Generation and use of measurement-based 3-D dose distributions for 3-D dose calculation verification.

A 3-D radiation therapy treatment planning system calculates dose to an entire volume of points and therefore requires a 3-D distribution of measured dose values for quality assurance and dose calculation verification. To measure such a volumetric distribution with a scanning ion chamber is prohibitively time consuming. A method is presented for the generation of a 3-D grid of dose values based on beam's-eye-view (BEV) film dosimetry. For each field configuration of interest, a set of BEV films at different depths is obtained and digitized, and the optical densities are converted to dose. To reduce inaccuracies associated with film measurement of megavoltage photon depth doses, doses on the different planes are normalized using an ion-chamber measurement of the depth dose. A 3-D grid of dose values is created by interpolation between BEV planes along divergent beam rays. This matrix of measurement-based dose values can then be compared to calculations over the entire volume of interest. This method is demonstrated for three different field configurations. Accuracy of the film-measured dose values is determined by 1-D and 2-D comparisons with ion chamber measurements. Film and ion chamber measurements agree within 2% in the central field regions and within 2.0 mm in the penumbral regions.

Humans↗

Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers.

Patient positioning accuracy can be quantified by the three-dimensional (3-D) translations and rotations required to transform the patient back to the desired position. Results of the current study show that the translations and rotations could be obtained from two projection images obtained radiographically on a linear accelerator when spherical radio-opaque markers were implanted inside or affixed to the surface of a skull phantom. In this study, film used to record the images were converted into digital gray scale images using a laser film digitizer. The marker images were located automatically by the computer using image processing techniques. By combining information from both projections, the 3-D locations of the markers were determined to submillimeter precision. Pairs of films were also analyzed for the phantom displaced from its original location by known amounts. The accuracy of the computed translations and rotations required for realignment of the phantom were found to be better than 1 mm and 0.3 degrees, respectively; comparable to the accuracy of the readout system of the equipment used. The general methodology could be coupled with an electronic portal imaging device for use in computer aided or automated correction of patient position in radiotherapy.

Algorithms↗