Search PubMed⌕ Search

Biomedical subjects

K N Bachus

Publications and source records attributed to K N Bachus.

At least 37 records · Page 2Linked to original sources

Reproducibility of techniques using Archimedes' principle in measuring cancellous bone volume.

Researchers have been interested in developing techniques to accurately and reproducibly measure the volume fraction of cancellous bone. Historically bone researchers have used Archimedes' principle with water to measure the volume fraction of cancellous bone. Preliminary results in our lab suggested that the calibrated water technique did not provide reproducible results. Because of this difficulty, it was decided to compare the conventional water method to a water with surfactant and a helium method using a micropycnometer. The water/surfactant and the helium methods were attempts to improve the fluid penetration into the small voids present in the cancellous bone structure. In order to compare the reproducibility of the new methods with the conventional water method, 16 cancellous bone specimens were obtained from femoral condyles of human and greyhound dog femora. The volume fraction measurements on each specimen were repeated three times with all three techniques. The results showed that the helium displacement method was more than an order of magnitudes more reproducible than the two other water methods (p < 0.05). Statistical analysis also showed that the conventional water method produced the lowest reproducibility (p < 0.05). The data from this study indicate that the helium displacement technique is a very useful, rapid and reproducible tool for quantitatively characterizing anisotropic porous tissue structures such as cancellous bone.

Animals↗

Determining mineral content variations in bone using backscattered electron imaging.

The mechanical properties of bones are greatly influenced by the ratio of organic constituents to mineral. Determination of bone mineral content on a macroscopic scale is straightforward, but microscopic variations, which can yield new insights into remodelling activities, mechanical strength, and integrity, are profoundly more difficult to measure. Measurement of microscopic mineral content variations in bone material has traditionally been performed using microradiography. Backscattered electron (BSE) imaging is a technique with significantly better resolution than microradiography with demonstrated consistency, and it does not suffer from projection-effect errors. We report results demonstrating the applicability of quantitative BSE imaging as a tool for measuring microscopic mineral content variations in bones representing a broad range of mineralization. Bones from ten species were analyzed with Fourier-transformed infrared spectroscopy, X-ray diffraction, energy dispersive X-ray spectrometry, ash measurements, and BSE imaging. BSE image intensity (graylevel) had a very strong positive correlation to mineral (ash) content. Compositional and crystallographic variations among bones had negligible influence on backscattered electron graylevels. The present study confirms the use of BSE imaging as a tool to measure the microscopic mineral variability in a broad range of mineralized tissues.

Animals↗

Analysis of particles in acetabular components from patients with osteolysis.

Acetabular polyethylene components were quantitatively analyzed for the presence of third body particles from 38 consecutively retrieved components. Backscattered electron imaging and correlated energy dispersive x-ray analysis were used for the assessments. Retrievals were divided into 4 groups based on methods of fixation and metal alloy types: 8 hydroxyapatite coated, 6 cobalt chrome porous coated, 17 titanium porous coated, and 7 cemented implants were evaluated. The backscattered electron imaging data showed that the components from the hydroxyapatite coated implants had larger particles than did the components from the cemented group. The hydroxyapatite group had 51 +/- 52 particles per mm2. The cobalt chrome alloy group had 10 +/- 9 particles per mm2, and the titanium alloy group had 9 +/- 16 particles per mm2. The cemented group had 5 +/- 4 particles per mm2. The difference between the cement group and the hydroxyapatite group was statistically significant. The elemental analysis showed that 70% of the particles in the hydroxyapatite group had calcium and phosphorus elements. Third body particles likely contribute to particulate generation. The results suggest that the hydroxyapatite coated components have the potential for producing greater amounts of particulate debris. Continued analysis of retrieved components for the presence of the third body particles is required.

Acetabulum↗

Lymphoreticular dissemination of metal particles after primary joint replacements.

Twenty-three patients with a history of primary joint replacement followed by lymph node dissection procedure were studied. These specimens included pelvic, gastric, paraaortic, inguinal, retroduodenal, and axillary node chains. The lymph node specimens were sectioned, processed for scanning electron microscopic study, and viewed with backscattered electron imaging to identify metal particles. On detection of a metal particle, energy dispersive x-ray microanalysis was conducted to determine its elemental composition. Seven of 23 patients had metal alloy particles within the lymph node specimens. Metal particles were identified in the pelvic and axillary node chains. In each case, the metal alloy identified corresponded with the implanted type of alloy. The shortest interval between joint implantation and dissemination of metal to a lymph node chain was 6 months. These data suggest the need for continued followup to determine long term effects, if any, of this distribution of metal particles through the lymphatic system.

Aged↗

Progression of human bone ingrowth into porous-coated implants. Rate of bone ingrowth in humans.

We report the measured progression of human cancellous bone ingrowth into load-bearing porous-coated titanium implants over 5 time periods (0, 3, 6, 9, and 12 months). There was a statistically significant progression of bone ingrowth into the implants over a 9-month period, but the 9- and 12-month data were not different. Investigators are advised to analyze time "0" implants in order to distinguish mechanical impaction of bone from the biological process of bone ingrowth.

Aged↗

Inability of energy dispersive X-ray analysis to identify particulate polyethylene.

There are limitations to all techniques used to identify particulate polyethylene in histological specimens. The goal of our study was to determine if remnant metal elements used during the catalytic production of ultra high molecular weight polyethylene, could be used as markers for particulate polyethylene detection in histological specimens. It was hypothesized that these catalyst elements could be detected in polyethylene using energy dispersive X-ray elemental analysis. Six samples from five different companies were evaluated. These included virgin polymer powder, polyethylene bar stock, and artificial joint components. Five specimens from each of the six samples were analyzed with energy dispersive X-ray elemental analysis. After elemental analysis was completed, only 2 of 30 specimens were positive for the catalyst elements. In the remaining 28 specimens, catalyst elements were not detected. Our investigation demonstrates that energy dispersive X-ray elemental analysis is not currently a feasible method of particulate polyethylene detection. Additional techniques will need to be developed to accurately identify particulate polyethylene in histological specimens.

Beryllium↗

Mineral apposition rates of human cancellous bone at the interface of porous coated implants.

Human cancellous bone ingrowth studies were conducted on 19 consenting bilateral total knee arthroplasty (TKA) patients. Titanium porous coated cylinders were implanted into the medial femoral condyle of the contralateral knee during the first of two TKAs. Retrieval was performed at the time of the second TKA (6-131 weeks later), and fluorochrome analysis was conducted. Mean mineral apposition rates (MAR) at the interface measured 1.0 micron/day, whereas 4 mm away, the peripheral bone had a mean MAR of 0.8 micron/day. This represented a 25% acceleration in the interface bone remodeling rate when compared with the periphery (P < .05). This study showed the bone advanced appositionally at the interface at a rate of approximately 1 micron/day. Analysis showed that when bone was over 50 microns from the porous coating, bone ingrowth did not occur. These results emphasize the need for surgical precision and careful postoperative management to achieve bone ingrowth.

Aged↗

Analysis of the bone surface area in resected tibia. Implications in tibial component subsidence and fixation.

Anterior subsidence of the tibial component is still a clinical complication requiring revision in total knee replacement. Using the scanning electron microscope, a quantitative 3-dimensional stereoscopic and digitizing study was conducted on the cortical and cancellous bone surface area from 10 resected human cadaveric tibia. The data demonstrated that the cortical bone surface area covered an average of 6% of the total tibial surface area, cancellous bone 18%, and bone marrow space 76%. By conducting anatomic regional analysis, the data showed significantly higher (p < or = 0.05) bone quantities in the posteromedial and medial regions as compared with the anterior and anterolateral regions. These data help to explain why tibial component subsidence occurs anteriorly in total knee replacement. The data also suggest that if long-term component subsidence and loosening is to be limited, either biologic cement or bone cement would be required to increase the surface attachment between the tibial component and resected cancellous bone.

Adult↗

The meaning of graylevels in backscattered electron images of bone.

Backscattered electron (BSE) imaging is considered to be a useful technique for determining relative differences in bone tissue density. However, it is not clear how graylevel variations seen in BSE images of bone tissue, which are primarily dependent on the tissue's average atomic number, correlate to tissue density (g/cm3) and mineral content. Simulated bone tissues, ranging from 32-50% mineral by volume, were made by mixing synthetic hydroxyapatite with a simulated organic matrix. This technique allowed mineral content to be varied while mineral composition and crystallography remained constant. The densities of the simulated tissues were determined using Archimedes' principle. Average atomic numbers of the simulated tissues were interpolated from a regression of BSE graylevel against average atomic numbers of pure standard materials. A strong positive correlation was found to exist between mineral content and density (r2 = 0.978) as well as between mineral content and atomic number (r2 = 0.965). The average graylevel in the BSE image also exhibited a positive correlation to mineral content (r2 = 0.965) and density (r2 = 0.923). Graylevel variations in BSE images of simulated bone tissue were shown to be strongly correlated to density and mineral content, but only as a coincidence of their association with atomic number.

Biocompatible Materials↗

Influence of mineral content and composition on graylevels in backscattered electron images of bone.

To determine the meaning of graylevels in backscattered electron (BSE) images of actual bone tissues, the influence of mineral content and mineral composition on BSE image graylevels was studied using chick bone tissue representing a broad age range. These tissues were analyzed for BSE image graylevels, Ca/P molar ratios, mineral composition mineral content (v/v), ash fraction (w/w), and density (g/cm3). Linear regression analyses showed that the weighted mean graylevels (WMGLs) in BSE images were positively correlated to ash fraction (r2 = 0.711), mineral content (r2 = 0.720), and density (r2 = 0.843). Although the Ca/P ratio increased from 1.65 in embryos to 1.80 in 2-year olds, the compositional changes corresponding to this Ca/P molar ratio were estimated to produce a relatively minor (< 4.0%) change in BSE image graylevel. These results demonstrate that graylevels in BSE images of actual bone tissue can be attributed to mineral content and density, but only as a coincidence of their association with atomic number.

Age Factors↗

Comparative study of human cancellous bone remodeling to titanium and hydroxyapatite-coated implants.

The human cancellous bone response was compared in weight-bearing porous hydroxyapatite (HA) and titanium-coated implants placed in the distal medial femoral condyles of consenting staged bilateral knee patients. The Institutional Review Board approved study quantified the amount of bone ingrowth, the mineral apposition rate, and the bone mineral content. Results showed that the osteoconductive HA coating increased the amount of bone ingrowth by 8% (P = .018). The HA coating did not effect the mineral apposition rate of the bone but had an 8% lower bone mineral content at the implant interface (P = .042). The influence of HA coatings on human cancellous bone appears highly focal along the coating surface. Gaps of 50-500 microns filled with fibrous connective tissue were observed along the porous-coated surfaces of both implant types suggesting that HA coatings still require precision placement adjacent to human cancellous bone.

Aged↗

Postmortem comparative analysis of titanium and hydroxyapatite porous-coated femoral implants retrieved from the same patient. A case study.

The results of bilateral postmortem analysis of titanium and plasma-sprayed hydroxyapatite (HA) porous-coated femoral components of the same Anatomic Porous Replacement design retrieved from a 35-year-old female donor are reported. Analysis was conducted using backscattered electron imaging, histology, and radiographic techniques. The appositional bone index, percent bone ingrowth, and mineral content were measured for both implants. The results showed a 177% higher appositional bone index (P = .014) for the HA porous-coated Anatomic Porous Replacement component compared to the titanium Anatomic Porous Replacement component. Backscattered electron analysis showed 50% more bone in the HA porous-coated implant (P = .028). The mineral content analysis demonstrated that the bone ingrown into the HA porous-coated device was 23% less mineralized (P = .016). The data from this case study suggested that plasma-sprayed HA porous-coated implants may assist in increasing the amount of bone ingrowth and skeletal attachment in total hip arthroplasties.

Adult↗

Microscopic analysis of autograft bone applied at the interface of porous-coated devices in human cancellous bone.

This study describes the response of human cancellous bone when autologous bone chips are added at operation to the interface between host bone and porous-coated implants. During the first operation of a staged bilateral total knee arthroplasty, seven patients consented to have paired porous-coated devices implanted into their opposite medial femoral condyle. One device of each pair had autologous bone chips applied to the porous-coating, and the other was not grafted and was a control. The devices were removed en bloc at the second total knee arthroplasty 6 to 49 weeks later. Backscattered electron imaging showed significantly more bone (p < or = 0.05) in the porous-coating of the implant treated with autologous bone chips which significantly increased (p < or = 0.05) the amount of bone available at the interface. The grafted devices had a mineral apposition rate of 1.04 +/- 0.20 microns/day for the interface and 0.81 +/- 0.09 microns/day for the peripheral bone. This compared with corresponding figures of 1.03 +/- 0.38 microns/day and 0.79 +/- 0.19 microns/day at the ungrafted devices. The mineral apposition rate at the interface of the porous-coated implants was significantly increased (p < or = 0.05) relative to the host bone in the periphery. Our results support the view that autologous bone chips are effective in attaching cementless porous-coated total knee replacements to the human skeleton by bone ingrowth.

Aged↗

Effect of the tibial cut on subsidence following total knee arthroplasty.

In 33 total knee arthroplasties (TKAs) using instrumentation designed to cut the tibia with 0 degree posterior slope, ten tibial components demonstrated at least 2 mm of tibial component subsidence. These subsided components were implanted onto tibiae with an average of 8 degrees +/- 2 degrees difference between the preoperative, anatomic posterior slope and their postoperative posterior slope. The remaining 23 components, without subsidence, were implanted onto tibiae cut within 2 degrees +/- 2 degrees of their anatomic slope. To help understand these clinical observations, a laboratory study was performed to compare the load carrying capacity and the stiffness of tibial subchondral bone following two types of tibial cuts: one made perpendicular to the long axis of the tibia and the other made parallel to the articular surface of the tibia. Mock tibial baseplates mounted on paired cadaver tibiae were loaded in compression and force displacement curves were recorded. Tibiae cut parallel to the surface exhibited 40% greater load carrying capacity and 70% greater stiffness than the paired tibiae cut perpendicular to the long axis. The biomechanical data of this study indicated that cutting the tibia perpendicular to the long axis results in weaker bone that may be inadequate to support a tibial component. This may explain the higher incidence of clinical subsidence if the tibial cut is not made approximately parallel to the anatomic slope.

Aged↗

Reproducible methods for calibrating the backscattered electron signal for quantitative assessment of mineral content in bone.

Backscattered electron (BSE) imaging shows promise for orthopaedic and bone research. BSE images of bone may be captured on-line directly from the scanning electron microscope (SEM), and then analyzed to produce a backscattered electron profile (BSEP), a modified image graylevel histogram which is representative of the mineral content in bone. The goals of this work were 1) develop a reproducible graylevel calibration technique for bone specimens, and 2) determine a conservative time interval during which SEM operating conditions would remain stable. Calibration standards containing pure aluminum and pure magnesium wires were placed in the SEM with human cancellous bone. Baseline imaging conditions were first established by adjusting the SEM until the bone image displayed good resolution and graylevel separation between regions of different mineral content. Microscope brightness and contrast controls were randomly changed to initiate the new operating conditions of another imaging session, and graylevel values from the calibration metals were used to readjust the microscope back to baseline operating conditions. Weighted mean graylevel values of the BSEPs from calibration trials were compared to those of the baseline. Data showed that bone images could be reproduced within 1.2 percent. It was also concluded that our equipment required calibration checks at 20 minute intervals.

Animals↗

Backscattered electron imaging: the role in calcified tissue and implant analysis.

The working distance and tilt studies helped to clarify the influences of specimen variability when the BSE mode is used in calcified tissue research. This work has shown that the BSEPs of cortical bone may be accurately maintained within 2 percent error over a 10 degree range of tilt, or 300 microns working distance variation. If future bone and implant investigators wish to conduct accurate, quantitative mineral microanalysis in bone, then standard grinding and polishing techniques should be adequate if calibration procedures are developed. The BSEP characteristics of the pure metals make them suitable to be used for calibrating the BSE signal. BSE analysis, with correlated biomechanical studies, will lead us to a better understanding of the relationships between structure, function, and mineral content in bone. On-line BSEP analysis techniques will expand our understanding of the mineralization events in bone which are associated with aging, weightlessness, pharmaceutical therapies, and the presence of biomaterials. The future of the BSE imaging technology and the contributions to be made in understanding the histometry, biomechanics and mineral content of bone as well as bone's response to implant materials has just begun to unfold.

Biocompatible Materials↗

Thermal effects of the electron beam and implications of surface damage in the analysis of bone tissue.

Electron beam interactions with specimens in the scanning electron microscope (SEM) can lead to increased surface temperatures and damage. These changes may have significant consequences in the analysis of bone tissue. An investigation was performed to measure the surface temperature changes associated with the electron beam on a thermocouple with systematic variations in operating conditions. Probe currents, magnifications, and accelerating voltages were incrementally adjusted to measure the temperature changes and to make assessments for determining optimal operating conditions for the SEM in future analyses of bone tissue. Results from this study suggest that thermal effects were minimal at lower accelerating voltages (< 20 kV), lower probe currents (< 10 nA), and lower magnifications, but surface damage may still occur during the analysis of bone tissue.

Animals↗

Segmental pedicle screw fixation or cross-links in multilevel lumbar constructs. a biomechanical analysis.

BACKGROUND CONTEXT: The placement of segmental pedicle screws and cross-links in short segment posterior pedicle screw constructs has been shown to increase the construct stiffness in some planes. To date, no studies have looked at the contributions of segmental pedicle screw and cross-link placement in longer constructs. PURPOSE: To evaluate the influence of segmental pedicle screw and/or cross-link placement on flexion/extension, lateral bending and axial torsion stiffness in two- and three-level posterior pedicle screw fixation constructs. STUDY DESIGN/SETTING: An in vitro biomechanical analysis of two- and three-level posterior pedicle screw constructs with and without segmental fixation and/or cross-links was performed using calf lumbar spines. Stiffness of the constructs was compared. METHODS: Six calf lumbar specimens were used to test stiffness in one-, two- and three-level posterior pedicle screw fixation constructs in 12 configurations. A custom-made, four-axis spine simulator applied pure cyclical (+/-5 Nm) flexion/extension, lateral bending and axial torsion moments at 0.1 Hz under a constant 50-N axial compressive load. The stiffness of each construct was calculated about each axis of rotation. Data were analyzed using nonparametric techniques with statistical significance determined at alpha less than .05. RESULTS: The stiffness of the instrumented spines were significantly greater than the noninstrumented intact spines in all loading conditions for one-, two- and three-level constructs. There were no significant changes in flexion/extension stiffness with the addition of either the cross-links or the segmental pedicle screws. In lateral bending, the addition of segmental pedicle screws significantly increased the stiffness in the two- and three-level constructs. The addition of two cross-links increased lateral bending stiffness in the longer three-level constructs, with little change in the two-level constructs. In axial torsion, the progressive addition of cross-links showed a tendency toward increased stiffness in both the two- and three-level constructs. Segmental pedicle screws further increased torsional stiffness of the longer, three-level constructs. CONCLUSIONS: As the use of segmental spinal instrumentation progresses from one to two and three levels, the contribution of cross-links and segmental pedicle screws to the overall construct stiffness increases.

Animals↗