Search PubMed⌕ Search

Biomedical subjects

K Ido

Publications and source records attributed to K Ido.

At least 37 records · Page 2Linked to original sources

Radiographic evaluation of posterolateral lumbar fusion for degenerative spondylolisthesis: long-term follow-up of more than 10 years vs. midterm follow-up of 2-5 years.

Although posterolateral fusion of the lumbar spine without instrumentation has been widely performed for spinal instability caused by degenerative spondylolisthesis in the lumbar spine, few long-term follow-up studies have been reported. We studied ten patients who underwent posterolateral fusion for degenerative spondylolisthesis in the lumbar spine without instrumentation in our hospital, five of whom were followed up for more than 10 years and the other five for 2-5 years. We used radiography to examine their fusion status, instability and degenerative changes at the fusion level, change in the slip, change in lumbar lordosis, and instability and degenerative changes one level above and one level below the fusion. In most of the ten patients, radiographic evaluation demonstrated solid fusion, minimal degenerative changes, and preservation of lumbar lordosis and spinal mobility. Posterolateral lumbar fusion for degenerative spondylolisthesis in the lumbar spine seems promising for obtaining not only good radiographic features but also good clinical results lasting over more than 10 years.

Aged↗

Transpapillary intraductal US prior to biliary drainage in the assessment of longitudinal spread of extrahepatic bile duct carcinoma.

BACKGROUND: The utility of intraductal US via the transpapillary route prior to biliary drainage in the assessment of longitudinal extension of extrahepatic bile duct carcinoma was investigated. METHODS: In 19 patients with extrahepatic bile duct carcinoma who underwent surgical resection, an ultrasonic probe (diameter, 2.0 mm; frequency, 20 MHz) was inserted into the bile duct via the transpapillary route prior to biliary drainage. Longitudinal cancer extension along the bile duct was prospectively determined and compared with the histologic findings in the resected specimens. RESULTS: Results on the hepatic side were as follows: Intraductal US demonstrated more extensive longitudinal cancer spread than cholangiography in 9 of 19 patients with one instance of overdiagnosis. The accuracy of intraductal US in assessing the extent of spread (84%) was superior to that of cholangiography (47%) (p < 0.05). Results on the duodenal side were as follows: In patients with suprapancreatic bile duct cancer (n = 14), intraductal US demonstrated more extensive longitudinal cancer spread than cholangiography in 8 of 14 patients. The accuracy of intraductal US in assessing the extent of the spread (86%) was superior to that of cholangiography (43%) (p < 0.05). CONCLUSIONS: Transpapillary intraductal US prior to biliary drainage is useful in demonstrating longitudinal extension of bile duct cancer. However, the surgical margins were inaccurate in some patients.

Aged↗

Fibrous adhesive entrapment of lumbosacral nerve roots as a cause of sciatica.

STUDY DESIGN: Report of seven patients with fibrous adhesive entrapment of lumbosacral nerve roots as a cause of sciatica, whose radiographic findings were negative and who experienced relief from sciatica immediately after the entrapment was released. OBJECTIVES: To describe a new clinical entity of fibrous adhesive entrapment of lumbosacral nerve roots with negative radiographic findings. SETTING: Orthopaedic department, Japan. METHODS: Clinical evaluation and post-operative outcome in seven patients with entrapment of lumbosacral nerve roots because of fibrous adhesion confirmed intraoperatively. RESULTS: Radiographic examinations by magnetic resonance imaging (MRI), myelography, and computed tomographic (CT) myelography demonstrated neither disc herniations nor spinal stenosis in all seven patients, and differential nerve root block was effective for relieving sciatica and low back pain. We confirmed, intraoperatively, entrapment of the nerve root by fibrous adhesion, and all seven patients were relieved from sciatica and low back pain postoperatively. CONCLUSION: This study presented seven patients with sciatica caused by fibrous adhesive entrapment of lumbosacral nerve roots who underwent decompression and release of fibrous adhesion. Radiographic examinations, such as MRI, myelography and CT myelography, showed no compressive shadows and also differential nerve root block was effective for its diagnosis. This study seems to be the first report of patients with entrapment of lumbosacral nerve roots caused by fibrous adhesion, whose radiographic findings were negative.

Adult↗

Comparison of intraductal ultrasonography with percutaneous transhepatic cholangioscopy for the identification of residual bile duct stones during lithotripsy.

BACKGROUND: An imaging modality that can be used to identity small stones after a biliary lithotripsy is required. Intraductal ultrasonography was evaluated by using percutaneous transhepatic cholangioscopy as the gold standard. METHODS: Lithotripsy, under percutaneous transhepatic cholangioscopy guidance, was performed in 20 patients. A thin-caliber ultrasonic probe (2.0 mm in diameter and 20 MHz frequency) was inserted into the bile duct through the percutaneous tract after lithotripsy, and residual stones were identified. This was followed by percutaneous transhepatic cholangioscopy. RESULTS: In the extrahepatic bile ducts, intraductal ultrasonography provided images of all the stones demonstrated on cholangioscopy (n = 11). The sensitivity was superior to that of cholangiography (P < 0.005). However, in the intrahepatic bile ducts, intraductal ultrasonography only visualized the stones located in the cannulated lobe. Extrahepatic stones smaller than 5.0 mm in diameter or in a common hepatic duct larger than 15.0 mm in diameter were missed by cholangiography, but were visualized by the use of intraductal ultrasonography (P < 0.05). CONCLUSIONS: Intraductal ultrasonography is equivalent to cholangioscopy in the extrahepatic bile ducts. Cholangiography and intraductal ultrasonography should be used in combination to image intrahepatic and extrahepatic stones.

Aged↗

Epinephrine irrigation for the prevention of pancreatic damage after endoscopic balloon sphincteroplasty.

BACKGROUND AND AIM: Endoscopic balloon sphincteroplasty (EBS) is an alternative to sphincterotomy for the treatment of bile duct stones. The purpose of this study was to determine if epinephrine irrigation of the papilla can prevent the pancreatic damage associated with EBS. METHODS: A total of 173 patients with bile duct stones were treated by EBS. After conventional endoscopic retrograde cholangiography, EBS was performed by using a biliary dilatation catheter (balloon diameter: 8 mm). The duct was then cleared by using Dormia baskets or retrieval balloon catheters. Mechanical lithotripsy was performed before extraction when the stones were greater than 8 mm in diameter. In 81 patients, the dilated orifice was irrigated with 40-120 mL (50 +/- 37 mL) of 1:1,000,000 epinephrine (epinephrine group). In the remaining 92 patients, epinephrine irrigation was not performed (control group). Acute pancreatitis was defined by a serum amylase concentration fivefold greater than the upper limits of normal in association with abdominal pain. RESULTS: After EBS, serum amylase concentrations were significantly increased in both groups. However, the degree of hyperamylasemia was less in the epinephrine group than in the control group (617 +/- 611 vs 1037 +/- 1491 IU/L, P < 0.05). The incidence of pancreatitis was lower in the epinephrine group than in the control group (1.2 vs 7.6%, P < 0.05). CONCLUSIONS: Epinephrine irrigation is a simple and useful method to prevent post-EBS pancreatic damage and pancreatitis.

Adult↗

Intraductal ultrasonography for hepatocellular carcinoma with tumor thrombi in the bile duct: comparison with polypoid cholangiocarcinoma.

BACKGROUND AND AIM: Tumor thrombi in the bile duct caused by hepatocellular carcinoma (HCC), and cholangiocarcinoma show polypoid lesions on cholangiographic findings. This study prospectively compared the images of intraductal ultrasonography between HCC and polypoid cholangiocarcinoma. METHODS: In five patients with tumor thrombi in the bile duct caused by HCC, a 2.0 mm diameter ultrasonic probe with a frequency of 20 MHz was inserted into the bile duct via the transpapillary route (n = 4) or the transhepatic route (n = 1). The images were compared to that of 65 patients with cholangiocarcinoma. RESULTS: In all patients with HCC, intraductal ultrasonography showed a 'polypoid tumor with a narrow base'. In 16 of 65 patients with cholangiocarcinoma, it showed a 'polypoid tumor with a narrow base'. When intraductal ultrasonography showed a 'polypoid tumor with a narrow base', the findings of a positive 'nodule within a nodule' (40 vs 0%; P < 0.05), and the absence of a 'papillary-surface pattern' (80 vs 13%; P < 0.05) were more highly associated with tumor thrombi caused by HCC than to polypoid-type cholangiocarcinoma. CONCLUSIONS: Intraductal ultrasonography was useful to distinguish between tumor thrombi caused by HCC and polypoid-type cholangiocarcinoma.

Aged↗

Ropeway-type bile duct biopsy forceps with a side slit for a guidewire.

BACKGROUND: Transpapillary procurement of bile duct biopsy specimens is an effective diagnostic technique in cases of biliary structure. The utility of new ropeway-type bile duct biopsy forceps with a side slit for a guidewire was investigated in this study. METHODS: The 12 patients in this study had bile duct cancer (n = 3), cancer of the head of the pancreas (n = 4), gallbladder cancer (n = 1), and benign bile duct stenosis (n = 4). After endoscopic retrograde cholangiography, a guidewire was placed in the bile duct across the stenosis. The new forceps (1.8-mm diameter clamshell-type biopsy forceps without needle) was then introduced through the intact papilla along the guidewire. RESULTS: In all patients, sufficient tissue for histopathologic evaluation was obtained without complication. In one patient, biopsy specimens were selectively obtained of the left hepatic duct, which was impossible with conventional forceps. In another patient, histologic examination of specimens obtained by using this new forceps showed adenocarcinoma, whereas specimens obtained with a conventional forceps did not contain adenocarcinoma. However, in another patient, biopsy specimens obtained with a conventional forceps contained adenocarcinoma that was not evident in specimens obtained with the new forceps. Dislodgement of the guidewire during procurement of biopsy specimens occurred in 1 patient. In the other 11 patients, an endoscopic biliary drain was inserted over the guidewire. CONCLUSION: The new ropeway-type biopsy forceps is useful for selectively obtaining biopsy specimens of the bile duct. With this system, access for subsequent endoscopic biliary drainage is maintained.

Aged↗

Total enteroscopy with a nonsurgical steerable double-balloon method.

BACKGROUND: Deep insertion of an enteroscope by use of a push technique is difficult. A new method of enteroscopy was developed, a double-balloon method, to improve the access to the small intestine. METHODS: The new method uses 2 balloons, one attached to the tip of the endoscope and another at the distal end of an overtube. By using these balloons to grip the intestinal wall, the endoscope can be inserted further without forming redundant loops in the small intestine. This method was tried with a standard upper endoscope in 3 patients and with a longer enteroscope in 1 patient. RESULTS: Despite its short length the upper endoscope was successfully inserted as far as 30 to 50 cm beyond the ligament of Treitz in the 3 patients. In the fourth patient the longer enteroscope was successfully inserted beyond the ileo-cecal valve. CONCLUSIONS: The double-balloon method facilitates endoscopic access to the small intestine.

Adolescent↗

Pitfalls in endoscope reprocessing: brushing of air and water channels is mandatory for high-level disinfection.

BACKGROUND: Endoscopic transmission of pathogens has been reported. Guidelines have been formulated concerning the risk of infection via contaminated suction and accessory channels. Contamination of the other 2 channels for air and water has not been demonstrated. These channels were examined to clarify whether they require cleaning. METHODS: Endoscopes used for examinations were divided into 2 groups. Group A endoscopes (n = 20) were brushed along the air and water channels. Group B endoscopes (n = 22) were not. After machine reprocessing, specimens were obtained for bacterial culture. The residual protein was measured in the 2 channels by using amido black 10B dye, and results were compared between the 2 groups. RESULTS: With regard to the air channel, there were no contaminated endoscopes detected in either group. For the water channel, 1 endoscope in group B was positive whereas there were none positive in group A. With regard to quantification of residual protein, brushing diminished the level in both the air and the water channels. CONCLUSION: The air and water channels can become contaminated. Brushing every channel is mandatory for high-level disinfection. A redesign of the fundamental structure of endoscopes is proposed.

Air↗

Laparoscopic adhesiolysis for recurrent small bowel obstruction: long-term follow-up.

BACKGROUND: Recurrent small bowel obstruction caused by postoperative adhesions has traditionally been treated by conventional laparotomy, but laparoscopic management of acute small bowel obstruction has been reported. The aim of this study was to assess the long-term efficacy and clinical outcome of laparoscopic adhesiolysis for recurrent small bowel obstruction. METHODS: After conservative treatment, elective laparoscopic treatment was attempted in 17 patients hospitalized for recurrent small bowel obstruction after abdominal or pelvic surgery. RESULTS: Postoperative adhesions were identified laparoscopically in all patients. Laparoscopic treatment was possible in 14 patients (82.4%). Conversion to laparotomy was required for 3 patients (17.6%) because of intestinal perforation (n = 1) or a convoluted mass of adherent bowel (n = 2). Long-term follow-up was possible in 16 patients. Two recurrences of small bowel obstructions were noted over a mean follow-up period of 61.7 months. CONCLUSIONS: Laparoscopic adhesiolysis is a safe and effective treatment for recurrent small bowel obstruction. Conversion to laparotomy should be considered in patients with dense adhesions.

Feasibility Studies↗

Successful en bloc resection of a large superficial gastric cancer by using sodium hyaluronate and electrocautery incision forceps.

BACKGROUND: The advisability of endoscopic mucosal resection (EMR) for treatment of large superficial gastric cancers has been challenged. For more reliable en bloc resection, a new method of EMR was developed that uses a viscous substance, sodium hyaluronate, and two newly designed devices. METHODS: A large superficial gastric cancer was treated with this new EMR technique. Sodium hyaluronate was injected into the submucosa and mucosal incisions were made with a needle-knife. The newly developed incision forceps and flat-ended transparent hood were used for submucosal incisions. RESULTS: The large cancer was successfully resected endoscopically as a single piece of mucosa 6 cm in diameter without complication. Histopathologic evaluation of the specimen confirmed that the resection was curative. CONCLUSIONS: EMR with sodium hyaluronate along with two new devices may be a reliable method for en bloc resection of large superficial gastric lesions.

Aged↗

Acyclic neutral carrier-based polymer membrane electrode for a stimulant, phentermine.

Groups of dioxadicarboxylic diamides, which were developed as potential ionophores for inorganic cations, were found to act as ionophores for a stimulant, phentermine. Especially, N,N-dioctadecyl-N',N'-dipropyl-3,6-dioxaoctanediamide, which was originally developed as a lead ionophore and is commercially available from Fluka as lead ionophore I, was suitable for making a phentermine-selective electrode. The electrode constructed using this ionophore and bis(2-ethylhexyl) sebacate as a solvent mediator in a poly(vinyl chloride) membrane matrix discriminated between phentermine and analogous compounds more effectively than an electrode based on dibenzo-18-crown-6, a representative ionophore for organic ammonium ions. Moreover, the present electrode showed remarkably little interference by inorganic cations, such as Na+ and K+, as well as lipophilic quaternary ammonium ions including (C2H5)4N+ and (C3H7)4N+. The electrode exhibited a near-Nernstian response to phentermine in the concentration range of 2 x 10(-6) to 1 x 10(-2) M with a slope of 54.8 mV per concentration decade in 0.1 M MgCl2. The lower limit of detection was 7 x 10(-7) M. This electrode was applied to determine phentermine in a cationic-exchange resin complex of this stimulant, which is the general dosage form in medical use.

Journal Article↗

Multiple bile duct biopsies using a sheath with a side port: usefulness of intraductal sonography.

OBJECTIVE: We clarified the number of biopsies required to determine malignancy of the biliary tract on the basis of the type of bile duct tumor. SUBJECTS AND METHODS: Patients with a biliary tract malignancy (n = 33) and a benign biliary stenosis (n = 3) underwent biopsy via the percutaneous transhepatic route. We performed intraductal sonography using a 20-MHz probe with a 2.0-mm diameter. The sonographic findings were prospectively classified as polypoid, circular, or semicircular. The tip of a long 9-French sheath with a side port was wedged into the stenosis, and six specimens were obtained with a 1.8-mm-diameter forceps with serrated cups. RESULTS: When cholangiography or intraductal sonography showed a polypoid lesion, the sensitivity of two biopsies was 100% (6/6). When cholangiography showed a stenotic lesion, the sensitivity of nine biopsies (96%, 26/27) was superior to that of two biopsies (74%, 20/27; p < 0.05). When intraductal sonography showed a circular lesion, the sensitivity of three biopsies (100%, 14/14) was superior to that of a single biopsy (64%, 9/14; p < 0.05). When it showed a semicircular lesion, the sensitivity of nine biopsies (92%, 12/13) was superior to that of two biopsies (54%, 7/13; p < 0.05). CONCLUSION: Bile duct biopsy using a sheath with a side port has a high sensitivity. However, the number of biopsies required depends on the cholangioscopic and intraductal sonographic appearance of the tumor.

Aged↗

Evaluation of bioactive bone cement in canine total hip arthroplasty.

Total hip arthroplasties (THAs) were performed in beagle dogs using a bioactive bone cement (BABC) consisting of a silane-treated apatite- and wollastonite-containing glass-ceramic (AW glass-ceramic) powder and a silica glass powder as the filling particles and a bisphenol-A-glycidyl dimethacrylate-based resin (Bis-GMA-based resin) as the organic matrix. The outcomes were compared with the results of polymethylmethacrylate (PMMA) bone cement. The mechanical properties of the BABC were stronger than those of PMMA bone cement. The bonding strength of the BABC to bone in the dogs' femora increased with time and reached 3.7 MPa at 24 months after implantation whereas that of PMMA bone cement was 2.0 MPa (p < 0.05). Histological examination showed direct bonding between the BABC and the femoral bone for up to 24 months after implantation. However, with PMMA bone cement an intervening soft-tissue layer consistently was observed at the bone-cement interface. Direct bonding at the interface between the BABC and the bone through a calcium phosphorous layer 30 microm-thick was revealed by scanning electron microscopy. Femoral bone resorption was observed at 24 months after implantation in the BABC group, but it was not observed in the PMMA bone cement group. Direct bonding between BABC and the bone may have accelerated femoral bone resorption. Cement fractures of the BABC were observed on the acetabular side 24 months after implantation. Weak bonding between the BABC and an acetabular component made of ultrahigh molecular weight polyethylene (UHMWPE), relatively high elastic characteristics of BABC, and weakness of the calcium phosphorous layer formed on the surface of this cement seemed to lead to failure at 24 months on the acetabular side.

Animals↗

Microwave coagulation therapy: ex vivo comparison of MR imaging and histopathology.

We compared the findings of magnetic resonance (MR) images and pathological examination to determine whether or not MR images reflect pathological changes following microwave coagulation therapy (MCT) on liver tissue. We used microwave (generating frequency 2450 Mhz, wave length 12 cm, output 50 W, 60 second duration) to irradiate six canine livers under general anesthesia. After the animals were sacrificed, the livers were resected. The irradiated regions were cut with margins and divided into two pieces, one for MR study, and the other for pathological examination. The findings were compared. From the center to the marginal layer, the irradiated region presented 4/3 laminal patterns on T1/T2-weighted images: low/high, high/low, very high/high, and iso-low/high intensity. On gradient-echo imaging, the irradiated regions presented no decreasing signals using several echo time lengths. With hematoxylin and eosin stain, MR laminar patterns reflected the histopathological changes, as follows: a tissue loss area surrounding the inserted needle, low/high; decreased sinusoidal width with/without necrotic tissue, high/low; sinusoidal width dilation at the periphery, very high/high; and fatty degenerated tissue surrounding the irradiated area at the boundary of the normal hepatocytes, iso-low/high. The MR signal intensity, which reflected the histopathological changes, presented tissue characterization after MCT, and the macromolecular hydration effect influenced the high intensity on T1-weighted images.

Animals↗