Search PubMed⌕ Search

Biomedical subjects

K Miyaji

Publications and source records attributed to K Miyaji.

At least 55 records · Page 3Linked to original sources

Association of the serum leptin concentration with weight loss in chronic hemodialysis patients.

Circulating leptin, which is partly cleared by the kidney, has been reported to increase with chronic renal failure and thus may play a role in the weight loss of patients with chronic renal failure. We investigated the association of body weight loss with the serum leptin concentration in Japanese hemodialysis patients. The relationship between serum leptin and the body mass index (BMI) or body fat mass was compared among 181 patients undergoing hemodialysis and 185 control subjects. There was no difference in the serum leptin concentration between the hemodialysis patients (HD) and controls (C) for either the men (3.9 +/- 0.2 ng/mL for HD, n=117; 3.9 +/- 0.3 ng/mL for C, n=89; NS) or women (8.9 +/- 1.2 ng/mL for HD, n=64; 7.4 +/- 0.5 ng/mL for C, n=96; NS), whereas BMI of the hemodialysis patients was significantly lower than that of the controls for both the men (20.1 +/- 0.2 kg/m2 for HD, 22.4 +/- 0.3 kg/m2 for C, P < 0.001) and women (19.2 +/- 0.3 kg/m2 for HD, 22.0 +/- 0.4 kg/m2 for C, P < 0.001). The serum leptin/body fat mass ratio was significantly correlated with the weight change of the patients during a follow-up evaluation period of 17 months (r = -0.37, P < 0.05 for men, n=27 and r = -0.53, P < 0.005 for women, n=28), indicating the possibility that a relatively high level of serum leptin had induced weight loss in the hemodialysis patients. The serum leptin/body fat mass ratio also showed a significant inverse correlation with the duration of hemodialysis (r = -0.31, P < 0.05 for men and r = -0.49, P < 0.05 for women). A multiple regression analysis indicated that the body fat mass was significantly correlated with serum leptin concentration, whereas the fat distribution did not have any relationship with leptin. These data indicate that a high level of serum leptin relative to the body fat mass might be associated with weight loss in long-term hemodialysis patients. The serum leptin level relative to the body fat mass also seems to have been affected by the duration of hemodialysis.

Adipose Tissue↗

Activation of protein kinases in canine basilar artery in vasospasm.

Subarachnoid hemorrhage (SAH) often leads to a long-term narrowing of cerebra! artery called vasospasm. To understand the molecular mechanisms in vasospasm, signal transduction of tyrosine kinase pathway and phosphorylation of myosin light chain (MLC) and calponin (CaP) in the basilar artery were studied. Vasospasm was produced in the canine basilar artery by a two-hemorrhage method, and vasocontraction was induced by a local application of KCI or serotonin to the basilar artery after a transclival exposure. Intracellular substrates of tyrosine kinase pathway, including Shc, Rafl, and extracellular-regulated kinases in the basilar artery, were activated after SAH, and the activation of Shc suggests stimulation of signal transductions from tyrosine kinase receptors, G-coupled receptors, or both. The activation of tyrosine kinase pathway in vasospasm also was supported by dose-dependent dilation of the spastic basilar artery on days 0 and 7 by topical application of genistein, a tyrosine kinase inhibitor, and associated marked inhibition of tyrosine phosphorylation of intracellular substrates, including Shc. In addition, the generation of protein kinase M, catalytic fragment of protein kinase C(alpha) (PKC alpha), in vasospasm on days 0 and 7 was inhibited in response to genistein, indicating an inactivation of mu-calpain. It is suggested, therefore, that the reversal of vasospasm by genistein is closely associated with the restoration of intracellular Ca2+ levels. However, the increased activities of Raf1 and extracellular-regulated kinases in vasospasm were declined on day 7 compared with those on day 0 or 2, suggesting that the activation of tyrosine kinase pathway is more closely associated with the early stage of vasospasm than with the late stage of vasospasm. The analysis by pyrophosphate polyacrylamide gel electrophoresis (PPi-PAGE) demonstrated three MLC bands in vasospasm on days 2 and 7, as well as in KCI- and serotonin-induced vasocontraction. Since PPi-PAGE resolves smooth muscle MLC into three bands in the MLC kinase (MLCK)-mediated phosphorylation and into a single band in the PKC-mediated phosphorylation based on the phosphorylation state, the current results suggest that MLC in vasospasm is phosphorylated by MLCK but not by PKC. In basilar artery, CaP was significantly down-regulated, and in addition, significantly phosphorylated on serine and threonine residues only in vasospasm on days 2 and 7. Although the significance of CaP phosphorylations in vivo still is controversial, CaP down-regulation and phosphorylation may attenuate the inhibition of Mg(2+)-ATPase activity by CaP and induce a potential enhancement of smooth muscle contractility in delayed vasospasm. Since CaP is phosphorylated in vivo by PKC, activated PKC in vasospasm may phosphorylate CaP. Thus, SAH stimulates tyrosine kinase pathway to increase intracellular Ca2+ and activate PKC, and the former activates MLCK to phosphorylate MLC, whereas the latter phosphorylates CaP but not MLC.

Animals↗

Sildenafil induced priapism.

A 53 year-old Japanese man was referred to our hospital for persistent priapism, which had been induced by 200 mg (usual dose 25-50 mg) of sildenafil citrate (Viagra) three days earlier. He had a history of erectile dysfunction and had undergone penile injection therapy elsewhere; however, he had not used injection therapy this time. He obtained sildenafil personally without a doctor's prescription. He had not taken any other drugs that affect the metabolism of sildenafil, nor did he have any medical complications that might induce priapism. Since needle aspiration and irrigation were ineffective as first line therapy, surgical treatment was indicated to relieve the condition; a incision of tunica albuginea of both corpora cavernosa was made, and vigorous irrigation of saline washed out the blood clots. This is the first case report of priapism induced by sildenafil. Although this drug can be obtained through private commerce, it should be used under professional guidance as its abuse may lead to severe morbidity.

Humans↗

Gliosarcoma with angiosarcomatous features: a case report.

A surgical case of gliosarcoma in which the mesenchymal component showed angiosarcomatous features is reported. The neoplasm was extirpated from the right cerebral hemisphere of a 76-year-old man who presented with left hemiparesis and headache, and it was composed of both anaplastic astrocytomatous and sarcomatous elements. The sarcomatous element was composed of a proliferation of atypical endothelial cells that had pleomorphic, mitotically active nuclei and formed vascular lumina of irregular shapes or solid cellular sheets, and was accompanied by the deposition of collagenous matrix. The cytoplasm of some of the atypical endothelial cells was immunohistochemically positive for vimentin, factor VIII-related antigen, CD 34, and thrombomodulin. The MIB-1 labeling index of the sarcomatous component was higher than that of the astrocytomatous component.

Aged↗

Myocardial tactile stiffness: a variable of regional myocardial function.

OBJECTIVES: We developed a new sensor system for in situ measurement of myocardial tactile stiffness-stiffness in a direction perpendicular to the wall-and validated its use for providing a reasonable estimation of regional myocardial function. BACKGROUND: Numerous attempts have been made to directly assess regional myocardial function. The complexity and highly invasive nature of the measuring devices have hampered their in situ application. METHODS: In open chest mongrel dogs, myocardial tactile stiffness, ventricular pressure and ventricular volume were monitored. Under the preload reduction, these variables were measured to determine the relation between the end-systolic pressure-volume relation (ESPVR) and the end-systolic tactile stiffness-volume relation (ESSVR). The changes in myocardial tactile stiffness were monitored in the regional ischemic myocardial model and infarcted model to evaluate their usefulness as indexes of regional myocardial function. RESULTS: Myocardial tactile stiffness changed cyclically and followed a time course similar to left ventricular pressure. When preload was altered, the ESSVR was as linear as the ESPVR. The slope of the ESSVR and that of the ESPVR showed a strong correlation over a wide range of contractility. These results suggest that myocardial tactile stiffness can be a good index of regional wall stress or fiber stress. End-systolic myocardial tactile stiffness of ischemic and infarcted regions decreased significantly, with a concomitant increase in end-diastolic stiffness compared with that of intact myocardium. CONCLUSIONS: Using our tactile sensor system, regional myocardial tactile stiffness of a beating heart was measured with reasonable temporal resolution. We consider myocardial tactile stiffness to be a useful index of regional myocardial function.

Animals↗

Interleukin-6 may mediate malnutrition in chronic hemodialysis patients.

Studies were performed to investigate the relationship between serum interleukin-6 (IL-6) and the nutritional status in chronic hemodialysis patients. Serum IL-6 in 45 patients (21 men and 24 women), each with chronic renal failure and having undergone hemodialysis for more than 3 years, was measured before and after a dialysis session. The nutritional status of each patient was evaluated by measuring body mass index (BMI), body weight loss for 3 years, midarm muscle area (MAMA), serum albumin, prealbumin, and insulin-like growth factor-1. Serum IL-6 was significantly higher in the patients undergoing hemodialysis (11.7 +/- 2.8 pg/mL) than in healthy volunteers (< 0.6 pg/mL). There was no further increase in serum IL-6 after a dialysis session when the extracellular water volume was corrected by the ultrafiltrate volume. Predialytic serum IL-6 was significantly correlated with serum albumin (r = -0.4, P = 0.006), cholinesterase (r = -0.51, P = 0.001), body weight change for 3 years (r = -0.48, P = 0.001) and MAMA r = -0.39, P = 0.05). With the patients divided into two groups, a high serum IL-6 (>10 pg/mL) group and low serum IL-6 (<10 pg/mL) group, the body weight loss for 3 years (-4.60% +/- 1.39% v 0.76 +/- 0.75%, P < 0.01) was significantly higher, and the serum albumin level (3.66 +/- 0.10 g/dL v 3.96 +/- 0.05 g/dL, P < 0.05) was significantly lower in those patients with high serum IL-6 than in those with low serum IL-6. The results of a multiple regression analysis indicated that the serum IL-6 level was dependent on the duration of hemodialysis, age, and the dialysis membrane properties. These results suggest that the nutritional status in chronic hemodialysis patients was affected, at least in part, by the circulating IL-6 level. Multiple factors, such as long-term hemodialysis, aging, and the use of a regenerated cellulose membrane dialyzer, were associated with this increased level of IL-6.

Biocompatible Materials↗

[Thoracoscopic decortication for chronic empyema thoracis: report of a case].

Thoracoscopic surgery for empyema thoracis treatment is still uncommon in Japan. We report a case of chronic empyema thoracis which was successfully treated with decortication through thoracoscopy. A 63-year-old man presented with respiratory distress, appetite loss and hoarseness. He had been suffering from diabetes mellitus for 13 months. His chest X-ray film revealed that he had suffered from the left chronic empyema. As the decortication procedure was feasible at the preliminary exploration, it was then performed through the thoracoscopy. The lung re-expanded well after the pleural peel was removed. His chest drainage tube was drawn out on 19th postoperative day.

Chronic Disease↗

Overweight as another nutritional risk factor for the long-term survival of non-diabetic hemodialysis patients.

OBJECTIVE: Studies were performed to investigate the association of the body mass index (BMI) with long-term survival of non-diabetic hemodialysis patients who were monitored for up to 12 years. METHODS: In 116 patients having undergone hemodialysis in 1984, a Kaplan-Meier survival analysis was performed, and a proportional hazard model was applied to calculate the relative risk of mortality in body mass index quintiles. RESULTS: Those patients with BMI of less than 16.9 kg/m2 and more than 23.0 kg/m2 showed lowered survival relative to the patients with BMI of 17.0-18.9 kg/m2. A proportional hazard model revealed that the patients with BMI of less than 16.9 kg/m2 had the highest risk of mortality independent of age, gender, smoking, duration of hemodialysis, serum albumin, blood pressure and urea reduction rate. Those patients with BMI of over 19.0 kg/m2 also had a high risk of mortality which was progressively elevated with increasing BMI. This higher risk of mortality in those patients with high BMI was associated with such atherosclerotic risk factors as low HDL-cholesterol and high total-/HDL-cholesterol ratio. The number of hospitalizations showed a similar trend to mortality in the body mass index quintiles. The survivors lost their body weight slightly but significantly for 12 years, although there were no significant changes in serum albumin and creatinine. Serum albumin, prealbumin and IGF-1 were within normal range in 1996, suggesting that the survivors did not exhibit severe malnutrition. CONCLUSIONS: These results suggest that long-term survival could be attained by patients with relatively low BMI who have no serious nutritional problems. Nutritional intervention might be required in the overweight patients, in addition to extremely lean patients.

Body Mass Index↗

The stiffness of lymph nodes containing lung carcinoma metastases: a new diagnostic parameter measured by a tactile sensor.

BACKGROUND: It is believed that the stiffness or hardness of a lymph node containing a metastasis differs from that of lymph node without a metastasis because of the difference in tissue density, which is derived from the lymph node's histopathologic features. Prior to this study, however, there had been no attempts to quantify the hardness or stiffness of lymph nodes. The authors developed a new tactile sensor and system for measuring the stiffness (g/cm) of lymph nodes accurately, and they studied its utility as a tool for diagnosing lymph node metastases. METHODS: Clinical specimens were obtained from 14 patients who underwent lobectomy or pneumonectomy with hilar and mediastinal lymph node dissection for nonsmall cell lung carcinoma at the University of Tokyo between January and July 1996. With the tactile sensor developed by the authors, 212 resected lymph nodes were measured for their stiffness. RESULTS: Among these 212 resected lymph nodes, 57 were diagnosed as containing metastases (38 from adenocarcinomas and 19 from squamous cell carcinomas). The mean stiffness of the lymph nodes that contained metastases was 3.35 +/- 1.57 g/cm, and that of lymph nodes without metastases was 1.23 +/- 0.50 g/cm (P < 0.001). Receiver operating characteristic analysis revealed that the area under the curve was 0.93, indicating excellent accuracy of the method. When the cutoff was 1.5 g/cm, the sensitivity was 91.2% and the specificity was 78.1% for detection of lymph node metastases. CONCLUSIONS: Measurement of the stiffness of resected lymph nodes was confirmed as an accurate approach to diagnosing lymph node metastases without knowledge of other factors, such as lymph node size or color.

Aged↗

Fibrous tissue overgrowth and prosthetic valve endocarditis: report of a case.

Mechanical valve stenosis without restricted occluder motion and paravaluvular leakage developed in a patient who had undergone patch closure of partial atrioventricular septal defect and replacement of the left atrioventricular valve 13 years previously. Dense calcification of the supravalvular region was shown in a cineradiogram, whereas transthoracic and transesophageal echocardiography failed to reveal any obstructive mechanism. Elevated transprosthetic pressure gradient with unrestricted occluder motion suggested prosthetic valve stenosis resulting from fibrous tissue overgrowth, although this was not visualized by the modern diagnostic imaging tools. Reoperation confirmed calcified fibrous tissue overgrowth obstructing the mechanical valve inflow. Examination of resected tissue revealed prosthetic valve endocarditis due to alpha-streptococcus. Paravalvular leakage accompanying fibrous tissue overgrowth may indicate the presence of prosthetic valve infection even if the clinical manifestations are scarce.

Calcinosis↗

Surgical repair for atrial septal defect in patients over 70 years of age.

Atrial septal defect (ASD) is the most common congenital heart anomaly encountered in adults. For patients over 60 years old, acceptable operative mortality and symptomatic improvement following surgery have been reported. We reviewed patients with ASD aged over 70 years and studied their preoperative hemodynamics, the surgical procedures used and the results. Between January 1994 and December 1996, 18 patients over the age of 40 years underwent surgical repair of ASD. Four patients were over 70 years of age (Group A). The other 14 patients were studied as a control group (Group B). We compared the preoperative clinical status, hemodynamic data, and surgical results between the two groups. The postoperative clinical status of Group A was studied during the follow-up period. The NYHA functional class of the elderly patients was greater than that of the middle-aged patients. None of the elderly patients had pulmonary hypertension. Moderate or severe tricuspid valve regurgitation (TR) due to annular dilatation was found, and tricuspid annuloplasty was performed in all four elderly patients. There were no operative or hospital deaths in either group. The NYHA functional class and TR improved in all the aged patients after surgery. In order to prevent progressive tricuspid annular dilatation due to an intraatrial left to right shunt, surgical closure of ASD should be performed for physically active adult patients.

Adult↗

Regional myocardial stiffness measured by a new tactile sensor system.

Numerous investigators have attempted to measure regional wall stress directly. However, the measurement systems and devices employed have been too complex for accurate quantification in situ. We have developed a new tactile sensor system for measuring accurately myocardial stiffness in situ and validated its use for estimation of myocardial contractile function. The tactile sensor was placed on the left ventricle of five mongrel dogs, (weighing 12-17 kg) and myocardial stiffness (g/mm2) was measured. Dobutamine (5.0 micrograms/kg/min) and propranolol (0.25 mg/kg) were sequentially administrated intravenously, and the change in myocardial stiffness was monitored. Myocardial stiffness followed a time course similar to that of left ventricular pressure, indicating a close relationship with wall stress. Baseline end-systolic stiffness in 5 dogs was 2.38 +/- 0.19 g/mm2. After administration of dobutamine, end-systolic stiffness increased to 3.26 +/- 0.32 g/mm2 (p < 0.01). After the administration of propranolol, end-systolic stiffness decreased significantly to 1.83 +/- 0.19 g/mm2 (p < 0.01), compared with the baseline values. Regional myocardial stiffness of a beating heart can be measured precisely using our new tactile sensor system. End-systolic stiffness is a useful index for accurate quantification of the regional myocardial contractile state.

Animals↗

Mitral valve repair with extensive resection of the anterior leaflet for regurgitation due to Barlow's disease. Report of a case.

We recently performed mitral valve repair for a case of mitral regurgitation due to Barlow's disease, which is relatively rare in Japan. Both the anterior and posterior leaflets were affected by advanced myxomatous change, and appeared markedly thickened and redundant. Although extensive resection of the anterior leaflet is not a generally accepted method, nearly one fourth of the anterior leaflet was resected in this case. Now, at 36 months after the operation, there is only trivial regurgitation and the patient is doing well and without symptoms. We believe that extensive resection of the anterior leaflet can be a useful treatment for repair of a redundant anterior leaflet with excess tissue.

Cardiac Surgical Procedures↗

Tactile sensor method for thoracoscopic detection of intrapulmonary nodules.

We have developed a tactile sensor which can be used to quantify the hardness of objects and applied it to thoracoscopic surgery for the localization of small invisible nodules in the lung. The hardness properties of objects can be obtained as changes in the resonance frequency of the tactile sensor (delta f). When the sensor probe is moved over the lung surface, a delta f curve is depicted on the computer screen. When the sensor tip passes the area just above a target nodule, a spike is evoked in the delta f curve. In thoracoscopic surgery, tactile sensor was employed to detect a total or 42 nodules, 32 indeterminate and 10 metastatic, in 37 patients. All except two of these detected nodules, had been preoperatively demonstrated with computed tomography. Each nodule was detected successfully by recognizing the spot on the pleura, at which the spike of delta f curve was evoked, and resected thoracoscopically. All of the indeterminate nodules were diagnosed intraoperatively; 28 benign tumors and 4 primary carcinomas. In conclusion, our tactile sensor method can be a viable alternative for thoracoscopic detection of small and invisible pulmonary nodules.

Humans↗

Usefulness of pulsatile bidirectional cavopulmonary shunt in high-risk Fontan patients.

BACKGROUND: A bidirectional cavopulmonary shunt has been performed for the high-risk Fontan patient. It is well known that in the presence of the bidirectional cavopulmonary shunt alone to secure pulmonary blood flow, the central pulmonary artery size decreases over time. We have performed pulsatile bidirectional cavopulmonary shunt (PBCPS), keeping pulmonary blood flow from the ventricle through the stenotic pulmonary valve, or a Blalock-Taussig shunt in patients who do not meet the criteria for the Fontan operation. METHODS: Eleven patients who underwent PBCPS between 1989 and 1993 were reviewed. We compared the results of cardiac catheterization immediately before PBCPS and during the postoperative observation period (310 +/- 257 days). RESULTS: Pulmonary blood flow and arterial oxygen saturation increased significantly after PBCPS (p = 0.01). Pulmonary artery area index showed a tendency to increase (p = 0.11). The mean number of risk factors for the Fontan procedure decreased significantly for 1.8 +/- 1.1 to 0.7 +/- 0.8 after PBCPS (p < 0.05). Overall, 5 of the 11 patients (45.5%) met the criteria for the Fontan procedure, and a fenestrated Fontan procedure was carried out in 4 of them. CONCLUSIONS: The PBCPS is useful for high-risk Fontan patients not only in the staged Fontan operation, but also as definitive palliation.

Child↗

Mid-term result of one and one half ventricular repair in a patient with pulmonary atresia and intact ventricular septum.

A 10-year-old girl was referred to us with a diagnosis of pulmonary atresia and intact ventricular septum with a severely hypoplastic right ventricle and atrial septal defect. Her tricuspid valve diameter (TVD) was 48.5% of normal, with a TVD Z-score of -6.7, while right ventricular end-diastolic volume was 53.4% of normal. As a definitive procedure, one and one half ventricular repair using a bidirectional cavopulmonary shunt (BCPS) was performed instead of a Fontan procedure. The postoperative course was uneventful without episodes of low cardiac output or elevated right atrial pressure. She has been doing well during a follow-up period of 3 years.

Cardiac Surgical Procedures↗

Successful conduit repair using aortic homograft in a Jehovah's Witness child.

A 10-year-old female child of the Jehovah's Witness faith presented with congenitally corrected transposition of the great arteries (S,L,L), pulmonary atresia, and a ventricular septal defect. A successful surgical correction was performed using an aortic homograft as a valved extracardiac conduit without the use of homologous blood or blood products. We used permanent splinting of the sternum with a methyl methacrylate resin plate to prevent compression of the conduit.

Aorta↗

[Echocardiographic evaluation of hemodynamic function of CarboMedics heart valve in the aortic position in patients with small aortic annuli].

Hemodynamic parameter of CarboMedics heart valve in the aortic position was evaluated using Doppler echocardiography in 46 patients with small aortic annuli. The size of prosthetic valve were 19 mm in 6 cases, 21 mm in 15 and 23 mm in 25. In patients with 19 mm valve, trans-valvular peak pressure gradient was 42.2 +/- 11.8 mmHg, mean pressure gradient was 17.3 +/- 9.3 mmHg, and left ventricular systolic pressure was 174 +/- 12 mmHg. These values were significantly larger than those of the other two groups. Effective orifice area index, discharge coefficient, doppler velocity index and stroke volume showed no significant difference among each group. After aortic valve replacement for aortic stenosis, left ventricular mass decreased to around 70% of preoperative value in all groups, but significant left ventricular hypertrophy remained at two years postoperatively. We conclude that hemodynamic performance of CarboMedics heart valve in the aortic position was satisfactory, although 19 mm valve seemed to be fairly small for adult patients and deliberate patient selection is necessary.

Adult↗