Search PubMedSearch

Biomedical subjects

K R Foster

Publications and source records attributed to K R Foster.

At least 19 recordsLinked to original sources

Microwave radiometry in biomedicine: a reappraisal.

Nearly 20 years ago the first papers appeared on biomedical applications of microwave radiometry, and many other papers have since appeared. Yet, despite its unique capabilities, microwave radiometry has so far received only limited acceptance by the medical community, and little commercial success. The chief reasons, we suggest, are the shallow depth of sensing and the difficulty of extracting imaging information from radiometry signals emitted by electrically heterogeneous media. A secondary factor has been the difficulty of validating many proposed clinical applications for the method--in particular, cancer detection. We suggest that microwave radiometry is a viable method of thermal sensing, but its successful applications are likely to be quite different than those that were originally conceived for the technique.

Extravasation of Diagnostic and Therapeutic Materi

Health effects of low-level electromagnetic fields: phantom or not-so-phantom risk?

The possibility of subtle hazards from weak nonionizing electromagnetic fields (EMFs) has been controversial for many years, shifting over a range of issues without resolution. The confusion arises partly from the weak evidence for hazard and partly from the inconsistent and speculative nature of some of the bioeffects literature. More attention is needed to define ways to resolve the issues.

Abnormalities, Radiation-Induced

Microwave radiometry in living tissue: what does it measure?

The sensitivity of microwave radiometry for detecting subcutaneous targets was studied both experimentally and theoretically. The radiometer used a dielectric loaded rectangular waveguide antenna in contact with a lossy dielectric medium. A cylindrical target with dielectric properties and/or temperature different from that of the surrounding medium was located beneath this surface. For most of the studies, the target and the surrounding medium were maintained at constant, but unequal, temperatures (i.e., heat conduction effects were insignificant). The received radiometric signal was calculated as the location and dielectric properties of the target were varied. Finally, the radiometer signal was calculated for the situation with the target maintained at constant temperature but with the surrounding medium modeled by the bioheat equation. Experimental studies were performed using a radiometer operating at 4.7 GHz. The target was a thin walled tube through which a temperature controlled liquid was circulated, located in a temperature controlled fluid tank. The results indicate that microwave radiometry (as used in this study) responds to the temperature averaged over the field pattern of the antenna with very strong weighting of regions near the surface. A simple quasi-static analysis provides a good indication of the sensitivity of the technique for detecting cylindrical targets whose dielectric properties are different from those of the surrounding medium. A simple estimate of thermal conduction around the target suggest that thermal effects greatly increase the apparent size of the target.

Electromagnetic Phenomena

Dielectric properties of tissues and biological materials: a critical review.

We critically review bulk electrical properties of tissues and other biological materials, from DC to 20 GHz, with emphasis on the underlying mechanisms responsible for the properties. We summarize the classical principles behind dielectric relaxation and critically review recent developments in this field. Special topics include a summary of the significant recent advances in theories of counterion polarization effects, dielectric properties of cancer vs. normal tissues, properties of low-water-content tissues, and macroscopic field-coupling considerations. Finally, the dielectric properties of tissues are summarized as empirical correlations with tissue water content in other compositional variables; in addition, a comprehensive table is presented of dielectric properties. The bulk electrical properties of tissues are needed for many bioengineering applications of electric fields or currents, and they provide insight into the basic mechanisms that govern the interaction of electric fields with tissue.

Adipose Tissue

"Resonances" in the dielectric absorption of DNA?

An attempt was made to confirm previous reports of resonant-like dielectric absorption of plasmid DNA in aqueous solutions at 1-10 GHz. The dielectric properties of the sample were measured using an automatic network analyzer with two different techniques. One technique used an open-ended coaxial probe immersed in the sample; the other employed a coaxial transmission line. No resonances were observed that could be attributed to the sample; however, resonance-type artifacts were prominent in the probe measurements. The coaxial line technique appears to be less susceptible to such artifacts. We note two important sources of error in the calibration of the automatic network analyzer using the probe technique.

DNA, Bacterial

Perfused phantom models of microwave irradiated tissue.

The theoretical basis, practical design considerations, and prototype testing of a perfused model suitable for simulation studies of microwave heated tissue are presented. A parallel tube heat exchanger configuration is used to simulate the internal convection effects of blood flow. The global thermal response of the phantom, on a scale of several tube spacings, is shown theoretically to be nearly identical to that predicted by Pennes' bioheat equation, which is known to give a reasonable representation of tissue under many conditions. A parametric study is provided for the relationships between the tube size, spacing and material properties and the simulated perfusion rate. A prototype with a physiologically reasonable perfusion rate was tested using a typical hyperthermia applicator. The measured thermal response of the phantom compares favorably with the numerical solution of the bioheat equation under the same irradiation conditions. This similarity sheds light on the unexpected success of the bioheat equation for modeling the thermal response of real tissue.

Blood Circulation

Small-scale temperature fluctuations in perfused tissue during local hyperthermia.

We develop analytical expressions (scaling laws) for the local temperature fluctuations near isolated and countercurrent blood vessels during hyperthermia. These scaling laws relate the magnitude of such fluctuations to the size of the heated region and to the thermal equilibration length of the vessels. A new equilibration length is identified for countercurrent vessels. Significant temperature differences are predicted between the vessels and the immediately adjacent tissue when the equilibration length is comparable to or longer than the size of the heated tissue region. Countercurrent vessels are shown to have shorter equilibration lengths and produce smaller temperature fluctuations than isolated vessels of the same size.

Blood Vessels

Heat transport mechanisms in vascular tissues: a model comparison.

We have conducted a parametric comparison of three different vascular models for describing heat transport in tissue. Analytical and numerical methods were used to predict the gross temperature distribution throughout the tissue and the small-scale temperature gradients associated with thermally significant blood vessels. The models are: an array of unidirectional vessels, an array of countercurrent vessels, and a set of large vessels feeding small vessels which then drain into large vessels. We show that three continuum formulations of bioheat transfer (directed perfusion, effective conductivity, and a temperature-dependent heat sink) are limiting cases of the vascular models with respect to the thermal equilibration length of the vessels. When this length is comparable to the width of the heated region of tissue, the local temperature changes near the vessels can be comparable to the gross temperature elevation. These results are important to the use of thermal techniques used to measure the blood perfusion rate and in the treatment of cancer with local hyperthermia.

Biomechanical Phenomena

Dielectric properties of low-water-content tissues.

The dielectric properties of two low-water-content tissues, bone marrow and adipose tissue, were measured from 1 kHz to 1 GHz. From 1 kHz to 13 MHz, the measurements were performed using a parallel-plate capacitor method. From 10 MHz to 1 GHz, a reflection coefficient technique using an open-ended coaxial transmission line was employed. The tissue water contents ranged from 1 to almost 70% by weight. The dielectric properties correlate well with the values predicted by mixture theory. Comparison with previous results from high-water-content tissues suggests that bone marrow and adipose tissues contain less motionally altered water per unit dry volume than do the previously studied tissues with lower lipid fractions. The high degree of structural heterogeneity of these tissues was reflected in the large scatter of the data, a source of uncertainty that should be considered in practical applications of the present data.

Adipose Tissue

Transport properties of polymer solutions. A comparative approach.

A variety of transport properties have been measured for solutions of the water soluble polymer poly(ethylene oxide)(PEO) with molecular weights ranging from 200 to 14,000, and volume fractions ranging from 0-80%. The transport properties are thermal conductivity, electrical conductivity at audio frequencies (in solutions containing dilute electrolyte), and water self-diffusion. These data, together with dielectric relaxation data previously reported, are amenable to analysis by the same mixture theory. The ionic conductivity and water self-diffusion coefficient, but not the thermal conductivity, are substantially smaller than predicted by the Maxwell and Hanai mixture relations, calculated using the known transport properties of pure liquid water. A 25% (by volume) solution of PEO exhibits an average dielectric relaxation frequency of the suspending water of one half that of pure water, with clear evidence of a distribution of relaxation times present. The limits of the cumulative distribution of dielectric relaxation times that are consistent with the data are obtained using a linear programming technique. The application of simple mixture theory, under appropriate limiting conditions, yields hydration values for the more dilute polymer solutions that are somewhat larger than values obtained from thermodynamic measurements.

Biological Transport