Rationale for the application of thin, continuous metal films in high magnification electron microscopy.

Various metal films of different thicknesses were deposited on to a particle test specimen and their effects on topographic contrast generation and specimen preservation were determined. Tobacco mosaic virus adsorbed on to thin carbon supports or silicon chips was imaged in TEM or high resolution SE-I SEM at a magnification of 350,000X. Tantalum films of 1-2 nm (average mass) thickness produced best contrasts and prevented volume loss of the particles from electron beam damage. Excessively thick films of 5-10 nm thickness blanketed fine structures and caused severe volume losses. Discontinuous 2 nm thick films of gold or platinum decorated the surfaces, caused a loss in topographic contrasts and induced very high volume losses. Thin continuous metal films were necessary to generate high topographic contrast and to prevent volume loss from beam damage by providing sufficient mechanical stability for small topographic features and increased thermal conductivity of the specimen surface.

Ferritins↗

Endothelial plasmalemmal vesicles have a characteristic striped bipolar surface structure.

Capillary endothelial cells have a large population of small (65-80 nm diameter in transmission electron microscopy) vesicles of which a large fraction is associated with the plasmalemma of the luminal and abluminal side. We studied the fine structure and distribution of these plasmalemmal vesicles by high resolution scanning electron microscopy in cultured endothelial cells obtained from bovine adrenal cortical capillaries. Cell monolayers were covered with polylysine-coated silicon chips, split in high potassium buffer, fixed in aldehyde mixtures, and then treated with OsO4 and thiocarbohydrazide. After critical point drying, the specimens were coated with a thin (less than 2 nm) continuous film of chromium. On the cytoplasmic aspect of the dorsal plasmalemmal fragments seen in such specimens, plasmalemmal vesicles appear as uniform vesicular protrusions approximately 70-90 nm in diameter, preferentially concentrated in distinct large fields in which they occur primarily as single units. Individual plasmalemmal vesicles exhibit a striped surface fine structure which consists of ridges approximately 10 nm in diameter, separated by furrows and oriented as meridians, often ending at two poles on opposite sides of the vesicles in a plane parallel to the plasmalemma. This striped surface structure is clearly distinct from the cage structure of coated pits found, at low surface density, on the same specimens. The cytoplasmic aspect of the plasmalemma proper is covered by a fibrillar infrastructure which does not extend over plasmalemmal vesicles but on which the latter appear to be anchored by fine filaments.

Adrenal Cortex↗

Working at higher magnifications in scanning electron microscopy with secondary and backscattered electrons on metal coated biological specimens and imaging macromolecular cell membrane structures.

Membrane structures of macromolecular dimensions were imaged with high resolution secondary electron type I (SE-I) signal contrasts on metal coated biological specimens. The quality of the surface information was strongly dependent on the signal used for microscopy and on the properties of metal films, i.e., thickness, continuity, structure and decoration effects. Films of 10 nm thickness produced so much type II electrons that identical images were obtained with the conventional SE-II and BSE-II signals. In such images, the type I SE signal was so low that only very weak contrasts were recognizable. If the films--continuous or discontinuous--were composed of large metal aggregates (gold and platinum) a strong micro-roughness contrast was produced by the type II signal. At high magnifications (100,000 x) this background signal greatly reduced the S/N ratio of the SE-I signal. A similar effect was previously shown to be produced by the type III background signal. The type II background signal minimized when continuous films of small aggregates (tantalum and chromium) were applied. SE-I contrast dominated in the image if the film thickness was limited to 1 nm. Additionally, it was found that gold and platinum decorated membrane surface structures, less than 20 nm in size, and did not reveal all the topographic information available (size, shape, orientation spacing of small surface features) but merely displayed center-to-center distances. These decoration effects were avoided and extensive topographic information was obtained through surface coating with Ta or Cr.

Animals↗

Potassium supplementation in ritodrine-induced hypokalemia.

Acute hypokalemia occurs during infusion of beta 2 agonists for tocolysis. This study examines the efficacy of supplemental potassium in treating this hypokalemia. Four groups of dogs were anesthetized and given lactated Ringer's solution (group I), potassium chloride (group II), ritodrine hydrochloride (group III), and ritodrine plus potassium (group IV). Arterial blood gases, pH, and serum and urinary electrolytes were measured. Results were analyzed by an analysis of variance. Serum potassium fell in groups I and III, rose in group II, and remained stable in group IV. Urinary potassium levels in groups that received ritodrine (III and IV) were not different from control levels. Potassium given with ritodrine will prevent hypokalemia. However, the risks of hyperkalemia exist if vigorous replacement is undertaken. There were no dysrhythmias and no adverse effects in any of the hypokalemic animals. Therefore, the routine administration of potassium is not advocated even in obstetric patients who undergo general anesthesia.

Animals↗

Fine structure of a periciliary ridge complex of frog retinal rod cells revealed by ultrahigh resolution scanning electron microscopy.

We studied the junctional region between rod inner segments (RIS) and outer segments (ROS) in frog retinas by high resolution scanning electron microscopy (SEM). Retinas of dark adapted or light exposed Rana pipiens were critical-point-dried and RIS and ROS were split and coated with ultrathin metal films of niobium and chromium--or decorated with gold--and imaged in a new SE-I imaging mode. The connecting cilium (CC) usually broke at the base of the RIS and remained attached to the ROS. The outer part of the CC plasmalemma expanded to form liplike protrusions beyond which disks evaginated with successively larger diameter until they reached the full width of the ROS. The CC rose out from an invagination of the RIS apical plasma membrane (PM). On the lateral walls of this invagination, a highly ordered complex of nine symmetrically arrayed ridges and grooves rose steeply and extended laterally approximately 0.4-1 micron on the adjacent RIS PM. On the apical plasmalemma, the ridges and grooves formed groups of three to four parallel rows that surrounded the invagination. The grooves were bridged by filaments anchored at the top edges of the ridges. This highly ordered structure we term the periciliary ridge complex (PRC). Its ninefold symmetry apparently reflects the 9 + 0 microtubule organization of the CC axoneme. The three-dimensional structure revealed by SEM was confirmed by transmission electron microscopy (TEM) of sections of Epon-embedded retinas. TEM-immunocytochemistry on thin sections of retinas embedded in glutaraldehyde cross-linked albumin suggested that the PRC and the CC may participate in opsin transport and disk morphogenesis.

Animals↗

Conditions required for high quality high magnification images in secondary electron-I scanning electron microscopy.

High quality of secondary electron (SE) images, taken at useful magnifications of 100,000 to 200,000, require new signal generation and collection methods and new metal coating procedures. High quality is defined as the condition under which image contrast describes accurately the topographic features of the specimen in a size range that approximates the beam diameter. Such high resolution contrasts are produced by the SE (SE-I) generated by a small electron probe on the specimen surface. Tobacco mosiac virus and ferritin molecules deposited on bulk substrates were introduced as test specimens to check the image quality obtained. The SE-I signal contrast could be imaged when SE (SE-III), produced by backscattered electrons (BSE) at the pole piece of the final lens, were eliminated with an electron absorption device attached to the pole piece. This signal collection procedure will be referred to as "Secondary Electron-I Image" (SE-I image) mode. In addition to the SE-III, BSE generate SE-II in the specimen itself. On specimens deposited on bulk gold or platinum, and coated with the same metals SE-II produced a microroughness contrast that limited particle resolution in the SE-I image mode to approximately 10 nm. Reduction of SE-II and enrichment of the signal in SE-I was achieved by using continuous fine crystalline coatings of tantalum, niobium and chromium. By applying these metals in films of approximately 2.0 nm thickness, the SE-I contrast generation was found to be indepedent of the atomic number of the metal. Edge sharpness was improved when the specimens were coated with low atomic number metals. Under these conditions, the quality of images obtained in SE-I image mode equals that of images obtained in TEM from identically coated specimens and was limited only by the size of the topographic details, beam diameter and beam current.

Ferritins↗

Application of a general equation for controlled pore glass permeation chromatography to an aggregating. Spherical virus.

A semi-empirical permeation chromatography equation relating pore size, species size and elution coefficient, which had previously been derived from chromatographic data of narrow-molecular-weight dextrans on controlled pore glass, was applied to the chromatography of an aggregating virus particle. A large number of chromatographic runs on columns of different pore sizes were combined and statistically evaluated. The resulting diameter distribution versus infectivity curve for the virus particle population shows distinct maxima at multiples of 50 nm. This unit size agrees with electron microscopical observations and confirms the applicability of the chromatography equation.

Chromatography↗

Improved handling of structural fragile cell-biological specimens during electron microscopic preparation by the exchange method.

An exact method of preparation of soft biological specimens for electron microscopic analysis of surface fine structures is described. It allows routine preparations of fragile specimens for SEM and TEM imaging modes. With this procedure physical preparation parameters such as mechanical loads on the specimen surface or changes of temperature are controlled. The wet specimens are premounted in cheap disposable BEEM-containers or glass boats and are constantly kept under liquid in a closed system. The exchange of preparation media is performed continuously and, if necessary, over gradients. For comparative investigations with different EM-modes, at each step of the procedure parts of the specimens may be removed for individual processing. Conventionally prepared critical-point dried specimens are compared to those processed by the exchange technique and preservation of surface fine structures is demonstrated. Shadow-casted clathrin cages and stereo-replicas of virus infected cell cultures are shown in TEM preparations. For SEM, coverslip cell cultures and isolated glomerulus basement membranes are prepared and an additional flat embedding for TEM ultrathin sections is demonstrated.

Basement Membrane↗

Scanning electron microscopy at macromolecular resolution in low energy mode on biological specimens coated with ultra thin metal films.

In this report, conditions for attaining high resolution in scanning electron microscopy with soft biological specimens are described using the currently available high resolution scanning electron microscopes in emission mode of low energy electrons (secondary and charging electrons). Retinal rod outer segments, red blood cells, intestinal mucosa, and ferritin molecules were all used as biological test specimens. From uncoated specimens a new source of signal, referred to as a discharge signal, can provide a high yield of low energy electrons from an excitation area approximately the size of the beam's cross section. Additionally, under these conditions sufficient topographic contrast can be achieved by applying ultra thin metal coatins. A 0.5 nm thick gold film is found sufficient for generating the total signal, whereas increased coating thickness causes additional topographic background signal. However, a 2.0 nm film is needed for imaging surface details with the present instrument. Ultra thin, even, and grainless tantalum films have been found effective in eliminating the charging artifacts caused by external fields, and the decoration artifacts caused by crystal growth as seen in gold films. To improve, in high magnification work on ultra thin coated specimen, signal-to-noise ratio, methods for obtaining saturation of the signal with discharge electrons are shown. The necessity of confirming the information obtained in SEM by independent techniques (TEM of stereo-replicas or ultra thin sections) is discussed.

Animals↗

Derivatized silica spheres as immunospecific markers for high resolution labeling in electron microscopy.

For high resolution labeling of influenza virus cell surface antigens on HeLa cells, an immunospecific marker is used with silica sphere cores of 13--14 nm average diameter. These markers are formed using commercially available silica sphere sols. Two other size ranges are available, 7--8 nm and 22--25 nm. The steps for chemical derivatization are described in detail. Amino and aldehyde functions are covalently introduced onto the sphere surface. Sols of these derivatized silica spheres (DSS) are physicochemically stable and therefore usable for years. Coupling of IgG to DSS followed by permeation chromatography on controlled pore glass results in size-defined immunospecific silica sphere markers (DSS-markers). Saturation labeling of cell surface antigens on HeLa cells on cover slips is obtained with the final sphere concentration of 10(14) DSS-marker/cm3 within 20 min. With usual protective conditions, the marker stability and labeling ability are preserved for months. The visibility and the fine structure of the DSS-marker on cell surfaces are shown by using transmission electron microscopy (TEM) with stereo replicas and ultrathin sections.

Antigens, Surface↗

[Comparative light and scanning electron microscopic studies of the human gingiva by means of the filter imprint method].

The structure of the mucosal surface can be reproduced almost unchanged by the filter imprint method. Scan electronmicroscopic investigations of the tissue surface and the surface cells removed by the imprint technique demonstrate that only the uppermost cell layer is removed and that these cells retain their layer distribution, form and fine surface structure. It is therefore possible to describe the cells in the print morphologically by light microscopy and to characterize them functionally by differential staining.

Gingiva↗