Search PubMed⌕ Search

Biomedical subjects

K J Beatt

Publications and source records attributed to K J Beatt.

49 records · Page 3Linked to original sources

[Implantation of endoprostheses in aortocoronary bypass. Preliminary experience at the Thoraxcenter of Rotterdam].

An intraluminal stent was implanted in 5 patients after dilatation of an aorto-coronary venous graft. In the first 4 patients the procedure was motivated by restenosis after angioplasty. In the 5th patient the stent was implanted as a first-line measure in a case of dilated venous bypass stenosis. Stent implantation carries a risk of thrombosis and requires effective anticoagulation. Thus, one of our patients had to be reoperated upon for prosthetic thrombosis facilitated by the withdrawal of anticoagulants owing to a gastrointestinal haemorrhage. After a 3-month follow-up, the results seem to be encouraging in spite of a case of restenosis located at the proximal end of the tutor. However, more time will be needed to determine precisely the effectiveness of stents in the prevention of restenosis after venous graft dilatation.

Aged↗

[Effects and chronology of coronary restenosis after percutaneous transluminal coronary angioplasty. Quantitative angiographic analysis at 1, 2, 3, 4 and 5 months].

Coronary restenosis occurs fairly early after transluminal coronary angioplasty, as suggested by anatomico-clinical, isotopic and angiographic studies. Its incidence, as reported in the literature, varies according to the clinical selection of patients, to the number of patients with follow-up angiography and the timing of this procedure, and to the criteria used to define restenosis. In this prospective study we endeavoured to determine the exact date at which restenosis takes place, as well as its true incidence, by means of 6 different angiographic criteria. The population studied was divided into five groups and each group underwent coronary arteriography at a different date: during the 1st, 2nd, 3rd, 4th and 5th post-angioplasty months respectively. In 424 of the 500 patients thus examined (84.8 p. 100), coronary angiography involved automatic detection of contours and made quantitative analysis possible. Coronary restenosis was found to occur early, with a peak of incidence in the 3rd month. Its incidence varied considerably depending on the criterion used. A critical analysis of the data has prompted us to use a criterion based on absolute values determined by quantitative angiographic analysis.

Adolescent↗

Coronary blood flow velocity during percutaneous transluminal coronary angioplasty as a guide for assessment of the functional result.

To investigate the clinical usefulness of intracoronary Doppler recordings during percutaneous transluminal coronary angioplasty (PTCA), the changes of intracoronary blood flow velocity during PTCA were assessed in 20 patients with single proximal coronary stenosis, using a Doppler probe end-mounted on the tip of a PTCA catheter. A mean of 4 inflations was performed in each patient. Intracoronary velocities were measured before and after each inflation and during peak reactive hyperemia after each transluminal occlusion. Quantitative analysis of the coronary stenosis was assessed before and after PTCA, and the dilatation resulted in an increase in minimal luminal cross-sectional area from 1.1 +/- 0.8 to 2.7 +/- 1.2 mm2. A gradual and significant improvement in velocities was observed after the first 3 dilatations, but in 15 of the 20 patients the resting and hyperemic velocities were not affected by the fourth dilatation. Coronary flow reserve measured during reactive hyperemia after the last dilatation with the PTCA catheter across the lesion was 1.9. This value of coronary flow reserve is compatible with the residual stenosis measured after PTCA when corrected for the presence of the Doppler balloon catheter (0.68 mm2). This application of the Doppler technique may provide a new method of on-line functional monitoring of the PTCA procedure in individual patients, but does not yet allow an accurate prediction of the change in coronary geometry brought about by PTCA.

Adult↗

Angioplasty for stable versus unstable angina pectoris: are unstable patients more likely to get restenosis? A quantitative angiographic study in 339 consecutive patients.

Current evidence with regard to the possible association between clinical expression of coronary disease prior to the time of angioplasty, and the subsequent risk of restenosis following successful dilatation, remains inconclusive. To prospectively compare the incidence of restenosis in stable versus unstable angina pectoris patients, follow-up angiography was performed in 85 percent of patients from a consecutive series with a successful PTCA, irrespective of presence or absence of recurrent ischemic symptoms. Furthermore, changes in lesion severity were assessed quantitatively by an automated edge-detection technique rather than visual analysis. Employing such a study design and follow-up protocol, it was found that the incidence of restenosis in patients with stable coronary artery disease was similar to that of patients with unstable rest angina, irrespective of the type of angiographic definition used.

Angina Pectoris↗

Change in diameter of coronary artery segments adjacent to stenosis after percutaneous transluminal coronary angioplasty: failure of percent diameter stenosis measurement to reflect morphologic changes induced by balloon dilation.

To determine the changes in stenotic and nonstenotic segments of a dilated coronary artery, detailed quantitative angiographic measurements were performed in 342 patients (398 lesions) immediately after angioplasty and at a predetermined follow-up time of 30, 60, 90 or 120 days after the dilation. Measurements of the stenotic segments were expressed as minimal luminal diameter, and the adjacent nonstenotic segments were expressed as interpolated reference diameter (both in millimeters). A follow-up rate of 86% was achieved. In the patients followed up at 30 and 60 days, there was no significant change in either the mean minimal luminal diameter or the mean reference diameter. However, at 90 and 120 days, there was significant deterioration in both the mean minimal luminal diameter (-0.37 and -0.42 mm, respectively) and the mean reference diameter (-0.17 and -0.26 mm, respectively), all of the changes being highly significant (p less than 0.00001). The reference diameter is involved in the dilation process and may be subject to the same restenosis process that takes place in initially stenotic segments. Percent diameter stenosis measurements, which are conventionally used to express the change in the severity of a stenosis after angioplasty, will tend to underestimate the change when there is a simultaneous reduction in the reference diameter.

Aged↗

Percutaneous balloon valvuloplasty for calcific aortic stenosis. A treatment 'sine cure'?

Twenty-five elderly patients with calcific aortic stenosis, 12 male (48%) and 13 female (52%), mean age 74.8 +/- 7.6 years, underwent percutaneous aortic balloon valvuloplasty between March 1986 and September 1987. Twenty-two patients (88%) were in class III-IV of the New York Heart Association, 13 (52%) had a history of previous angina and 7 (28%) of syncopal attacks. All patients had been considered either unsuitable or high-risk candidates for aortic-valve replacement because of age or associated diseases. Balloons of increasing size (area ranging from 1.3 to 3.8 cm2 during inflation) were successively passed retrogradely from the femoral artery and manually inflated to 3-7 atmospheres. Inflation duration ranged from 15 to 260 s (mean 40 s). Post-dilatation there were significant changes in left ventricular peak-systolic and end-diastolic pressures (P less than 0.00001 and P less than 0.01, respectively), mean systolic aortic transvalvular gradient (from 73 to 43 mmHg, P less than 0.000001), mean systolic aortic flow (from 176 to 208 ml s-1, P less than 0.0001) and aortic valve area (from 0.47 to 0.72 cm2, P less than 0.000001). Major complications included: in-hospital deaths of two patients (8%) admitted in cardiogenic shock; left haemiplegia (4%); transient haemianopia (8%); development of grade III aortic insufficiency (4%); and persistent complete atrioventricular block (4%). Complications at the puncture-site occurred in 7 patients (28%)--including two femoral pseudoaneurysms and the need for surgical removal of a balloon remnant after rupture in one patient. No local haemorrhagic complications were observed in the latter eight procedures, performed using a 16.5 French 100-cm long arterial introducer. At a mean follow-up of 13.0 +/- 5.0 months, an important functional improvement persisted in 14 patients (56%), no major changes in pre-valvuloplasty symptoms were observed in 3 patients (12%), while five patients (20%) required surgical treatment after a successful valvuloplasty because of recurrence of symptoms (late valve restenosis). Percutaneous aortic balloon valvuloplasty is a possible palliative therapy in elderly patients with calcific aortic stenosis. However, its inherent immediate risk, limited haemodynamic result and the possible development of valve restenosis at medium-term follow-up, suggest that the application of this technique should be limited to poor surgical candidates.

Aged↗

Haemodynamic observations during percutaneous transluminal coronary angioplasty in the presence of synchronised diastolic coronary sinus retroperfusion.

Animal studies have demonstrated that synchronised coronary sinus retroperfusion with arterial blood can provide effective perfusion of ischaemic myocardium. Preliminary clinical studies have shown that the technique can also be used with safety in human beings, and in the present study its effectiveness was assessed in three patients undergoing repeated coronary artery occlusions during percutaneous transluminal coronary angioplasty. Arterial blood was removed via an 8F catheter positioned in the femoral artery and delivered by a retroperfusion pumping system to a 7F retroperfusion balloon catheter positioned in the anterior cardiac vein. Ischaemia-related indices were monitored both before and during coronary sinus retroperfusion. These indices included high fidelity left ventricular pressure recordings and pressure derived indices (including velocities of isovolumic contraction and relaxation), as well as electrocardiographic changes and symptoms. Analysis of these variables showed that the ischaemic changes induced during coronary artery occlusion were not prevented by this type of coronary sinus retroperfusion. There was no major complication in any of the patients. It may be that adaptation of the technique or the use of alternative end points will establish a benefit, but further modifications of the delivery system are necessary for effective clinical use.

Aged↗

Incidence of restenosis after successful coronary angioplasty: a time-related phenomenon. A quantitative angiographic study in 342 consecutive patients at 1, 2, 3, and 4 months.

Data from experimental, clinical, and pathologic studies have suggested that the process of restenosis begins very early after coronary angioplasty. The present study was performed to determine prospectively the incidence of restenosis with use of the four National Heart, Lung, and Blood Institute and the 50% or greater diameter stenosis criteria, as well as a criterion based on a decrease of 0.72 mm or more in minimal luminal diameter. Patients were recatheterized at 30, 60, 90, or 120 days after successful percutaneous transluminal coronary angioplasty (PTCA). After PTCA all patients received 10 mg nifedipine three to six times a day and aspirin once a day until repeat angiography. Of 400 consecutive patients in whom PTCA was successful (less than 50% diameter stenosis), 342 underwent quantitative angiographic follow-up (86%) by use of an automated edge-detection technique. A wide variation in the incidence of restenosis was found dependent on the criterion applied. The incidence of restenosis proved to be progressive to at least the third month for all except NHLBI criterion II. At 4 months a further increase in the incidence of restenosis was observed when defined as a decrease of 0.72 mm or more in minimal luminal diameter, whereas the criteria based on percentage diameter stenosis showed a variable response. The lack of overlap between the different restenosis criteria applied affirms the arbitrary nature of angiographic definitions currently in use. Restenosis should be assessed by repeat angiography, and preferably ascertained according to the change in absolute quantitative measurements of the luminal diameter.

Adult↗

Percutaneous aortic balloon dilatation for calcific aortic stenosis in elderly patients: immediate haemodynamic results and short-term follow up.

Eight elderly patients (mean (SD) age 72.6 (8.5) years) with severe calcified stenosis of the aortic valve were considered for transluminal balloon dilatation in the Thoraxcenter between March and November 1986. In one patient the procedure could not be performed because of technical difficulties. Balloons of increasing diameter (13-25 mm) were successively passed retrogradely from the femoral artery and manually inflated with pressures of 400-600 kPa (4-6 atmospheres). Post-dilatation, there were significant changes in left ventricular pressures (from 237/21 to 204/13 mm Hg), mean systolic gradient (from 66 to 41 mm Hg, systolic aortic flow (from 172 to 202 ml/s, and aortic valve area (from 0.47 to 0.74 cm2); the cardiac index did not increase significantly (from 2.4 to 2.5 l/min/m2). One patient developed a pseudoaneurysm at the site of the femoral artery puncture that required surgical repair two months after the procedure; one patient experienced an acute left hemianopia during the procedure but had almost completely recovered at discharge. Five patients maintained a clinical improvement at a mean follow up time of 4.5 months after the procedure; two patients underwent aortic valve replacement, one because of minimal haemodynamic improvement after aortic balloon dilatation and persistence of severe dyspnoea and the other because of late recurrence of symptoms caused by restenosis after a successful procedure. Aortic balloon dilatation provides an alternative treatment for patients who are poor surgical candidates for cardiac or extracardiac reasons. At this stage the limited haemodynamic improvements suggest that the treatment can only be regarded as palliative, although proposed technical advances may achieve better immediate results in the future. Long term follow up is needed to evaluate the usefulness of this technique.

Aged↗

Acute myocardial infarction: strategies for thrombolytic therapy.

Thrombolytic therapy has revolutionised the treatment of acute myocardial infarction. This has led to a need for rapid and accurate diagnosis of this condition, provision of a triage protocol to achieve initiation of thrombolytic therapy as soon as the diagnosis has been made, and knowledge of the benefit:risk ratio of thrombolytic therapy in different subgroups of patients to allow the most effective use of these agents without compromising patient safety.

Electrocardiography↗