Search PubMed⌕ Search

Biomedical subjects

K Nishimura

Publications and source records attributed to K Nishimura.

At least 1,243 records · Page 69Linked to original sources

[Studies on the in vitro bactericidal effects of cephalexin against Staphylococcus aureus (author's transl)].

The effect of cephalexin on the numbers of viable cells was studied. Two strains of Staph. aureus and 6 strains of Escherichia coli at their logarithmic phase were exposed to various concentrations (1 approximately 4 MICs) of cephalexin for 1 approximately 24 hours in vitro. The numbers of viable cells were determined by the colony-counting method during and after the exposure of cephalexin. The following results were obtained: 1. When exposure time was short (3 hours or less), the numbers of viable cells were not decreased even at the high concentration (4 MICs). And more exposure time (4 hours or more) was needed for decreasing the number of cells. 2. "Concentration" was not strong influencing factor for decreasing the numbers of cells as compared with "Exposure time". 3. From the point of decreasing the numbers of cells for 12 hours, 4-hour exposure to 1 MIC was more effective than 2-hour twice exposure at 4-hour nonexposure interval to 4 MICs of cephalexin.

Cephalexin↗

Solubilization of angiotensin I-coverting enzyme from rabbit lung using trypsin treatment.

The solubilization of angiotensin I-converting enzyme (peptidyldipeptide hydrolase, EC 3.4.15.1) from rabbit lung was carried out using trypsin treatment. A good recovery of 76% was obtained. The enzyme from solubilized fraction was purified using colums of Sephadex G-200, hydroxyapatite and DEAE-cellulose. The purified enzyme was shown to convert angiotensin I to angiotensin II and also to inactivate bradykinin. The specific activity of the enzyme was 24.3 units/mg protein for hippurylhistidylleucyl hydroxide and 0.182 mumol/min per mg protein for angiotensin I. The enzymic activity obtained after trypsin treatment for 5 h could be divided into two components: (i) an enzyme of molecular weight 300 000 (peak II) and (ii) an enzyme of molecular weight 145 000 (peak III), by Sephadex G-200 gel filtration. The molecular weight of the denatured enzyme was found to be 155 000 by disc gel electrophoresis in the presence of sodium dodecyl sulfate. Km values of peak II and peak III fraction for Hippuryl-His Leu-OH were 2.6 mM.

Animals↗

Studies on perithecium of Ceratocystis stenoceras by a scanning electron microscope.

The surface and cavity of the perithecium of Ceratocystic stenoceras were studied with a scanning electron microscope. The body was spherical, 96-231 u in diameter, and the surface was covered with hyphae. The neck was a lanky hollow cylinder and the wall consisted of a bundle of tubular hyphae encircling a central canal. A whorl of hyaline hyphae was found at the tip of the neck. The surface of the neck from the body to a distance of about 1/6 was rough and warty. But the surface of the neck above that place was smooth, on which a regular design could be seen. The wall of the neck the body consisted of 5-6 layers of cells. However, the wall at the tip was of 1-2 layers of cells. The cavity was filled with ascospores. They were like segments of an orange of 1 X 2 u with smooth surface.

Fungi↗

Affinity chromatography of angiotensin I-converting enzyme from rabbit lung using hippurylhistidylleucyl-OH.

Approximately 50-fold purification of angiotensin I-converting enzyme (Peptidyldipeptide hydrolase, EC 3.4.15.1) from rabbit lung was achieved by affinity chromatography using the synthetic substrate Hippuryl-His-Leu-OH. The specific activity of the enzyme was increased from 0.044 units/mg protein to 1.911 units/mg protein for Hippuryl-His-Leu-OH and from 0.33 nmol/min per mg protein to 13.8 nmol/min per mg protein for angiotensin I.

Angiotensin II↗

Real-time observation of cardiac movement and structures in congenital and acquired heart diseases employing high-speed ultrasonocardiotomography.

Echocardiography has proved useful for cardiac diagnosis during the past several years; however, the conventional one-dimensional ultrasound pulse echo method cannot easily visualize the anatomical relationships of the various cardiac structures. To overcome the limitation, the authors attempted a real-time observation of cardiac structures and introduced high-speed ultrasonocardiotomography with a Sonolayergraph Model SSL-51H (Toshiba) having a logarithmic amplifier. Thirty sector images are produced per second by a mechanically operated, single flat or 75 mm. focus transducer measuring 10 mm. in diameter. The angle of a sector image composed of about 120 scanning lines is arbitrarily changeable from null to 65 degrees. The fast succession of images produced enables clear observation of the movement of cardiac structures in real time. Study of 230 patients by means of the proposed system suggests that it is advantageous as a quick method to provide two-dimensional echocardiograms for cardiac diagnosis and assessment, especially in noninvasive diagnosis.

Adult↗

Clinical study on the flow murmurs at the defect area of atrial septal defect by means of intracardiac phonocardiography.

In order to study flow murmurs through atrial septal defects, right heart catheterization was performed on 48 patients of secundum type, four of primum type, and five of probe-patent foramen ovale, with the double-lumen phonocatheter of Lewis, at the tip of which barium titanate was mounted. The flow murmurs at the defect area were classified into three patterns: v murmur, atriosystolic murmur, and mid-diastolic murmur. V murmur was continuous, extending from late systole to diastole, of low to medium pitch, closely related to atrial v wave and augmenting with expiration. It had no significant correlation to the ratio of left-to-right shunt. It was recorded in 32 out of 48 cases of secundum type and one of primum type, but not observed in probe-patent foramen ovale. Atriosystolic murmur was noted in 17 of 48 cases of secundum type and one of primum type. It was connected with atrial a wave. Mid-diastolic murmur was found at the defect area in four subjects of secundum type. It was thought to be an independent entity from v murmur and to be another one due to shunt flow through the septal defect, since it had no relation to v wave but it was localized between v and a waves in the pressure curve of the right atrium. It is different in localization from mid-diastolic murmur due to relative tricuspid stenosis at the inflow tract of right ventricle.

Adult↗

Partial purification and properties of porcine thymus lactosylceramide beta-galactosidase.

Porcine thymus lactosylceramide beta-galactosidase was purified by a simple procedure. In the final step of isoelectric focusing the enzyme was separated into two peaks of pI 6.3 (peak I) and 7.0 (peak II), which showed 3,600- and 4,000-fold enhancement of lactosylceramide-hydrolysing activity, respectively. The two peaks had identical mobility on polyacrylamide gel electrophoresis. The apparent molecular weight was 34,000. Neither monosialoganglioside (GM1) nor galactosylceramide was hydrolysed by the purified enzyme fractions. The optimal pH was at 4.6, and sodium taurocholate was essential for the reaction. The apparent Km was 2.3 x 10-5 M. The reaction was stimulated by sodium chloride and linoleic acid, while it was strongly inhibited by Triton X-100 and bovine serum albumin. Galactosylceramide, p-nitrophenyl beta-galactoside, and p-nitrophenol were weak inhibitors. No effects of GM1 and galactose were observed on the hydrolysis of lactosylceramide.

Animals↗

Real-time observation of ruptured right sinus of Valsalva aneurysm by high speed ultrasono-cardiotomography. Report of a case.

A two-dimensional echocardiographic manifestation of a ruptured right sinus of Valsalva aneurysm is described in this case report. The ultrasono-cardiotomograms demonstrated the aneurysm cut longitudinally and protruding into the outflow tract of the right ventricle. The configuration of the aneurysm was consistent with the contrast medium-filled sinus demonstrated by angiocardiography. In systole, the aneurysmal sinus moved anteroinferiorly together with the aortic wall. The echocardiogram revealed an abnormal two-layered horizontal echo in the right ventricle which showed the aneurysm when the ultrasonic beam passed through the interventricular septum near the aortic root and mitral leaflets. During the operation, the protruding sinus and a small interventricular septal defect in the membranous septum under it were observed through the opened right ventricle. After the closure of the aneurysm, the two-dimensional echocardiogram no longer showed an abnormal configuration.

Adult↗