Search PubMed⌕ Search

Biomedical subjects

K E Burton

Publications and source records attributed to K E Burton.

9 recordsLinked to original sources

Conformal rotation therapy with central axis beam block is a feasible alternative to intensity-modulated radiotherapy for chordomas of the cervical spine.

AIMS: Paraspinal tumours, such as chordoma, represent a treatment challenge for oncologists, requiring high dose to the target volume without exceeding the tolerance dose of the spinal cord. Intensity-modulated radiotherapy (IMRT) is helpful in achieving sharp dose gradients and conformation of dose to the target volume. We present a simpler technique--conformal rotation therapy with a central axis beam block (CRT + BB), which can provide similar dose distributions. MATERIALS AND METHODS: A patient with a cervical chordoma developed postoperative recurrence and was treated with high-dose palliative radiotherapy. Treatment was delivered using CRT + BB, with three fixed beams and three coplanar arcs. A dose of 62 Gy in 31 fractions was delivered to the 100% isodose, giving a maximum spinal cord dose of 49.6 Gy. The patient relapsed 2 years later, and was re-treated using the same technique to a dose of 57 Gy in 30 fractions. Estimates of spinal cord repair rates in primates were used to determine the tolerance dose of the spinal cord for re-treatment. The patient remained well for a further 25 months before developing local recurrence, which was treated with palliative chemotherapy. RESULTS: Re-treatment plans using CRT + BB and IMRT were compared. Dose-volume histograms show equivalence of dose to the spinal cord, although the IMRT plan delivered a slightly higher dose to tumour and lower dose to surrounding soft tissues. CONCLUSION: Treatment using CRT + BB requires careful planning and discussion with neurosurgeons before surgery. The normal curvature of the cervical spine must be eliminated if possible, and the patient must be immobilised with the neck horizontal. If these geometric constraints can be satisfied, then CRT + BB can be used as a safe and effective alternative treatment to IMRT for tumours at this site.

Aged↗

Accuracy of a relocatable stereotactic radiotherapy head frame evaluated by use of a depth helmet.

In high precision radiotherapy, the more accurately the patient can be relocated, the smaller the clinical to planning target volume margin can be, with reduction in the volume of normal tissue irradiated. The Gill-Thomas-Cosman (GTC) relocatable stereotactic head frame provides immobilization of the patient which is highly reproducible. A depth helmet and measuring probe were used to confirm the accuracy of relocation of 31 patients treated in the GTC frame. The measurements were processed in a spreadsheet developed to calculate the size of the patient's displacement as a vector. Twenty-seven patients received fractionated stereotactically-guided conformal radiotherapy, and 4 single fraction stereotactic radiosurgery, amounting to 564 measurement episodes. The accuracy was extremely good, and considerably more accurate than standard thermoplastic head shells. Ninety-two percent of the displacement vectors were less than 2 mm, and 97% less than 2.5 mm. Considering each dimension separately, the largest mean displacement was 0.4 mm in the superior-inferior direction. Accuracy was constant through a fractionated course for most patients, but prediction based on measurements from the first few fractions was not reliable. Results were dependent on patient selection, with worse reproducibility in patients with neurological deficits, or difficulty cooperating. The depth helmet measurements detected a loosened mouth bite in one patient and allowed repositioning to be verified without the need for the simulator. Total treatment time, including use of the depth helmet to verify treatment position, is quicker (mean 15.7 min) than using portal films. The depth helmet, used in conjunction with the vector displacement spreadsheet, provides a simple way to define the CTV-PTV margin. For fractionated stereotactic radiotherapy we use a 3 mm CTV-PTV margin. This system could assist technology transfer to centres starting stereotactic radiotherapy using the GTC frame.

Brain Neoplasms↗

A tool to measure radiotherapy complexity and workload: derivation from the basic treatment equivalent (BTE) concept.

Radiotherapy workload is poorly represented by simple parameters of patients, fractions or fields treated because these do not contain any measure of treatment complexity. However, complexity is increasing and there is an urgent need to quantify this. We have evaluated the basic treatment equivalent (BTE) model as a measure of radiotherapy workload and complexity. Radiotherapy treatment times, from the patient entering to exiting the treatment room maze, were measured for 1298 treatment sessions on 269 patients. The data were used to assess the original model and derive three new models for predicting treatment duration. The most complicated, the 'Addenbrooke's complex model', contained two additional predictor variables, including 'site/technique', in a linear additive form. Before the study, the department used a standard treatment appointment time of 10 minutes. However, 50% of the measured treatments took longer than 10 minutes, (mean 10.9). Summed over the working day, this discrepancy indicates that a standard 10-minute appointment is a poor basis for scheduling radiotherapy. The original BTE model was effective in predicting treatment times, although this was improved by refinement of the model. The Addenbrooke's complex model correctly predicted 70% of treatment times to within 2 minutes (55% for the original BTE model), 80% to within 2.5 minutes and 95% to within 4.7 minutes. The percentage of the variation in observed times accounted for by the model is 59.4%. The models can represent radiotherapy complexity, can improve scheduling on linear accelerators, and are likely to be applicable to other departments. They are thus tools to assess the impact of changes in complexity from new techniques, trial protocols (e.g. the Medical Research Council prostate radiotherapy trial RTO1), and possible time saving from advanced technology such as multileaf collimators (MLCs) or automated machine set-up. The replacement of manually-lifted shielding blocks by MLCs should save 1.1-1.5 minutes for a three- or four-field pelvic plan (i.e. 12%-13%). The models could also be used to aid planning for future linear accelerator provision and for costing radiotherapy treatment.

Efficiency, Organizational↗

The "total solution" for total hip replacement surgery.

Despite the great alleviation in suffering produced by total hip replacement surgery, some caution is indicated. Many of the patients who undergo surgery still present problems some time after the operation and for which there is no obvious or adequate medical or engineering explanation. It is therefore suggested that no report on such surgery is complete without regard for patients' expectations, patients' satisfaction and without common agreement by surgeons on what can be expected from the operation. This paper highlights the importance of patients' and surgeons' expectations and the need for all to be aware of the influence of such expectations. If also suggests that surgeons rely heavily on their own judgements as to what state patients should be in prior to surgery. If the solution for such a radical measure is to be total for the patient, then patients' feelings and judgements should also be considered.

Aged↗

What shall we teach undergraduates?

The opinions of 600 randomly selected doctors on what should be taught to undergraduates in clinical years were analysed. The respondents gave a high priority to general medicine, paediatrics, general surgery, casualty, and gynaecology, but a low priority to forensic medicine, plastic surgery, radiotherapy, anaesthetics, radiology, and rehabilitation medicine. Doctors thought that these should be taught to postgraduates. The two major groupings of doctors--general practitioners and consultants--gave essentially the same priorities. Undergraduate curricula cannot include all major specialities, so the results of this analysis may provide a useful basis for selecting the most suitable subjects. Criteria for including other specialties might be the ability and enthusiasm of the teachers and well-thought-out and academically sound teaching programmes.

Attitude of Health Personnel↗

A simple goniometer for measuring hip function.

A goniometer was designed and developed in an attempt to find an objective method of measuring hip flexion and extension in walking as as indication of hip function. Existing goniometers were found to be inadequate for clinical and research use because either they did not provide sufficient information or the information they provided was more than necessary, requiring bulky and time-consuming power devices. The present goniometer is a compromise, providing a quick and easy-to-use clinical and research tool which measures total flexion and extension in walking.

Adolescent↗

Patients' expectations in relation to outcome of total hip replacment surgery.

The importance of expectations has been assessed by giving 88 patients who had undergone total hip replacement surgery a series of visual analogue scales to provide a pain score, a 5-point rating scale to assess their remembered expectations, and an interview to establish clinical, functional, social, and psychological data. Patients generally had high expectations, but only 55% had their expectations fulfilled. Despite this, 86% claimed the operation to be successful, though when questioned more closely patients noted a certain amount of displeasure about the outcome. Further analysis revealed that, when the sample was split into 2 groups of fulfilled and unfulfilled expectations, significant differences were noted in that the quality of life enjoyed by the former group was greater than that enjoyed by the latter group. This finding suggests that the notion of 'success' is not as effective as the notion of 'expectations' as a measure of the outcome of total hip replacement surgery.

Adult↗

Fragmentation of biliary calculi in 71 patients by use of intracorporeal electrohydraulic lithotripsy.

PURPOSE: Failure of percutaneous or endoscopic removal of biliary calculi is often associated with impacted stones or stones larger than 1.5 cm. In these difficult cases, intracorporeal electrohydraulic lithotripsy (EHL) is a method that allows large stones to be fragmented and removed percutaneously or endoscopically. In this study, the authors expand their experience with EHL and further evaluate the safety and efficacy of this technique to remove biliary tract calculi. PATIENTS AND METHODS: Intracorporeal electrohydraulic lithotripsy was used to treat 71 patients with calculi in the bile ducts (n = 35) or gallbladder (n = 36). Access was obtained by means of a surgical T-tube tract (n = 16), percutaneous transhepatic biliary drainage (n = 14), percutaneous cholecystostomy (n = 36), an intraoperative approach during common duct exploration (n = 2), and at endoscopic retrograde cholangiopancreatography (n = 3). RESULTS: EHL lithotripsy was effective in fragmenting all biliary stones in 69 of the 71 patients (97%). All of the stone fragments were removed in 67 of these 69 patients (94%). Major complications, including bile peritonitis and gallbladder necrosis, occurred in five patients; however, all major complications were related to the initial percutaneous drainage or tract dilation. No significant complications were directly attributable to the EHL procedure. CONCLUSION: Intracorporeal EHL is a safe and effective method that can be used to improve the success of percutaneous and endoscopic biliary calculi removal.

Adult↗