Search PubMed⌕ Search

Biomedical subjects

K Nordby

Publications and source records attributed to K Nordby.

At least 19 recordsLinked to original sources

Molecular epidemiology of Salmonella spp. isolates from gulls, fish-meal factories, feed factories, animals and humans in Norway based on pulsed-field gel electrophoresis.

The molecular epidemiology of 98 isolates of Salmonella serovar Agona (n = 27), S. Montevideo (n = 42) and S. Senftenberg (n = 29) from wild-living gulls, fish-meal factories, feed factories, humans and domestic animals was investigated using pulsed-field gel electrophoresis (PFGE) and computerized numerical analysis. Two of the S. Agona profiles were identified both in gulls and in two of the factories. In addition, one of these profiles was detected in two infected poultry farms. Two of the S. Montevideo profiles were also identified both in gulls and in two of the factories, and one of these profiles was observed in a human isolate. Four factories shared an identical S. Senftenberg profile. The S. Senftenberg profile found in gulls was not identified in any other source investigated. The presence of isolates with identical PFGE profiles indicates potential epidemiological links between different factories, as well as between gulls and factories.

Animal Feed↗

Persistence of orally administered Salmonella enterica serovars Agona and Montevideo in Atlantic salmon (Salmo salar L.).

The objective of our experiments was to study the persistence and dissemination of orally administered Salmonella in smoltified Atlantic salmon. In experiment 1, salmon kept at 15 degrees C were fed for 1 week with feed contaminated with 96 most-probable-number units of Salmonella Agona per 100 g of feed and then starved for 2 weeks. Samples were taken from the gastrointestinal tract and examined for Salmonella 1, 2, 8, 9, 15, and 16 days after the feeding ended. In experiment 2, Salmonella Agona and Montevideo were separately mixed with feed and administered by gastric intubation. Each fish received 1.0 x 10(8), 1.0 x 10(6), or 1.0 x 10(4) CFU. The different groups were kept in parallel at 5 and 15 degrees C and observed for 4 weeks. Every week, three fish in each group were sacrificed, and samples were taken from the skin, the pooled internal organs, the muscle, and the gastrointestinal tract and examined for the presence of Salmonella. The results from the two experiments showed that the persistence of Salmonella in the fish was highly dependent on the dose administered. Salmonella was not recovered from any of the fish that were fed for 1 week with the lowest concentration of Salmonella. In the fish given the highest dose of Salmonella, bacteria persisted for at least 4 weeks in the gastrointestinal tract as well as, to some extent, the internal organs. The present study shows that under practical conditions in Norway, the risk of Salmonella in fish feed being passed on to the consumer of the fish is negligible.

Administration, Oral↗

Effects of moderate doses of alcohol on immediate recall of numbers: some implications for information technology.

OBJECTIVE: Moderate doses of alcohol will have detrimental effects on memory functions used in various aspects of human interaction with information technology. The need to deal with multidigit numbers while under alcohol intoxication (e.g., making telephone calls) is a reality of life. To determine these relations, the effects of alcohol on immediate ordered recall were studied in a practical number-dialing task. METHOD: Immediate ordered recall of eight-digit numbers, presented visually or auditorily, was tested in read-and-dial or listen-and-dial forced ordered recall tasks with male subjects (N = 11) under two levels of blood alcohol concentration (BrAC = 0.05% and BrAC = 0.1%) and a no-alcohol placebo control condition (BrAC = 0.0%). RESULTS: With increasing alcohol level, immediate ordered recall of whole numbers (all eight digits correct and in the right order) fell by 9% (visual presentation) and 15% (auditory presentation). No significant interaction effect between alcohol level and digit position in the number was found for visually presented numbers, while a weak, but significant, effect was found for auditorily presented numbers (most prominent at digit positions 5, 6 and 7). This is probably due to the difference in rehearsal opportunities in the two presentation modes. No significant interaction effects between alcohol level and presentation modality were found. CONCLUSIONS: The results, tailored to a practical everyday task of dialing unfamiliar eight-digit telephone numbers, show that even moderate doses of alcohol will affect the performance of an already fragile short-term memory system engaged whenever reproduction of digit strings is required.

Acoustic Stimulation↗

Is the rod visual field temporally homogeneous?

Cone vision has been shown to be temporally inhomogeneous across the visual field. In the periphery, contrast sensitivity is lower for low temporal frequencies and higher for high temporal frequencies. Here we ask a similar question for rod vision at mesopic luminances. Isolation is obtained by testing a well documented rod monochromat. We show that the rod visual field exhibits only a modest degree of temporal inhomogeneity.

Color Vision Defects↗

Rod temporal channels.

Mechanisms underlying rod temporal contrast sensitivity have been considered in terms of a fast retinal signal predominating at mesopic levels and a slower retinal signal predominating at scotopic levels. Here we use a small signal masking method, which has previously been used to delineate the cone-mediated cortical temporal channels, to investigate their rod-mediated cortical counterparts. The results suggest that there are three different rod-mediated cortical temporal channels, one which is lowpass and two which are bandpass. These mechanisms co-exist at all light levels and their relative sensitivity depend on the stimulus spatio-temporal frequency.

Color Vision Defects↗

[Access to family practitioners by telephone. A practical example of quality assurance].

A record of telephone calls in a Norwegian town (Molde) in 1987 showed that fewer inquiries were answered by general practitioners and their receptionists than by personnel in any other profession or trade. The general practitioners and the receptionists agreed on measures to improve accessibility, and more records of telephone calls were made. The measures and the process are described. At local level, a record of calls which differentiates between those answered by the providers of primary care and those answered by automatic machines seems to be a simple and useful means of quality assurance which we encourage others to apply.

Family Practice↗

Spatial integration and sensitivity changes in the human rod visual system.

1. The factor by which increment threshold rises with increasing background intensity is less if the target is small than if it is large. The difference is usually attributed to a reduction in the area over which visual signals are integrated as the visual system light adapts. Recently, however, it has been argued that the difference in slope may instead be caused by an increase in the gain of the local response function with light adaptation. 2. To test this hypothesis in the rod-driven visual system, we compared monoptic, small and large target increment thresholds, and dichoptic, large target brightness matches, measured as a function of background intensity in a typical, complete achromat, who has no cone vision. 3. The dichoptic brightness matches were made using a large target of a similar intensity to the threshold intensity of the small target. If local intensity is important, the large target brightness matching curve should be more similar to the shallow, small target threshold curve. But, if changes in spatial integration are important, the brightness matching curve should be similar to the steeper, large target threshold curve. 4. The slope of the large (1.85 deg) target increment threshold functions measured with either 200 or 50 ms test flashes were steeper than those of the small (10 min of arc) target functions by 0.10 (on logarithmic co-ordinates) or about 15%. 5. The logarithmic slopes of the dichoptic brightness curves were also slightly steeper than the small target increment functions. This is contrary to the local response (only) hypothesis, which predicts that the brightness curve should have the same slope as the small target function because the luminance of the targets in the two cases is the same. 6. We conclude that there must be a change in spatial integration in the rod visual system during light adaptation, over and above that due to local gain changes.

Adaptation, Ocular↗

Mutual rod-cone suppression within the central visual field.

Under mesopic conditions the contrast sensitivity of the central visual field is reduced as the result of a non-linear interaction between rod- and cone-mediated signals, each of which is capable of higher sensitivity in isolation. The interaction is produced only when the rod-mediated system is driven at flicker rates above 6 Hz. This finding bears upon how rod and cone signals are combined and therefore affects our interpretation of the significance of the relationship between retinal illuminance and both contrast sensitivity and temporal resolution.

Contrast Sensitivity↗

Slow and fast pathways in the human rod visual system: electrophysiology and psychophysics.

Under most conditions, increasing the intensity of a flickering light makes the flicker more conspicuous. For a light flickering at 15 times per second, however, increasing the intensity can cause the flicker to disappear before reappearing again at higher intensities [Vision Res. 29, 1539 (1989)]. This flicker disappearance or null is also evident in human electrophysiological recordings at the same intensity levels. These results point to a duality within the rod visual pathway, in which flicker signals travel through a slow and a fast pathway and then recombine at a later stage. At 15 Hz the slow rod flicker signals are delayed by half a cycle relative to the fast signals. Thus, when the two signals are recombined, they destructively interfere and diminish the perception of flicker. The dual-pathway interpretation is supported by both electroretinographic and psychophysical evidence showing a phase difference of half a cycle between 15-Hz rod signals just below and just above the null region. These effects are apparent not only in the normal observer but also in an achromat observer who lacks functioning cone vision.

Electrophysiology↗

The incremental threshold of the rod visual system and Weber's law.

The incremental threshold of the isolated rod visual system is believed, under certain conditions, to obey Weber's law (that is, to increase in direct proportion to the intensity of the background). This relation was tested at several background wavelengths, over an intensity range for which the target was seen only by the rods. Although the slope on long-wavelength background approximates unity (that is, Weber's law on log-log coordinates), it averages less than 0.8 on short- and middle-wavelength backgrounds. This is the same value as that found for the thresholds of a typical, complete achromat--who lacks cone vision--regardless of background wavelength. These results force the conclusion that Weber's law for incremental threshold detection is achieved not by the rods alone but only by the rods acting together with the cones.

Dark Adaptation↗

Temporal summation in the achromat.

We investigated temporal summation of the rods in a complete achromat, who lacks cone vision. Critical duration (tc) was estimated both at the achromat's preferred area of fixation and at an area 12 deg laterally in the nasal visual field. Comparable tc determinations were made in a normal trichromat. At background luminances of 0.0 and 0.6 scot. td, where the rods mediate detection, the values of tc were similar for the achromat and the normal. At a luminance of 813 scot. tds, however, where the middle-wavelength sensitive cones mediate detection in the trichromat, the tc for the achromat was much longer than that for the trichromat.

Adaptation, Ocular↗