Search PubMed⌕ Search

Biomedical subjects

K Craig Goodrich

Publications and source records attributed to K Craig Goodrich.

3 recordsLinked to original sources

The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

Improved efficiency in double-inversion fast spin-echo imaging.

Double-inversion fast spin-echo (FSE) pulse sequences can be designed to provide excellent suppression of blood signal in black-blood MRI. However, because a nonselective inversion is used, these sequences typically have been highly inefficient. In this work it is demonstrated that the efficiency of double-inversion sequences can be greatly improved by a form of interleaving in which all of the slices to be imaged in a single pass are reinverted each time a signal is obtained from any single slice. To date, several studies have demonstrated a high level of blood suppression with these more efficient techniques.

Aged↗

Poly(l-glutamic acid) Gd(III)-DOTA conjugate with a degradable spacer for magnetic resonance imaging.

The clinical application of macromolecular Gd(III) complexes as MRI contrast agents is impeded by their slow excretion and potential toxicity due to the release of Gd(III) ions caused by the metabolism of the agents. A polymer Gd(III) chelate conjugate with a cleavable spacer has been designed to solve this problem. Poly(l-glutamic acid)-cystamine-[Gd(III)-DOTA] was prepared by the conjugation of DOTA to PGA (MW = 50,000) via cystamine, a cleavable disulfide spacer, followed by the complexation with GdCl(3). A Gd(III) DOTA chelate derivative was readily released from the polymer conjugate in the incubation with cysteine, an endogenous plasma thiol. The conjugate produced significant MRI blood pool contrast enhancement in nude mice bearing OVCAR-3 human ovarian carcinoma xenographs. Less significant contrast enhancement was observed for a small molecular contrast agent, Gd(DTPA-BMA). The pharmacokinetic MRI study showed that the Gd(III) chelate from the conjugate accumulated in the urinary bladder in a similar kinetic pattern to Gd(DTPA-BMA), suggesting that the chelate was released by the endogenous thiols and excreted through renal filtration. The preliminary results suggest that this novel design has a great potential to solve the safety problem of macromolecular MRI contrast agents.

Animals↗