monte Carlo-generated doses in rectilinear coordinates are converted to polar coordinates. RESULTS: The dose rate of the source is provided in both Cartesian and polar coordinates. The dose rate constant [D(r(0),theta(0))], anisotropy function [F(r,theta)], and radial dose function [g(r)] were generated from these values and listed in tabular format. At shallow angles and longer distances from the source center, large values of the anisotropy function resulted, deviating two orders of magnitude from unity. CONCLUSIONS The doses given to the intima, media, and adventitia are very crucial quantities in IVBT. The calculated TG-60 dosimetric quantities, used commonly in conventional brachytherapy applications, provide a means for the user to determine the three-dimensional dose surrounding the balloon catheter. These parameters can be used in future treatment planning system for IVBT. We also discuss the need to develop a new formalism specific to longer sources used in IVBT.

Angioplasty, Balloon, Coronary↗

Ytterbium-169: a promising new radionuclide for intravascular brachytherapy.

PURPOSE: To explore the feasibility of 169Yb (gamma, 93 keV) as a new radionuclide for intravascular brachytherapy (IVBT) in terms of dose distribution, penetration power, and radiation safety features as compared with 125I and 192Ir. METHODS: The dose distributions for catheter-based sources, 169Yb, 125I, and 192Ir, in homogeneous water and in the presence of calcium and a steel stent have been determined and compared using the Monte Carlo method (MCNP4B2 code). The dose rates of the sources were evaluated from 0.02 to 100 cm. RESULTS: In the short distance range (0.02<r<1.0 cm), the dose distributions in homogeneous water are very similar for the three radionuclides when the dose rates are normalized at 2 mm. Between 1 and 20 cm, the relative dose rates fall off similarly for 169Yb and 192Ir, whereas for 125I, it decreases much more rapidly. At a distance further away (r approximately 100 cm), the dose rate of 169Yb is about 10 times lower than that of 192Ir, indicating the cathlab radiation shielding requirement for 169Yb is substantially reduced as compared with 192Ir. Calcified plaques and stents cause a drastic dose reduction in the arterial wall for 125I, but have no effect for 192Ir gamma-rays. Only slight dose reductions were detected for 169Yb beyond a layer of 1.0-mm calcium (2-3%), and behind a steel stent strut (5%). CONCLUSION: 169Yb is a promising new radionuclide for IVBT. It has a much better penetrating power through calcified plaques and stents compared with the low-energy source 125I. It also provides easier radiation protection measures for cardiac cathlab personnel than the high-energy source 192Ir, while preserving a favorable dose distribution in tissues surrounding an arterial vessel.

Brachytherapy↗

Effect of stent on radiation dosimetry in an in-stent restenosis model.

PURPOSE: Intravascular brachytherapy is the leading modality being evaluated for treatment of in-stent restenosis. Stent struts may have an effect on the dose distributions of various radiation sources. We evaluated dosimetry in a stented coronary artery model using a variety of beta and gamma sources and stent materials. METHODS: We determined the dose distributions with and without stent in the in-stent restenosis model. Three beta-particle emitting radionuclides, 90Y (2.3 MeV), 144Pr (3.0 MeV), and 106Rh (3.5 MeV), and two gamma-ray emitters, 192Ir (380 keV) and 125I (30 keV), were studied. Stent materials included stainless steel, nitinol, and tantalum. Monte Carlo dose calculations were performed in a stent model of multiple stent struts placed at 1.5 mm from the source. Isodose curves were generated and the ratios of dose rates with and without stent, the stent factors, were evaluated. A stent factor of greater or less than unity represents dose enhancement or reduction in the presence of a stent. RESULTS: For the three beta radionuclides, dose reduction was found on the adventitial side of the stent strut and dose enhancement was noted on the luminal side. On the luminal side, the maximum dose enhancement ranges from 7% to 29%, and the dose reduction on the adventitial side ranges from 13% to 43%. Both the reduction and enhancement effects were most pronounced for the high atomic number material, tantalum. For a given stent material, the dose reduction and enhancement are similar for the three beta radionuclides. For the gamma sources, the stent had no effect for the high-energy 192Ir, but for the low-energy 125I, drastic dose reduction on the adventitial side was observed (up to 86% for tantalum stent), and about 10% dose enhancement on the luminal side was also noted. The dose reduction with 125I was more pronounced than that seen with the beta sources. CONCLUSIONS: The presence of stent struts significantly affects dose distributions of 90Y, 106Rh, 144Pr, and 125I. The maximum dose reduction can be as much as 86%. 192Ir was unaffected. These factors need to be considered in choosing radionuclides and dose prescriptions in treating in-stent restenosis.

Brachytherapy↗