Color Doppler echocardiographic assessment of Sorin mitral prosthetic valve.

Doppler echocardiographic characteristics of 57 normally functioning Sorin prosthetic valves (a tilting valve) in the mitral position were studied in the early postoperative period. The three valve sizes (in mm) studied were: 25 (n = 15), 27 (n = 32) and 29 (n = 10). The mean gradients (mmHg) and the valve area (Sq cm) calculated by pressure half time method) for the three valve sizes were 3.46 +/- 1.69 and 2.49 +/- 0.26; 3.46 +/- 1.25 and 2.57 +/- 0.44; and 3.2 +/- 1.23 and 2.55 +/- 0.41; respectively. There was no significant difference in gradients and valve area between the three sizes, variations in pressure half time and therefore the calculated valve area was large. Color Doppler evaluation revealed a bifid nonturbulent jet directed anteriorly towards the interventricular septum. 12 patients (20%) had mild valvar and 7 (12%) had paravalvar mitral regurgitation (mild in 5 and moderate in 2) without any associated prosthetic valve dysfunction. The paravalvar regurgitation persisted in all the 5 patients restudied at 5-12 months postoperatively. Sorin prosthetic valves have similar gradients and valve area when compared to other disc valves. The incidence of of paravalvar regurgitation was slightly higher in our series. The limitations of Doppler derived gradients and area of prosthetic valve are discussed.

Adolescent↗

Stroke in young.

Explore the source record for details and available documents.

Cerebrovascular Disorders↗

Inappropriate shocks in patients receiving internal cardioverter-defibrillators for malignant ventricular arrhythmias.

Implantation of internal cardioverter defibrillators (ICDs) for treatment of malignant ventricular arrhythmias is complicated by failure of therapy or inappropriate shocks. We studied 81 patients (age range 16-72 years; mean 48 +/- 13 years) who underwent ICD implantation for device therapy. The underlying aetiology was ischaemic heart disease (39%), cardiomyopathies (32%) and others (28%). Information regarding shocks was collected using Holter monitoring, telemetry or device memory (stored electrograms) and lastly by clinical follow-up. Fifty-eight patients completed 36 months of follow-up. Thirty-five patients experienced 337 spontaneous shocks, appropriate in 21, inappropriate in 12, and both in two patients. Of the 74 episodes of inappropriate discharges for rhythms other that ventricular tachycardia (VT) or ventricular fibrillation(VF), 55 percent were due to supraventricular arrhythmias (atrial flutter or fibrillation). Lead malfunction occurred in four and the device was replaced in two. Additional drugs controlled AF in one. There was no mortality in any of the 81 patients. The frequency of shocks was highest in the first six months after implantation and atrial fibrillation remains the main cause. In conclusion, inappropriate shocks are frequent in patients undergoing ICD implantation.

Adolescent↗