Search PubMed⌕ Search

Biomedical subjects

K J Wolf

Publications and source records attributed to K J Wolf.

At least 37 records · Page 2Linked to original sources

[Superparamagnetic iron oxide enhanced MR angiography of the portal vein system].

PURPOSE: Superparamagnetic iron oxide (SPIO) is used for the detection of focal liver lesions. The current study examines whether the blood-pool effect of an approved substance is adequate for contrast-enhanced MR angiography of the portal venous system. METHODS AND MATERIALS: Fifteen patients [9 women, 6 men, mean age 57 (34-73)] were examined with a breathhold 3D-FISP sequence (TR/TE/FA; 5 ms/2 ms/25 degrees) at 1.5 Tesla (Vision; Siemens, Erlangen) during the last third of a half-hour Infusion of a standard dose (15 mumol Fe/kg) of AMI-25 (Endorem, Guerbet Co., France). The image quality of source images and 3D reconstructions was evaluated by two examiners using a 3-point scale. RESULTS: Large vessels (portal vein, left and right branch of the portal vein, superior mesenteric vein, splenic vein) are visualized well or adequately in 80-93% of the cases, while this was achieved in only 53-60% of the small veins (vessels of the first order emptying into the superior mesenteric vein and the spleen). Venous arcades of the mesenterium are not visible by this technique. CONCLUSION: SPIO-supported MRA of the portal venous system yields usable results in the majority of patients. A possible indication is preinterventional angiography together with an SPIO examination for the detection of focal liver lesions.

Adult↗

MR imaging-guided biliary drainage in an open low-field system: first clinical experiences.

PURPOSE: To test the feasibility of MR imaging (MRI)-guided percutaneous biliary drainages in patients using an open MR-system. METHODS: 6 patients with mechanical cholestasis underwent MRI-guided puncture and catheterization of the biliary system following intervention planning with magnetic resonance cholangiography (MRC) in an open low-field MR system. Data on the number of punctures required, success in establishing external and internal drainage, and total procedure time were compared to those of 6 patients who underwent biliary drainage with fluoroscopic guidance. RESULTS: MRC facilitated intervention planning in all patients. Near-real-time MR imaging enabled interactive positioning of the devices. The bile ducts were punctured under MRI control in three patients in the first, in two in the second, and in one in the third attempt. MRI-guided puncture was faster than the fluoroscopic procedure. Catheterization for external drainage was successful in all patients. Passing the obstructions was not possible under MRI guidance. The procedure time for MRI-guided catheterization was longer than in the conventional technique. CONCLUSION: MRI-guidance allows reliable placement of an external biliary drainage in an open low-field MR system.

Aged↗

[Laser-induced thermotherapy (LITT) for liver metastasis in an open 0.2T MRI].

OBJECTIVE: To test the feasibility and safety of the laser-induced thermotherapy (LITT) for liver metastases in open MR imaging system operating at 0.2 Tesla. METHOD: Laser therapy using the Nd:YAG laser was performed on 25 patients with a total of 41 liver metastases. An open low-field MRI scanner was used for puncture, positioning of the laser applicator, and monitoring the therapy. A true FISP sequence was used to track the puncture in close to real-time. Localization diagnostics and temperature monitoring were aided by T1-weighted gradient echo sequences in the breath-holding technique. In the first follow up after 24-48 hours, a contrast-enhanced T1-weighted gradient-echo sequence was performed in an MRI scanner at 1.5T. The pre-, intra- and postinterventional volumes of the liver metastases as well as the thermolesions and the thermonecroses were determined. RESULTS: LITT in an open MRI system was technically feasible in all patients with no clinically relevant complications. The mean volumes of the thermolesions measured during intervention in low-field MRI were lower than the volumes of the thermonecroses measured after intervention in high-field MRI. CONCLUSION: The technique presented here of laser-induced thermotherapy for liver metastases in an open MRI system is technically feasible and safe.

Aged↗

Superparamagnetic iron oxide-enhanced MRI of atherosclerotic plaques in Watanabe hereditable hyperlipidemic rabbits.

RATIONALE AND OBJECTIVES: Inflammatory atherosclerotic plaques are characterized by increased endothelial permeability and multiple macrophages. Blood-pool MRI contrast agents like superparamagnetic iron oxide (SPIO) have an affinity for the monocyte-macrophage system and thus, may label inflammatory plaques. The objective was to demonstrate SPIO uptake in plaques of atherosclerotic rabbits by MRI and histology. METHODS: Aortas of anesthetized Watanabe hereditable hyperlipidemic rabbits were studied with a moderately T2*-weighted gradient-echo sequence at 1.5 T. Four groups of five animals each were studied: (1) without ultrasmall SPIO (carboxydextran coating; particle size, 25 nm; estimated plasma half-life, 6 hours) or with imaging after intravenous injection of SPIO at a dose (micromol Fe/kg) and postcontrast time delay (hours) of 50/8 (2), 50/24 (3), or 200/48 (4). In vivo MRI was compared with corresponding ex vivo histological iron stains. RESULTS: Animals receiving 200 micromol Fe/kg demonstrated areas of focal signal loss clearly confined to the aortic wall on a mean of 24 +/- 9 (31% +/- 11%) of 76 +/- 5 images compared with 0 +/- 0 of 76 +/- 5 images in controls (P = 0.009). The number of images with this finding in groups 2 and 3 was not significantly different compared with controls. By microscopy, SPIO-iron was seen in the endothelial cells and subendothelial intimal macrophages of atherosclerosis-prone aortic wall segments. Atherosclerotic lesions demonstrating iron uptake also showed a high macrophage content. CONCLUSIONS: SPIO accumulates in aortic plaques of atherosclerotic rabbits, producing a characteristic MRI finding. As SPIO accumulates in plaques with increased endothelial permeability and a high macrophage content, two established features of plaque inflammation, it may have a potential for noninvasive assessment of inflammatory atherosclerotic plaques.

Animals↗

B-mode enhancement at phase-inversion US with air-based microbubble contrast agent: initial experience in humans.

Pulse- or phase-inversion ultrasonography (US) sums the signals returned from two 180 degrees ultrasound pulses. Linear scattering from tissue results in a signal void while nonlinear signals from microbubbles stand out. The technique was applied with a US contrast agent in 39 human subjects. B-mode enhancement of vessels and organ parenchyma was seen in all cases. Enhancement occurred from flowing and stationary microbubbles. The flow-independent enhancement of normal and abnormal tissue represents a major advance in contrast material-enhanced US with many potential applications especially in tumor imaging.

Adult↗

Prototype of a JAVA/DICOM image server with integrated findings and data security.

The transfer of medical data within heterogeneous hard- and software infrastructures requires platform-independent standardized protocols and data formats such as DICOM. To avoid costly vendor-specific solutions a DICOM server was implemented in JAVA thereby enabling the data access via internet browser technology. The most important patient and image acquisition information were extracted from the DICOM images and stored into a relational database. For an integrated view patient information such as radiological findings were transferred from the Radiological Information System (RIS) into the data base. Image data were accessed either by a fast preview tool or using a DICOM viewer. Since DICOM does not include inherent data security mechanisms, a second tool allowed the DICOM-conform encryption of DCIOM data for a secure long term storage on CD-R or across unsecure networks.

Computer Security↗

Magnetic resonance-guided vascular catheterization: feasibility using a passive tracking technique at 0.2 Telsa in a pig model.

The objective of this study was to demonstrate in an animal model the feasibility of a passive tracking technique for catheter visualization of magnetic resonance (MR)-guided endovascular procedures. All experiments were performed in a 0.2 Tesla open MR system. Susceptibility-based catheters and guide wires were introduced into the aorta and were advanced selectively into the splenic and renal arteries under MR guidance. Based on a previously acquired contrast-enhanced magnetic resonance angiography (MRA) data set, the catheter positioning was performed by using a single-slice true fast imaging with steady state precession (FISP) sequence with a frame rate of 1.3 seconds. Contrast-enhanced MRA was performed in all animals. All catheters were advanced without complications into the aorta and were introduced into the proximal parts of the right renal and splenic arteries under MR guidance. Catheter manipulations were more difficult in the distal parts of these vessels due to the more complex anatomy. Passive catheter tracking is a valuable and technically robust alternative to active tracking methods, because it does not require additional hardware and, thus, can be implemented and used easily with any open MR imaging system. J. Magn. Reson. Imaging 1999;10:841-844.

Animals↗

Arthritis of the finger joints: a comprehensive approach comparing conventional radiography, scintigraphy, ultrasound, and contrast-enhanced magnetic resonance imaging.

OBJECTIVE: A prospective study was performed comparing conventional radiography, 3-phase bone scintigraphy, ultrasound, and magnetic resonance imaging (MRI) with precontrast and dynamic postcontrast examinations in 60 patients with various forms of arthritis including rheumatoid arthritis (RA), spondyl-arthropathy, and arthritis associated with connective tissue disease. METHODS: A total of 840 finger joints were examined clinically and by all 4 imaging methods. Experienced investigators blinded to the clinical findings and diagnoses analyzed all methods independently of each other. The patients were divided into 2 groups. Group 1 included 32 patients (448 finger joints) without radiologic signs of destructive arthritis (Larsen grades 0-1) of the evaluated hand and wrist and group 2 included 28 patients (392 finger joints) with radiographs revealing erosions (Larsen grade 2) of the evaluated hand and/or wrist. RESULTS: Clinical evaluation, scintigraphy, MRI, and ultrasound were each more sensitive than conventional radiography in detecting inflammatory soft tissue lesions as well as destructive joint processes in arthritis patients in group 1. All differences were statistically significant. We found ultrasound to be even more sensitive than MRI in the detection of synovitis. MRI detected erosions in 92 finger joints (20%; 26 patients) in group 1 that had not been detected by conventional radiography. CONCLUSION: Our data indicate that MRI and ultrasound are valuable diagnostic methods in patients with arthritis who have normal findings on radiologic evaluation.

Adult↗

Results of a prospective multicenter study for evaluation of the diagnostic quality of an open whole-body low-field MRI unit. A comparison with high-field MRI measured by the applicable gold standard.

OBJECTIVE: To evaluate the diagnostic quality of an open whole-body low-field MRI scanner compared to high-field scanners. MATERIALS AND METHODS: Over a period of 3 months, 401 patients with diseases of the kidney (n = 78), the shoulder (n = 122), the spine (n = 105) and the cerebrum (n = 96) were prospectively evaluated in four participating centers. They all underwent clinical evaluation, low-field and high-field MRI examination and surgical or follow-up confirmation of diagnosis. Clinical, histopathologic, high-field and low-field MRI diagnoses were recorded in standardized questionnaires that were centrally evaluated. Statistical evaluation comprised two parts: ROC analysis assessed accuracy of MRI and clinical diagnoses; furthermore rates of concordance of high- and low-field MRI diagnosis were calculated. RESULTS: We found no statistically relevant difference in high-field MRI diagnosis compared to low-field MRI diagnostic accuracy measured by clinical or surgical gold standard in three of the four regions examined; in cerebral examinations there was a small yet significant advantage for the high-field systems (P = 0.01). CONCLUSION: We conclude that the open low-field scanner we evaluated using clinical and surgical gold standard as reference is able to achieve comparable diagnostic accuracy compared to high-field scanners at lower costs and greater patient comfort. Limitations due to field strength (signal-to-noise ratio, resolution, scan time) seem to be relevant only in a very small number of cases that warrant high-field examination.

Adult↗

A new concept for melatonin deficit: on pineal calcification and melatonin excretion.

Even though exogenous melatonin has proven to influence sleep and circadian parameters, low endogenous melatonin is not related to sleep disturbances, nor does it predict response to melatonin replacement therapy. In this manuscript, we present a new concept towards a definition of a melatonin deficit. The purpose of the study was to introduce a marker for an intra-individual decrease in melatonin production. Therefore, we developed a method to quantify the degree of pineal calcification (DOC) using cranial computed tomography. Combining pineal DOC with the organs's size, we estimated the uncalcified pineal gland volume. This estimation was positively and significantly associated with 6-sulfatoxymelatonin (aMT6s), collected over 24 hours in urine, in 26 subjects. Data yielded evidence that the decline in aMT6s excretion with age can be sufficiently explained by an increased pineal calcification. These results suggest that DOC might be useful as an indicator of an intra-individual, decreased capability of the pineal gland to produce melatonin. DOC might prove to be a response-marker for melatonin replacement therapy and a vulnerability marker of the circadian timing system.

Adolescent↗

[SPIO-enhanced MR angiography for the detection of venous thrombi in an animal model].

PURPOSE: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. METHODS: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 degrees). Imaging was performed before and up to 90 minutes after intravenous injection of 30 mumol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34 +/- 17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners. using histology as the gold standard. RESULTS: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being overestimated by MRI in 4 cases and underestimated in 21. In these 21 cases, the histologically observed recanalization could not be detected by MR angiography. CONCLUSIONS: SPIO-enhanced MR angiography achieves adequate vessel contrast and reliable thrombus detection in animal experiments. Partial volume effects prevent microscopically observed recanalization from being detected by clinical MRI.

Animals↗

[Keyhole-true FISP: fast T2-weighted imaging for interventional MRT at 0.2 T].

PURPOSE: The aim of this study is to introduce a fast, T2 weighted true FISP keyhole sequence implemented on an open C arm low field magnetic resonance (MR) scanner for interventional procedure guidance. METHOD: Following the acquisition of a reference data set using a true FISP (fast Imaging with Steady Precision) sequence, only the 32 central raw data lines (keyhole) are acquired in a fluoroscopic-like mode enabling continuous image reconstruction and update. The keyhole true-FISP sequence was tested in animal experiments and used in MR-guided interventions in 10 patients. RESULTS: The described true FISP keyhole sequence is characterized by an image frame rate of 2.5 images per second and a T2-like contrast. Due to system constraints with respect to the reconstruction, the actual displaying of images was delayed by up to 180 ms. CONCLUSIONS: The use of the described keyhole sequence enabled a fluoroscopy-like guidance of interventional devices in an open, low-field system.

Animals↗

Neurogenic hypertension. A new MRI protocol for the evaluation of neurovascular compression of the cranial nerves IX and X root-entry zone.

OBJECTIVE: Neurovascular compression of the rostral ventrolateral medulla (RVLM) has been implicated in the pathogenesis of essential hypertension. Although MRI has been widely used to evaluate the morphologic relation of structures in this region, spatial resolution of the previously used techniques was limited. This article describes the use of a new MRI protocol that combines two sequences with improved spatial resolution and complementary image information as well as a set of defined criteria for image analysis. METHODS: MRI of the brain stem was performed in 60 hypertensive and 50 normotensive subjects using a 3D-CISS and a 3D-FISP-MRA sequence. Neurovascular contact in the RVLM was independently assessed by four readers using predefined criteria and compared with a consensus finding. Agreement was expressed by kappa statistics on a 0 to 1 scale. RESULTS: Left-sided neurovascular contact within the RVLM was found in 13 (22%) hypertensive and 6 (12%) control subjects. The inter-reader agreement for positive and negative findings ranged from 0.47 to 0.79; agreement to the consensus finding ranged from 0.65 to 0.90. CONCLUSIONS: The combination of 3D-CISS and arterial flow-sensitive 3D-FISP, together with the evaluation criteria defined in this study, can be used for describing the finer anatomic features of the brain stem, and in particular for investigation of neurovascular contact of the IX/X cranial nerve root-entry zone. The high quality of images and the substantial or almost perfect reader-consensus agreement should make this protocol useful for future investigations of the neurovascular compression syndrome in patients with essential hypertension and possibly in other neurovascular compression syndromes, such as trigeminal neuralgia and hemifacial spasm.

Adult↗

MR angiography with superparamagnetic iron oxide: feasibility study.

Magnetic resonance (MR) angiography with blood-pool superparamagnetic iron oxide (SPIO) particles was evaluated in the whole-body vascular system. In 12 adult patients, three-dimensional fast imaging with steady-state precession was performed in successive steps from the lungs to the calves before and after a standard dose for liver imaging (15 mumol of iron per kilogram of body weight) of AMI-25. On SPIO-enhanced MR angiograms, visualization of the pulmonary arterial, whole-body, and lower extremity venous systems was graded as good or sufficient in all patients, and femoral vein thrombosis was clearly demonstrated in one patient.

Adult↗

[Percutaneous removal of a brachiocephalic vein anchored venous catheter with wire loop and mini-laparoscopy scissors].

PURPOSE: The use of mini-laparoscopy scissors to remove a central venous catheter inadvertently fixed to the wall of the brachiocephalic vein is described. PATIENT AND METHODS: During a rethoracotomy in a 15-year-old female patient, a central venous catheter preoperatively introduced in the left subclavian vein was inadvertently trapped by a suture and fixed to the wall of the left brachiocephalic vein. The foreign body was removed by use of a transjugularly introduced venous sheath, a catheter wire snare, and mini-laparoscopy scissors. RESULTS: The fixed catheter was freed from the wall of the vein under fluoroscopic control with the help of a mini-laparoscopy scissors. Since the intravasal end of the catheter had already been grasped during mobilization with the wire snare it could be completely removed subsequently without any problem. CONCLUSIONS: The percutaneous, intravascular use of mini-laparoscopy instruments may be considered for foreign body removal in special cases.

Adolescent↗

fMRI assessment of somatotopy in human Brodmann area 3b by electrical finger stimulation.

Functional magnetic resonance imaging (fMRI) is capable of detecting focal brain activation induced by electrical stimulation of single fingers in human subjects. In eight subjects somatotopic arrangement of the second and fifth finger was found in Brodmann area 3b of the primary somatosensory cortex. In four subjects the representation area of the second finger was located lateral and inferior to the fifth finger; in one subject the somatotopy was reversed. In three subjects representation areas of the two fingers in Brodmann area 3b were found overlapping. Additional activated areas were found on the crown of ipsilateral and contralateral postcentral gyrus (Brodmann areas 1 and 2) and posterior parietal cortex.

Adult↗