Search PubMed⌕ Search

Biomedical subjects

K Mizunuma

Publications and source records attributed to K Mizunuma.

At least 55 records · Page 3Linked to original sources

In vitro hydrolysis of methyl acetate, a limitation in application of head-space gas-chromatography in biological monitoring of exposure.

Stoichiometric conversion of methyl acetate to methanol in vitro was detected when methyl acetate was incubated with blood for 2 to 8 h. The velocity of the reaction was so fast that almost all of methyl acetate disappeared in 8 h. The methanol formation was further confirmed by means of gas-chromatography-mass spectrometry. The capacity to hydrolyze methyl acetate was evenly distributed in cellular and noncellular fractions of blood, but not in urine. The significance of the observation is discussed in relation to biological monitoring of exposure to industrial ester solvents by means of head-space gas-chromatography of blood samples.

Acetates↗

Curvi-linear relation between acetone in breathing zone air and acetone in urine among workers exposed to acetone vapor.

An occupational health study was conducted on 45 acetone-exposed male workers in combination with 343 non-exposed men to examine the quantitative relationship between the intensity of acetone vapor exposure and the concentration of acetone in urine. The time-weighted average acetone concentrations were measured by means of diffusive samplers with water as absorbent, whereas urine samples were collected at the end of the shift as well as before the shift on the next morning. Acetone concentration in shift-end urine did not increase when the workers were exposed to acetone up to approx. 15 ppm, and this was followed by a gradual increase at a higher atmospheric acetone concentration, in a manner dependent to acetone vapor concentration. The comparison in acetone concentrations between the urine samples collected at the shift-end and those before the shift of the next morning showed that the levels in two sets of samples were the same among those exposed to 15 or less ppm acetone, whereas acetone in the shift-end samples was significantly higher than the counterpart levels in the pre-shift samples among those exposed to acetone at more than 15 ppm.

Acetone↗

Urinalysis vs. blood analysis, as a tool for biological monitoring of solvent exposure.

Blood and urine samples were collected at the end of an 8-h workshift from 30 male workers exposed to a mixture of n-hexane, ethyl acetate and toluene (each being about 2 ppm as geometric means) and also from 20 nonexposed male workers. Blood samples were analyzed for n-hexane and toluene, and urine samples were analyzed for n-hexane, toluene, 2,5-hexanedione (both with and without hydrolysis) and hippuric acid. Based on the correlation between biological exposure indicators and solvent concentrations in air, sensitivity as an exposure indicator was compared between solvents in blood and solvents or metabolites in urine in terms of the lowest solvent concentration at which the exposed subjects can be statistically separated from the nonexposed. Both n-hexane and toluene in blood were sensitive enough to detect the exposure at 6.1 ppm and 1.4 ppm, respectively. n-Hexane exposure below 2 ppm was detectable also by urinalysis for 2,5-hexadione without hydrolysis. Urinary hippuric acid, however, failed to detect low toluene exposure under the conditions studied. Of additional interest is the fact that toluene in urine correlated significantly with toluene in air, which apparently deserves further study for confirmation.

Acetates↗

2-Acetylfuran, a confounder in urinalysis for 2,5-hexanedione as an n-hexane exposure indicator.

The apparent amount of 2,5-hexanedione, a biomarker of n-hexane expsoure in occupational health, in the urine of both exposed and non-exposed subjects varied not only as a function of the pH at which the urine sample was hydrolyzed but also depending on the capillary column used for gas chromatographic (GC) analysis of the urinary hydrolyzates after extraction with dichloromethane. The formation of a compound, identified by gas chromatography-mass spectrometry (GC-MS) as 2-acetylfuran, following acid hydrolysis was a major cause of confounding effects. This compound was hardly separated from 2.5-hexanedione on a capillary column such as DB-WAX, whereas separation could be achieved on a DB-1 capillary column. 2-Acetylfuran was formed when a urine sample was heated at a pH of less than 2 for hydrolysis, and the amount detected in urine did not differ between exposed and non-exposed subjects, indicating that the formation of 2-acetylfuran is independent of n-hexane exposure. When urinary hydrolysis is used, hydrolysis at a pH of less than 0.5, extraction with dichloromethane, and GC analysis on a non-polar capillary column are proposed to be the best analytical conditions for 2,5-hexanedione analysis in biological monitoring of exposure to n-hexane.

Confounding Factors, Epidemiologic↗

Methanol in urine as a biological indicator of occupational exposure to methanol vapor.

The exposure-excretion relationship and possible health effects of exposure to methanol vapor were studied in 33 exposed workers during the second half of 2 working weeks. Urinary methanol concentrations were also determined in 91 nonexposed subjects. The geometric mean value for methanol in urine samples from the latter was less than 2 mg/l (95% upper limit of normal, less than 5 mg/l) when log-normal distribution was assumed. Among the exposed workers, the methanol level in urine samples collected prior to the work shift exceeded the 95% upper limit of normal. The time-weighted average intensity of exposure to methanol vapor was measured using personal sampling devices (in which water severed as an absorbent) in 48 cases of methanol exposure (i.e., 2 of the 33 exposed workers failed to provide urine samples, whereas 17 subjects were examined twice). Methanol concentrations in urine were determined in samples collected at the end of the shift from the 48 exposed cases as well as from 30 nonexposed controls. There was a significant correlation between the exposure to methanol vapor at concentrations of up to 5,500 ppm and the levels of methanol measured in the shift-end urine samples. The calculation indicated that a mean level of 42 mg methanol/l urine (95% confidence range, 26-60 mg/kg) was excreted in the shift-end urine sample following 8 h exposure to methanol at 200 ppm (the current occupational exposure limit). Dimmed vision and nasal irritation were among the most frequent symptoms complained during work. Three cases showing clinical signs of borderline significance were identified.

Adult↗

Dose-dependent increase in 2,5-hexanedione in the urine of workers exposed to n-hexane.

The concentrations of 2,5-hexanedione (2,5-HD), an n-hexane metabolite, and 2-acetylfuran (2-AF) were measured in urine samples from 123 workers who had predominantly been exposed to n-hexane vapor and 53 workers who had experienced no exposure to solvents. The time-weighted average intensity of exposure to n-hexane vapor was determined by a diffusive sampling method. For biological monitoring of exposure, urine samples were collected late in the afternoon during the second half of a working week and were analyzed in the presence and absence of acid hydrolysis (at pH less than 0.5) for 2,5-HD and 2-AF by gas chromatography on a nonpolar capillary DB-1 column. The urinary 2,5-HD concentration increased as a linear function of the intensity of exposure to n-hexane, showing a correlation coefficient of 0.64-0.77 after acid hydrolysis and that of 0.73-0.83 in the absence of hydrolysis, depending on the correction for urinary density (P less than 0.01 in all cases, with no improvement in the coefficient occurring after the corrections). In contrast, 2-AF levels were independent of n-hexane exposure. The geometric mean 2,5-HD concentration in urine samples from 53 nonexposed men was 0.26 mg/l as observed (i.e., with no correction), 0.19 mg/l after correction for a urinary specific gravity of 1.016, and 0.23 mg/g creatinine after correction for creatinine concentration, and the geometric standard deviation was approximately 2.

Chromatography, Gas↗

Urinary methylhippuric acid isomer levels after occupational exposure to a xylene mixture.

The quantitative relationship between exposure to xylene vapor and urinary excretion of methylhippuric acid (MHA) isomers were studied in the second half of a working week. The participants in the study were 121 male workers engaged in dip-coating of metal parts who were predominantly exposed to three xylene isomers. The intensity of exposure measured by diffusive sampling during an 8-h shift was such that the geometric mean vapor concentration was 3.8 ppm for xylenes (0.8 ppm for o-xylene, 2.1 ppm for m-xylene, and 0.9 ppm for p-xylene), 0.8 ppm for toluene, and 0.9 ppm for ethylbenzene. Urine samples were collected at the end of the shift and analyzed for metabolities by HPLC. The statistical analysis showed that there is a linear relationship between the intensity of exposure to xylenes and the concentration of MHA in urine, that the regression line passes very close to the origin, and that the increment in observed (i.e., noncorrected) MHA concentrations as a function of increasing xylene concentration was 17.8 mg x l-1 ppm-1. Further examination on the basis on individual xylene isomers showed that the slopes of the regression lines for o- and m-isomers were similar (i.e., 17.1 and 16.6 mg l-1 ppm-1, respectively), whereas that for p-xylene was larger (21.3 mg l-1 ppm-1).

Air Pollutants, Occupational↗

The method of choice for the determination of 2,5-hexanedione as an indicator of occupational exposure to n-hexane.

To identify the method of choice for analysis of urine for 2,5-hexanedione (2,5-HD) as an indicator of occupational exposure to n-hexane, the end-of-shift urine samples of 36 n-hexane exposed male workers and 30 non-exposed male workers were analyzed for 2,5-HD under three conditions of hydrolysis, i.e. enzymic hydrolysis at pH 4.8, acid hydrolysis at pH 0.5, and without hydrolysis. The 2,5-HD concentrations thus determined were examined for correlation with 8-h, time-weighted average exposure concentrations of n-hexane measured by diffusive sampling. The regression analysis showed that the 2,5-HD concentrations without any hydrolysis correlated best with the intensity of exposure to n-hexane. No 2,5-HD was detected in the urine of the non-exposed subjects under the analytical conditions with no hydrolysis. Thus, the analysis without hydrolysis was considered to be the method of choice from the viewpoint of simplicity in analytical procedures, sensitive separation of the exposed from the non-exposed, and quantitative increase in the amount of 2,5-HD after n-hexane exposure.

Environmental Monitoring↗

[CT of abdominal blunt trauma].

We studied CT findings and Interventional Radiology including therapeutic procedures in 43 cases with abdominal blunt trauma, retrospectively. All of parenchymal organ's injuries, and injuries of duodenum & retroperitoneum were correctly diagnosed by CT. In 14 cases with only hemoperitoneum or no positive findings on CT, 4 cases were jejunal perforations, and remaining 10 cases were conservatively treated and relieved. We have to take care that the similar CT findings include the opposite results to need surgery and not.

Abdominal Injuries↗

Ultrasonographic findings in gastric cancer: in vitro and in vivo studies.

Ultrasonography was performed in 45 cases of gastric cancer. Specimens from all 45 cases of gastric cancer were subjects to ultrasonographic study by the water immersion method for comparison with histology. In 32 of these 45 cases in vivo ultrasonographic evaluation was performed prospectively. The overall accuracy rates for the diagnosis of the depth of cancerous invasion were almost 80% in both in vitro and in vivo studies. In vivo ultrasonographic findings agreed well with those from the specimen studies. Ultrasonography was considered to be useful in the diagnosis of gastric malignancies.

Humans↗