Search PubMed⌕ Search

Biomedical subjects

K Gulabivala

Publications and source records attributed to K Gulabivala.

At least 37 records · Page 2Linked to original sources

Detection of simulated internal tooth resorption using conventional radiography and subtraction imaging.

OBJECTIVES: To compare the diagnostic accuracy of conventional radiography with digital subtraction imaging in the detection of simulated internal resorption. METHODS: Simulated resorption cavities were created by the sequential use of progressively larger round burs (ISO size range 006-016) in the labial wall of the coronal or apical thirds of the pulp chamber of the maxillary incisors of two cadavers. Five viewers examined 120 pairs of radiographs, one of each pair being baseline (no lesion) and the other with or without a lesion. The process was then repeated with subtraction images of the pairs of radiographs. Receiver Operating Characteristic (ROC) analysis was used to compare the diagnostic accuracy of the two imaging modalities. RESULTS: Using conventional radiography, the minimum lesion size detectable coronally was in the 'medium' range (ISO size 010 and 012 round burs), but only 'large' lesions (ISO size 014 and 016) could be detected in the apical region. The overall diagnostic accuracy of subtraction imaging was superior to conventional radiography but only significant (P<0.05) for coronal lesions. CONCLUSION: Subtraction radiography may be a useful tool for detecting and monitoring the progress of internal root resorption.

Cadaver↗

Effect of exposing dentine to sodium hypochlorite and calcium hydroxide on its flexural strength and elastic modulus.

AIM: The aim of this study was to evaluate the effect of sodium hypochlorite (NaOCl) solutions (3%, 5%) and saturated calcium hydroxide (Ca(OH)2) solution, individually and consecutively, on the flexural strength and modulus of elasticity of standardized dentine bars. METHODOLOGY: Standardized plano-parallel dentine bars (n = 121) were divided into five test groups and one control group. The control group 1 consisted of dentine bars, stored in normal saline until testing. The dentine bars in the five test groups were treated by exposure to the following solutions; group 2--3% NaOCl, 2 h; group 3--5% NaOCl, 2 h; group 4--saturated Ca(OH)2 solution, 1 week; group 5--3% NaOCl, 2 h and then saturated Ca(OH)2 solution 1 week; group 6--5% NaOCl, 2 h and then saturated Ca(OH)2 solution 1 week. The dentine bars were then loaded to failure in a three-point bend test. RESULTS: The data revealed a significant (P < 0.001) decrease in the modulus of elasticity and flexural strength of the dentine bars treated with 3% and 5% NaOCl. There was no significant difference in the flexural strength and the modulus of elasticity between the 3% and 5% NaOCl groups. Exposure to Ca(OH)2 significantly (P < 0.001) reduced the flexural strength but had no significant effect on the modulus of elasticity. The groups treated with sodium hypochlorite followed by calcium hydroxide did not have moduli of elasticity and flexural strengths that were significantly different from those treated only with sodium hypochlorite. CONCLUSIONS: NaOCl (3 & 5%) reduced the modulus of elasticity and flexural strength of dentine. Saturated Ca(OH)2 reduced the flexural strength of dentine but not the modulus of elasticity. Sequential use of NaOCl and Ca(OH)2 has no additional weakening effect.

Calcium Hydroxide↗

Effect of sodium hypochlorite on mechanical properties of dentine and tooth surface strain.

AIM: The aim of this study was to test the null hypothesis that sodium hypochlorite irrigation of root canals does not alter the properties of dentine and contribute to the weakening of root-treated teeth. METHODOLOGY: The effect of two concentrations (0.5%, 5.25%) of sodium hypochlorite (NaOCl) and saline on (i) the elastic modulus and flexural strength of machined dentine bars, and (ii) changes in strain of 'whole' extracted human teeth were evaluated. One hundred standardized plano-parallel dentine bars (> 11.7 x 0.8 x 0.8 mm) were randomly divided into the three groups, immersed for 2 h in the respective solutions and then subjected to a three-point bend test. Changes in strain of each of 10 teeth on cyclical nondestructive occlusal loading were measured using electrical resistance strain gauges bonded to the cervical aspects. Each tooth had its crown and enamel reduced and root canal prepared. These were irrigated sequentially in a series of four separate, 30-minute regimes; initial-saline, 0.5% NaOCl, 5.25% NaOCl and final-saline. The changes in strains after each irrigation regime were compared. RESULTS: There was a significant decrease in elastic modulus of the dentine bars immersed in 5.25% NaOCl compared with the saline group (P < 0.01). There was also a significant decrease in flexural strength of the dentine bars in the 5.25% NaOCl group compared to both the saline and 0.5% NaOCl groups (P < 0.01). The strain data from the nondestructive tooth loading tests revealed significant increases in tensile strain between the initial-saline and the final-saline stages (P < 0.01). Significant increases in compressive strains were also found between initial-saline and 5.25% NaOCl; and between 0.5% NaOCl and 5.25% NaOCl stages (P < 0.01). CONCLUSIONS: The null hypothesis was rejected, 5.25% NaOCl reduced the elastic modulus and flexural strength of dentine. Irrigation of root canals of single, mature rooted premolars with 5.25% NaOCl affected their properties sufficiently to alter their strain characteristics when no enamel was present.

Analysis of Variance↗

A survey of interfacial forces used during endosonic instrumentation of root canals.

AIM: The aim of this in-vitro study was to measure interfacial forces acting between root canal dentine and ultrasonic files during endosonic instrumentation. METHODOLOGY: Single-rooted teeth were mounted on a cantilevered aluminium beam to which two pairs of single element strain gauges were joined in a half-bridge configuration mounted at right angles to each other. The strain gauges were connected to an analogue-to-digital converter fitted in a microcomputer via a conditioning amplifier. This enabled strains to be recorded as a function of interfacial forces over a period of time. Twenty operators instrumented root canals using sizes 15, 20 and 25 ultrasonically energized K-type files. The lateral forces generated were calculated. RESULTS: The mean interfacial forces used varied widely between operators and files, ranging from 18 g to 149 g, but there was a consistency in the relative magnitude for each operator. The average force used by the operators increased with file size; the differences between file sizes were significant (P < 0.05). CONCLUSIONS: The range of forces measured is broader than previously reported and may have a bearing on possible uncontrolled dentine removal, even during ultrasonically activated irrigation.

Analog-Digital Conversion↗

Effect of access cavity location and design on degree and distribution of instrumented root canal surface in maxillary anterior teeth.

AIM: The null hypothesis tested in this study was that in single-rooted anterior teeth with simple root canal anatomy, different access cavity designs ('lingual cingulum', 'lingual conventional', 'incisal straight-line') do not influence the ability of endodontic files to plane the walls of the root canals. METHODOLOGY: Thirty extracted human maxillary anterior teeth were divided randomly into three groups for each access cavity. The access cavities were prepared according to predefined criteria and the roots embedded in individual polyvinyl-siloxane putty matrices. The matrices allowed these teeth to be split into buccal and palatal halves and to be reassembled. The split teeth enabled removal of pulpal remnants from the root canal system and the walls to be stained with an even layer of permanent black ink. Once dried, the split roots were reassembled in the putty matrices and a step-back filing technique was used to prepare the canals with water irrigation. The canal walls were examined for residual ink staining and scored by three independent assessors using an index devised for the purpose. RESULTS: There was good agreement between the assessors. None of the access cavities allowed file contact with the entire root canal wall. The overall (palatal and buccal sections) scores showed significant differences (P < 0.01) between the access cavity groups in the extent to which the canal walls could be filed. The straight-line incisal access cavity had the greatest proportion of instrumented root canal surface. The lingual cingulum access cavity was the worst in this respect. The differences in residual ink scores between the access cavity types were significant for the buccal halves (P < 0.01) but not for the palatal halves (P > 0.05). CONCLUSIONS: The null hypothesis was proven. Regardless of access cavity design, mechanical preparation did not allow instrumentation of the entire root canal wall. Straight-line access allowed the greatest proportion of the root canal wall to be instrumented and the lingual cingulum access the least.

Chi-Square Distribution↗

Some factors affecting the concentration of available chlorine in commercial sources of sodium hypochlorite.

AIMS: To evaluate the availability, effect of storage, dilution and heating on some commercial sources of sodium hypochlorite (NaOCl). METHODOLOGY: All pharmacies in a Regional Health Authority were telephone surveyed to establish the proprietary and nonproprietary NaOCl products available, their cost and concentration. Ninety-six freshly produced bottles of a commercially available thin household bleach (J. Sainsbury's) were randomly stored in four different modes (full 1 L bottles in dark at room temperature, half-empty 1 L bottles under the same conditions, full 200 mL bottles under the same conditions, full 200 mL bottles stored at 37 degrees C) up to 6 months. The available chlorine in the bleach solutions was evaluated at specific time intervals (0, 1, 2 weeks, 1, 2, 3, 4, 6 months) using iodometric titration. Four brands of commercially available bleaches (J. Sainsbury's Thin Household Bleach, Tesco's Value Bleach, Tesco's Red Label Bleach, Safeway's Savers Bleach) were diluted (by 1 : 1, 1 : 2 or 1 : 3 dilution factors) and samples taken from each dilution for titration to test predictability. NaOCl solutions (5% w/w) were heated in covered or uncovered beakers up to 60-85 degrees C. Samples were taken from each beaker at time 0 and each h up to 4 h, for titration. RESULTS: Of the 116 pharmacies, 33% could supply a proprietary product and 53% a nonproprietary product. In all, 78% were able to supply a NaOCl product. There was no significant difference (P < 0.05) in available chlorine at baseline between the different modes of storage. After storage at room temperature for 6 months, there were no significant differences (3% of original; P > 0.05) between the different modes of storage. When the storage temperature was 37 degrees C, however, there was a significant difference (38% of original; P < 0.01) at 6 months. Comparison of baseline with the concentrations of available chlorine at 6 months showed significant differences (P < 0.01) for all conditions. The available chlorine concentration in four brands of 'thin' supermarket bleaches could be predictably reduced according to the dilution factor. When 5% NaOCl was heated to 60-85 degrees C for up to 4 h, the available chlorine was increased to 6% in covered solutions and 9% in uncovered solutions. CONCLUSIONS: Both proprietary and nonproprietary solutions of NaOCl should be relatively easily obtainable in the UK. Stored under appropriate conditions, commercially available thin bleaches and nonproprietary solutions of NaOCl may be diluted to obtain predictable concentrations. Heating solutions of NaOCl may cause unpredictable changes to the concentration, depending upon conditions.

Air↗

An in vitro evaluation of the antimicrobial efficacy of irrigants on biofilms of root canal isolates.

AIM: The bactericidal effect of four antimicrobial agents was investigated against single-species biofilms derived from a range of root canal isolates. METHODOLOGY: Single-species biofilms of Prevotella intermedia, Peptostreptococcus micros, Streptococcus intermedius, Fusobacterium nucleatum and Enterococcus faecalis were generated on membrane filter discs and subjected to 15 min or 1 h incubation with 5 p.p.m. colloidal silver, 2.25% sodium hypochlorite (NaOCl), 0.2% chlorhexidine, 10% iodine or phosphate buffered saline (PBS) as a control. The antimicrobial activity of the agents was neutralized and the bacterial cells were harvested from the discs by vortexing, serially diluted in reduced transport fluid, plated on fastidious anaerobe agar containing 5% horse blood, incubated anaerobically and colony-forming units calculated. RESULTS: Iodine and NaOCl were more effective than chlorhexidine except against P. micros and P. intermedia where they were all 100% effective. Iodine and NaOCl elicited a 100% kill after 1 h incubation for all strains used. However, after 15 min, they showed differing bactericidal effects depending on the strain. None of the agents were effective against F. nucleatum after 15 min but NaOCl, iodine and chlorhexidine were all effective after 1 h. Colloidal silver was generally ineffective. CONCLUSIONS: The effectiveness of a particular agent was dependent on the nature of the organism in the biofilm and on the contact time. NaOCl was generally the most effective agent tested, followed by iodine. However the clinical efficacy of these agents must be considered in light of the complex root canal anatomy and polymicrobial nature of root canal infections.

Anti-Infective Agents, Local↗

The influence of preparation technique and sodium hypochlorite on removal of pulp and predentine from root canals of posterior teeth.

AIM: To test the null hypothesis that removal of pulp tissue and predentine from root canals of multirooted teeth is not significantly different when performed by one of two mechanical preparation techniques in conjunction with either water or 3% sodium hypochlorite (NaOCl) irrigation. METHODOLOGY: Forty-six freshly extracted premolar or molar teeth, with pulps vital at the time of extraction, were assigned to four groups balanced by anatomy (group 1, step-back filing/NaOCl; group 2, step-back filing/water; group 3, automated rotary/NaOCl; group 4, automated rotary/water). Preparation was undertaken by a single operator and the volumes of irrigant recorded for each tooth. One root from each tooth was prepared for transverse histological assessment at eight levels, including one at and two apical to the working length. A validated index was used to measure the presence and location of residual pulp tissue and predentine. RESULTS: No statistically significant differences were found in the frequency with which residual pulp tissue or predentine were observed amongst the groups. Coronal parts were more frequently devoid of pulp tissue and predentine than the apical. Canals were frequently occluded with residual pulp tissue apical to the working length. There was a trend for better pulp and predentine removal in accessible parts of the canal as a function of rotary preparation and NaOCl irrigation. The isthmus had residual pulp tissue less frequently in the NaOCl groups. Accessory anatomy was unaffected regardless of technique or irrigant. CONCLUSIONS: Pulp tissue and predentine removal were not significantly different between a step-back filing and an automated rotary preparation technique in conjunction with water or NaOCl.

Bicuspid↗

Root and canal morphology of Burmese mandibular molars.

AIM: To study the root canal morphology of Burmese mandibular molars using a canal staining and tooth clearing technique. METHODOLOGY: Mandibular molars (331) were collected from indigenous Burmese patients and designated; first (139), second (134), third (58) molars. Following pulp tissue removal and staining of the canal systems with Indian ink, the teeth were decalcified and rendered clear with methyl salicylate. Under magnification (x3), the following features were evaluated: (i) root number and morphology, (ii) number of canals per root, (iii) root canal configuration (Vertucci's classification), (iv) number of apical foramina per root, (v) number and location of lateral canals and (vi) the presence of intercanal communications. RESULTS: Most of the mandibular molars had two separate roots (90% in first molars, 58% in second molars, 53% in third molars) and three-rooted teeth were (10%) confined to first molars. C-shaped roots occurred in 22.4% of mandibular second molars and a further 14.9% had two fused roots. The majority (81-100%) of conical distal roots possessed a simple type I (single canal) configuration. Whilst the canal system of mesial roots was more complex: 52-85% contained two canals, of which type II (two orifices, one foramen) and type IV (two separate canals) were the most prevalent. A broad range of 6.5-70% had intercanal communications. Fused/single-rooted molars had a wide variety of canal system types but intercanal communications were rare except in C-shaped roots (33%) of second molars. The majority of roots of all molars contained one or two apical foramina (91-96%) and the apical third had the highest prevalence of lateral canals. CONCLUSIONS: There was a high prevalence of three-rooted mandibular first molars and C-shaped roots/canals in mandibular second molars from a Burmese population. Conical roots tend to have simple canal systems, whilst flatter/broader roots have more complex canal systems.

Asian People↗

Root and canal morphology of Burmese maxillary molars.

AIM: To investigate the root and canal morphology of Burmese maxillary molars using a canal staining and tooth clearing technique. METHODOLOGY: Maxillary molars (239) were collected from indigenous Burmese patients and designated; first (90), second (77), third (72) molars. Following pulp tissue removal and canal system staining with Indian ink, the teeth were decalcified with 10% nitric acid, dehydrated and cleared with methyl salicylate. The following features were evaluated: (i) number of roots and morphology; (ii) number of canals per root: (iii) root canal configuration (Vertucci's classification); (iv) number of apical foramina per root; (v) number and location of lateral canals; and (vi) the presence of intercanal communications. RESULTS: All first and second molars had three separate roots, whilst third molars had one of five different root forms, of which three separate (25%) or fused (31%) roots were most prevalent. The majority of palatal (100%) and disto-buccal (96%) roots possessed one canal (type I). The prevalence of mesio-buccal roots with two canals decreased from first to third molars (68%, 49%, 39%, respectively); type II (two orifices, one apical foramen) and IV (two orifices, two apical foramina) configurations were the most common. Single/fused rooted third molars had a range of number and type of canals. Most roots in all molars had one apical foramen, those with four apical foramina were confined to third molars. Intercanal communications were most prevalent in mesio-buccal roots and two/three fused rooted third molars. Lateral canals were most prevalent in the apical third of the roots of all molars. CONCLUSIONS: The mesio-buccal roots of Burmese maxillary molars possessed a variety of canal system types. Over 50% of the first and second molars had a second mesio-buccal canal, of which over 20% had intercanal communications. The palatal and disto-buccal canals mainly had type I canals. Lateral canals were equally prevalent in all tooth types but were most common in the apical third.

Adult↗

A new in vitro model for the study of microbial microleakage around dental restorations: a preliminary qualitative evaluation.

AIM: The aim of this study was to develop an in vitro model to replicate microbial microleakage at a tooth/ restoration interface using a constant depth film fermentor (CDFF). METHODOLOGY: Amalgam restorations were placed in machined bovine dentine cylinders and sealed externally with varnish, leaving a 1-mm perimeter exposed around the tooth/restoration interface. The dentine cylinders were housed in a CDFF and 300-microm thick microcosm dental plaques were grown over their exposed surfaces. The biofilms were maintained with a mucin-containing artificial saliva for up to 8 weeks. Cylinders were aseptically removed from the CDFF (at 1, 2, 4, & 8 weeks) and surface-decontaminated with validated protocols prior to splitting and sampling of apposing amalgam and dentine surfaces. Scanning electron microscopy (SEM) was used to ascertain the position and structure of the bacterial aggregates. Bacterial viability was determined by vital staining of the bacteria in situ. RESULTS: At all sampling times, SEM showed cocci, rods and filaments on both amalgam and dentine surfaces; some originated as cascades from the surface biofilm and extended into the tooth/restoration microspace. Vital staining showed the majority of bacteria from both dentine and amalgam surfaces to be viable. CONCLUSION: This preliminary investigation showed that the CDFF may be a valuable tool for the in vitro study of the dynamics of microbial microleakage around dental restorations.

Animals↗

Comparison of clinical outcome of periapical surgery in endodontic and oral surgery units of a teaching dental hospital: a retrospective study.

OBJECTIVES: The aims of this retrospective study were (1) to compare the outcome of periapical surgery performed in endodontic and in oral surgery units of a teaching dental hospital and (2) to evaluate the influence of factors affecting outcome. STUDY DESIGN: A total of 176 teeth (endodontic unit, 83; oral surgery unit, 93) surgically treated more than 4 years previously were examined clinically and radiographically by means of strict criteria. Multiple logistic regression analysis was used. RESULTS: The rate of complete healing for patients treated in the endodontic unit (37.4%) was significantly (P = .009) higher than that for patients treated in the oral surgery unit (19.4%). The technical quality of surgery (P < .001), placement of root-end filling (P = .039), absence of a preoperative periapical lesion (P = .042), absence of a post (P = .047), and presence of an adequate coronal restoration (P = .056, odds ratio = 3.71) had significant effects on treatment outcome. CONCLUSION: The technical quality of periapical surgery, the presence of a periapical lesion, and adequate apical and coronal seal are important prognostic determinants of successful periapical surgery.

Adult↗

An introduction to meta-analysis within the framework of multilevel modelling using the probability of success of root canal treatment as an illustration.

OBJECTIVE: To introduce the statistical methodology of meta-analysis within the framework of multilevel modelling (MLM) using an illustrative example. BASIC RESEARCH DESIGN: In meta-analysis it is important that the quantitative pooling of study results should be carried out in conjunction with careful consideration of the variation apparent between studies. If statistical heterogeneity is found to be significant, it is due, at least in part, to clinical heterogeneity. It is possible to account for clinical heterogeneity by including covariates that are thought to be responsible, using meta-regression. CLINICAL SETTING: A total of 38 studies of root canal treatment outcome were identified as being suitable for introducing the meta-analysis methodology. Two covariates were considered for modelling: a 'loose' or 'strict' (loose--incomplete radiographic healing; strict--complete radiographic healing) criterion for judging outcome of treatment and the year in which the study was performed. RESULTS: There was considerable statistical heterogeneity between the study results. The effect of employing loose criteria for judging success significantly increased the probability of success when compared to employing strict criteria. Furthermore, the variance between studies was significantly reduced when this covariate was included in the modelling process when compared to the variation estimated in the model which did not consider covariates. CONCLUSION: MLM is a good facilitator for meta-analysis and meta-regression.

Analysis of Variance↗

A survey of interfacial forces used during filing of root canals.

The pattern of dentine removal during endodontic instrumentation is influenced by many factors including the interfacial forces applied by the operator. The aim of this study was to investigate the influence of operators and different sizes and types of instruments on the magnitude of these interfacial forces. Single-rooted teeth were mounted on a cantilevered aluminium beam to which two pairs of single element strain gauges were joined in a half-bridge configuration and mounted at right angles to each other. The strain gauges were connected to an analogue-to-digital converter fitted in a micro-computer via conditioning amplifiers. This enabled strains to be recorded over a period of time. Twenty operators instrumented root canals using a series of hand instruments for 1 min each. The mean interfacial forces used by operators demonstrated a wide variation ranging from 9.06 g to 149.42 g (range of forces from 0-331 g) but there was a consistency in the relative magnitude for each operator. The 20 operators could be divided into 13 groups which were significantly different (alpha = 0.05) from each other. There were significant differences (alpha = 0.05) between the forces used for each of the K-Flex files (15, 25, 35, 45, and 70), the force increasing with the file size. There was also a significant difference (alpha = 0.05) in the forces used between the Flexofile (#25) and the #25 K-Flex and Hedström files. However, there was no significant difference between the K-Flex and Hedström files.

Amplifiers, Electronic↗

The influence of interfacial forces and duration of filing on root canal shaping.

The aim of this study was to investigate the possible relationship between interfacial forces, duration of instrumentation and effectiveness of root canal shaping by filing. All factors were standardised except the manner of manipulation of the files and the dependent variables (interfacial force and duration of filing). The outcome measured was the final prepared canal shape. The study tested the hypothesis that if interfacial forces and duration of filing had predictive value for effective canal shaping, a relationship between them should be apparent. If it was not, it could be inferred that the remaining uncontrollable variable, "manner of file manipulation" had a dominating influence. 18 operators used a standard filing technique to instrument a root canal each in single rooted teeth matched for anatomy. The teeth were mounted in a custom-made transducer designed to measure laterally applied interfacial forces between file and dentine. The length of time taken with each instrument in the series was measured giving a total duration of instrumentation. The final canal shape measured by standardised "before" and "after" radiographic images of the roots was judged against an "ideal" canal shape calculated from the size of instruments used and based on the preliminary canal shape. Although some trends were revealed, no obvious relationship was demonstrated between interfacial force, duration of filing and final canal shape. Operators clearly used a range of interfacial forces characteristic for each individual and for the different file sizes. Both light and heavy forces could produce a satisfactory canal shape. Use of light or heavy forces did not obviously affect speed of preparation. Tactile discrimination was not dependent on use of light or heavy forces. It was inferred that the "manner of file manipulation" remained undefined and was probably the dominant factor influencing outcome of canal shaping.

Analysis of Variance↗

Reliability of radiographic observations recorded on a proforma measured using inter- and intra-observer variation: a preliminary study.

AIM: The aim of this preliminary study was to test the reliability of radiographic evaluation of features of endodontic interest using a newly devised data collection system. METHODOLOGY: Twelve endodontic MSc postgraduate students and one specialist endodontist examined sample radiographs derived from a random selection of 42 patients seen previously on an Endodontic New Patient Clinic (EDI). Each student examined a random selection of 8-9 roots on periapical radiographs of single- and multirooted teeth, with and without previous root canal therapy and 3-4 dental panoramic tomograms (DPTs). A total of 100 roots were examined. A proforma was used to record observations on 67 radiographic features using predefined criteria. Intra-observer agreement was tested by asking the students to re-examine the radiographs. The principle investigator and the specialist endodontist examined the same radiographs and devised a Gold Standard using the same criteria. This was compared with the student assessments to determine inter-observer variation. The postgraduates then attended a revision session on the use of the form. Each student subsequently examined 8-9 different roots from the pool of radiographs. A further assessment of inter-observer variation was made by comparing these observations with the Gold Standard. RESULTS: Of the 67 radiographic features, only 25 had sufficient response to allow statistical analysis. Kappa values for intra- and inter-observer variation were estimated. These varied depending on the particular radiographic feature being assessed. Fifteen out of 25 intra-observer recordings showed 'good' or 'very good' Kappa agreement, but only three out of 25 inter-observer observations achieved 'good' or 'very good' values. Inter-observer variation was improved following the revision session with 16 out of 25 observations achieving 'good' or 'very good' Kappa agreement. CONCLUSIONS: Modification to the proforma, the criteria used, and training for radiographic assessment were considered necessary to improve the accuracy and reproducibility of the observations entered.

Data Collection↗

The preparation of periapical lesions for flow cytometry.

AIM: To devise an optimal protocol and to analyse the leucocyte composition of periapical (PA) lesions by flow cytometry. METHODOLOGY: PA lesions were mechanically agitated, with and without proteolysis. This was with either 0.2% collagenase alone, or in combination with 0.02% DNA-ase in serial incubations until all tissue was digested. The efficacy of each method was assessed by counting total cell yield and cell viability. Phenotype stability was gauged by the percentage of peripheral blood leucocytes (PBL) which expressed CD45RB, CD3, CD20, CD4 and CD8 before and after mechanical and collagenase treatment. RESULTS: Disaggregation of PA lesions was superior if collagenase was present, but cell clumping was problematic unless the DNA-ase was also added, and serial digestion with this combination produced optimal cell yield and viability. Nevertheless, the total number of cells released rarely exceeded 105, though viability was in excess of 80%. Mechanical agitation and proteolysis adversely affected PBL phenotypes, but collagenase digestion limited to 10 min caused least damage. Flow cytometric analysis of disaggregated PA lesions failed to identify more than 7.9% (mean, range 6-10%) CD45RB + cells. CONCLUSIONS: Because of the necessity for single cell suspensions, flow cytometry is not easily applied to the analysis of leucocytes in PA lesions, and further refinements in tissue disaggregation and cell preparation are required.

Antigens, CD↗

A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique.

AIM: This study was designed to use two methods of temperature measurement to analyse and quantify the in vitro root surface temperature changes during the initial stage of the continuous wave technique of obturation of 17 single-rooted premolar teeth with standard canal preparations. METHODOLOGY: A model was designed to allow simultaneous temperature measurement with both thermocouples and an infrared thermal imaging system. Two thermocouples were placed on the root surface, one coronally and the other near the root apex. A series of thermal images were recorded by an infrared thermal imaging camera during the downpack procedure. RESULTS: The mean temperature rises on the root surface, as measured by the two thermocouples, averaged 13.9 degrees C over the period of study, whilst the infrared thermal imaging system measured an average rise of 28.4 degrees C at the same sites. Temperatures at the more apical point were higher than those measured coronally. After the first wave of condensation, the second activation of the plugger in the canal prior to its removal always resulted in a secondary rise in temperature. The thermal imaging system detected areas of greater temperature change distant from the two selected thermocouple sites. CONCLUSIONS: The continuous wave technique of obturation may result in high temperatures on the external root surface. Infrared thermography is a useful device for mapping patterns of temperature change over a large area.

Adult↗