Search PubMed⌕ Search

Biomedical subjects

K G Bis

Publications and source records attributed to K G Bis.

31 records · Page 2Linked to original sources

Endometriosis: appearance and detection with conventional and contrast-enhanced fat-suppressed spin-echo techniques.

Suspected pelvic endometriosis was prospectively evaluated in 31 women with T1- and T2-weighted conventional spin-echo (CSE) magnetic resonance imaging alone and in combination with T1-weighted fat-suppressed (T1FS) and gadolinium-enhanced T1FS (Gd-T1FS) spin-echo techniques. Images were grouped for interpretation and comparison as follows: (a) CSE alone, (b) CSE/T1FS, and (c) CSE/T1FS/Gd-T1FS. All patients underwent surgery within 3 months of imaging, and 21 patients were found to have endometriosis: 59 endometriomas (26 large and 33 small) and 51 sites of implants were seen. With CSE images, 23 large and six small endometriomas were detected. With CSE/T1FS images, 25 large and 14 small endometriomas were identified. With CSE/T1FS/Gd-T1FS images, 24 large and 14 small endometriomas were detected and ill-defined areas of enhancement were noted in 22 sites throughout the pelvis. These corresponded to endometriotic implants seen at surgery in 14 sites. The sensitivity, specificity, and accuracy, respectively, for the detection of endometriosis were 76%, 60%, and 71% for CSE, 86%, 50%, and 74% for CSE/T1FS, and 81%, 50%, and 71% for CSE/T1FS/Gd-T1FS images. No significant differences (P > .1) between image combinations for correctly identifying patients with and without endometriosis were seen. The difference in sensitivity between CSE and CSE/T1FS and between CSE and CSE/T1FS/Gd-T1FS images for detecting small endometriomas was significant (P = .03).

Adipose Tissue↗

MR imaging of myositis ossificans: variable patterns at different stages.

Five patients with a palpable mass at presentation underwent magnetic resonance (MR) imaging. The final diagnosis was myositis ossificans (MO). MR imaging features, particularly after injection of gadopentetate dimeglumine, mimicked those of an inflammatory mass or neoplasm. The lesions were excised in three patients, and the images were correlated with histologic findings. Three different appearances were noted on MR images, corresponding to the stages of maturation of MO. Two cases involved early-stage lesions, and T1-weighted MR images showed a mass with homogeneous intermediate signal intensity. Both lesions showed rim enhancement after contrast agent injection and high signal intensity on T2-weighted images. Pathologic specimens demonstrated stroma with masses of spindle cells in which osteoid production was interspersed. The enhanced rim of the lesion mimicked the expected MR appearance of an abscess or necrotic tumor. Areas of enhancement in adjacent muscle were also seen on postcontrast T1-weighted images. Intermediate-stage MO was present in one case; there was evidence of a thin rim of calcification on plain radiographs and fatty changes in the lesion on T1-weighted images, corresponding with histologic findings. One case of a mature lesion showed a considerable degree of peripheral calcification both on MR images and at histology. MR imaging is nonspecific in the diagnosis of early-stage MO.

Abscess↗

Giant cell tumor of the tendon sheath in the ankle: MRI with pathologic correlation.

We report a case of Giant cell tumor of the tendon sheath involving the ankle, wherein spin-echo (T1- and T2-weighted), gradient-echo, and dynamic contrast-enhanced sequences were performed, and the tumor was noted to be very vascular. To the best of our knowledge, the use of gradient-echo sequences and the pattern of enhancement by time-intensity curves has not been reported earlier.

Adult↗

Hypogenetic lung syndrome: functional and anatomic evaluation with magnetic resonance imaging and magnetic resonance angiography.

A case of hypogenetic lung syndrome is described in which anatomic and functional information was obtained with use of ECG-triggered turbo (fast) spin-echo, cine, velocity-encoded cine, and contrast-enhanced magnetic resonance angiography (MRA) sequences. To the best of our knowledge, a complete functional and anatomic study of hypogenetic lung syndrome with MRI has not been previously reported.

Female↗

Gradient-echo perfusion imaging of musculoskeletal abnormalities with contrast-enhanced two-dimensional fat-saturation FLASH.

The objective of this study was to evaluate the utility of MR perfusion imaging of various musculoskeletal lesions with a contrast-enhanced two-dimensional fat saturation fast low angle shot (FLASH) sequence and to assess the potential of this technique for distinguishing malignant from benign conditions. Thirty-six musculoskeletal lesions were studied at 1.5 T. The signal intensity of the lesions, adjacent artery, muscle, bone marrow, and fat were plotted against time. The time to peak enhancement, time to maximum signal intensity, percent enhancement, rate of peak enhancement, and rate of enhancement parameters were calculated. Because of a significant overlap between malignant and benign conditions, accuracy rates were lower than reported previously. The best parameter based on these values was the rate of peak enhancement (sensitivity, 84.6%; specificity, 65.2-66.6%; positive predictive value, 57.8-68.7%). Fat saturation gradient-echo MR perfusion imaging allows for a rapid assessment of the vascularity of musculoskeletal pathology; however, a significant overlap persists between malignant neoplasms and several benign conditions.

Adipose Tissue↗

Contrast-enhanced 3D MRA with centric ordering in k space: a preliminary clinical experience in imaging the abdominal aorta and renal and peripheral arterial vasculature.

The objective of this study was to determine the clinical utility of a contrast-enhanced, centric reordered, three-dimensional (3D) MR angiography (MRA) pulse sequence in imaging the abdominal aorta and renal and peripheral lower extremity arteries. Twenty-eight MRA studies were performed on 23 patients and four volunteers at 1.5 T using a 3D contrast-enhanced, centric reordered pulse sequence. In 20 patients, the abdominal aorta and renal arteries were imaged, and in seven patients, the lower extremity arteries were imaged. In 19 patients, a total of 51 renal vessels were evaluated (33 renal arteries using .1 mmol/kg of gadopentetate dimeglumine and 18 renal arteries using .2 mmol/kg of gadoteridol). A total of 70 peripheral arterial segments were assessed using .2 mmol/kg of gadoteridol. Correlation with conventional angiography was made for the following 14 cases: renal artery stenosis (four cases), abdominal aortic stenosis (one case), arteriovenous fistula in a transplant kidney (one case), renal arteriovenous malformation (one case), common iliac artery aneurysms (one case), and peripheral lower extremity (six cases). Of the 70 peripheral arterial segments evaluated, in 35, there was correlation with x-ray angiography. The mean percent of aortic signal enhancement was significantly higher in the .2 mmol/kg dose group (370.8 +/- 190.3) than in the .1 mmol/kg dose group (184.5 +/- 128.9) (P = .02). However, there was no apparent difference between the two doses for visualization of the renal and accessory renal arteries. There was concordance between the contrast-enhanced 3D MRA studies and conventional angiography in all cases of renal artery and peripheral arterial stenoses and occlusions, including visualization of reconstituted peripheral arterial segments. There was no evidence of spin dephasing effects at sites of stenoses on the 3D contrast-enhanced MRA studies. Contrast-enhanced, centric reordered, 3D MRA can rapidly image the abdominal aorta and renal and accessory renal arteries, as well as peripheral lower extremity arteries, with high resolution. Accurate depiction of the vascular lumen at sites of stenosis is made because of the lack of spin dephasing effects, even with hemodynamically significant stenoses. Additional larger clinical trials are required with this promising technique.

Adult↗

Pelvic fistulas: appearances on MR images.

BACKGROUND: This multi-institutional study examines appearances of pelvic fistulas on magnetic resonance (MR) images. METHODS: MR images of 46 patients with documented fistulas from five teaching hospitals were retrospectively reviewed. All patients underwent T1-weighted (T1WI), T2-weighted (T2WI), and intravenous gadolinium chelate-enhanced T1-weighted (Gd-T1WI) images. Imaging sequences were separately and then collectively reviewed. The following determinations were made: fistula detection, fistula morphology and signal intensity, and the presence of associated abnormalities. Fistulas were classified into two categories: (1) fistulas that communicate with the bladder and (2) fistulas that do not communicate with the bladder. Fistulas within these two groups were subclassified further. The presence of fistulas was documented by surgery (five patients), endoscopy (six patients), fistulogram (20 patients), or physical exam (15 patients). RESULTS: Among the 46 patients, 53 fistulas were documented by means other than MR. Overall T1WI, T2W1 and Gd-T1WI images demonstrated 23, 31, and 39 of 53 fistulas, respectively. Gd-T1W1 detected significantly more fistulas than T1W1 (p < 0.05). Bladder fistulas were better shown on Gd-T1WI (8/15 fistulas) than on T1WI and T2WI (2/15 and 3/15) (p < 0. 05). Nonbladder fistulas were demonstrated by T1WI, T2WI, and Gd-T1WI images in 21, 28, and 31 of 38 fistulas, respectively. Among all fistulas, perianal fistulas (a subcategory of nonbladder fistula) had the highest detection by T1WI, T2WI, and Gd-T1WI in 19, 20 and 22 of 23 fistulas, respectively. On T1WI, 19 of 23 detected fistulas were low in signal intensity. On T2WI, 28 of 39 detected fistulas were high in signal intensity. On Gd-T1WI images, 29 of 40 fistulas were low in signal intensity, with enhanced tract wall. CONCLUSION: Bladder fistulas were best shown on Gd-T1WI, which was significantly greater than on T1WI or T2WI. Nonbladder fistulas were comparably shown by all techniques, with all performing modestly well. Perianal fistulas were shown equally well by all MR sequences and were the fistulas demonstrated with the highest sensitivity on MR images.

Adolescent↗

Juxtaglomerular cell tumor: MR findings.

Juxtaglomerular (JG) cell tumor is a rare benign neoplasm of the kidney that typically presents with hypertension, secondary hyperaldosteronism, hypocalcemia, and hyperreninism. We describe a case of JG cell tumor diagnosed with MRI.

Adolescent↗

3D breath-hold contrast-enhanced MRA: a preliminary experience in aorta and iliac vascular disease.

PURPOSE: Our goal was to describe a 3D breath-hold (3D BH) contrast-enhanced MRA technique and apply the technique to patients with known or suspected aortic and iliac artery disease. METHOD: A fat-suppressed 3D GRE pulse sequence was designed with a total of 16 partition encodings. This took < 24 s for data acquisition in the abdomen and pelvis and was easily achieved during a single breath-hold. The technique was applied to 26 patients who presented with either known or suspected abdominal aortic or iliac vascular diseases. For comparison, in 19 patients a 2D TOF MRA pulse sequence with a traveling saturation band was used. Angiographic correlation was made in 18 studies. RESULTS: The 3D BH MRA was easily applicable in the evaluation of vascular anatomy and pathology. In three cases, it was superior to 2D TOF and conventional angiography for visualizing clot within the wall of an aneurysm in the abdominal aorta. In 20 cases, both MRA techniques overestimated the degree of stenosis in the lower peripheral vessels; however, this was more pronounced on 2D TOF. In five cases, the aneurysm wall was clearly defined by 3D BH MRA, whereas there was considerable signal loss in 2D TOF due to complex flow. With 3D BH MRA, the entire vessel territory both in abdominal aorta and in iliac vessels was visualized in all cases without signal falloff in the FOV. Breath-holding provided static images of the vessels that were free of blurring due to respiratory motion. CONCLUSION: Preliminary experience suggests that 3D BH with its distinct advantage of speed may serve as a useful screening tool for patients who cannot have conventional angiography or tolerate a lengthy MR examination of the abdominal aorta and iliac arteries.

Adult↗

Pelvic endometriosis: MR imaging spectrum with laparoscopic correlation and diagnostic pitfalls.

Endometriosis is a common multifocal disease involving a number of anatomic sites in the pelvis. Although laparoscopy is the standard of reference for diagnosis, magnetic resonance (MR) imaging is a noninvasive method for evaluating areas inaccessible to laparoscopy. A large endometrioma (> or = 1 cm in diameter) appears as a homogeneously hyperintense mass on T1-weighted MR images and as a low-signal-intensity mass with areas of high signal intensity on T2-weighted images. A small endometrioma may be indicated when a pelvic mass less than 1 cm in diameter is hyperintense on T1-weighted images irrespective of its appearance on T2-weighted images. Endometriosis may also manifest as multiple, homogeneously hyperintense cysts on T1-weighted images. Involvement of the alimentary tract or bladder can appear as areas of high signal intensity. Although MR imaging is limited in its ability to depict small endometrial implants and adhesions, the advantages of MR imaging over laparoscopy include the ability to characterize endometriotic lesions and to evaluate extraperitoneal sites of involvement, contents of a pelvic mass, or lesions hidden by dense adhesions. The roles of the two modalities are therefore complementary. Knowledge of the variety of MR imaging appearances of endometriosis and organ involvement within the pelvis is important for guiding a subsequent laparoscopic examination.

Adult↗

Contrast-enhanced MR angiography of the mesenteric circulation: a pictorial essay.

Outstanding results have been achieved with magnetic resonance (MR) angiography, which has become competitive with conventional angiography as a vascular imaging technique. With the advances in gradient technology and the capability of imaging vessels in a single breath hold, one can track an intravenous bolus of paramagnetic contrast agent and evaluate the entire mesenteric circulation. Use of a breath-hold technique obviates the problem of motion artifact. Use of targeted maximum-intensity projection images from the three-dimensional (3D) volume data allows evaluation of the vascular anatomy at different phases (arterial and venous) of contrast enhancement. MR angiography performed with a contrast-enhanced breath-hold fat-suppressed 3D technique allows visualization of the superior mesenteric vessels, celiac artery, and portal vein in healthy subjects. Pathologic conditions of the mesenteric vessels that can be identified with this technique include stenosis or occlusion of the superior mesenteric artery, celiac artery aneurysm, thrombosis of the superior mesenteric vein, portal hypertension with varices, and vascular invasion by pancreatic carcinoma.

Adult↗

MR angiography of the thoracic aorta with an electrocardiographically triggered breath-hold contrast-enhanced sequence.

An electrocardiographically (ECG) triggered breath-hold contrast material-enhanced magnetic resonance (MR) angiography sequence has been developed for imaging the thoracic aorta. A three-dimensional (3D) gradient-echo sequence is used with a contrast material bolus. Forty-nine patients with various aortic abnormalities and five healthy volunteers underwent imaging with the sequence. All studies were performed in a single breath hold. ECG-triggered breath-hold contrast-enhanced MR angiography was tolerated in 48 of the 49 patients. The images demonstrated no respiratory motion artifacts and diminished pulsation artifacts. The cardiac chambers, aortic root, ascending and descending aorta, aortic arch, proximal arch vessels, and proximal coronary arteries were clearly demonstrated and not obscured by ghost artifacts. The 3D data set allowed excellent multiplanar reformation, permitting orthogonal or oblique views of the vascular anatomy. A variety of congenital and acquired abnormalities were clearly identified. When this sequence is used, it is important to evaluate both the maximum-intensity projection and source images. Delayed imaging should be performed to detect late filling. In conjunction with cine MR and T1-weighted spin-echo imaging, ECG-triggered breath-hold contrast-enhanced MR angiography should be considered the technique of choice for imaging the thoracic aorta.

Aorta, Thoracic↗