Distortions of ultrasonic field introduced by the rib cage in echocardiography.

In ultrasonic examination of the heart, the anatomy and motion of heart structures can be observed by placing the ultrasonic transducer over an intercostal window adjacent to the sternum. The ultrasonic beam may be reflected, refracted, or scattered from its path by the ribs and soft tissues before reaching the target of interest. This interaction between the tissues and ultrasound beam, which introduces significant changes in ultrasonic beam characteristics, may result in considerable degradation of the lateral resolution of the ultrasonic system, determined largely by the beam width. In this paper, the effect of rib cage on the beam characteristics is examined. It is shown that the rib cage can produce severe distortions of the ultrasonic beam, namely, asymmetry in beam cross-section, alteration in beam diameter, and deflection of the beam from its central path. It is also demonstrated that this distortion is dependent upon transducer diameter, width of the intercostal window, and transducer angulation relative to the breast plate.

Echocardiography↗

Ultrasonic characterization of blood during coagulation.

Recently ultrasound has been found to be extremely useful in detecting intracardiac thrombi as well as intracranial hemorrhages in neonates. The principal criterion used for clinical diagnosis of thrombus has been an increase in the echogenicity of clotted blood. However, echogenicity is a rather nonspecific and qualitative description of tissue ultrasonic properties. A rise in echogenicity could be the result of an increase in ultrasonic backscatter, or a decrease in attenuation, or a combination of both. In order to ascertain the mechanism responsible for the clinically observed increase in echogenicity and thus put the technique on a firm foundation, we have measured serially the ultrasonic velocity, attenuation and backscatter in human blood up to 24 hours following the onset of coagulation. Preliminary results show that all three ultrasonic properties increase during this time period. At 24 hours following clotting, the mean rises in velocity, attenuation and backscatter are 3.36 +/- 0.35 X 10(3) cm/sec, 2.3 +/- 0.22 db/cm and 18.5 +/- 1.2 dB per unit volume of blood (at 7.5 MHz and a temperature of 23 degrees C), respectively. These results indicate that the increase in echogenicity of a thrombus is due to a substantial increase in ultrasonic backscatter, which is moderated to a certain extent by the accompanied increase in attenuation.

Acoustics↗

Study of red cell aggregation in pulsatile flow from ultrasonic Doppler power measurements.

Human red cell aggregability and disaggregability represent important hemorheological parameters of blood. Several techniques have been proposed to evaluate the tendency of red cells to form aggregates and to disrupt in the presence of shear stress. One of the most recent approaches is based on the characterization of the intensity of ultrasonic scattered signals. A pulsatile flow loop model is used in the present study to demonstrate the potential applicability of Doppler ultrasound to detect and characterize the hemodynamic behavior of red cell aggregates. Porcine whole blood specimens collected from 20 different pigs were circulated in the flow model (tube diameter of 0.476 cm) at different mean velocities and pulsation rates. At a pulsation of 70 beats/min for mean velocities of 13 cm/sec and 63 cm/sec, no cyclic variation of the Doppler power was observed, suggesting the absence of rouleaux build-up and rouleaux disruption. At a pulsation of 20 beats/min and mean velocities of 11 cm/sec and 38 cm/sec, statistically significant cyclic variations (p < 0.01) were measured. It is suggested that aggregate size enlargement, rouleaux orientation with the flow field and the effect of shear stress on rouleaux disruption are possible causes for the observed cyclic variation of the Doppler power within the flow cycle at a pulsation of 20 beats/min. A discussion of the potential application of this technique for in vivo study in large vessels is given.

Animals↗