Terminal sleep following delirium tremens in chronic alcoholics--polysomnographic and behavioral study.

Delirium tremens frequently ends with behaviorally deep sleep after which the patient has usually recovered from the withdrawal state. This sleep has been called "terminal sleep" or "critical sleep". In the present study terminal sleep was investigated in 14 chronic alcoholics. Polysomnographic recordings were undertaken during terminal sleep and the patients' behavior was observed after the patients awoke from terminal sleep. A marked decrease in stages 3 and 4 sleep was found in all the patients. Sleep cycles were regularly observed in 10 patients, while in the remaining four patients sleep cycles were not observed in terminal sleep. The patients who exhibited regular sleep cycles had fully recovered from delirium tremens after they awoke from terminal sleep, and they never relapsed into delirium tremens afterwards. In contrast, the patients who demonstrated terminal sleep in which sleep cycles were not observed revealed inactive and sometimes disoriented behavior suggesting slight disturbances of consciousness. These patients developed delirium tremens repeatedly thereafter. Therefore, terminal sleep can be divided into two different types. One is recovery sleep from sleep deprivation induced by delirium tremens, in which sleep cycles are observed. The other is not sleep, but a state which is indicative of disturbances of consciousness.

Adult↗

Pulmonary function of nonsmoking female asbestos workers without radiographic signs of asbestosis.

Researchers disagree about whether exposure to asbestos causes significant respiratory impairments and airway obstruction in the absence of radiographic asbestosis and smoking. To obtain confirmatory information, the authors examined pulmonary function of 208 nonsmoking female asbestos workers who did not have asbestosis and 136 controls. The authors observed an overall lower single-breath carbon monoxide diffusing capacity in the asbestos workers than in controls. In addition, significant decreases in percentage vital capacity, percentage forced vital capacity, and percentage mean forced expiratory flow during the middle half of the forced vital capacity were evident in the older workers. Logistic regression analysis revealed that asbestos exposure was associated with abnormal single-breath carbon monoxide diffusing capacity, vital capacity, and mean forced expiratory flow during the middle half of the forced vital capacity among the older workers. The age-related decline in vital capacity, forced vital capacity, and mean forced expiratory flow during the middle half of the forced vital capacity was significantly greater in the asbestos workers than the controls. The findings imply that asbestos-exposure per se contributes predominantly to restricted lung volume and reduced single-breath carbon monoxide diffusing capacity. Asbestos may also cause slight airway obstruction, especially in workers who are heavily exposed.

Adult↗

Changes of recollected menarcheal age and month among women in Tokyo over a period of 90 years.

Data on the recollected age at menarche of 47,881 women born between 1881 and 1970 were examined. The mean menarcheal age had changed from 15.1 years in those born up to 1900 to 12.5 years in those born during the 1960s. The age at menarche differed according to the month of birth, and the pattern of average age distribution by month of birth was not the same when the year of birth was different. Among women born before 1955 the menarcheal age was earlier in those born in the summer. However, among women born after 1955, menarche occurred later when they were born in the summer. The monthly distribution of menarche had also changed during this 90-year period. Two peaks in April and August were prominent among those born up to 1960. A third peak in January became also apparent in those born after 1960.

Adolescent↗

Preclinical evaluation of a hollow fiber silicone membrane oxygenator for extracorporeal membrane oxygenator application.

A silicone membrane hollow fiber oxygenator applicable for use as an extracorporeal membrane oxygenator (ECMO) has been developed in our laboratory. This silicone hollow fiber displays astonishing mechanical stability, is barely compressible or stretchable, and assembles easily while maintaining good gas permeability. The priming volume is 140 cc with a surface area of 0.8 m2. This study evaluated the gas transfer performances and biocompatibility of the oxygenator under ECMO and CPB conditions. In vitro studies that were performed at a blood flow rate of 2 L/min, and revealed O2 and CO2 gas transfer rates of 82.35 +/- 0.56 ml/m2/L/min and 38.72 +/- 2.88 ml/m2/L/min, respectively. The commercially available Kolobow (Avecor 1500) oxygenator was used as the control, and had O2 and CO2 gas transfer rates of 53.8 +/- 0.5 ml/m2/L/min and 24.7 +/- 2.0 ml/m2/L/min. To evaluate blood trauma, Normalized Index of Hemolysis (NIH) was measured according to American Society of Testing and Materials (ASTM) standards. The NIH findings were 0.0112 g/100L at a blood flow of 1 L/min, and 0.0152 g/100L at 5 L/min. Three ex vivo experiments, using a blood flow rate of 1 L/min, were performed with venoarterial bypass, and O2 transfer rate and CO2 transfer rate of the oxygenators were well maintained. This indicates that this preclinical silicone membrane hollow fiber oxygenator has superior efficiency, less blood trauma, and is smaller when compared with the only clinically available Kolobow oxygenator.

Animals↗

Blood trauma induced by clinically accepted oxygenators.

Hemolysis remains one of the most serious problems during cardiopulmonary bypass (CPB), extracorporeal membrane oxygenation (ECMO), and percutaneous cardiopulmonary support (PCPS). However, the hemolytic characteristics associated with oxygenators are not well defined. A specialized hemolysis test protocol for oxygenators was developed. A comparative study was performed following this protocol to determine the hemolytic characteristics of the clinically available oxygenators during CPB; pressure drop measurements in the blood chamber were also performed. Four oxygenators (Medtronic Affinity, Cobe Optima, Terumo Capiox SX25, and Bard Quantum) were evaluated. Fresh blood from healthy Dexter calves anticoagulated with citrate phosphate dextrose adenine solution was used. The blood flow was fixed at 5 L/min, similar to that used in CPB. The Normalized Index of Hemolysis for Oxygenators (NIHO) has been modified according to the American Society of Testing and Materials (ASTM) standards. The NIH value, which was obtained from the circuit without an oxygenator, was subtracted from the primary NIH value, obtained from the circuit with an oxygenator to eliminate the effects of a centrifugal pump or other artifacts. The NIHO value was the lowest in the Affinity (0.0116 +/- 0.0017) and increased from Affinity < Optima (0.0270 +/- 0.0038) < Capiox (0.0335 +/- 0.0028) < Quantum (0.0416 +/- 0.0015 g/100 L). The Optima and Capiox did not demonstrate a significant difference. In addition, this NIHO value has a close relationship to the pressure drop. In conclusion, this new evaluation method is suitable to compare the biocompatibility performance of different types of clinically available oxygenators for CPB usage.

Animals↗

Direct detection of red blood cell fragments: a new flow cytometric method to evaluate hemolysis in blood pumps.

Pump induced hemolysis is presently evaluated by measuring plasma free hemoglobin (fHb). However, this method has disadvantages because quantification of fHb depends on hematocrit (HCT) and hemoglobin (Hb) levels. The aim of this work was to devise a hemoglobin independent method, capable of quantifying cell trauma directly by measuring the number of red blood cell (RBC) fragments. Whole blood flow cytometry was used to quantify circulating RBC fragments derived from a roller pump (Sarns, Inc. Model 2 M 6,002) and a centrifugal pump (Gyro C1E3, Kyocera Corp.). The pumps were tested in a mock circuit for 2 hr (5 L/min flow against 100 mm Hg pressure head). Red blood cell fragments were quantified by a phycoerythrin (PE) labeled glycophorin A antibody specific for erythrocytes. Red blood cell fragments were smaller than the intact RBC population and overlapped in size with the platelet population (based on forward- and side-light scattering measurements). For the roller pump, the values for RBC fragments increased from 1,090 +/- 260/microl at 0 min to 14,880 +/- 5,900/microl after 120 min. In contrast, using the centrifugal pump, there was little increase in RBC fragments (from 730 +/- 270/microl at 0 min to 1,400 +/- 840/microl after 120 min). Flow cytometry can be used for the rapid, sensitive, hemoglobin independent evaluation of pump induced RBC trauma.

Erythrocytes↗

Operating point control system for a continuous flow artificial heart: in vitro study.

We proposed and developed a practical and effective servo control system for rotary blood pumps. A rotary blood pump for assisting the failing natural heart should be operated only in physiologically acceptable conditions. The operation of a rotary blood pump is based on the rotational speed of the impeller and pressure head. If the pump flow and the pressure head are set within an acceptable range, the driving condition is deemed normal condition, and this control system maintains the preset operating point by applying proportional and detective control (PD control). If the pump flow or pressure head is outside the acceptable range, the driving condition is determined to be abnormal condition, and this system operates the pump in a recovery fashion. If the driving condition is kept under abnormal conditions of sudden decrease of the flow, the condition is termed a suction condition. The controller releases the pump from the suction condition and later returns it to the normal condition. In this study, we evaluated these servo control modes of the centrifugal pump and confirmed whether the performance of this proposed operating point control system was practical.

Algorithms↗