Localization of realistic cortical activity in MEG using current multipoles.

We present a novel approach to MEG source estimation based on a regularized first-order multipole solution. The Gaussian regularizing prior is obtained by calculation of the sample mean and covariance matrix for the equivalent moments of realistic simulated cortical activity. We compare the regularized multipole localization framework to the classical dipole and general multipole source estimation methods by evaluating the ability of all three solutions to localize the centroids of physiologically plausible patches of activity simulated on the surface of a human cerebral cortex. The results, obtained with a realistic sensor configuration, a spherical head model, and given in terms of field and localization error, depict the performance of the dipolar and multipolar models as a function of variable source surface area (50-500 mm(2)), noise conditions (20, 10, and 5 dB SNR), source orientation (0-90 degrees ), and source depth (3-11 cm). We show that as the sources increase in size, they become less accurately modeled as current dipoles. The regularized multipole systematically outperforms the single dipole model, increasingly so as the spatial extent of the sources increases. In addition, our simulations demonstrate that as the orientation of the sources becomes more radial, dipole localization accuracy decreases substantially, while the performance of the regularized multipole model is far less sensitive to orientation and even succeeds in localizing quasi-radial source configurations. Furthermore, our results show that the multipole model is able to localize superficial sources with higher accuracy than the current dipole. These results indicate that the regularized multipole solution may be an attractive alternative to current-dipole-based source estimation methods in MEG.

Algorithms↗

On MEG forward modelling using multipolar expansions.

Magnetoencephalography (MEG) is a non-invasive functional imaging modality based on the measurement of the external magnetic field produced by neural current sources within the brain. The reconstruction of the underlying sources is a severely ill-posed inverse problem typically tackled using either low-dimensional parametric source models, such as an equivalent current dipole (ECD), or high-dimensional minimum-norm imaging techniques. The inability of the ECD to properly represent non-focal sources and the over-smoothed solutions obtained by minimum-norm methods underline the need for an alternative approach. Multipole expansion methods have the advantages of the parametric approach while at the same time adequately describing sources with significant spatial extent and arbitrary activation patterns. In this paper we first present a comparative review of spherical harmonic and Cartesian multipole expansion methods that can be used in MEG. The equations are given for the general case of arbitrary conductors and realistic sensor configurations and also for the special cases of spherically symmetric conductors and radially oriented sensors. We then report the results of computer simulations used to investigate the ability of a first-order multipole model (dipole and quadrupole) to represent spatially extended sources, which are simulated by 2D and 3D clusters of elemental dipoles. The overall field of a cluster is analysed using singular value decomposition and compared to the unit fields of a multipole, centred in the middle of the cluster, using subspace correlation metrics. Our results demonstrate the superior utility of the multipolar source model over ECD models in providing source representations of extended regions of activity.

Biophysical Phenomena↗

Sensitivity matrix and reconstruction algorithm for EIT assuming axial uniformity.

In electrical impedance tomography (EIT) two-dimensional models continue to be applied despite their known inability to provide correct reconstruction. In this paper, a reconstruction algorithm that assumes a translationally invariant conductivity distribution is described. A more precise forward solver is obtained by taking off-slice currents into consideration. An appropriate sensitivity matrix is derived. Numerical evidence for the improvement in precision compared to two-dimensional reconstruction is given.

Algorithms↗