Search PubMed⌕ Search

Biomedical subjects

K N An

Publications and source records attributed to K N An.

At least 55 records · Page 3Linked to original sources

IV immunoglobulin does not reverse established weakness in MS.

BACKGROUND: Immunoglobulin (Ig) administration induces remyelination in the Theiler's virus model of MS. METHODS: A randomized, double-blinded, placebo-controlled trial of IV immunoglobulin (IVIg) was performed in patients with MS who had persistent muscle weakness that had been stable for between 4 and 18 months to determine whether this would improve muscle strength (primary outcome: isometric muscle strength). Patients received either IVIg (0.4 g/kg) or placebo daily for 5 days, then single infusions every 2 weeks for 3 months (total, 11 infusions). Muscle groups identified by clinical measures to have unchanging significant weakness were the major targets for therapeutic response (targeted neurologic deficit [TND]). RESULTS: IVIg was well tolerated. An interim analysis after 67 patients were enrolled indicated no difference in the degree of change in strength between treatment groups in either the TND or non-TND muscle groups at 6 months, and the trial was terminated. There was no apparent benefit in relapse behavior or impairment measures during the 6-month observation period. Nor was there apparent benefit in either patients who remained clinically stable or in those with evidence of disease activity. Patients with active MS during the trial worsened in both TND and non-TND muscle groups. This worsening was seen regardless of whether the clinical manifestations of disease activity involved the TND muscle groups. CONCLUSIONS: IVIg does not reverse established weakness in MS. Measurements of isometric muscle strength were reliable (reproducible) indices of strength and may be sensitive, objective methods to document functional changes in impairment in future MS trials.

Adult↗

Differences in repositioning error among patients with low back pain compared with control subjects.

STUDY DESIGN: Trunk repositioning error was measured in 20 patients with chronic low back pain and 20 control subjects. OBJECTIVES: To measure trunk repositioning error as a method of measuring proprioception of the low back and to compare trunk repositioning error in patients with low back pain and in control subjects. SUMMARY OF BACKGROUND DATA: Although many current low back pain rehabilitation programs incorporate proprioceptive training, very little research has been performed on proprioception of the low back. METHODS: While standing with the legs and pelvis immobilized, the subject bent the trunk to a predetermined target position and then attempted to replicate the position. Repositioning error was calculated as the absolute difference between the actual target position and the subject-perceived target position. The multiple target positions in the frontal and sagittal planes were tested. Trunk position was measured with a 3Space Tracker, which analyzes the three-dimensional position of the body. RESULTS: Repositioning error in patients with low back pain was significantly higher than that of control subjects in flexion, and significantly lower than that of control subjects in extension. CONCLUSIONS: The increase in repositioning error of patients with low back pain during flexion implies that some aspects of proprioception are lost in patients with low back pain. The decrease in repositioning error in patients with low back pain in extension is not as easily explained, but could possibly be caused by increased activation of mechanoreceptors in facet joints.

Adult↗

Repositioning error in low back pain. Comparing trunk repositioning error in subjects with chronic low back pain and control subjects.

STUDY DESIGN: Repositioning error of the trunk was tested in 20 subjects with chronic low back pain and in 20 control subjects. The 3Space Tracker (Polhemus, Colchester, VT), a device that measures three-dimensional position in space, was used to determine the subject's trunk position. OBJECTIVES: To determine whether repositioning error is different in subjects with chronic low back pain than in control subjects. SUMMARY OF BACKGROUND DATA: Proprioception allows the body to maintain proper orientation during static and dynamic activities. In peripheral joint injuries, researchers have demonstrated a loss of some aspects of proprioception and improvement in outcome with retraining. Although the components of proprioception in subjects with low back pain have not been well studied, it is thought that these persons lose some elements of proprioception that can be measured in a quantifiable way. If so, then rehabilitation to improve these deficits is important. In this pilot study, one aspect of proprioception, repositioning error, was examined. METHODS: The subjects attempted to replicate target positions of the trunk in flexion, extension, lateral bending, and lateral rotation. Repositioning error was calculated as the absolute difference between the actual and the subject-replicated target positions. RESULTS: No significant difference was found in repositioning error between the control subjects and the persons with chronic low back pain. CONCLUSIONS: Because proprioception is complex and entails the use of many afferent receptors, it is difficult to measure any one afferent deficiency discretely. The authors believe that this study, in which one aspect of proprioception was measured in an indirect manner, provides important background information on low back position sense. Further studies analyzing aspects of proprioception in subjects with low back pain are recommended.

Adult↗

The effect of knot location, suture material, and suture size on the gliding resistance of flexor tendons.

The effect of knot location, suture material, and suture size on gliding resistance between the pulley and flexor tendon was investigated in a canine model. Different suture materials [monofilament nylon (Ethilon), braided polyester suture coated with silicone (Ticron) and uncoated braided polyester suture (Mersilene)] and suture sizes (4-0, 5-0) were tested. A knot was made on either the volar surface, on one lateral side, or on both lateral sides of canine hind-paw tendons, and gliding resistance was measured. In addition, the frictional coefficient between three suture materials (4-0 nylon, 4-0 Ticron, 4-0 Mersilene) and a nylon rod were measured. The gliding resistance of the tendon with knots on both sides was highest, while tendons with one lateral knot had the lowest resistance (p < 0.01). The gliding resistance of 4-0 suture size was higher than that of 5-0 size (p < 0.0001). The coefficient of friction of nylon was lower than that of braided polyester suture (Ticron or Mersilene) (p < 0.001). The placement of knots and choice of suture material affect gliding resistance after tendon repair, and may, therefore, have an effect on the result of tendon repair.

Animals↗

Structural properties of the subscapularis tendon.

The subscapularis muscle is an important mover and stabilizer of the glenohumeral joint. The purpose of this study was to measure regional variations in the structural properties of the subscapularis tendon in two joint positions. Subscapularis tendons from cadaveric shoulders were divided into four sections superiorly to inferiorly and tested to failure at 0 or 60 degrees of glenohumeral abduction. Arm position had a significant influence on stiffness in the inferior and superior portions (p < 0.05). The inferior region showed a higher stiffness in the hanging-arm position (0 degrees) than at 60 degrees of abduction (27.4+/-17.7 compared with 9.5+/-5.9 N/mm). Meanwhile, stiffness of the superior portion was higher at 60 degrees of abduction than in the hanging-arm position (208.7+/-60.9 compared with 147.2+/-32.3 N/mm). In the hanging-arm position (0 degrees) and at 60 degrees of abduction, the superior and midsuperior portions failed at significantly higher loads (superior: 623.2+/-198.6 and 478.2+/-206.6 N at 0 and 60 degrees of abduction, respectively; midsuperior: 706.2+/-164.6 and 598.4+/-268.4 N, respectively) than did the inferior portion (75.1+/-54.2 and 30.3+/-13.0 N, respectively). Likewise, stiffness of the superior and midsuperior portions was significantly higher than that of the inferior region in both positions. Higher stiffness and ultimate load in the superior tendon region may explain the infrequent extension of rotator cuff tears into the subscapularis tendon. Conversely, the significantly lower ultimate load and stiffness in the inferior tendon region could facilitate anterior dislocation of the humeral head when this portion stabilizes the joint in a dislocated position. Therefore, repair of torn inferior portions of the subscapularis tendon should be considered in surgery for glenohumeral instability.

Aged↗

Tendon-Defect and muscle-unloaded models for relating a rotator cuff tear to glenohumeral stability.

Rotator cuff tear and glenohumeral instability are closely related. Any tear may disturb muscle force generation due to pain inhibition. In addition, a full-thickness tear may foster instability by removing a structural element constraining the joint. It was hypothesized that the loss of both dynamic force and static constraint with a rotator cuff tear will affect glenohumeral stability. In a tendon-defect model, dynamic and static elements of the joint were sacrificed. In a muscle-unloaded model, only the dynamic element was removed. The location and size of the defect were also investigated. The effect on instability of a small tendon defect was less than that of muscle unloading, implying that a patient with a small tear would have less instability than a patient with weak or nonfunctioning supraspinatus and infraspinatus muscles. On the other hand, with a larger tear the defect had a greater effect than muscle-unloading because sectioning of the glenohumeral and coracohumeral ligaments was included in the model. Clinically, such a defect in the front is critical for anterior stability because it might insult the important anterior capsule ligamentous complex. Orthopaedic surgeons should pay attention, therefore, to the effect of possible associated lesions of static constraints based on the size and location of the tear in addition to the dynamic stabilizer.

Aged↗

Anatomy and biomechanics of the shoulder.

The anatomies and biomechanics of the glenohumeral joint and the scapulothoracic articulation are the subjects of this article. The anatomies of bones, joints, ligaments, and muscles are described in detail, and current biomechanical concepts concerning motion, stability, and force are presented. Morphologic and biomechanical changes in pathologic conditions briefly are described.

Biomechanical Phenomena↗

The manual stress test may not be sufficient to differentiate ankle ligament injuries.

OBJECTIVE: To assess the accuracy of stress tests (anterior drawer, talar tilt) in the diagnosis of lateral ligament injuries.Design. Stress tests were performed in vitro, and rotation and displacement of the calcaneus relative to the tibia were measured. BACKGROUND: Stress tests are commonly used to diagnose ankle injuries. However, it is controversial as to whether stress tests can accurately differentiate between isolated anterior talofibular ligament injuries and combined anterior talofibular and calcaneofibular ligament injuries. METHODS: Stress tests were performed in vitro under three conditions with both ligaments intact, after sectioning the anterior talofibular ligament, and after sectioning the anterior talofibular and calcaneofibular ligament. Motion of the calcaneus relative to the tibia was measured in neutral and in 20 degrees of plantarflexion at the ankle. RESULTS: There were statistically significant differences among cadavers, examiners and positions. There was a difference between isolated anterior talofibular ligament sectioning and combined anterior talofibular and calcaneofibular ligament sectioning in lateral tilt but not in anterior displacement. In contrast, a difference was found between intact and anterior talofibular ligament sectioned specimens in anterior displacement but not in lateral tilt. However the differences were not great enough to differentiate between the two conditions. CONCLUSIONS: Each of the stress tests provides reasonable hindfoot displacement but neither is sufficient for accurate diagnosis of specific ligament involvement due to the large amount of individual variation. RELEVANCE: Many clinicians rely on stress tests to diagnose lateral ligament injuries and to assess the extent of anatomic disruption. This in vitro study has demonstrated poor correlation between clinical stress tests and the degree of ligamentous disruption.

Aged↗

The relevance of the moment arm of shoulder muscles with respect to axial rotation of the glenohumeral joint in four positions.

OBJECTIVE: This study was undertaken to determine the efficiency of the shoulder girdle muscles during axial humeral rotation based on measurements of the moment arms. DESIGN: The instantaneous muscle moment arms of 10 shoulder muscles, including the three portions of the deltoid, the rotator cuff muscles, teres major, and the thoracohumeral muscle group, were measured during four specified glenohumeral rotations. BACKGROUND: Axial humeral rotation is a commonly performed movement during activities of daily living and is a targeted motion of shoulder rehabilitation, particularly in those protocols emphasizing rotator cuff strengthening. An understanding of the function of the movers and stabilizers of the shoulder requires such basic information of muscle moment arms. METHODS: The instantaneous moment arm values of the muscles were derived from the slope of the plot of tendon excursion versus glenohumeral joint rotation angle. Motion studied included axial rotation with the humerus elevated 90 degrees in the coronal, scapular, and sagittal planes, as well as in the neutral position with the arm at the side. RESULTS: Based on the findings, with the humerus in both neutral and elevated positions, the infraspinatus is potentially the most powerful external rotator, followed by teres minor and posterior deltoid. Subscapularis and possibly pectoralis major are the most effective internal rotators in this position. CONCLUSIONS: The moment arm in providing axial humeral rotation of 10 shoulder muscles in four planes were obtained. In general, the teres minor and infraspinatus had the largest moment arms in external rotation, and the subscapularis had the largest moment arm in internal rotation. The muscle function for axial humeral rotation was found to be modified by the plane of arm elevation. RELEVANCE: The data could be used for developing exercise programs in physical therapy.

Adult↗

The bursal and articular sides of the supraspinatus tendon have a different compressive stiffness.

OBJECTIVE: To measure the compressive stiffness of the supraspinatus tendon and to determine whether regional difference exists in the bursal and articular side of the tendon. DESIGN: Indentation testing was performed on both the bursal and articular sides of the supraspinatus tendon, focused on the 'critical area', where rotator cuff tears often occur. BACKGROUND: When the supraspinatus tendon wraps around the humeral head or is under impingement condition, compressive force on the tendon surface is expected. Therefore, compressive stress has been recently considered to be one of the important factors associated with the cuff tear. The mechanical properties would be essential for analytic modeling of stress distribution. METHODS: Indentation tests were performed at 15 locations on the bursal and articular surfaces of the supraspinatus tendon. A mathematical model with exponential relationship was used to describe the measured force-deformation relationship and to calculate the compressive stiffness of the supraspinatus tendon. RESULTS: The over-all initial stiffness on the bursal and articular sides of the tendon was significantly different. On the bursal side, the anterior third had a significantly higher initial stiffness than the other thirds on average. On the articular side, initial stiffness at location 10 mm proximal to the greater tuberosity was significantly higher than the rest on average. CONCLUSIONS: The compressive stiffness of the supraspinatus tendon was found to be non-homogenous throughout the structure.RelevanceNon-homogenous compressive stiffness of the supraspinatus tendon would affect the load transmission within the tendon, which might be associated with the potential mechanism of tear. Such characteristics needs to be considered when performing finite element modeling of stress fields in the tendon.

Aged↗

The influence of weakness in the vastus medialis oblique muscle on the patellofemoral joint: an in vitro biomechanical study.

OBJECTIVE: Investigation of the influence of weakness in the vastus medialis oblique muscle on patellar tracking. DESIGN: In vitro biomechanical study. BACKGROUND: Currently, the influence of weakness in the vastus medialis oblique muscle on patellar tracking has not been well understood. METHODS: Seven human cadaveric knees were used. The direction of loading forces in the rectus femoris/vastus intermedius, vastus medialis oblique, and the vastus lateralis muscles was decided by the muscle alignment of each cadaver knee measured at the time of dissection. The loads used were 60 N in the rectus femoris, 50 N in the vastus lateralis, and 40 N in the vastus medialis oblique, according to the ratio calculated from the cross-sectional study. The weakness of vastus medialis oblique was simulated at 30 N (75%), 20 N (50%), 10 N (25%), and 0 N (0%), and the patellar position was measured for each condition using a magnetic 3 Space Tracker System. The influence of weakness in the vastus medialis oblique muscle on patellar position was investigated with seven cadaver knees using a magnetic 3 Space Tracker System. RESULTS: At 0 degrees and 15 degrees of knee flexion, 75%, 50%, 25% and 0% of the normal vastus medialis oblique muscle led to a significant difference in lateral patellar shift compared to the normal (P<0.05). CONCLUSIONS: Weakness of the vastus medialis caused the patellar lateral shift at 0 degrees and 15 degrees of knee flexion. RELEVANCE: Weakness of the vastus medialis is thought to be an important factor causing patellar subluxation and dislocation. Understanding the relationship between the vastus medialis weakness and patellar tracking will be useful in diagnosis, treatment and prevention of patellar subluxation and dislocation.

Analysis of Variance↗

Mechanical properties of the posterior rotator cuff.

BACKGROUND: The infraspinatus is an important active and passive stabilizer of the glenohumeral joint. It functions as external rotator and participates in elevation of the arm. As its main posterior component, it is frequently involved in rotator cuff tears. OBJECTIVE: The purpose of this study was to determine the structural and mechanical properties of the infraspinatus tendon structure, including the midsubstance and insertion regions, in the superior, mid-superior, mid-inferior, and inferior portions, in two joint positions. METHODS: The infraspinatus tendons from 22 fresh frozen cadaver shoulders were divided into four strips. The tendons were held in a cryo-jaw and tested with a material-testing machine in 0 degrees or 60 degrees of glenohumeral abduction corresponding to 90 degrees arm abduction. Ultimate load, displacement and failure mode were recorded. Stiffness, ultimate stress and elastic modulus were calculated. RESULTS: Significant differences between glenohumeral abduction positions were detected only for the elastic modulus. The mid-superior (676.5 N, S.D. 231.0 N) and the inferior portion (549.9 N, S.D. 284.6 N) had the highest failure loads while the superior (462.8 N, S.D. 237.2 N) and the mid-inferior portions (315.3 N, S.D. 181.5 N) were weaker. Similar trends across the tendon strips were shown for stiffness, ultimate stress and elastic modulus. RELEVANCE: Position dependent changes in mechanical properties of the infraspinatus tendon probably do not play a role in the pathomechanism of posterior shoulder dislocation. Peaks in stiffness in mid-superior and inferior tendon sections explain the low incidence of posterior dislocations. The low ultimate failure loads in the superior portions might explain the frequent extension of rotator cuff ruptures into the infraspinatus tendon.

Aged↗

Material properties of the trapezial and trapeziometacarpal ligaments.

Destabilization of the trapezium from its normal orientation with respect to the trapezoid, second metacarpal, and thumb metacarpal leads to incongruity at the trapeziometacarpal (TMC) joint. Abnormal shear forces may eventually result in TMC joint arthritis. By determining the relative stiffness and strength of the ligaments that stabilize this joint, one may infer their role in providing stability to the TMC joint. This study addresses the material properties of the ligaments stabilizing the trapezium and TMC joint to better understand the mechanics and kinematics of this joint. Fresh-frozen cadaveric hands (10 males and 10 females) were used to obtain bone-ligament-bone complexes from the dorsal and volar trapeziotrapezoid ligaments, dorsal and volar trapezio-second metacarpal ligaments, anterior oblique ligament, dorsoradial ligament, and trapezio-third metacarpal (T-III MC) ligament. The following material properties were derived from our data: ultimate load, ultimate stress (normalized failure load), ultimate strain (percent elongation), stiffness, toughness (energy to failure), and hysteresis. The dorsoradial ligament demonstrated the greatest ultimate load and toughness (energy to failure). The T-III MC ligament demonstrated the greatest ultimate stress (normalized failure load) and stiffness. The anterior oblique ligament demonstrated the least stiffness and the greatest hysteresis. The material properties of capsuloligamentous structures may be a good indicator of their importance to joint stability. Using these criteria we conclude that the T-III MC and dorsoradial ligaments are important stabilizers of the trapezium and TMC joint, respectively. These two ligaments were found to be the strongest, stiffest, and toughest ligaments, while the anterior oblique ligament was relatively weak and compliant. The dorsal trapezio-second metacarpal, volar trapezio-second metacarpal, and T-III MC ligaments were all relatively strong and are anatomically aligned to function as tension bands to restrain the trapezium against cantilever bending forces applied to it by the thumb during key or tip pinch.

Aged↗

The dorsopalmar stability of the distal radioulnar joint.

Sixteen fresh-frozen adult human cadaveric upper extremities were used in a biomechanical analysis of distal radioulnar joint (DRUJ) stability. The relative contribution to stability of the DRUJ by the surrounding anatomic structures presumed to stabilize the joint was analyzed with respect to forearm rotation and wrist flexion and extension using a purpose-built 4-axis materials testing machine. The dominant structures stabilizing the DRUJ were the ligamentous components of the triangular fibrocartilage complex proper. The major constraint to dorsal translation of the distal ulna relative to the radius is the palmar radioulnar ligament. Palmar translation of the distal ulna relative to the radius is constrained primarily by the dorsal radioulnar ligament, with secondary constraint provided by the palmar radioulnar ligament and interosseous membrane. The ulnocarpal ligaments and extensor carpi ulnaris subsheath did not contribute significantly to DRUJ stability; however, approximately 20% of DRUJ constraint is provided by the articular contact of the radius and ulna. These relationships were consistent regardless of wrist position or degree of forearm rotation.

Adult↗

The A3 pulley.

The tendon-pulley geometry and gliding resistance with and without the A3 pulley were compared in 6 fresh human cadaver fingers. We measured the x-ray images of the distal A2 pulley-tendon angle and proximal A4 pulley-tendon angle with varying degrees of proximal interphalangeal joint flexion between 0 degrees and 120 degrees before and after A3 pulley resection. The gliding resistance of the flexor digitorum profundus tendon under the A2 pulley was also measured at varying tendon-pulley angles. With the A3 pulley removed, the tendon-pulley angle significantly increased compared with the A3 intact state. The gliding resistance between tendon and pulley quadratically increased as the tendon-pulley angle increase from 0 degrees to 60 degrees. These results indicate that the A3 pulley might serve to reduce tendon-pulley gliding resistance by reducing the tendon-pulley angle during finger flexion.

Biomechanical Phenomena↗

Kinematics of the proximal interphalangeal joint of the finger after surface replacement.

Nine fresh-frozen normal human cadaveric long fingers were used to compare the kinematics of the proximal interphalangeal joint (PIP) before and after a resurfacing metal-polyethylene prosthetic replacement (Avanta prosthesis, San Diego, CA) using the magnetic Isotrak system (Polhemus Navigational Systems, Colchester, VT). The kinematics of the PIP joint after replacement were similar to that of the normal joint. The maximum angular displacement was 5 degrees for lateral deviation and 9 degrees for rotation during the passive flexion and extension motion. The center of rotation after implant insertion was nearly identical to the center of rotation of the normal joint. This anatomically designed PIP prosthesis has potential to restore normal motion to the finger PIP joint while resisting physiologic out-of-plane forces such as pinch and grasp.

Arthroplasty, Replacement↗

Dynamic pressure transmission through agarose gels.

In biomedical research, agarose gel is widely used in tissue culture systems because it permits growing cells and tissues in a three-dimensional suspension. This is especially important in the application of tissue engineering concepts to cartilage repair because it supports the cartilage phenotype. Mechanical loading, especially compression, plays a fundamental role in the development and repair of cartilage. It would be advantageous to develop a system where cells and tissues could be subjected to compression so that their responses can be studied. There is currently no information on the pressure response of agarose gel when pressure is applied to the gas phase of a culture system. To understand the transmission of pressure through the gel, we set up an apparatus that would mimic an agarose suspension tissue culture system. This consisted of a sealed metal cylinder containing air as well as a layer of agarose submerged in culture medium. Pressure responses were recorded in the air, fluid, gel center, and gel periphery using various frequencies, pressures, gel volumes, and viscosities. Regression analyses show an almost perfect linear relation between gas and gel pressures (r(2) = 0.99987, p < 0.0001, f(x) = 0.9982 x - 0.0286). The pressure transmission was complete and immediate, throughout the range of the applied pressures, frequencies, volumes, and viscosities tested. Applying dynamic pressure to the gas phase results in reproducible pressure in the agarose and, therefore, validates the use of agarose tissue culture systems in studies employing dynamic pressurization in cartilage tissue engineering.

Gels↗

Biomechanical evaluation of occipital fixation.

Many studies have shown a positive correlation among screw pullout strength, screw insertional torque, bone thickness, and areal bone mineral density (BMD) measured by dual-energy X-ray absorptiometry. Variations are significant in the anatomy of the occipital bone. But no studies have correlated these variables with respect to the two locations commonly used for plate fixation to the occiput. The purpose of this study was to determine the thickness and quality of the occipital bone and to correlate these variables with the insertional torque of screws and the pullout strength of plates secured into two different locations on the occiput. The occiputs of 12 adult human fresh frozen cadaveric specimens were used. The specimens were analyzed by dual-energy X-ray absorptiometry. Direct thickness measurements of the occiput were performed. Areal and volumetric BMD were measured. A simple pelvic reconstruction plate (3.2 mm) was fixed to the occiput either laterally or at the midline with bicortical 4-mm cancellous screws. Torque was recorded at the time of insertion of each screw. Axial pullout tests were performed on all specimens. The peak load, failure load, stiffness, and energy to failure were recorded for each construct. Statistical analysis showed that the average thickness of occipital bone is greater in the midline than laterally. Occipital bone is thicker and screw torque is greater close to the inion. There is a positive correlation between bone thickness, areal BMD as measured by dual-energy X-ray absorptiometry, screw insertional torque, and strength of fixation. A plate fixed in the midline region of the occiput provides more rigid fixation than a plate fixed laterally. Areal BMD correlates better than volumetric BMD with bone thickness and is a reliable predictor of the strength of occipital fixation.

Absorptiometry, Photon↗