Search PubMed⌕ Search

Biomedical subjects

K R Thulborn

Publications and source records attributed to K R Thulborn.

62 records · Page 4Linked to original sources

Uptake of n-(9-anthroyloxy) fatty acid fluorescent probes into lipid bilayers.

A description in thermodynamic terms is given of ligand-membrane interaction which may occur by either or both a binding and a partition process. Results obtained by fluorescence enhancement and polarization techniques on the uptake of n-(9-anthroyloxy) fatty acids by phospholipid bilayers are analysed to show that binding rather than partition effects primarily determine the extent of probe uptake. Liposome concentration-dependence effects are also reported which required that binding results obtained with different probes be compared at fixed lipid concentrations. On this basis it is concluded that as the separation of the anthracene and carboxyl groups within the fatty acid molecule is increased, and hence as the anthracene group moves deeper into the bilayer, the fluorescent probe is bound to the bilayer with greater affinity but is accepted by fewer binding sites within the membrane. Studies on probe uptake at high ionic strength and into negatively charged bilayers indicate that hydrophobic rather than electrostatic interactions make the dominant contribution to the free energy of binding.

Fatty Acids↗

High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.

Known specialized properties of the human visual cortex have been used to investigate the role of spatial resolution on fMRI using blood oxygenation level dependent (BOLD) echo-planar MRI at 3.0 tesla. The magnitude of BOLD signal changes has been examined at low (3.1 x 3.1 x 3.0 mm3) and high (0.8 x 1.6 x 3.0 mm3) resolution using both gradient-echo and spin-echo EPI. Paradigms were designed to activate primary visual cortex (V1/V2) and more specialized areas associated with detection of color (V4) and motion (V5). Sensitivity of activation maps increased at higher resolution despite the decreased total signal intensity at the smaller voxel size, presumably from reduced partial volume averaging. The greater microvascular selectivity of high-resolution spin-echo imaging enabled distinct activation patterns sensitive to motion to be detected in V1/V2 that were not apparent with gradient-echo imaging. The spatial resolution at 3.0 tesla was constrained by the size of physiological head motion relative to the voxel dimensions rather than SNR or the hemodynamic response of BOLD contrast. The higher spatial resolution at 3.0 tesla with more selective spin-echo EPI can further refine functional mapping within the cerebral cortex.

Brain Mapping↗

Dorsal cortical regions subserving visually guided saccades in humans: an fMRI study.

Neurophysiological studies in non-human primates have identified saccade-related neuronal activity in cortical regions including frontal (FEF), supplementary (SEF) and parietal eye fields. Lesion and neuroimaging studies suggest a generally homologous mapping of the oculomotor system in humans; however, a detailed mapping of the precise anatomical location of these functional regions has not yet been achieved. We investigated dorsal frontal and parietal cortex during a saccade task vs. central fixation in 10 adult subjects using functional magnetic resonance imaging (fMRI). The FEF were restricted to the precentral sulcus, and did not extend anteriorly into Brodmann area 8, which has traditionally been viewed as their location in humans. The SEF were located in cortex along the interhemispheric fissure and extended minimally onto the dorsal cortical surface. Parietal activation was seen in precuneus and along the intraparietal sulcus, extending into both superior and inferior parietal lobules. These findings localize areas in frontal and parietal cortex involved in saccade generation in humans, and indicate significant differences from the macaque monkey in both frontal and parietal cortex. These differences may have functional implications for the roles these areas play in visuomotor processes.

Adult↗

The role of ferritin and hemosiderin in the MR appearance of cerebral hemorrhage: a histopathologic biochemical study in rats.

A rat model of cerebral hemorrhage using stereotaxic injection of blood into the right basal ganglia was developed to investigate the influence of iron metabolism on the appearance of cerebral hemorrhage on MR images. Images of in vitro fixed brain sections stained specifically for different iron-storage substances, ferritin and hemosiderin, created by digitization of the pathology sections using an Eikonix CCD camera, were compared with the in vivo MR images of late-phase hematomas. Areas of the pathologic and MR features of the lesions were quantitatively correlated. The single-slice MR images were obtained with the use of T1- and T2-weighted spin-echo pulse sequences, as well as T2-weighted spin-echo pulse sequences in which the 180 degrees refocusing pulse was offset from the center of the echo time; this was termed an asymmetric spin-echo pulse sequence. The symmetric and asymmetric T2-weighted images allowed the calculation of line-width images, which emphasize line broadening from intravoxel magnetic field inhomogeneities that arise from the presence of iron-containing substances. From biochemical and histochemical staining, we conclude that at least two iron-storage substances are present in the late phase of resolving cerebral hematomas. Ferritin has a wider distribution than hemosiderin, showing a similar distribution to the MR signal changes of the calculated line-width images. Line-width mapping is a sensitive means of detecting magnetic field inhomogeneities caused by the magnetic susceptibility differences introduced by the aggregation of these iron-storage substances.

Animals↗

MR quantification of cerebral ventricular volume using a semiautomated algorithm.

PURPOSE: A semiautomated border identification algorithm, insensitive to user bias, is evaluated for accuracy and speed in the measurement of ventricular volumes from three-dimensional MR images. METHODS: A three-dimensional gradient-echo technique was implemented on a Signa clinical imaging system. Data from phantoms and patients were analyzed for volume using a segmentation algorithm designed with: 1) correction for partial volume averaging; 2) insensitivity to user bias; and 3) speed. Accuracy, precision, and intra- and interobserver variability were determined. RESULTS: Average error for phantom studies was 4% to 6%, or 1 to 2 cc across the volumes, which ranged from normal to mild hydrocephalus (< 60 cc). Patient studies showed intra- and interobserver error of 2.3% and 7.8%, respectively. The correction for partial volume averaging resulted in a threefold decrease in error. Data were acquired and reconstructed within 7 minutes. Experienced radiologists required less than 15 minutes to perform each analysis. CONCLUSIONS: This algorithm allows accurate measurement of ventricular volumes in an efficient, minimally supervised manner.

Adult↗