Search PubMed⌕ Search

Biomedical subjects

K Najafi

Publications and source records attributed to K Najafi.

22 records · Page 2Linked to original sources

Scaling limitations of silicon multichannel recording probes.

This paper describes the scaling limitations of multichannel recording probes fabricated for use in neurophysiology using silicon integrated circuit technologies. Scaled silicon probe substrates 8 microns thick and 16 microns wide can be fabricated using boron etch-stop techniques. Theoretical expressions for calculating the thickness and width of silicon substrates have been derived and agree closely with experimental results. The effects of scaling probe dimensions on its strength and stiffness are described. The probe shank dimensions can be designed to vary the strength and stiffness for different applications. The scaled silicon substrates have a fracture stress of about 2 x 10(10) dyn/cm2, which is about six times that of bulk silicon, and are strong and very flexible. Scaling the feature sizes of recording electrode arrays down to 1 micron is possible with less than 1 percent electrical crosstalk between channels.

Electronics, Medical↗

Strength characterization of silicon microprobes in neurophysiological tissues.

Strength characteristics of thin-silicon probes in neural tissues have been determined experimentally. It is shown that by proper selection of the substrate length, width, and thickness, silicon substrates can be designed and used to penetrate a variety of biological tissues without breakage or excessive dimpling. Thin-silicon structures have a maximum fracture stress which is a factor of six larger than bulk silicon, and are very flexible and capable of bending to angles larger than 90 degrees. Silicon substrates 15 microns thick x 30 microns wide can easily penetrate guinea pig and rat pia arachnoid layers with minimum dimpling and no breakage, while substrates 30 microns thick x 80 microns wide can penetrate guinea pig and rat dura mater repeatedly without breakage. Quantitative comparison on the relative toughness of neurophysiological tissues in rat and guinea pig have also been experimentally obtained.

Animals↗

Batch-fabricated thin-film electrodes for stimulation of the central auditory system.

Silicon micromachining and thin-film technology have been employed to fabricate iridium stimulating arrays which can be used to excite discrete volumes of the central nervous system. Silicon multichannel probes with thicknesses ranging from 1 to 40 microns and arbitrary two-dimensional shapes can be fabricated using a high-yield, circuit-compatible process. Iridium stimulating sites are shown to have similar characteristics to iridium wire electrodes. Accelerated pulse testing with over 8 million 100 microA biphasic current pulses on 8000 microns 2 sites has demonstrated the long-term stability of iridium and activated iridium sites. In vivo tests have been performed in the central auditory pathways to demonstrate neural activation using the devices. These tests show a selective activation both as a function of site separation and site size.

Animals↗