Search PubMedSearch

Biomedical subjects

K L Boundy

Publications and source records attributed to K L Boundy.

4 recordsLinked to original sources

Magnetic resonance imaging in carotid dissection.

Magnetic Resonance Imaging was performed in two cases of suspected internal carotid artery dissection. In both cases it was possible to demonstrate the dissection. It is suggested that magnetic resonance imaging (MRI) could replace more invasive techniques in the diagnosis of this condition.

Adult

Interoperator variability in quantitative electroencephalography.

The purpose of the study was to determine whether quantitative or discriminant analysis of the electroencephalograph (EEG) would vary significantly when the same EEG was analysed by 3 different operators. EEGs on 10 healthy volunteers were recorded on the Cadwell Spectrum AT 386, using the Electrocap (10-20 system). The EEGs were analysed independently, with each operator selecting the first 48 artifact-free epochs. The results were analysed using the non-parametric Friedman two-way analysis of variance (ANOVA) for the discrimination analysis and a one-way ANOVA for the monopolar and bipolar Absolute Power raw measures. Statistical analysis of the discriminant data showed no significant differences between operators, with 7 of 10 studies yielding the same results. The remaining 3 studies were classified either as borderline or normal when analysed by different operators. Although a series of "t" tests comparing 2 operators showed most variability occurring in Absolute Power as compared with Relative Power, Power Asymmetry and Coherence, ANOVA of the raw mono- and bipolar Absolute Power measures showed no significant differences between the operators at the P = 0.05 level. Thus the differences between the operators were non-significant when comparing quantitative EEG analyses with respect to both the raw measures and the discriminant analyses.

Analysis of Variance

Human adipocyte lipid-binding protein: purification of the protein and cloning of its complementary DNA.

Human adipocyte lipid-binding protein (H-ALBP) was purified from normal subcutaneous adipose tissue to greater than 98% homogeneity, utilizing a combination of acid fractionation, gel filtration, covalent chromatography on activated thiol-Sepharose 4B, and anion-exchange chromatography. Human ALBP comprised about 1% of total cytosolic protein in human adipose tissue, had a relative molecular mass of about 15 kDa, and existed as a monomer in solution. The amino terminus of H-ALBP was blocked to sequencing. When a liposome ligand delivery assay was used, H-ALBP saturably bound oleic acid with about 1 mol of ligand bound per mole of protein. Additionally, H-ALBP saturably bound retinoic acid as determined by the quenching of intrinsic tryptophan fluorescence. A full-length H-ALBP cDNA has been cloned; the sequence predicts a 649-base mRNA comprised of a 62-base 5'-noncoding region containing an 18S ribosome-binding site, a single 396-base open-reading frame, and a 191-base 3'-noncoding region. Comparative sequence analysis indicated that the 132 amino acid H-ALBP is a member of a multigene family of intracellular lipid-binding proteins and contains the consensus substrate phosphorylation sequence for tyrosyl kinases.

Adipose Tissue

Extra-adrenal phaeochromocytoma: report of three interesting cases.

The clinical, laboratory and operative findings from three cases of extra-adrenal phaeochromocytoma are reviewed. Some of the difficulties encountered in localizing such a neoplasm are highlighted. Data from intraoperative catecholamine monitoring on the three patients are also presented. Adequate alpha and beta blockade produced stable cardiovascular parameters during surgery in all three individuals.

Abdominal Neoplasms