Comparison of double-bag and Y-set disconnect systems in continuous ambulatory peritoneal dialysis: a randomized prospective multicenter study.

We performed a multicenter, single-blinded, prospective randomized study on the use of a double-bag disconnect system (B) versus a Y-set disconnect system (Y). The peritonitis rate, exit site infection, clinical outcome, and patients' acceptance to the procedure were assessed. A total of 120 new end-stage renal failure patients of three regional hospitals were randomized: 60 each to the B and the Y systems. The results of 60 patients on the B system and 51 on the Y system were analyzable. They were followed up for a median of 16 months. Peritonitis rates for the B and the Y systems were 33.5 and 29.4 patient-months per episode, respectively. Exit site infection rates for the B and Y systems were 17.4 and 16.0 patient-months per episode, respectively. Four catheters were removed in each group. Patients on the B system were hospitalized for 2.1 days per patient per year related to peritonitis and exit site infection, and those on the Y system were hospitalized for 1.2 days. There was no significant difference between the B and Y systems in the incidences of peritonitis (all causes and those due to coagulase-negative staphylococci), exit site infection, and in hospitalization days. However, there was a higher percentage of gram-positive infections in the Y system (52%) than in the B system (32%) and a lower percentage of gram-negative infections in the Y system (16%) than in the B system (32%). Patients on the B system had a better acceptance of the procedure than patients on the Y system, as assessed by a six-item, 10-point questionnaire (total score, 43.1 +/- 10.2 v 37.6 +/- 9.4; P < 0.005 at 1 month; 44.6 +/- 9.1 v 39.8 +/- 8.6; P < 0.01 at 6 months). From this study, it is concluded that the B and Y systems are similar in the incidences of peritonitis and exit site infection, although the B system is better accepted by patients. This is probably the first multicenter randomized study comparing the double-bag and Y-set disconnect system using only new patients who had never used other systems of continuous ambulatory peritoneal dialysis.

Adult

Determination of the solute removal index for urea by using a partial spent dialysate collection method.

In 22 hemodialysis patients, during a dialysis session, the solute removal index (SRI) for urea obtained from the use of a partial spent dialysate collection method was compared with that derived from the use of a total spent dialysate collection technique. The partial spent dialysate collection method was used to harvest a small representative sample of the total spent dialysate. The volumes of spent dialysate collected by the partial and the total spent dialysate collection methods were 1.7 +/- 0.4 L and 129.6 +/- 15.3 L, respectively. The total amount of urea nitrogen removed by dialysis as estimated by the partial spent dialysate collection method was similar to that determined by the total spent dialysate collection approach. As a result, the SRI value for urea obtained by the partial spent dialysate collection method (namely, 63% +/- 8%) correlated very well (r = 0.95, P < 0.001) with that derived by the total spent dialysate collection technique (namely, 62% +/- 8%). Our data suggest that it is feasible to use a simple partial spent dialysate collection method to obtain SRI results in patients treated with hemodialysis.

Female

A partial dialysate collection method.

This study validates Ing's partial dialysate collection method, which employs proportionate collection using a side tube capped with a small-gauge plastic needle. The urea nitrogen and creatinine levels of the small representative fraction of spent dialysate collected in the above fashion are undistinguishable from those obtained from the total spent dialysate. The estimated urea nitrogen removed during hemodialysis using this approach is similar to that using the total dialysate collection method; Ing's method is simple and useful in quantifying the dialysis dosage and in its assessment of the nutritional status of patients on hemodialysis.

Bicarbonates

Peritoneal catheter-related complications: a comparison between hemodialysis and intermittent peritoneal dialysis in the break-in period.

We prospectively monitored the clinical outcome of 89 curled, double-cuff peritoneal catheters (PC) implanted by surgeons over one year. Thirty-six cases (40%) were supported with hemodialysis (HD) (group A) and 53 cases (60%) were supported with weekly intermittent peritoneal dialysis (IPD) (small exchange volume with a cycler) (group B) for four weeks before commencing continuous ambulatory peritoneal dialysis (CAPD). PC-related complications between the two groups were compared. Ten cases failed to complete the six-month observation period (8 died, 1 received kidney transplant, and 1 defaulted follow-up),Total experience accumulated was 494 patient-months (195 patient-months in group A, 299 patient-months in group B). The incidence of pericatheter leakage (group A vs group B) was significantly higher in group B (0% vs 13%, p < 0.05). There were no significant differences in the incidence of other PC-related complications, removal of PC, and mortality rate in the two groups. The incidence of pericatheter leakage was significantly higher in diabetic patients (71% vs 22%, p < 0.05), and group B patients with leakage had a higher incidence of external cuff erosion 57% vs 7%, p < 0.005) and delay in CAPD training (71% vs 7%, p < 0.005). We conclude that both HD and IPD are equally safe renal replacement therapies in the break-in period, while patients supported with IPD had a higher incidence of pericatheter leakage, which was associated with other catheter-related morbidities including external cuff erosion and delay in CAPD training.

Adult

Pure red cell aplasia associated with thymic lymphoid hyperplasia and secondary erythropoietin resistance.

Systemic disorders, often immune in nature, can sometimes be associated with the presence of thymic pathology. Thymic enlargement due to lymphoid hyperplasia or thymoma is a common occurrence in patients with myasthenia gravis. In patients with pure red cell aplasia, at least 10% to 15% of patients are found to have thymoma, usually of spindle cell or medullary type. Pure red cell aplasia with demonstrable thymic enlargement due to lymphoid follicular hyperplasia is distinctly unusual, and has not been previously reported. The authors report such a case developing in a patient with end-stage renal failure maintained on hemodialysis and erythropoietin therapy. Because the red cell aplasia resolved after thymectomy, the disease process was considered etiologically related to the reactive lymphoid hyperplasia.

Adult

Peritoneal equilibration test in Chinese patients.

Since the introduction of the peritoneal equilibration test (PET) by Twardowski in 1987, it became a widely accepted test that provided useful prognostic information on continuous ambulatory peritoneal dialysis (CAPD). It had been shown to be a readily reproducible test if the standard procedure was followed. Although there was wide interpersonal difference in the test results, the mean and range (and standard deviation, SD) were remarkably similar as suggested by Davies et al. in 1993 (3). We had performed PET on our CAPD patients for a few years, and all along we used the reference range established by Twardowski to classify our patients into High, High average, Low average, and Low transporters because no reference range had ever been established in Chinese. The aim of this study was to define the normal mean and range of the PET results in Chinese CAPD patients. We analyzed 100 PET results from 100 Chinese CAPD patients. The mean +/- (SD) of the ratio of dialysate/plasma of creatinine and glucose at four-hour dwell times were 0.71 (0.15) and 0.37 (0.12), respectively. There was a significant difference in the dialysate/plasma ratio of creatinine (p < 0.01) while that of glucose was similar when compared with those found by Twardowski. There was no difference in the solute transfer in diabetic and nondiabetic patients. We concluded that the creatinine clearance of the peritoneal membrane in Chinese CAPD patients was higher than the previously reported result in North American patients.

Adult

Antilactoferrin antibody in systemic lupus erythematosus.

Lactoferrin is a secondary granule protein of neutrophils. Seventy-nine systemic lupus erythematosus patients who fulfilled the ARA criteria for classification were tested for antibody against human lactoferrin (LF-ab) by ELISA. Thirty-one of these (39.2%) demonstrated elevated levels. There was significant correlation between LF-ab positivity and disease duration. Clinical flare was common with positive LF-ab (P less than 0.05). Disease manifestations were independent of antibody status except for an increased incidence of lymphadenopathy and crescentic gomerulonephritis among those who had LF-ab. No consistent immunofluorescence pattern could be demonstrated on alcohol-fixed neutrophils for the LF-ab positive sera. It is suggested that LF-ab is related to lupus activity, and can be useful as a marker for disease monitoring.

Adolescent