Search PubMed⌕ Search

Biomedical subjects

K N An

Publications and source records attributed to K N An.

At least 91 records · Page 5Linked to original sources

Flexor tendon-tendon sheath interaction after tendon grafting: a biomechanical study in a human model in vitro.

A human cadaver tendon sheath model was used to study the differences in excursion resistance of tendons that might be considered as sources of clinical tendon grafts. The flexor digitorum profundus and superficialis tendons, the extensor indicis proprius tendon used in its normal proximal-distal orientation, the extensor indicis proprius tendon used in a reversed distal-proximal orientation, and the palmaris longus tendon were studied in 7 fingers. The intrasynovial tendons (the flexor digitorum profundus and superficialis tendons and the reversed extensor indicis proprius tendon) produced less excursion resistance (p < .05) than the extrasynovial tendons (the normally oriented extensor indicis proprius tendon and the palmaris longus tendon). In contrast to studies measuring resistance against a single pulley, resistance within a complete tendon sheath may be affected by contact with other structures, particularly in joint extension.

Aged↗

The static rotator cuff does not affect inferior translation of the humerus at the glenohumeral joint.

BACKGROUND: The static contribution of the rotator cuff to the inferior stability of the shoulder is poorly understood. The purpose of this study was to determine the effect of static rotator cuff muscles on the inferior stability of the glenohumeral joint. METHODS: The humeral head positions relative to the glenoid were obtained in 12 shoulder specimens under the following conditions: with and without a 1.5-kg load; with the humerus adducted and abducted 90 degrees; and in three stages of dissection: (1) before release of any of the rotator cuff muscles, (2) after release of the supraspinatus or the cuff muscles other than the supraspinatus, and (3) after release of all of the cuff muscles. The order of release was changed in two ways: release of the supraspinatus followed by the release of other muscles in one group, and the opposite order in the other group. RESULTS: In both adduction and abduction, there were no significant differences in the positions of the humeral head either among the three stages of release or between the two different orders of release. CONCLUSION: The static contribution of the cuff muscles to the inferior stability of the shoulder is insignificant.

Biomechanical Phenomena↗

Biomechanical analysis of prophylactic fixation for middle third humeral impending pathologic fractures.

For determination of the most biomechanically desirable construction for prophylactic fixation of impending central 1/3 humeral fractures, 24 matched pairs of fresh frozen skeletonized human cadaveric humeri were divided randomly into four groups. Group 1 compared intact humeri with matched humeri that had a 50% hemicylindrical cortical central 1/3 defect to show reproducible failure at the defect with significant reduction in strength. Groups 2 through 4 compared prophylactic fixation of the defect combined with cementation and dynamic compression plating, Rush rodding, or locked intramedullary nailing. Each specimen was tested in external rotation torsion to failure by fracture. In Group 1, test specimens with defects failed with significantly lower rotation to failure, peak torque, stiffness, and total energy absorbed to failure. In Groups 2 through 4, intramedullary nailing provided statistically significantly better total energy absorbed to failure and stiffness than did dynamic compression plating. The proximally and distally locked intramedullary nail seems to have biomechanical advantages in the prophylactic stabilization of an impending pathologic fracture of the central 1/3 of the humerus. These biomechanical findings must be considered in light of the clinical context when a means of fixation is selected.

Analysis of Variance↗

Biomechanical evaluation of a proximal tibial opening-wedge osteotomy plate.

This biomechanical study evaluated the static response of a new opening-wedge osteotomy plate to compression and torsion loads in a human cadaver model. This plate incorporates a metal block that distracts the medial tibial cortices to ensure precise correction and prevent bone collapse. The 15-mm plate was inserted into 23 fresh cadaver specimens using a standard surgical technique. Axial loading of 13 specimens (compression) and external rotation loading of 10 specimens (torsion) was performed using a servohydraulic-testing machine. Compression loading resulted in failure at a mean of 1810 N due to bone collapse, fracture, or translation. Torsional loading resulted in failure at a mean of 10 Nm due to fracture of the lateral tibial cortex in all specimens. The ratio of the experimental failure load to the calculated estimate of the knee joint forces during gait were 1.07 in axial compression and 0.925 in torsion. This opening-wedge osteotomy plate construct appears marginally strong enough to withstand the estimated axial load on the proximal tibia during gait. Estimated torsional load on the knee during level walking slightly exceeds the failure load prior to osteotomy healing. This information can be used to guide further experimental protocols for static and dynamic testing of this device to determine the appropriate rehabilitation guidelines following opening-wedge proximal tibial osteotomy.

Aged↗

Reoperation for failed prosthetic replacement used for limb salvage.

Patients with segmental bone and joint replacement prostheses because of tumors increasingly need revision surgery because of their long term survival. Between 1970 and 1990, 208 custom prosthetic replacements were performed for limb salvage in patients with tumors. Reoperations were required in 52 patients. The mean time to reoperation was 37 months. The reoperation procedures included 35 prosthetic revisions, 11 amputations, four arthrodeses, one vascularized fibular graft, and one open reduction and internal fixation of a fracture with supplemental bone graft. Functional assessment using the new Musculoskeletal Tumor Society scoring system was available for the 36 living patients, and their mean rating was 63% (18.9) at 12 years' mean followup. Of the 35 patients who received a new prosthesis, 12 (33%) patients needed a third operation at mean followup of 68 months. The probability of prosthetic survival in the group of 35 patients needing revision to the same or another prosthesis was 79% at 5 years and 65% at 10 years. The chance and frequency of needing reoperation increased as patients survived longer. Reoperations for tumor recurrence or infection usually resulted in amputation. Reoperation for failed initial segmental bone and joint prosthetic replacement is feasible and effective and can be done without jeopardizing subsequent patient and implant survival or without significantly affecting functional results compared with the values before reoperation.

Adolescent↗

EMG study of hand muscle recruitment during hard hammer percussion manufacture of Oldowan tools.

The activity of 17 hand muscles was monitored by electromyography (EMG) in three subjects during hard hammer percussion manufacture of Oldowan tools. Two of the subjects were archaeologists experienced in the replication of prehistoric stone tools. Simultaneous videotapes recorded grips associated with the muscle activities. The purpose of the study was to identify the muscles most likely to have been strongly and repeatedly recruited by early hominids during stone tool-making. This information is fundamental to the identification of skeletal features that may reliably predict tool-making capabilities in early hominids. The muscles most frequently recruited at high force levels for strong precision pinch grips required to control the hammerstone and core are the intrinsic muscles of the fifth finger and the thumb/index finger regions. A productive search for skeletal evidence of habitual Oldowan tool-making behavior will therefore be in the regions of the hand stressed by these intrinsic muscles and in the joint configurations affecting the relative lengths of their moment arms.

Animals↗

A theoretical model to predict distribution of the fabric tensor and apparent density in cancellous bone.

The adaptation of cancellous bone to mechanical forces is well recognized. Theoretical models for predicting cancellous bone architecture have been developed and have mainly focused on the distribution of trabecular mass or the apparent density. The purpose of this study was to develop a theoretical model which can simultaneously predict the distribution of trabecular orthotropy/orientation, as represented by the fabric tensor, along with apparent density. Two sets of equations were derived under the assumption that cancellous bone is a biological self-optimizing material which tends to minimize strain energy. The first set of equations provide the relationship between the fabric tensor and stress tensor, and have been verified to be consistent with Wolff's law of trabecular architecture, that is, the principal directions of the fabric tensor coincide with the principal stress trajectories. The second set of equations yield the apparent density from the stress tensor, which was shown to be identical to those obtained based on local optimization with strain energy density of true bone tissue as the objective function. These two sets of equations, together with elasticity field equations, provide a complete mathematical formulation for the adaptation of cancellous bone.

Bone Density↗

Comparison of two methods for computing abduction moment arms of the rotator cuff.

Biomechanical models of the shoulder mechanism require estimates of muscle moment arm magnitude. Some shoulder models have estimated muscle moment arms by assuming an idealized minimum distance path from the origin to insertion that passes around the bony geometry. Alternatively, the principle of virtual work can be used to estimate moment arms from tendon excursion and joint-angle data. The purpose of this study was to determine if these two methods give different estimates of abduction moment arms for the supraspinatus, infraspinatus, and subscapularis muscles. Muscle moment arms were estimated for these muscles on ten fresh frozen cadaver specimens. The results showed a significant difference between the two estimation methods. Average differences were 3.1 mm (10.6%), 3.9 mm (43.9%), and 7.2 mm (70.3%) for the supraspinatus, subscapularis, and infraspinatus muscles, respectively. These results suggest that shoulder models based on the origin-insertion method may give higher rotator cuff muscle force estimates than methods using the slope of the tendon excursion vs joint angle relationship.

Adult↗

Mechanical advantage of the thumb muscles.

The purpose of this study was to measure the moment arms of four extrinsic muscles (flexor pollicis longus, extensor pollicis longus, extensor pollicis brevis, and abductor pollicis longus) and four intrinsic muscles (flexor pollicis brevis, abductor pollicis brevis, adductor pollicis, and opponents pollicis) of the thumb at the interphalangeal, the metacarpophalangeal, and the carpometacarpal joints in the same cadaver specimens and to examine the specific role of each muscle. Measurements were made on seven fresh frozen cadaver hands. The moment arms were measured during flexion/extension of the interphalangeal joint, flexion/extension and adduction/abduction of the metacarpophalangeal joint, and flexion/extension and adduction/abduction of the carpometacarpal joint. Moment arms were computed using the slope of the tendon excursion joint angle relationship. The specific function of each muscle was determined by multiplying the measured moment arms by the maximum force that each muscle can generate. It was found that the flexor pollicis longus was a pure flexor while flexor pollicis brevis was an adductor as well as a flexor, the extensor pollicis longus was an extensor and an adductor, extensor pollicis brevis was an extensor and a mild abductor, the abductor pollicis longus was an extensor as well as an abductor, the abductor pollicis brevis was mainly an abductor, the adductor pollicis was a major flexor as well as an adductor, and the opponents pollicis was a flexor and an abductor.

Aged↗

Principles of urodynamics pressure measurement and its implication to female continence function.

Urodynamic pressure measurements using catheters have been widely used among clinicians. More often objective interpretation of urodynamic pressure measurements requires fundamental understanding of pressure measurement techniques due to many measurement artifacts. In this study we developed a simplified compound thick-walled cylinder model to investigate the mechanical nature of urodynamic pressure measurement as well as pressure transmission. Efficacy of collagen implantation was also explored. Lamé's formulation was used to find analytical solutions. Pressure transmission can be related to catheter caliber and the compressibility of the urethral tissue (poisson ratio) in a simple mathematical form. The theoretical pressure transmission ratio will be 133% with the additional incompressibility assumption, reflecting the passive structural transmission of intraabdominal pressure increase. The relationship between the pressure measurement error and the catheter caliber was found to be linear (r2 = 0.94 +/- 0.04) and two or more pressure measurements need to be used to find the uninstrumented pressure. It was predicted that collagen implantation treatment might improve the pressure transmission ratio maximally by 33%.

Biomechanical Phenomena↗

Development and validation of a nanometer manipulation and measurement system for biomechanical testing of single macro-molecules.

A biomechanical testing system for single macro-molecules has been developed using optical tweezers. To achieve nanometer manipulation and measurement, a piezo-stage and an interferometer were adopted. A systematic calibration was then performed on the displacement resolution. The piezo-stage has a noise level around 1 nm standard deviation, and the interferometer has a noise level of less than 5 nm standard deviation. The results revealed that the system has a nanometer resolution which is sufficient for the measurement of deformation and stiffness of single macro-molecules.

Biomechanical Phenomena↗

Lunotriquetral ligament properties: a comparison of three anatomic subregions.

The physical attributes of 3 subregions of the lunotriquetral ligament were tested in a computer-controlled multiaxis testing machine using 12 specimens. This allowed measurement of forces, moments, and displacements when ligaments were subjected to distraction, dorsopalmar translation, proximal-distal translation with a 20 N limit, and rotation with a 0.5 Nm limit. After an intact test run, selected subregions were cut randomly. Together with an additional 12 bone-ligament-bone complexes, specimens were tested to failure with servohydraulic load at 5 mm/s. The palmar subregion was thickest (2.3 +/- 0.3 mm), the dorsal and proximal progressively less. Intact rotational displacement was 35 degrees +/- 5.1 degrees, dorsopalmar displacement was 1.6 +/- 0.4 mm and 1.2 +/- 0.5 mm, respectively, proximal-distal displacement was 1.8 +/- 0.5 mm and 1.3 +/- 0.5 mm, respectively, and distractional displacement was 0.3 +/- 0.1 mm. The dorsal subregion provided 62.3% +/- 27.1% of the rotational resistance. The palmar subregion resisted 67.3% +/- 14.1% of palmar translation, while with dorsal translation both regions resisted equally. Rotational displacement increased 15.3 degrees +/- 5.6 degrees after dorsal subregion sectioning. The palmar component failure force was 301 +/- 36 N; the dorsal, 121 +/- 42 N; and the proximal, 64 +/- 14 N.

Biomechanical Phenomena↗

The lunotriquetral joint: kinematic effects of sequential ligament sectioning, ligament repair, and arthrodesis.

This experiment was conducted to study the effects of sequential sectioning of the ligaments of the lunotriquetral (LT) joint and the effects of simulated repair or arthodesis on kinematics of the wrist joint using an x-ray stereophotogrammetric technique. A 3-dimensional coordinate software program calculated relative motion between bodies as screw axis displacement and rotation about each axis. Sectioning of the proximal and dorsal component of the LT ligament had little effect on carpal kinematics, but sectioning of the proximal and palmar components of the ligament resulted in flexion of both the lunate and triquetrum, producing a volar intercalated segment instability (VISI) pattern. The triquetrum supinated away from the lunate after sectioning of the entire LT ligament. Greater VISI occurred after sectioning the dorsal radiotriquetral and scaphotriquetral ligaments. Progressive destabilization of the LT joint results in increasing kinematic alterations; however, these may not exactly mimic the clinical situation. Moving the wrist through 1,000 cycles increased the instability. Dorsal repair of the LT ligament realigned the lunate and triquetrum, and LT fusion corrected triquetral supination. The latter, however, resulted in overcorrection into extension, which prevented a full wrist extension. The repair used may be insufficient to restore the palmar ligamentous integrity. Lunotriquetral arthodesis was difficult to simulate, providing some insight into the cause of clinical nonunions. Severe VISI is not correctable by repair or arthrodesis and requires further study using reconstructive procedures not discussed here.

Adult↗

Flexor tendon-pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro.

Ten cadaver digits were used to evaluate excursion resistance between a tendon and pulley after completing 4 methods of pulley reconstruction (Bunnell's, Kleinert's, Lister's, and Karev's techniques). Five tissues (palmaris longus tendon, extensor digitorum tendon, flexor digitorum superficialis tendon, extensor retinaculum, and volar plate) were used to reconstruct the A2 pulley. Intrasynovial tissue sources (extensor retinaculum, volar plate, and flexor digitorum superficialis tendon) produced less excursion resistance than extrasynovial tissue sources (extensor digitorum tendon and palmaris longus tendon). The models using the extensor retinaculum and volar plate as reconstructive materials produced less excursion resistance than the normal A2 pulley, whereas the models using the palmaris longus tendon produced the highest excursion resistance. Bunnell's technique of pulley reconstruction produced less excursion resistance than Kleinert's technique with all 3 tissues tested. The results of the in vitro study of excursion resistance between the tendon and reconstructed pulley demonstrated that Lister's technique of pulley reconstruction using the extensor retinaculum produced the least resistance to tendon gliding.

Biomechanical Phenomena↗

Excursion properties of tendon graft sources: interaction between tendon and A2 pulley.

We measured excursion resistance of 4 different tendons (flexor digitorum superficialis, the portion of the extensor indicis proprius tendon beneath the extensor retinaculum, the portion of the extensor indicis proprius tendon distal to the extensor retinaculum, and palmaris longus) beneath the A2 pulley. Intrasynovial tendons (i.e., flexor digitorum superficialis and the portion of the extensor indicis proprius beneath the extensor retinaculum) produced less excursion resistance than extrasynovial tendons (i.e., the portion of the extensor indicis proprius distal to the extensor retinaculum and palmaris longus). The excursion resistance of the intrasynovial portion of the extensor indicis proprius tendon was significantly lower than that of the extrasynovial portion of the same tendon. Intrasynovial tendons may be preferred to extrasynovial tendons when choosing a tendon graft source and graft gliding under a pulley is a consideration.

Aged↗

Flexor tendon-pulley interaction after annular pulley reconstruction: a biomechanical study in a dog model in vivo.

The excursion resistance between the canine flexor digitorum profundus tendon and A2 pulley was compared after pulley reconstruction using tendon grafts of either intrasynovial or extrasynovial origin at 10 days, 3 weeks, and 6 weeks after surgery. The changes over time in the underlying flexor digitorum profundus tendon after pulley reconstruction were also evaluated. The excursion resistance for both types of pulley reconstruction was significantly greater than that of the control group at all time periods. The excursion resistance of the extrasynovial tendon graft reconstruction was greater than that of intrasynovial pulley reconstruction at all time periods. In conclusion, pulley reconstruction with intrasynovial tendon grafts may facilitate tendon gliding after surgery.

Animals↗

Lateral closing wedge osteotomy for treatment of Kienböck's disease. A clinical and biomechanical study of the optimum correcting angle.

A retrospective clinical analysis of 20 patients who underwent a lateral closing wedge osteotomy of the radius as an adjuvant procedure to a radial recession in the treatment of Kienböck's disease is reported. The functional outcome is compared to the results of a simplified two-dimensional articulating force analysis (Rigid Body Spring Model) based on radiographs of the wrist of the same patients taken before and after surgery. At an average follow-up of 39 months, wrist function was excellent in 4 patients, good in 9, moderate in 6, and poor in one patient. A significant positive correlation between functional improvement and percent reduction of the calculated peak pressure at the radiolunate interval was found. This was maximal in patients with wedge osteotomies between 5 and 10 degrees.

Adolescent↗

Role of medical capsule and transverse metatarsal ligament in hallux valgus deformity.

The role of the medial capsule and transverse metatarsal ligament in hallux valgus deformity including stability of the first metatarsophalangeal and adjacent joints was investigated in vitro. The three-dimensional positions of the proximal phalanx, first metatarsal, and second metatarsal before and after sectioning the medial capsule and metatarsal ligament were measured using a magnetic tracking system. Valgus deformity of the hallux increased with medial capsule sectioning an average of 22.3 degrees +/- 6 degrees. Valgus deformity of the hallux increased with medial capsule and metatarsal ligament sectioning an average of 27.4 degrees +/- 9.1 degrees. Valgus deformity of the hallux did not change significantly after sectioning the metatarsal ligament only. No significant changes were found in varus and eversion of the first metatarsal, in valgus of the second metatarsal, in the distance between first and second metatarsal heads after sectioning the medial capsule, or in the metatarsal ligament. This study shows the importance of the medial capsule in hallux valgus deformity. The transverse ligament did not contribute substantially to cause the deformity.

Aged↗