Search PubMed⌕ Search

Biomedical subjects

K Engelke

Publications and source records attributed to K Engelke.

57 records · Page 4Linked to original sources

CT of metal implants: reduction of artifacts using an extended CT scale technique.

PURPOSE: The purpose of this work was to use an extended CT scale technique (ECTS) to reduce artifacts due to metal implants and to optimize CT imaging parameters for metal implants using an experimental model. METHOD: Osteotomies were performed in 20 porcine femur specimens. One hundred cobalt-base screws and 24 steel plates were used for osteosynthesis in these specimens. Artificial lesions were produced in 50 screws, such as osteolysis near the screws (mimicking lysis due to infection, tumor, or loosening), displacement of the screws, as well as fractures of the screws. All specimens were examined using eight different CT protocols: four conventional (CCT) and four spiral (SCT) CT protocols with different milliampere-second values (130 and 480 mAs for CCT, 130 and 300 mAs for SCT), kilovolt potentials (120 and 140 kVp), and slice thicknesses (2 and 5 mm). The images were analyzed by three observers using a standard window (maximum window width 4,000 HU) and ECTS (maximum window width 40,000 HU). Receiver operating characteristic analysis was performed, and image quality was assessed according to a five level scale. RESULTS: Metal artifacts were significantly reduced using ECTS (p < 0.05). The highest diagnostic performance was obtained using ECTS with the thinnest slice thickness. Metal artifacts were more pronounced using SCT. In this experimental model, exposure dose and kilovolt potential had no significant impact on diagnostic performance (p > 0.05). CONCLUSION: ECTS improved imaging of metal implants. In this study, no significant effects of exposure dose and kilovolt potential were noted. Metal artifacts were more prominent using SCT than using CCT.

Animals↗

A fast low-noise line scan x-ray detector.

A fast, low-noise line scan detector (NIKOS) for digital radiography has been developed. It consists of an input x-ray phosphor screen that is coupled to a modified Reticon photodiode array by means of fiber optics with incorporated image intensifier. In its current version the detector can be operated with a maximum 500 Hz image acquisition rate for interlaced readout of two lines of 128 pixels each. Using a Gd2O2S:Tb x-ray input phosphor, an afterglow of 25% in the first subsequent readout was observed. We also conducted afterglow measurements on several other powder and single-crystal phosphors and the photodiode array. Using CdWO4, the afterglow of the detector is limited by the lag of the photodiode array of 4.5%. By modifying the readout electronics the noise of the photodiode array was reduced to below 1 Graylevel, corresponding to a signal-to-noise ratio of 5200. The detective quantum efficiency (DQE) of the detector ranged from 0.18 to 0.4 for typical signal levels. The sensitivity was 10% saturation per 1.9 mR entrance dose. The modular design of the NIKOS detector allows for individual selection of each component to optimize performance for a given application.

Equipment Design↗