[Evaluation of surgical procedures based on the types of hypertrophied obstructive cardiomyopathy].

The surgical procedures were reviewed based on the types of hypertrophied obstructive cardiomyopathy in 20 patients. The patients were classified in three groups: (1) Asymmetric septal hypertrophy (ASH), (2) Atypical or diffuse concentric hypertrophy (DIF), (3) Mid ventricular obstructive hypertrophy (MID). Among 11 patients with ASH, the ventricular septal myotomy (My) or the myotomy-myectomy (Mye) were performed in 9 patients and MVR was performed in 2 patients. Among 6 patients with DIF, My or Mye were performed in 4 and MVR was performed in 2. All three patients with MID were treated with MVR. The intraventricular systolic pressure gradient greater than 40 mmHg was still existent postoperatively in one ASH patient on whom Mye was performed and in 3 DIF patients on whom My or Mye were performed. The four patients had III degree mitral regurgitation preoperatively and were successfully treated. The postoperative NYHA functional class became II or less in all patients. For ASH, the My was effective in 9 patients except one earlier patient. For DIF, further consideration of surgical procedure might be required. For MID, a MVR is recommended.

Adult↗

Prediction of postoperative exercise tolerance after aortic valve replacement.

Valve size selection for aortic valve replacement is still a controversial matter, particularly in patients with small aortic annuli. To assess optimal valve size, exercise capacity, as measured by peak oxygen consumption levels, was determined in 39 patients (age range, 18 to 77 years; mean, 56 years) who underwent isolated aortic valve replacement with a St. Jude Medical valve. This assessment was carried out at a mean of 2.2 years post-operatively using ergometer exercise testing. These levels were evaluated as a measure of the percentage of predicted. At rest, there was no significant correlation between the predicted peak oxygen consumption and the pressure gradients across the prostheses, as measured by Doppler ultrasound. In 18 patients with aortic regurgitation, the preoperative dimensions of the left ventricle in end-diastole and end-systole correlated inversely (p < 0.05) with the percentage of predicted peak oxygen consumption. In 21 patients with aortic stenosis, the linear regression line (p < 0.01) was derived from the correlation between the percentage of predicted peak oxygen consumption and the valve area index (geometric valve orifice area/body surface area). We conclude that the preoperative end-systolic and end-diastolic dimensions should be less than 50 mm and 70 mm, respectively, in the setting of aortic regurgitation, and a valve area index, though it proved to be weakly correlated with the percentage of the peak oxygen uptake, should probably be more than 1.5 cm2/m2 in the setting of aortic stenosis to achieve good exercise capacity postoperatively (> 80% of predicted peak oxygen consumption).

Adolescent↗

[A case of aortitis operated twice Bentall's operation due to valve (graft) detachment].

A 40-year-old man had received emergency Bentall's operation due to acute aortic regurgitation (AR) of aortitis in October, 24, 1990. On out patient clinic, the CRP had been kept from 0.5 to 1.5 mg/dl in dose of 10 mg of prednisolone. In the midnight of November, 17, 1992, his condition deteriorated to circulatory shock and echocardiography revealed massive AR due to para-annular graft detachment with large pseudoaneurysm of 50 mm. He was transferred for emergency operation. The composite graft shifted 2-3 cm above the annulus and detached in three quarter of the annulus. Distal anastomosis was also detached in half of anastomosis and coronary anastomosis almost detached. He was operated on modified Bentall's operation employing Piehler's technique and he is now followed in dose of 10 mg of prednisolone. There are some cases of aortitis showing recurrent valve or graft detachment like this case, even if modified Bentall's operation have been done to decrease the mechanical stress to the annulus and the inflammation have been controlled under the dosage of steroid.

Adult↗

Comparison of repair techniques for mitral valve prolapse.

Between January 1978 and September 1992, 127 patients with isolated mitral regurgitation due to prolapse underwent mitral valve reconstruction. There were 74 men and 53 women whose mean age was 49.7 years, ranging from 16 to 74 years. Follow up was 99.2% complete and totaled 483.0 patient-years (mean: 3.8 years). One hundred and forty-eight procedures were carried out to repair the prolapses using four types of techniques: (1) leaflet plication in 97 patients; (2) artificial chordal replacement with polytetrafluoroethylene sutures in 30 patients; (3) chordal shortening in 16 patients; and (4) commissural imbrication in five patients. In order to repair the annular dilation, commissural plications were done in 75 and ring prostheses were implanted in 15 patients. There were one hospital and eight late deaths. One (cerebral infarction) of all deaths was related to the reconstructed mitral valve. There were 14 reoperations (11.0%) for recurrent mitral incompetence with a freedom from reoperation of 89.0% at five, and 81.1% at 10 years. There were four cases of thromboembolism (one fatal, three non-fatal) with freedom from thromboembolism of 96.7% at five, and 93.3% at 10 years. No endocarditis or hemorrhagic complications were noted. Linearized incidence of recurrent mitral regurgitation according to repair technique for the prolapse was 1.44%/pty in the leaflet plication series, 1.45%/pty with chordal replacement, 4.37%/pty after chordal shortening and 8.67%/pty following commissural imbrication. The linearized rate of failure in annuloplasty was 2.91%/pty after commissural plication and 1.74%/pty after ring annuloplasty. Statistically significant difference was confirmed only between leaflet plication and chordal shortening.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Cox maze procedure for chronic atrial fibrillation associated with mitral valve disease.

Between April 1992 and October 1993, we combined a modified maze procedure with mitral valve repair (n = 26) or replacement (n = 36) in 62 patients with atrial fibrillation, including 16 patients undergoing reoperation. Associated procedures included aortic valve operation (n = 22), tricuspid annuloplasty (n = 28), atrial plication (n = 10), and others (n = 3). Duration of atrial fibrillation varied from 0.1 to 23 years (average 8.3 +/- 6.4 years), the f-wave voltage ranged from 0 to 0.45 mV (0.16 +/- 0.09 mV), and cardiothoracic ratio varied from 46% to 85% (64% +/- 9%). We modified the maze atriotomies to preserve the sinus node artery and used cryoablation to simplify procedures. Aortic crossclamp time was 142 +/- 25 minutes and cardiopulmonary bypass time 226 +/- 34 minutes. No early or late deaths occurred in a total of 783 patient-months of follow-up. In 52 patients (84%) who regained atrial rhythm, an atrial A-wave was detected in 84% for transtricuspid flow and in 71% for transmitral flow. One patient with sinus rhythm had an episode of transient neurologic ischemia 4 months after mechanical valve implantation. The 10 patients who remained in atrial fibrillation had preoperative fibrillation for a significantly longer time than the rest of the patients with atrial rhythm (14.8 versus 7.2 years p < 0.001) and a larger left atrial dimension (70 versus 58 mm, p < 0.01). Nonetheless, no variable alone could have predicted postoperative rhythm for individual patients. The results suggest that the maze procedure is safe and effective and therefore should be considered for patients with chronic atrial fibrillation undergoing mitral valve operations.

Adult↗

Short-term outcome of a new modification of the Bentall operation: Carrel patch and inclusion technique.

Leakage around the coronary ostia continues to be the major complication of composite graft replacement of the ascending aorta and aortic valve. To reinforce coronary anastomosis and reduce the operating time, a new modification of the Bentall operation was developed. This procedure involves dissecting full-thickness coronary buttons while leaving the epicardium on the aortic wall and complete wrap of the composite graft by the tailored aortic wall (Carrel patch and inclusion technique). Since March 1983, this approach has been performed in 12 patients (group A) and other Bentall-type operations in 22 (group B). Time affected by haemostasis was 28 min less in group A than in B (P = 0.23). Blood loss and blood transfusion during surgery and hospitalization were significantly lower in group A than B. Significantly less leakage occurred in group A than in B. On the basis of these short-term results, the Carrel patch and inclusion technique is considered to be an accurate time- and blood-saving procedure.

Adult↗

Systolic anterior motion of the mitral valve after mitral valve repair without a ring.

We report a case of systolic anterior motion of the mitral valve after mitral reconstruction without a semirigid mitral annular ring. A 56-year-old man with mitral regurgitation due to ruptured chordae tendineae underwent mitral valve reconstruction by replacement of chordae tendineae, leaflet excision, and suture annuloplasty without an annular ring. Postoperatively, left ventricular outflow tract obstruction developed and echocardiography revealed systolic anterior motion of the mitral valve. These findings disappeared after medication with a beta-blocking drug.

Chordae Tendineae↗

New modified Bentall procedure: Carrel patch and inclusion technique.

In Bentall-type procedures, the bleeding and dehiscence occurring around the coronary ostial anastomosis still remain major complications. To reinforce the coronary anastomosis and shorten the time required for hemostasis, a Carrel patch and inclusion technique was employed without any subsequent complications in 13 patients. We excised the coronary ostium with a collar of the aortic wall while leaving epicardium on the aortic wall, anastomosed it to the composite graft, and then included the graft with the aortic wall.

Anastomosis, Surgical↗

[Application of cryopreserved allograft to aortic root replacement for valve detachment case due to aortitis].

A 54-year-old male who had received an aortic valve replacement with SJM 23 about 3 years before suffered from an acute cardiac failure because of the valve detachment. From his clinical course, it was diagnosed that the aortic valve insufficiency was complicated by an aortitis. We operated on him by an aortic root replacement using a cryopreserved allograft which we prepared. A donor of the allograft was 35-year-old male, died of a subarachnoidal hemorrhage. We harvested his aortic root at an autopsy and dipped it into a nutrition medium with 10% dimethylsulfoxide. Within 10 hours from his death, we froze the tissue using a program freezer and stored it in a liquid nitrogen for 7 months. After thawing it in 37 degrees C water quickly, we rinsed the graft and used for the operation. The cell viability of the graft was confirmed by a tissue culture. Indication of the allograft valve to an aortitis case is still controversial. We think the allograft is recommendable to valve detachment case due to aortitis, because the softness of the graft decreases a compliance mismatch between the graft and the patient's annulus, which may prevent redetachment. Although we felt concern about redetachment of the conduit due to the weakness of the patient's aortic annulus, no complication regarding the allograft happened at all as yet.

Aortic Valve↗

Clinical experience of mitral valve reconstruction with artificial chordae implantation.

To expand the application of mitral valve reconstruction for pure mitral regurgitation due to diffuse leaflet prolapse, we have employed artificial chordae implantation using GPEP strips in 9 patients and 4-0 PTFE sutures in 20 patients since November 1986. The total number of GPEP strips implanted was 20 with a range from 1 to 4 (average 2.2 per patient) and 45 pairs of PTFE sutures with a range from 1 to 6 (average 2.3 per patient). There was one hospital death (3.4%). All other patients survived operation without valve-related complications except 1 patient who required reoperation for failure of mitral valve reconstruction. In 27 survivors free from reoperation, the amount of mitral regurgitation assessed postoperatively was none or trivial in 19 patients, mild in 7 and moderate in 1. All 27 patients improved to NYHA functional class I or II. So far, our results were no less acceptable than those with conventional procedures for mitral valve prolapse.

Adolescent↗

Right ventricular/arterial coupling in the patient with left ventricular assistance.

BACKGROUND: Improvements are known to occur in right ventricular (RV) ejection fraction after the use of a left ventricular assist device (LVAD); less is known, however, about the mechanism of this improvement. The concept of ventricular/arterial coupling was applied to investigate whether systolic pump function or afterload reduction was the major contributing factor leading to the improvement in RV ejection fraction. METHODS AND RESULTS: Eight consecutive patients who underwent Novacor LVAD implantation as a bridge to transplantation were studied intraoperatively with transesophageal echocardiogram and a catheter-tip manometer to examine the RV end-systolic pressure-area relation (ESPAR) before and after LVAD implantation. Fractional area change (FAC) obtained by echocardiogram was used as an approximation of ejection fraction. End-systolic elastance (Ees), area axis intercept of ESPAR (A0), maximal area (Amax), and pulmonary effective arterial elastance (Ea) were obtained. RV FAC improved from 0.20 +/- 0.09 to 0.29 +/- 0.13 (p < 0.05). There was a decrease in Ea from 12.06 +/- 5.79 to 4.92 +/- 2.51 mm Hg/cm2 (p < 0.01), which indicated a reduction in RV afterload. A0 increased from -0.14 +/- 7.81 to 6.83 +/- 9.42 cm2 (p < 0.05), which implied impaired systolic pump function. There was no difference in Ees and Amax. CONCLUSIONS: The concept of ventricular/arterial coupling predicts that an increase of A0 (reduced RV systolic mechanics) decreases FAC, whereas a reduction in Ea improves FAC. The improvement in RV FAC (improved RV pump performance) may result from the effect of reduced Ea (afterload reduction) overwhelming the effect of increased A0. Afterload reduction is the most likely mechanism by which RV ejection fraction improves after LVAD implantation.

Adolescent↗

[Initial and follow-up results of PTCA and PTMC].

On the bases of the initial and follow-up results of patients who underwent percutaneous transluminal coronary angioplasty (PTCA) and percutaneous transvenous mitral commissurotomy (PTMC), the proper applications of these interventional therapies were discussed. The efficacy of PTMC on valvotomy was comparable to open mitral commissurotomy and the procedural safety was noticed. Our results supported the use of PTMC for patients with plicable mitral valve. Despite the good and acceptable results of elective PTCA, low initial success rate and high incidence of major cardiac events including mortality was noted in the group of urgent PTCA for patients with multivessel lesions. The urgent use of PTCA for refractory unstable angina should be restricted to selected patients without high-risk multivessel lesions.

Angioplasty, Balloon, Coronary↗

[An emergent aortic and mitral valve replacement for active infective endocarditis preoperatively using extracorporeal ultrafiltration method].

We reported a 29-year-old man with active endocarditis complicating aortic and mitral valve regurgitation. The echocardiogram showed a mycotic aneurysm at aortic valvular annulus and a aneurysm of mitral valve. Heart failure was progressive and caused anuria. Prior to emergent double valve replacement, 2,500 ml of water was removed. Then hemodynamics became stationary. Urination was good during and after operation. In this case, complicating acute renal failure, dehydration with extracorporeal ultrafiltration method was very effective for improvement of hemodynamics.

Adult↗