The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.

LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.

Copper↗

Type testing the Model 6600 plus automatic TLD reader.

The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.

Equipment Design↗

The dose-response of Harshaw TLD-700H.

Harshaw TLD-700H (7LiF:Mg,Cu,P) was previously characterised for low- to high-dose ranges from 1 microGy to 20 Gy. This paper describes the studies and results of dose-response and linearity at much higher doses. TLD-700H is a near perfect dosimetric material with near tissue equivalence, flat energy response, and the ability to measure beta, gamma and X rays. These new results extend the applicability of Harshaw TLD-700H into more dosimetric measurement environments. The simple glow curve structure provides insignificant fade, eliminating special oven preparation methods experienced by other materials. The work presented in this paper quantifies the performance of Harshaw TLD-700H in extended ranges.

Computer Simulation↗

LiF:Mg,Cu,P glow curve shape dependence on heating rate.

The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curves are deconvoluted using the new Harshaw Glow Curve Analyser (GCA) program. Results of the study are presented, as well as possible explanations as to the observed effects.

Computer Simulation↗

Evaluating two extremity dosemeters based on LiF:Mg,Ti or LiF:Mg,Cu,P.

Evaluation of a new extremity dosemeter is presented. The dosemeter is a passive device that is easy to wear and features a permanent individual numerical ID with barcode, a watertight case, an automatic TLD reader and database management software. Two dosemeters were studied: the first consists of a 100 mg x cm(-2) 7LiF:Mg,Ti (TLD-700) chip and a 42 mg x cm(-2) cap, the other consists of a 7 mg x cm(-2) layer of 7LiF:Mg,Cu,P (TLD-700H) powder and a 5 mg x cm(-2) cap. Sensitivity, repeatability, lower limit detection, angular responses and energy responses for these dosemeters are studied and presented. The dose calculation algorithm is developed and its dosimetric performance accuracy is compared with the standard ANSI N13.32-1995, Performance Testing of Extremity Dosemeters.

Beta Particles↗

A new paradigm in personal dosimetry using LiF:Mg,Cu,P.

The United States Navy has been monitoring personnel for occupational exposure to ionising radiation since 1947. Film was exclusively used until 1973 when thermoluminescence dosemeters were introduced and used to the present time. In 1994, a joint research project between the Naval Dosimetry Center, Georgetown University, and Saint Gobain Crystals and Detectors (formerly Bicron RMP formerly Harshaw TLD) began to develop a state of the art thermoluminescent dosimetry system. The study was conducted from a large-scale dosimetry processor point of view with emphasis on a systems approach. Significant improvements were achieved by replacing the LiF:Mg,Ti with LiF:Mg,Cu,P TL elements due to the significant sensitivity increase, linearity, and negligible hiding. Dosemeter filters were optimised for gamma and X ray energy discrimination using Monte Carlo modelling (MCNP) resulting in significant improvement in accuracy and precision. Further improvements were achieved through the use of neural-network based dose calculation algorithms. Both back propagation and functional link methods were implemented and the data compared with essentially the same results. Several operational aspects of the system are discussed, including (1) background subtraction using control dosemeters, (2) selection criteria for control dosemeters, (3) optimisation of the TLD readers, (4) calibration methodology, and (5) the optimisation of the heating profile.

Algorithms↗